Karnataka Power Transmission Corporation Limited
RAJU H G
Providing 02 Nos of additional 11kV PCVCB for load bifurcation of existing feeders at 66/11kV Tumbekere S/s in Mandya Taluk and District on PTK basis (CALL-02) (Reserved for SC Category)
KPTCL/2024-25/SS/WORK_INDENT2180/CALL-2
KPTCL/2024-25/SS/WORK_INDENT2180/CALL-2
Reserved
Sub-Station
Two Tender Document System(Two Cover)
KPTCL CEE Transmission Zone Office Mysuru
17 documents required · 14 mandatory · 3 optional
Past Experience Documents (if any) such as LOI or LOA, DWA, Work Done Certificate, Performance Certificates from KPTCL and Non-KPTCL in last 05 years as per KW-1 (not compulsory)
valid Super grade Electrical Contractor License issued by the Government of Karnataka as on the date of opening of techno-commercial bid (refer 2.3 of ITT)
Construction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awarded
Reports on the financial standing of the tenderer, such as profit and loss statements and auditors reports for the last five years as per 3.10(iv) of ITT.
Qualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awarded as per 3.10(xv) of ITT.
3.6: Tenderers who meet the above specified minimum qualifying criteria, will only be qualified, if their available tender capacity is more than the total tender value. The available tender capacity will be calculated as under:Assessed Available Tender Capacity: (AxNx1.5-B)Where A-Maximum value of works executed (KPTCL & Non-KPTCL) in any one year during the last five years (updated to FY 2024-2025) taking into account the completed as well as works in progress.
3.7: Even though the Tenderers meet the above criteria, they are subject to be disqualified if they have:- Made misleading or false representations in the forms, statements and attachments submitted in proof of the qualification requirements and/or- Record of poor performance such as abandoning the works, not properly completing the contract, inordinate delays in completion, litigation history, or financial failures etc. and/or- Participated in the previous Tender for the same work and had quoted unreasonably high Tender prices and could not furnish rational justification.
Valid Caste Certificate in support of reserved tender participation
Minimum Average Annual Turnover (MAAT) of the bidder for best two years out of last preceding five financial years ending on March or December as the case may be, shall not be less than Amount put to Tender (ABT) as per 3.2(a) of std tender documents(ITT).
as per 3.10(iv) of ITT
Bidder shall ensure that soft copies of No Deviation CERTIFICATE, Letter of Undertaking, as revised in Annexure , Any other undertaking / agreement (if applicable) are uploaded besides submitting the Originals to the office of the Chief Engineer, Electy., Operation, KPTCL, Mysore, after the last submission date and on or before the date & time of opening of techno commercial bids.
The bidder should furnish the works on hand details as per 3.10(v) of ITT.
Bidder shall ensure that soft copies of i. Letter of undertaking for Non performance ii. Letter of undertaking for Risk and Cost iii. Letter of undertaking for Litigation iv. Letter of undertaking to source the supply of equipment material from KPTCL approved Vendors only (if applicable) are uploaded besides submitting the Originals to the office of the Chief Engineer, Electy., Operation, KPTCL, Mysuru, after the last submission date and on or before the date and time of opening of techno commercial bids as per 3.10(xviii) of ITT
i. Letter of undertaking to source the equipment/material for the work from the approved Vendors who meet the eligibility clauses regarding restrictions on procurement from a country which shares a land border with India (Annexure-XVI) ii. Letter of undertaking as per clause No.1.5 of Annexure-XVII iii. Letter of undertaking as per clause No.1.6 of Annexure-XVII (if applicable) are uploaded besides submitting the Originals to the office of the Chief Engineer, Electy., Operation, KPTCL, Mysuru, after the last submission date and on or before the date and time of opening of techno commercial bids.
Valid ESI certificate
Valid EPF Certificate
Bidder shall upload selfdeclaration stating that no such actions against the bidder haven been taken by KPTCL in the last 6 months as on date of bid submission invoking Risk & cost, failing which the offer is liable to be rejected (refer clause 3.10(ii) of ITT.
Any other required documents as per the terms and conditions of the tender.
Shall be uploaded besides submitting the ATTESTED xerox copies of same to the office of the Chief Engineer, Electy., Operation, KPTCL, Mysuru, after the last submission date and on or before the date and time of opening of techno commercial bids.
₹500
₹8,927
21 Jun 2025
21 Jun 2025
17 Jul 2025
2 Jul 2025
30 Jun 2025
Providing 02 Nos of additional 11kV PCVCB for load bifurcation of existing feeders at 66/11kV Tumbekere S/s in Mandya Taluk and District on PTK basis
11kV 400A, Double break GOS.
11kV 400A, Single break GOS.
LA’S 9KV,10KA class for DP Structures, Station type(Metal Oxide type).
11kV Epoxy Busbar insulators with nut & bolts suitable(10mm) for LA GI Flat supporting.
11kV class PVC insulated Copper control cables with Lugs/ferrules /Glands as per the technical specifications
a)19 core 2.5 Sq mm (for Annunciation)
b) 4 core 6 Sq mm (for CT,PT &DC Connection)
c) 2 core 2.5 Sq mm ( for AC supply)
75 mm dia (outer) 2 mm to 2.5 mm thick
Coyote ACSR Conductor
Tension clamp for single coyote ACSR conductor 70/90KN 16mm
Disc insulator 90kN
CT Treminal connector ( Drake-Coyote) ACSR conductor.
C Type Wedge connector (Coyote- Coyote) ACSR conductor. / T-Clamp (Coyote- Coyote)
Coyote pad clamps
Earth bond 450mm long ( for GOS & CT)
9.0mtr RCC Pole for DP structure 145 KG WL
DP Set (2 Pole Strucrure Kit) as per IS-1977 For RCC Pole - 9 Mtr Long, 145KG WL - GI
H frame set for GOS mounting
A.Grounding of equipments by providing cast iron pipe of 100mm ID 13mm thickness, 2.75 Mtrs long with 2 part clamp out of G.I.Flat 50X6mm continuously welded all-round the pipe using cast iron welding...
Earthing name plates for new earting pits
Galvanised Bolts & Nuts of Various Sizes
Multi Function Transducers(MFT)
As per KPTCL Std, Interface: RS-485 Daisy Chain to RTU Com port,wiring: Both 3ph 4wire, supply: self powered, Measuring range voltage: 120%, current: 120%, frequency: 4...
Input Vtg:110V DC, input indicated by LED, input range 110VDC to 140V DC, sourcing Vtg output 48VDC, No of iputs: 12, No of outputs: 8, Source current: 5mA, at output, 8way switch to be p...
Terminal Blocks (knife type) (8 TB's per Feeder) = (8x2 nos = 16)
Current Cable - 2.5 Sq-mm multistrand copper wire for CT termination
(Each color 15mtrs-R-Y-B) (15mts x 3 x 2 feeder = 90mtr)
Voltage Cable - 2.5 Sq-mm multistrand copper wire for PT termination
(Each color 5mtrs-R-Y-B-N) (5mts x 4 x 2 feeder = 40mtr)
Control Cable - 10 Copper core x 1.5sqmm
(From remote contol desk to RTU) (16mtrs x 2 nos = 32 mtrs)
Signal Cable - 10 Copper core x 0.5sqmm
Feeder to Feeder loop = 16mts x 2 nos =32 mtrs) Remote control desk to RTU (for DI): 16mtrs x 2 Nos. = 32 mtrs
1.5 Sqmm Grey wire for interfacing of DI and DO (20 mtrs for each panel)(20x2=40mtr)
Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the size 2.5 sqmm (80 lugs/panel x 2 = 160)
C-type channel of size 50x100x50x6mm (50cm/panel) = (0.5m x 2 nos = 1 Mtrs)
Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (Size: 32mm dia)
CT TB's - 6 nos for each panel (2 x 6 = 12 nos)
11 KV Switchgear for Feeder panel: 11 KV PCVCB, 500MVA, 25KA, 1250A Incomer 800A feeder with scada compatible features.
Annunciation & Remote control panel (1IC+4F)
11kV 400A, Double break GOS.
11kV 400A, Single break GOS.
LA’S 9KV,10KA class for DP Structures, Station type(Metal Oxide type).
a)19 core 2.5 Sq mm (for Annunciation)
b) 4 core 6 Sq mm (for CT,PT &DC Connection)
c) 2 core 2.5 Sq mm ( for AC supply)
Coyote ACSR Conductor
DP Set (2 Pole Strucrure Kit) as per IS-1977 For RCC Pole-9 Mtr Long, 145KG WL-GI
H frame set for GOS mounting
A.Grounding of equipments by providing cast iron pipe of 100mm ID 13mm thickness, 2.75 Mtrs long with 2 part clamp out of G.I.Flat 50X6mm continuously welded all-round the pipe using cast iron welding...
B. Supplying & Providing 450 mm dia 450 mm height 1.5" to 2" thick hume pipe collar (non pressure type) for earth pits including all lead and lifts etc.
C. Grounding of equipment with 50x6mm G.I. Flat and connecting Equipment to the earth mat/ground pit. Each point of earthing with all formation works like bending, twisting, drilling of holes and c...
Earthing name plates for new earting pits
Loading and unloading of poles, switchgear and other materials etc
Multi Function Transducers(MFT)
As per KPTCL Std, Interface: RS-485 Daisy Chain to RTU Com port,wiring: Both 3ph 4wire, supply: self powered, Measuring range voltage: 120%, current: 120%, frequency: 4...
Input Vtg:110V DC, input indicated by LED, input range 110VDC to 140V DC, sourcing Vtg output 48VDC, No of iputs: 12, No of outputs: 8, Source current: 5mA, at output, 8way switch to be p...
Control Cable - 10 Copper core x 1.5sqmm
(From remote contol desk to RTU) (16mtrs x 2 nos = 32 mtrs)
Signal Cable - 10 Copper core x 0.5sqmm
Feeder to Feeder loop = 16mts x 2 nos =32 mtrs) Remote control desk to RTU (for DI):16mtrs x 2 Nos. = 32 mtrs
1.5 Sqmm Grey wire for interfacing of DI and DO (20 mtrs for each panel) (20x2=40mtr)
CT TB's - 6 nos for each panel (2 x 6 = 12 nos)
Miscellaneous items like, Ferrules, cable ties, insulation tape, & Labour for cutting, weldind, drilling, etc
Configuration of RTU and Engineering along with validation of data at SLDC
11 KV Switchgear for Feeder panel: 11 KV PCVCB, 500MVA,25KA, 1250A Incomer 800A feeder with SCADA compatible features with Current transformer of Ratio 200-100/1-1A
Testing & Commissioning: Wiring: ...
b) For additional 11kV panel
Wiring & Assisting in Testing and Commissioning: 11kV Switchgear
Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution li...
Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes...
Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with supe...
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by r...
Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/w...
Removing the existing jelly and respreading after the completion of work (Entire earth mat area) as per direction of Engineer in charge.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
Work on Hand details format (Tender).doc
Others - works on hand • 0.06 MB
Tumbekere pcvcb BOM.pdf
Others - Bill of Materials • 0.12 MB
Tender documents - Tumbekere PCVCB.docx
Tender Document • 0.37 MB
Volume II A and B.zip
Technical Information / Worksheet • 19.98 MB
NIT -Tumbekere 11kV PCVCB SC CAll-02 udpated.pdf
Others - NIT • 0.64 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .