| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.6 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹4.7 L+₹8,263 (1.80%)Rejected-Finance | L2 | Rejected-Finance 2ND LOWEST | |
| 3 | Rejected-Technical 1057 1241 ABOVE BANK OF BARODA ABID COMPLEX GOVIND PRASAD JHARPADA BHUBANESWAR KHURDA KHORDHA ODISHA 751006 | KHORDHA | ODISHA | 751006 | - | Rejected-Technical NOT QUALIFIED |
Tender Value
Refer Docs
EMD Value
₹5,000
Closing Date
23 Jul 2022, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SUPERINTENDING ENGINEER
ELECTRICITY URBAN DISTRIBUTION CIRCLE, BUNGLOW NO.-9, OLD POWER HOUSE COLONY, RAILWAY STATION ROAD, GORAKHPUR
Emergency maintenance works due to Natural Disaster
2022_PVVNV_711773_1
16/EUDC(G)/2022-23
Open Tender
Electrical Works
Lump-sum
365 days
AREA OF EUDD-II GKP
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
SUPERINTENDING ENGINEER EUDC
₹5,000
19 Sept 2022
29 Jun 2022
25 Jul 2022
29 Jun 2022
23 Jul 2022
29 Jun 2022
Amount
Loading, unloading and safe carriage of following materials from Store Centre, Gorakhpur to JE dump Store and JE dump Store to work site with proper stacking :-
11/0.4 KV 25 KVA Transformer
11/0.4 KV 63 KVA Transformer
11/0.4 KV 100 KVA Transformer
PCC pole 8.5 meter long
STP pole 11/9 meter long
ACSR Dog Conductor
ACSR Weasel Conductor
Aerial Bunch Cable
11 KV Top Channel
11 KV Dropper Angle
11 KV S/S Base
33 KV Disc insulator with fitting
33 KV Pin insulator with fitting
11 KV Disc insulator with fitting
11 KV Pin insulator with fitting
33 KV Cross Arm
11 KV Cross Arm
T-off channel (125X65X1300) mm
The excavation of foundation pit of size 750mmX450mm and having depth of 1/6th of the full length of the pole. Fabrication & erection of Pole with fixing of necessary clamps & accessories as per required. All required materials such as Holding clamp/STP/LT clamp, F-Bracket, LT shacle insulator, Nuts & Bolts off size etc will be provided by the contractor. Grouting of Pole in cc 1:4:8 (Cement, sand & 40 mm brick ballast), Grouting will be done in the block of size 450x450 mm x depth upto ground level and backfilling of pits with mud completely and leveling etc (Material provided by Contractor). In case of ST Pole making Plinth around Pole height 300 mm above ground level with top 100 mm is kept tapered so that no rainwater gets accumulated on the top. All work will be done as per RESPO norms & relevent IS Specification.
PCC pole 8.5 meter long
STP pole 11 meter long
STP pole 9 meter long
Laying, stringing, sagging, binding and jumpering of conductor for LT/11 KV/33KV Line with providing and fixing of LT Clamps/other clamps, Shackle insulator and nuts&bolts off size by the contractor as per required.
ACSR Dog/Weasel Conductor
Aerial Bunch Cable
Dismantling and again stringing, sagging, binding and jumpering of old existing conductor for LT/11 KV/33KV Line after erection of pole, Providing and fixing of LT Clamps/other clamps, Shackle insulator and nuts&bolts off size by the contractor as per site requirement.
ACSR Dog/Weasel Conductor
Aerial Bunch Cable
Replacement of broken/damaged following material/fitting of 33 KV/11 KV Line complete in all respect (Material will be provided by Department)
33 KV Disc insulator with fitting
33 KV Pin insulator with fitting
11 KV Disc insulator with fitting
11 KV Pin insulator with fitting
Replacement of broken/damaged following material/fitting of HT/LT Line complete in all respect which will be supplied by contractor
LT Shackle Insulator
Holding clamp
Painting of Pole by double coating Aluminum & Red oxide paint. Paint will be provided by contractor
Erection, commissioning & Testing of 25/63/100 KVA T/F on Double Pole with all accessories including make its LT and HT connection.
Jointing of broken conductors/AB cables using jointing sleeves or using phase wire/conductor
Repairing of damage/Rusted Steel Tubular Pole by digging of pit around pole of size 1.0 mtr.X 1.0 mtr.X1.0 mtr. is to be done for proper position and then cleaning of rust and descaling with the help of hard wire brush & chisel and then Putting 3 Nos. 1 mtr. long Angle of size 50x50x6 mm, properly welding on 3 circle with pole. After completing of above work Grouting and Plinthing 300 mm Above level with cement concrete and sand and bricks ballast. After that Painting of ST Pole by double coating Aluminium & Red oxide paint. (All material, labour and T&P will be provided by the Contractor)
Disconnection /Reconnection of consumer cables
Dismantling of STP pole 11/9 meter long and safe loading, unloading and carraige of dismantled material from work site to departmental store
Lopping & Chopping of tree branches and disposal of the same at suitable place for clearance of HT/LT line
Lucky Crane Service
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .