Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.1 LAccepted-AOC NO 12 25 26 KATHIRAVAN NAGAR MAHALINGAPURAM PO POLLACHI COIMBATORE 642 002 | COIMBATORE | TAMIL NADU | 642002 | L1 | Accepted-AOC Being_L1 | |
| 2 | L2₹9.1 L+₹58,855.05 (6.92%)Rejected-Finance | L2 | Rejected-Finance quoted amount is higher than 1st lowest | |
| 3 | L3₹9.2 L+₹66,601.80 (7.83%)Rejected-Finance | L3 | Rejected-Finance quoted amount is higher than 1st lowest |
Tender Value
₹9 L
EMD Value
₹18,000
Closing Date
23 Oct 2023, 6:00 pmClosed
AGE I AF coimbatore
AGE I AF COIMBATORE AFAC COMPLEX KAMARAJAR ROAD RED FIELD POST COIMBATORE PIN -641018
Provn of store room and demolition of T-173 and T-174 at 6AFH
2023_MES_617991_1
8928_E8
Open Tender
Civil Works
Item Rate
180 days
AFAC
As per NIT and tender documents
7 documents required · 7 mandatory
₹500
AGE I AF COIMBATORE
₹18,000
Yes
3 Nov 2023
11 Sept 2023
30 Oct 2023
11 Sept 2023
23 Oct 2023
25 Sept 2023
11 Sept 2023 - 15 Sept 2023
Amount
Provn of store room
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5 m in depth and getting out in hard/dense soil .
Returning ,filling in ,including spreading ,levelling,watering and well ramming in layers not exceeding 25cm in hard dense soil.
Removing surplus excavated soil to a distance exceeding 5 km but not exceeding 15 km and depositing where directed
Plain cement concrete 1:4:8 type D2 using 40 mm graded stone aggregate as in foundations ,fillling and mass concrete.
M&L for RCC design mix M-25 (20mm graded aggregate) in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete
M&L for RCC design mix M-25 (20mm graded aggregate) in Columns, pillars, piers, posts and struts
M&L for RCC design mix M-25 (20mm graded aggregate) in Beams, cantilevers, bressummers, lintels over 1.5m span
M&L for RCC design mix M-25 (20mm graded aggregate) inchajjas etc.
M&L for flat formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surfaces of concrete.
M&L for flat formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished surfaces of concrete.
M&L for flat formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. for rough finished surfaces of concrete.
M&L for flat formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n.exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide .
M&L for flat formwork to chullah hoods, chajjas, troughs and similar items including edges for rough finished surfaces of concrete.
M&L for TMT bars 10 mm dia over cut to length,bent to shape required ,including cranking ,bending spirally for hooping for columns,hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia.
All as above, but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders
Precast cement concrete block masonry with solid blocks exc 10 cm in width in PCC 1:2:4 type B-1 and setting in cement mortar 1:4 all as specified
M & L Rendering in CM 1:3, 5mm thick on fair faces of brick work or concrete surfaces on ceiling complete all as specified.
M & L for preparation of newly plastered surfaces and applying three coats of white wash on ceiling.surface all as specified.
M&L for Rendering with WPC in CM 1:4, 15mm thick on othe than fair faces of brick work or concrete surfaces all as specified and directed. Note : WPC shall be measured and paid separately
Supply only Intergral waterproofing compound
M&L for Rendering in CM 1:6, 10mm thick on fair faces of brick work or concrete surfaces all as specified and directed.
M & L prepaeation newly plastered of wall surfaces and applying two coats of acrylic smooth exterior paint of required shade (applied @ 1.67ltr/10 Sqm) over and including priming coat of exterior primer @2.20 Kg/10 Sqm) all as specified .
M & L prepation of newly plastered wall surfaces and applying two coats of distemper oil emulsion over over a coat of primer over 3mm thick wall care putty on wall all as specified and as directed .
M&L for 100mm thick Cement concrete type D- 2, 1:4:8 (40mm graded aggregate) in sub base of floor
M & L 40mm thick Cement concrete type B-0, 1:2:4 (12.5 mm graded aggregate)
All as per item No 26 above but as in skirting/Dado
Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge.
Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge.
Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer- in-charge.
S&F 12 mm Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work
S&F stainless steel wire cloth 00.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless stell wire staples.
S&F 3 mm figured glass, ordinary quality , n exc 0.5 sqm in each glass all as specified and directed.
M&L for treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured)
M&L for treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface.
M&L for treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area
Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.
Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165
All as above item No 40 but for portions framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc.
Supply, laying and testing cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cables heavy duty with stranded aluminium conductor 1100 volts grade of size 2 core 16 sq mm complete all as specifed and directed .
M&L for riddled earth filling in trenches above and below the cable as in cable protection. Note:- Punned thickness shall be mesured and paid.
Supply and laid well burnt bricks sub-class 'B' designation 75 for cable protection, brick shall be laid dry flat as width of brick eqals to the length of cable and the gap between two adjacent brick shall not exceeded 10 mm, complete all as specified and as directed.
Material and Labour for GI pipe 32 mm dia light grade with all fittings for cable protection laid under road/path/hard standing or fixed with wall/ pole etc complete
M&L for concealed Point wiring one light point controlled by one, one way switch complete with 1.5 sqmm single core PVC insulted FRLS cable 1100 volts grade multistranded copper conductor drawn through in and including 20mm dia PVC rigid non metallic conduit concealed with all accessories such as internal bend, end caps etc complete concealed in walls and surface in ceiling/roof/etc including 1.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade with multistranded copper conductor cable as earth continuity conductor including fabricated branded modular metal flush box concealed in walls with suitable modular plate with cover with suitable screws for housing switches, socket outlets, fan regulators etc all as specified and as directed. Note: Cutting chases and making good in wall / floor will be Measured and paid seperately.
All as per item No 46 here-in-before but one exhaust fan point controlled by one, one way switch.
All as per item No 46 here-in-before one 05 Amps socket outlet point on same board.
All as per item No 46 here-in-before one 05 Amps socket outlet point on independent board.
All as per item No. 46 described here-in-before but with copper conductor cable FRLS, 2.5 Sqmm for one 3 pin socket outlet, 15 Amps and including 2.5 Sqmm PVC insulated copper conductor cable as earth continuity conductor on independent board.
Supply and fix ceiling rose surface type bakelite 65 x 50mm with three terminals.
S&F Switch Modular 6A single pole, one way, 1 module complete all as specified and as directed.
S&F Switch Modular 16A single pole, one way, 1 module complete all as specified and as directed.
S&F Socket, 6A - 2/3 pin combined 2 module complete all as specified and as directed.
S&F Socket 6A/16A - 2/3 pin combined 2 module complete all as specified and as directed.
Supply and fixing LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. Make-Havells/Bajaj/Crompton
S & F LED light fitting 1x9W/1X10Wbulkheadluminaires including LED light driver holder connecting up with three core flexible copperconductor cable of suitable size. Make-Havells/Bajaj/Crompton
S &F modular white cover plate with frame 2 module
S &F modular white cover plate with frame 3 module
S &F modular white cover plate with frame 6 module
S &F modular white cover plate with frame 8 module
S &F modular metal flush box 1/2 module
S &F modular metal flush box 1/3 module
S &F modular metal flush box 6/8 module
Supply and fix exhaust fan, steel bodyAC single Phase. 230V of size 300msweep with, blades, and frame andlouvers
Supply and fix MCB DB, SPN, 8 ways, Isolated neutral bar with single door IP54 protection, door earthing arrangement with cement spill protector, mechanical impact strength IK09 complete. Make: L&T/Legrand/ Havells
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of SPN and current carrying capacity 32 AMP, in the MCB DB Complete with connection testing and commissioning.
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning.
M & L Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate at a depth not less than 1.5 M below ground level, earth plate surrounded by 15cm thick and packed with layers of charcoal dust and common salt , earth lead GI wire 4mm dia ( 8 SWG) connectd to GI earth plate elcectrode by means of bolts, nuts, check nuts, washers of galvanised iron, thimbles and other end of earth wire connected to main switch board and protected by galvanised iron pipe medium grade 15mm bore and 20mm bore medium grade GI pipe with funnel and wire mesh for watering including necessary excavation and earth works. PCC Chamber in cement concrete 1:3:6 type C-2 & RCC cover in M-20 (Design mix ) and all as shown in Electrical Plate No. 3 of SSR ( Part-I) of 2009. (i) The unit rate includes earthing wire, and protection pipe upto 7.5 metre.
M&L for 4 mm dia galvanised iron or steel wire as earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as required complete.
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills,sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring,etc., and making good, cutting not exc 10 cm girth
Demolition of T-173 & T-174
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings
Dismantling wrought iron or mild steel work of any description not otherwise provided for
Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including frmames and cover fillets etc.
Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level)
Demolition of Brickwork or stone/ boulder masonry, built in lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles
Taking down Chowkhats or frames (without taking off shutters from the frames) not exc. 1.5 sq. m each
Taking down Chowkhats or frames (without taking off shutters from the frames) exc. 1.5 sq. m but n exc 4 sqm each
Taking up or down steel tubing and connections, and removing to store for taking in account of credit for 15mm bore complete all as specified and directed.
All as per item No 80 above but for 20 mm bore
All as per item No 80 above but for 25 mm bore
Removing excavated material beyond 5 KM upto 15 km and depositing where directed.
Removal of debris/building material out side the campus including loading and unloading, etc to a distance exc 5Km but n exc 10 km out side the MD land complete all as specified and directed. Note:- Location and permission of depositing the building materials/debris disposal outside the MD land shall rest with contractor at his own arrangement.
Taking down old unserviceable pint wiring (light, fan, socket or power) complete including fixtures and fittings such as switches, ceiling rose, pendents, regulators, sockets, light fittings etc. removing materials for keeping for taking credit .
Disconnecting electric connection and taking down main switch/DB of any size incl MCB and keeping for taking credit
p.chinnasamy
Sri ASK Constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .