Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.3 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹44.5 L+₹3.0 L (7.10%)Rejected-AOC | L2 | Rejected-AOC Not being L1 | |
| 3 | L3₹49.6 L+₹8.1 L (19.4%)Rejected-AOC | L3 | Rejected-AOC Not being L1 |
| Sl No | Description | Qty | Unit | ESS KAY BUILDER L3 | M/s. M Company L1 | GEE EMM ASSOCIATES L2 |
|---|---|---|---|---|---|---|
| 1.00 | Taking down cement plaster of any thickness from walls or ceiling, including raking out joints, hacking for key, scrubbing down with water, and disposing of debris outside the premises as specified and as directed, complete. | 750 | Square Meter | 40 ₹30,000 | 30 ₹22,500 Lowest | 32 ₹24,000 |
| 2.00 | Material and Labour for 12 millimeter thick rendering on fair faces of brickwork or concrete surfaces in cement mortar 1:6, finishing the surfaces even and fair without using extra cement. | 350 | Square Meter | 180 ₹63,000 | 170 ₹59,500 Lowest | 240 ₹84,000 |
| 3.00 | Material and Labour for 15 millimeter thick rendering on fair faces of brickwork or concrete surfaces in cement mortar 1:4, finishing the surface fair and even with waterproofing compound complete as specified and as directed.
(Note: waterproofing compound will be measured and paid separately) | 250 | Square Meter | 180 ₹45,000 | 170 ₹42,500 Lowest | 240 ₹60,000 |
| 4.00 | Material and Labour for 5 millimeter thick rendering on concrete surfaces in cement mortar 1:3, as in ceiling, finished the surfaces even and smooth without using extra cement, complete as specified and as directed. | 150 | Square Meter | 130 ₹19,500 Lowest | 170 ₹25,500 | 200 ₹30,000 |
| 5.00 | Supply only integral waterproofing compound conforming to IS-2645, complete as specified and as directed. | 67.5 | Kilogram | 60 ₹4,050 | 40 ₹2,700 | 25 ₹1,687.5 Lowest |
| 6.00 | Material and Labour for damp proofing treatment to wall with two-component acrylic polymer cementitious waterproof elastomeric coating, food grade mix, to form uniform slurry and apply with paint brush as the first coat. Then, laying a layer of fiberglass mesh cloth while the first coat is still green, with overlap of joints of fiberglass mesh not less than 10 millimeter. Then, finally applying the second layer mix by brush to the entire surface of the container, covering 0.6 to 0.78 Square Meter/G at 1 millimeter thickness in two coats, depending on the level of the substrate, and curing it for a minimum of 3 days, complete as specified and as directed.
Note: Quoted rate shall be deemed to be inclusive of all materials, labour, tools and plants, scaffolding, and working up to height 6 Meter, et cetera. | 450 | Square Meter | 700 ₹3,15,000 | 285 ₹1,28,250 Lowest | 300 ₹1,35,000 |
| 7.00 | Material and Labour for preparing new plastered surface and applying two coats of cement-based paint on walls, complete as specified and as directed. | 250 | Square Meter | 10 ₹2,500 Lowest | 20 ₹5,000 | 33 ₹8,250 |
| 8.00 | Material and Labour for preparation of old decorated plastered surfaces over 3 millimeter wall care putty to make surface smooth and applying two coats of oil bound distemper on walls, complete as specified and as directed. | 350 | Square Meter | 60 ₹21,000 | 30 ₹10,500 Lowest | 70 ₹24,500 |
| 9.00 | Material and Labour for preparation of new plastered surfaces and applying three coats of whitewash on ceiling, complete as specified and as directed. | 150 | Square Meter | 10 ₹1,500 Lowest | 15 ₹2,250 | 12 ₹1,800 |
| 10.00 | Material and Labour for preparing old decorated plastered or unplastered wall surfaces including cornices by brooming down with steel wire brushes and scraping down smoke, spots, et cetera, applying one coat of oil bound distemper and filling holes, et cetera, to make surface smooth, complete as specified and as directed. | 250 | Square Meter | 40 ₹10,000 | 25 ₹6,250 | 17 ₹4,250 Lowest |
Tender Value
₹60 L
EMD Value
₹1.1 L
Closing Date
5 Jan 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Amritsar
HQ CWE Amritsar
CERTAIN REPAIR TO OTM ACCN REGT UNDER AGE BR II UNDER GE AMRITSAR
2025_MES_744550_1
83084/E8
Open Tender
Civil Works
Item Rate
180 days
GE Amritsar
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE Amritsar
₹1.1 L
Yes
19 Feb 2026
15 Dec 2025
12 Jan 2026
15 Dec 2025
5 Jan 2026
29 Dec 2025
Taking down cement plaster of any thickness from walls or ceiling, including raking out joints, hacking for key, scrubbing down with water, and disposing of debris outside the premises as specified and as directed, complete.
Material and Labour for 12 millimeter thick rendering on fair faces of brickwork or concrete surfaces in cement mortar 1:6, finishing the surfaces even and fair without using extra cement.
Supplying and Fixing in replacement Surface Mount Device/PLUTO NEO LED luminaire, 36/40 Watt, 600 x 600 millimeter, 220 Volts Alternating Current LED ceiling light, recessed or surface type, with high efficiency Poly(methyl methacrylate) diffuser, soft glass free light, complete with driver, holders, and LED lamps, suitable for roof/ceiling, including fixing arrangements and connecting with copper wire flexible three core 1.5 Square Millimeter Polyvinyl Chloride insulated 3 core cable from the ceiling rose to the light fitting, complete as specified and as directed.
Material and Labour for 5 millimeter thick rendering on concrete surfaces in cement mortar 1:3, as in ceiling, finished the surfaces even and smooth without using extra cement, complete as specified and as directed.
Supply only integral waterproofing compound conforming to IS-2645, complete as specified and as directed.
Supplying and Fixing in replacement decorative Ceiling light, 12 Watt light fitting, Light Emitting Diode type, with accessories, including any type, complete as specified and as directed.
Material and Labour for preparing new plastered surface and applying two coats of cement-based paint on walls, complete as specified and as directed.
Material and Labour for preparation of old decorated plastered surfaces over 3 millimeter wall care putty to make surface smooth and applying two coats of oil bound distemper on walls, complete as specified and as directed.
Material and Labour for preparation of new plastered surfaces and applying three coats of whitewash on ceiling, complete as specified and as directed.
Material and Labour for preparing old decorated plastered or unplastered wall surfaces including cornices by brooming down with steel wire brushes and scraping down smoke, spots, et cetera, applying one coat of oil bound distemper and filling holes, et cetera, to make surface smooth, complete as specified and as directed.
Material and Labour for preparation of old decorated brick or concrete, plastered or unplastered surfaces of walls, pillars, and cornices by brooming down, et cetera, and applying one coat of whitewash on walls, pillars, and cornices, et cetera, complete as specified and as directed.
Material and Labour for preparation of old decorated brick or concrete, plastered or unplastered surfaces of ceiling by brooming down, et cetera, and applying one coat of whitewash on ceiling, et cetera, complete as specified and as directed.
Demolition of cement concrete in ground floors and pavings (unreinforced), not exceeding 15 centimeter thickness (below or above ground level), complete as specified and as directed.
Material and Labour for cement concrete type C-1, 1:3:6 (using 20 millimeter graded stone aggregate), 50 millimeter thick as in plinth protection, laid in bays not exceeding 2 Square Meter each, and finishing even and fair on top without using extra cement, complete as specified and as directed.
Material and Labour for preparation of old plastered wall surface and applying one coat of Acrylic Smooth exterior paint of required shade, applied at the rate of 1.67 Liter per 10 Square Meter, complete as specified and as directed.
Material and Labour for preparation of old decorated brick or concrete, plastered or unplastered surfaces of walls, pillars, and cornices by brooming down, et cetera, and applying one coat of cement-based paint on walls, pillars, cornices, et cetera, complete as specified and as directed.
Supplying and Fixing in replacement, Sub main wiring with two single pole 4 Square Millimeter (nominal area) stranded copper conductor Flame Retardant Low Smoke Polyvinyl Chloride insulated and unsheathed cable drawn in existing non-metallic Polyvinyl Chloride rigid conduit, medium grade, of suitable size, with all standard fittings, including one run of continuous 4 Square Millimeter (nominal area) Polyvinyl Chloride insulated stranded copper conductor Flame Retardant Low Smoke cable for earth continuity. This includes taking out and removal of old sub main wiring, complete as specified and as directed. (Note 1: Two runs of 4 Square Millimeter main cable and one run of 4 Square Millimeter for earth cable shall be measured as one unit/one Running Meter.)
Demolition of brickwork built in cement mortar, including separation, cleaning, and stacking of serviceable bricks for reuse, and removal of debris outside the premises as specified and as directed, complete.
Dismantling floor, hearth, or wall tiling, including cement mortar bedding (but not backing), and removing serviceable rubbish off the premises, complete as specified and as directed.
Material and Labour for coloured, non-skid / matt finish ceramic tiles, 7 to 8 millimeter thick (square / rectangular), where the area of each tile exceeds 0.18 Square Meter but does not exceed 0.38 Square Meter, installed in floors, et cetera. The tiles are set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including a screed bed or bedding layer of 15 millimeter thick cement mortar (1:6), complete as specified and as directed.
Material and Labour for Vitrified ceramic light shade tiles, 8 millimeter to 10 millimeter thick (Square or rectangular), polished, area of each tile not exceeding 0.36 Square Meter, installed in floors. The tiles are set and jointed in neat cement slurry and pointed in white or coloured cement to match, including screed bed or bedding layer of cement mortar (1:6), 15 millimeter thick, for laying floor finishes, complete as specified and as directed.
Material and Labour for Glazed ceramic coloured tiles in vertical surface, 300 millimeter by 450 millimeter by 7 millimeter thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match, such as skirting or dado, laid over 10 millimeter thick cement mortar 1:4 backing plaster, complete as specified and as directed.
Taking up or down steel tubing and connections for 15 millimeter bore of pipe, complete as specified and as directed.
Supplying and Fixing 15 millimeter diameter Tubes, 'medium grade' galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors, walls, et cetera (surface or concealed type), complete as specified and as directed.
Supplying and Fixing pressed steel frames, 1.25 millimeter thick, for door frame size 105 millimeter x 60 millimeter, with one or more rebates, including necessary fixing lugs, hinges, lock strike plate, and tarring to the inner surface (surface in contact with concrete/brick surface) of chowkats and hinges, complete as specified and as directed.
Material and Labour for Plain Cement Concrete 1:2:4 type B-0 (using 12.5 millimeter graded stone aggregate) in bed blocks for hold fast and similar work, et cetera, complete as specified and as directed.
Supplying and Fixing framed work, such as in doors or gates, of angle or other section with gusset plates, rails, braces, et cetera, complete, drilled for fixing of steel sheeting or other covering. Doors, et cetera, to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides), including hanging, fastening, and fixing complete. Material grade: FE-290 Grade E-165, as specified and as directed.
Supplying and Fixing 35 millimeter thick flush shutter, solid core construction, with block board core and plywood face panel commercial type on both sides, complete as specified and as directed.
Supplying and Fixing framed work such as grill, framed guard bar and similar work conforming to FE 290, Grade E-165, complete as specified and as directed.
Hacking out old broken glass of any thickness, size, quality, or description from wooden frames, metal frames, or stone, concrete, or brick surrounds, glazed with putty or fixed with beads, complete as specified and as directed.
Supplying and Fixing 3 millimeter thick ordinary sheet glass and glazing with oil putty or fixed on steel frame, in squares not exceeding 0.50 Square Meter in each pane, complete as specified and as directed.
Supplying and Fixing 150 millimeter aluminum, anodised, barrel tower bolts of extruded section, complete as specified and as directed.
Supplying and Fixing butt hinges, 100 millimeter size, medium weight, cold rolled mild steel, fixed with screws or welded to steel frame, complete as specified and as directed.
Supplying and Fixing Mild Steel 300 millimeter ordinary rat tail rod pattern spring, including roller and roller plate, and including necessary welding to the door frame, complete as specified and as directed.
Material and Labour for preparation of new steel surface and applying two coats of synthetic enamel paint over one coat of red oxide primer, complete as specified and as directed.
Material and Labour for preparation of new wood surface over 10 centimeter girth or width and applying two coats of synthetic enamel paint over a coat of pink primer, complete as specified and as directed.
Dismantling boarding of any description, fixed in any position with nails, complete as specified and as directed.
Material and Labour for Providing and Fixing 12 millimeter thick Seamless calcium silicate Gypsum board in ceiling, made out of 1800 millimeter x 1200 millimeter size board of siliceous and calcareous material, reinforced and fixed with screws. Including Galvanized Iron (GI) framework for seamless ceiling comprising of Galvanized Iron perimeter channel 0.55 millimeter thick with two unequal flanges of 20 millimeter and 30 millimeter and web of 27 millimeter, fixed to the surrounding wall using nylon sleeves and screws at 450 millimeter center to center. Including intermediate channel 0.9 millimeter thick having two equal flanges of 15 millimeter each and web of 45 millimeter, suspended from soffit at approximately 900 millimeter center to center with Galvanized Iron cleat and steel expansion fasteners. Including ceiling section (not exceeding 1.2 Meter length) of 0.55 millimeter thickness having knurled web of 50 millimeter and flange of 26 millimeter each with lips of 10.5 millimeter, fixed to the intermediate channel with connecting clips across the intermediate channel at 457 millimeter center to center and as per manufacturer's instructions. Including preparation of new surfaces and applying two coats of Oil Bound Distemper (OBD) on ceiling over chalk whitening, complete as specified and as directed.
Supplying and Fixing 5 millimeter thick Polyvinyl Chloride sheet fillet of width 35 millimeter for wall panelling, including fixing onto the wall to form a Polyvinyl Chloride frame, complete as specified and as directed.
Supplying and Fixing solid Polyvinyl Chloride Wall Lining consisting of 5 millimeter thick Plain colour Polyvinyl Chloride sheet, including solvent cement, and fixing at site onto the Polyvinyl Chloride frame, complete as specified and as directed.
Supplying and Fixing, in repair, 15 millimeter diameter Stop valves, high pressure, with crutch or butterfly handle, Chrome Plated, fancy type, screwed both ends for iron pipe or for unions, including extra Chrome Plated nipple wherever required, complete as specified and as directed.
Supplying and Fixing, in repair, 15 millimeter bore stop valve, fancy type, Chrome Plated, with long shank and cup (Concealed type), cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions, including extra Chrome Plated nipple wherever required, complete as specified and as directed.
Supplying and Fixing, in repair, for brass, Chrome Plated shower rose, 125 millimeter size, with swivel joint, including fixing to 15 millimeter diameter steel pipe or union, including extra Chrome Plated nipple wherever required, complete as specified and as directed.
Supplying and Fixing health faucet suitable for 15 millimeter diameter, fixed to Galvanized Iron tubing with Chrome Plated connection, complete as specified and as directed.
Material and Labour for preparation of old painted steel surfaces of any description, over 10 centimeter in width or girth, not otherwise described, for one coat of synthetic enamel paint, complete as specified and as directed.
Material and Labour for one coat of synthetic enamel paint, applied after preparation of old painted wooden surfaces of any description, not otherwise described, over 10 centimeter width or girth, complete as specified and as directed.
Supplying and Fixing, in repair, a hydraulically regulated door closer (Aluminium die cast body), designation Number 3, universal type, suitable for door shutters of 851 to 1000 millimeter in width and of weight between 61 to 80 Kilogram, complete as specified and as directed.
Material and Labour for 15 millimeter thick rendering on fair faces of brickwork or concrete surfaces in cement mortar 1:4, finishing the surface fair and even with waterproofing compound complete as specified and as directed. (Note: waterproofing compound will be measured and paid separately)
Supplying and Fixing Double action floor spring, hydraulically regulated, made up of minimum 1.25 millimeter thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel, heavy duty, and fixed. Make: Godrej, complete as specified and as directed.
Supplying and Fixing Anodised aluminium frame for doors, powder coated (minimum thickness of powder coating shall not be less than 50 micron), windows, ventilators, side hung, with one or more rebates, including necessary jointing cleats, glazing clips, complete as specified and as directed.
Supplying and Fixing Anodised aluminium window and ventilator shutters, side hung type without sash bars. The aluminium sections weigh 0.55 Kilogram per Meter, including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, and anodised aluminium fittings such as peg stays 150 millimeter long (1 Number), hinges type B-21 100 millimeter long (2 Numbers), and suitable handle (1 Number), complete as specified and as directed.
Demolition of mud phuska in roofs of any thickness, including plastering and leeping, removing debris and rubbish from the site, complete as specified and as directed.
Cubic Metre
Material and Labour for Cement concrete 1:2:4 type B-1 using 20 millimeter graded crushed stone aggregate as in roof padding (average 40 millimeter thick), roof kerbs or mud stops, rounded or chamfered on edge, complete as specified and as directed.
Material and Labour for damp proofing treatment to wall with two-component acrylic polymer cementitious waterproof elastomeric coating, food grade mix, to form uniform slurry and apply with paint brush as the first coat. Then, laying a layer of fiberglass mesh cloth while the first coat is still green, with overlap of joints of fiberglass mesh not less than 10 millimeter. Then, finally applying the second layer mix by brush to the entire surface of the container, covering 0.6 to 0.78 Square Meter/G at 1 millimeter thickness in two coats, depending on the level of the substrate, and curing it for a minimum of 3 days, complete as specified and as directed. Note: Quoted rate shall be deemed to be inclusive of all materials, labour, tools and plants, scaffolding, and working up to height 6 Meter, et cetera.
Material and Labour for APP based polymeric membrane, minimum weighing 3 Kilogram per Square Meter and minimum 3 millimeter thick, reinforced with polyester non-woven fabric (weight not less than 150 Grams per Square Meter), laid on a primed surface by forced application over a tack coat of industrial bitumen 85/25 at the rate of 1.6 Kilogram per Square Meter, including cleaning surfaces and including 10 millimeter thick 1:4 cement plaster on the padding surface, complete as specified and as directed.
Material and Labour for 40 millimeter thick brick tiles laid over and including 15 millimeter thick bedding layer in cement mortar 1:6 and jointed, grouted and flush pointing as work proceeds in Cement Mortar 1:3, complete as specified and as directed.
Material and Labour for 75 millimeter thick Plain Cement Concrete 1:4:8 type D2 (using 40 millimeter graded aggregate) as in sub base, complete as specified and as directed.
Material and Labour for sand filling under floors or in foundation, including watering and consolidation, complete as specified and as directed.
Material and Labour for machine pressed precast concrete interlocking paver block of any shape and size conforming to Indian Standard 15658-2006, 60 millimeter thickness, M-35 grade, made with grey cement and pigment, complete as specified and as directed.
Material and Labour for 20 millimeter thick screed bed or bedding layer of mortar for laying floor finishes in Cement Mortar 1:4, complete as specified and as directed.
Material and Labour for Box type steel ventilator made of Electric Resistance Welded tube P-section of size 60 millimeter by 25 millimeter outer frame (single rebated), comprising glazed shutter, frame of Electric Resistance Welded tube and Flat Iron 2 millimeter thick welded or screwed to frame for fixing of sheet glass, including fixtures and fittings such as Stopper, Cleat, Pintle hinges, holdfast, et cetera, all as shown on Drawing Number CEJZ/TD1019/08 Sheet 1/3 to 3/3 dated 01 May 2008, complete as specified and as directed. Note: Guard bar, Sheet glass, and painting shall be measured and paid separately.
Supplying and Fixing Anodised aluminium door shutters, powder coated (minimum thickness of powder coating shall not be less than 50 micron). The aluminium section weighs 0.55 Kilogram per Meter, including necessary joining cleats, glazing clips, rubber neoprene packing, 2 Numbers of handles in each door, hinges, anodised aluminium snap beading, screws, et cetera. Complete as specified and as directed. Note: Each panel shall be measured separately. Glass pane shall be measured and paid separately.
Material and Labour for laying 40 millimeter thick brick tiles over and including 15 millimeter thick bedding layer in cement mortar 1:6 and jointed, grouted and flush pointing as work proceeds in Cement Mortar 1:3, complete as specified and as directed, but excluding the supply of new tiles. Note: Serviceable brick tiles obtained from demolition shall be reused.
Material and Labour for point wiring drawn in existing concealed conduit for one light point, fan point, or bell point controlled by one switch (using red, black, and green colour wires as colour coding) complete with 1.5 square millimeter (nominal cross-section area) single core Flame Retardant Low Smoke Polyvinyl Chloride insulated unsheathed and multi-stranded copper conductor cable, 1100 volt (Indian Standards Institution marked), drawn through an existing Polyvinyl Chloride concealed conduit with all fittings and accessories. This includes a pressed steel powder-coated sunken terminal box suitable for a Modular switch socket (minimum 50 millimeter deep and 1.6 millimeter thick sheet, suitable size) concealed in the wall, including inner and outer plates (cover plate) suitable for fixing the modular switches/sockets/regulator, etc. This also includes the provision of a 1.5 square millimeter single core Flame Retardant Low Smoke Polyvinyl Chloride insulated multi-stranded copper conductor wire continuing as an earth wire connected to the earth dolly, etc., including cutting chases in the wall and making good disturbed surfaces of walls, ceiling, or floors, etc., by using Cement Mortar (1:3 mix), including fixing of the switch/socket/regulator, etc., complete as specified and as directed. (Note 1: Switches/sockets/regulators, etc., shall be measured and paid separately.)
For one light/fan/ buzzer point controlled by one 5 Amp switch one way
For one three pin socket outlet 5 Amps independent board complete.
For one three pin 5 Amps socket outlet on the same board with other switches.
For one light point controlled by two way switch.
Material and Labour for laying 40 millimeter thick brick tiles over and including 15 millimeter thick bedding layer in cement mortar 1:6 and jointed, grouted and flush pointing as work proceeds in Cement Mortar 1:3, complete as specified and as directed, but excluding the supply of new tiles. Note: Serviceable brick tiles obtained from demolition shall be reused.
Material and Labour for point wiring drawn in existing concealed conduit for one light point, fan point, or bell point controlled by one switch (using red, black, and green colour wires as colour coding) complete with 1.5 square millimeter (nominal cross-section area) single core Flame Retardant Low Smoke Polyvinyl Chloride insulated unsheathed and multi-stranded copper conductor cable, 1100 volt (Indian Standards Institution marked), drawn through an existing Polyvinyl Chloride concealed conduit with all fittings and accessories. This includes a pressed steel powder-coated sunken terminal box suitable for a Modular switch socket (minimum 50 millimeter deep and 1.6 millimeter thick sheet, suitable size) concealed in the wall, including inner and outer plates (cover plate) suitable for fixing the modular switches/sockets/regulator, etc. This also includes the provision of a 1.5 square millimeter single core Flame Retardant Low Smoke Polyvinyl Chloride insulated multi-stranded copper conductor wire continuing as an earth wire connected to the earth dolly, etc., including cutting chases in the wall and making good disturbed surfaces of walls, ceiling, or floors, etc., by using Cement Mortar (1:3 mix), including fixing of the switch/socket/regulator, etc., complete as specified and as directed. (Note 1: Switches/sockets/regulators, etc., shall be measured and paid separately.)
For one light/fan/ buzzer point controlled by one 5 Amp switch one way
Material and Labour for point wiring drawn in existing concealed conduit for one 3-pin socket outlet, 15 Amperes, on an independ
Per Point
per point
Supplying and Fixing Modular switch, flush type, one way, 6 Ampere, 230 volts, complete as specified and as directed.
Supplying and Fixing Modular switch, flush type, two way, 6 Ampere, 230 volts, complete as specified and as directed.
Supplying and Fixing Modular socket, 6 Ampere, 2 or 3 pin combined, 2 module, complete as specified and as directed.
Supplying and Fixing Modular switch, flush type, one way, 16 Ampere, 230 volts, complete as specified and as directed.
Supplying and Fixing Modular socket, 6 or 16 Ampere, 2 or 3 pin combined, 2 module, complete as specified and as directed.
Supplying and Fixing Modular switch, bell push switch, 6 Ampere, 1 module, complete as specified and as directed.
Supplying and Fixing ceiling rose, 65 X 50 millimeter, three terminals, complete as specified and as directed.
Supplying and Fixing Lamp holder, bakelite type, with back plate suitable for batten fitting, complete as specified and as directed.
Material and Labour for Earthing in replacement, complete with galvanized steel earth plate electrodes of size 60 centimeter x 60 centimeter x 6 millimeter thick, buried directly in ground vertically (earth pit not less than 2.25 meter deep below normal ground level) with the top edge of the plate not less than 1.5 meter below normal ground level, connected to galvanized iron or steel earth wire 4 millimeter diameter by means of bolts, nuts, check nuts, and Galvanized Iron washers, protected by steel pipe 15 millimeter (light grade), all as shown in electrical plate Number 3 of Standard Schedule of Rates Part-I. This includes connecting to the earthing test point (earth test point to be provided at 5 meter distance from the earth pit) and testing on completion, including necessary excavation and earth work. The rate also includes charcoal dust and salt in alternate layers, 25 millimeter diameter light grade Galvanized Iron pipe, funnel, wire mesh, Concrete (1:3:6 mix) type C-1 for the pit, and Reinforced Cement Concrete pit cover. The extra cost of the watering pipe, bends, and elbows shall be included in the unit rate. (Note: Reinforced Cement Concrete pit cover shall be precast of Reinforced Cement Concrete (1:2:4 mix) type B-1, 80 millimeter thick, reinforced with Expanded Metal weighing not less than 4 Kilogram per Square Meter), complete as specified and as directed.
Supplying and Fixing in replacement of Ding Dong bell, Alternating Current 230 Volts, complete as specified and as directed.
pplying and Fixing Modular stepped type electronic fan regulator, flush type, on the existing phenolic laminated sheet etcetera, as required, heavy duty, 230 volts, complete as specified and as directed.
Supplying and Fixing in replacement, sheet metal enclosure Distribution Boards, double door, factory made, flush fixed, complete with 200 Ampere rated bus-bar, 240 Volts, single phase, 8 ways, including necessary brick work and plaster to match with the existing surface, complete as specified and as directed.
Supplying and Fixing in replacement, sheet metal enclosure Distribution Boards, double door, factory made, flush fixed, complete with 200 Ampere rated bus-bar, 240 Volts, single phase, 12 ways, including necessary brick work and plaster to match with the existing surface, complete as specified and as directed.
Supplying and Fixing in replacement Miniature Circuit Breaker, single pole, 6 to 32 Amperes, complete as specified and as directed.
ent board. The wiring is complete with 2.5 square millimeter (nominal cross-section area) single core Flame Retardant Low Smoke Polyvinyl Chloride insulated unsheathed and multi-stranded copper conductor cable, 1100 volt (Indian Standards Institution marked), drawn through an existing Polyvinyl Chloride concealed conduit with all fittings and accessories. This includes a pressed steel powder-coated sunken terminal box suitable for a Modular switch socket (minimum 50 millimeter deep and 1.6 millimeter thick sheet, suitable size) concealed in the wall, including inner and outer plates (cover plate) suitable for fixing the modular switches/sockets/regulator, etc. This also includes the provision of a 2.5 square millimeter single core Flame Retardant Low Smoke Polyvinyl Chloride insulated multi-stranded copper conductor wire continuing as an earth wire connected to the earth dolly, etc., including cutting chases in the wall and making good disturbed surfaces of walls, ceiling, or floors, etc., by using Cement Mortar (1:3 mix), including fixing of the switch/socket/regulator, etc., complete as specified and as directed. (Note 1: Switches/sockets/regulators, etc., shall be measured and paid separately.)
Material and Labour for surface point wiring for one light point, fan point, or bell point controlled by one switch (using red, black, and green colour wires as colour coding) complete with 1.5 square millimeter (nominal cross-section area) single core Flame Retardant Low Smoke Polyvinyl Chloride insulated unsheathed and multi-stranded copper conductor cable, 1100 volt (Indian Standards Institution marked), drawn and including surface Polyvinyl Chloride conduit with all fittings and accessories, that is, pipe bend, pipe hook, elbow, junction boxes, etc. This includes a pressed steel powder-coated sunken terminal box suitable for a Modular switch socket (minimum 50 millimeter deep and 1.6 millimeter thick sheet, suitable size) concealed in the wall, including inner and outer plates (cover plate) suitable for fixing the modular switches/sockets/regulator, etc. This also includes the provision of a 1.5 square millimeter single core Flame Retardant Low Smoke Polyvinyl Chloride insulated multi-stranded copper conductor wire continuing as an earth wire connected to the earth dolly, etc., including cutting chases in the wall and making good disturbed surfaces of walls, ceiling, or floors, etc., by using Cement Mortar (1:3 mix), including fixing of the switch/socket/regulator, etc., complete as specified and as directed. (Note 1: Switches/sockets/regulators, etc., shall be measured and paid separately.)
Supplying and Fixing in replacement of Sheet metal single pole and neutral enclosure, 240 volts, with a two-pin and earth plug and socket, complete with one single pole Miniature Circuit Breaker, capacity 20 Amperes, as specified and as directed (for Air Conditioner and geyser).
Each job
Each Job
Supplying and Fixing in replacement LED tube light, 20 Watt (4 foot long), 6500 Kelvin, wall mounted, E-lite LED curve with high lumen batten, with efficacy not less than 100 lumens, with integrated electronic driver, complete with all accessories as specified and as directed.
Supplying and Fixing in replacement LED decorative Gate light or Garden lights, 20 Watt light fitting, with all accessories, including making connections by using a suitable size of Polyvinyl Chloride wire of any type, complete as specified and as directed.
Supplying and Fixing in replacement, LED street light fitting, powder coated, pressure die-cast aluminium compact, High power LED street light with heat resistant toughened glass, 25 Watt, with IP66 protection and impact resistance of IK07, including 10 Kilovolt Built-in Surge Protection Device. This includes a bracket made out of Galvanized Iron Pipe 40 millimeter, medium grade, 1.2 meter long, made to shape, with fixing clamps of Mild Steel Flat 40 x 6 millimeter, nuts and bolts, complete as specified and as directed.
For one light/fan/buzzer point controlled by one 5 Amp switch one way.
Material and Labour for surface point wiring for one 3-pin socket outlet, 15 Amperes, on an independent board, complete with 2.5 square millimeter (nominal cross-section area) single core Flame Retardant Low Smoke Polyvinyl Chloride insulated unsheathed and multi-stranded copper conductor cable, 1100 volt (Indian Standards Institution marked), drawn and including surface Polyvinyl Chloride conduit with all fittings and accessories, that is, pipe bend, pipe hook, elbow, junction boxes, etc. This includes a pressed steel powder-coated sunken terminal box suitable for a Modular switch socket (minimum 50 millimeter deep and 1.6 millimeter thick sheet, suitable size) concealed in the wall, including inner and outer plates (cover plate) suitable for fixing the modular switches/sockets/regulator, etc. This also includes the provision of a 2.5 square millimeter single core Flame Retardant Low Smoke Polyvinyl Chloride insulated solid copper conductor wire continuing as an earth wire connected to the common earth dolly, etc., including cutting chases in the wall and making good disturbed surfaces of walls, ceiling, or floors, etc., by using Cement Mortar (1:3 mix), including fixing of the switch/socket/regulator, etc., complete as specified and as directed. (Note 1: Switches/sockets/regulators, etc., shall be measured and paid separately.)
Supplying and Fixing in replacement, Fresh Air fan, size 250 millimeter, Plastic body, 1200 Revolutions Per Minute, electrically driven, 230 volts, 50 Hertz, single phase, Alternating Current supply, featuring copper winding and dynamically balanced impeller for smooth and vibration free operation, complete with louvers, nuts for fixing the exhaust fan, and 3 foot long bolts and nuts for fixing louvers, including associated civil work, making provision for the wall opening, and provision of Polyvinyl Chloride insulated, flexible copper conductor cord of size 23/0.0076, three core, from the ceiling rose to the fan, complete as specified and as directed. (Note: Making suitable opening for fixing the air fan shall be deemed included in the quoted rate of the item.)
Supplying and Fixing in replacement, Exhaust fan of size 300 millimeter, Heavy duty, 1200 Revolutions Per Minute, electrically driven, 240 volts, 50 Hertz, single phase, Alternating Current supply, featuring copper winding and dynamically balanced impeller for smooth and vibration free operation, complete with louvers, nuts for fixing the exhaust fan, and 3 foot long bolts and nuts for fixing louvers, including associated civil work, providing the wall opening, and provision of Polyvinyl Chloride insulated, flexible copper conductor cord of size 23/0.0076, three core, from the ceiling rose to the exhaust fan for giving connection, complete as specified and as directed. (Note: Making suitable opening for fixing the exhaust fan shall be deemed included in the quoted rate of the item. Old items shall be deposited in the store yard.)
Supplying and Fixing in replacement, Sub main wiring with two single pole 6 Square Millimeter (nominal area) stranded copper conductor Flame Retardant Low Smoke Polyvinyl Chloride insulated and unsheathed cable drawn in existing non-metallic Polyvinyl Chloride rigid conduit, medium grade, of suitable size, with all standard fittings, including one run of continuous 6 Square Millimeter (nominal area) Flame Retardant Low Smoke Polyvinyl Chloride insulated stranded copper conductor cable for earth continuity. This includes taking out and removal of old sub main wiring, complete as specified and as directed. (Note 1: Two runs of 6 Square Millimeter main cable and one run of 6 Square Millimeter earth cable shall be measured as one unit/one Running Meter.)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.74 MB
83084Tender.pdf
Tender Documents • 1.32 MB
BOQ_833700.xls
BOQ • 0.56 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .