Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
Refer Docs
Closing Date
13 Nov 2025, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CPO-STEEL
This Tender is for SUPPLY AND ERECTION FOR CANOPY AT RETAIL OUTLETS UNDER NORTH
2500023607-HD-09050
5100023607
Open Tender
Two Bid
Unknown (Unspecified Location)
13 Nov 2025
22 Oct 2025
13 Nov 2025
13 Nov 2025
22 Oct 2025 - 6 Nov 2025
29 Oct 2025
| Item No | Item Title | Description | Qty | Unit |
|---|---|---|---|---|
| 1 | STRUCTURAL STEEL FOR | STRUCTURAL STEEL FOR — DESCRIPTION => Supplying, transporting, fabricating,erecting inposition in position of Pre- fabricated steelstructures at all elevations for Canopy using structuralsteel sections ISMB/ISMC/ISA conforming to IS:2062 and IS226 , including cutting, weldingor bolting, supply ofbolts/nuts/washers etc., complete as per drawingsincludingsurface preparation and applying one coat of ZincPhosphatePrimer before erection, one coat after erectionand two coats ofsynthetic enamel paint as per specificationafter erection and allmaterials and labour complete. ( Nowelding is permitted at site). Therate quoted shall includecost of bolts, nuts, washers, welding andelectrodes and anyother consumables required for completing the work.Nutbolts shall not be considered for payment.Theoretical wightof steelsections shall be considered for payment..(.(Nomeasurement shall betaken for nut,bolt,washer splice plate<(>&<)> gusset plate) | - | Metric ton |
| 2 | ROOFING CLIPPON | ROOFING CLIPPON — DESCRIPTION => Supply and fixing Clippon RoofingSystem:Roofing base material should be of cold rolled steelof 0.55 mm thick and conformto ASTM:A 446 having yieldstress of 275 MPA . The coating should beAluminum and Zincalloy comprising 55% Al, 43.5 Zinc <(>&<)> 1.5 %Silicon, asper ASTM :A 792 . The coating mass should not be lessthan150 Gms per SqM (total of both sides). For, baregalvalume, TCTshould not be less than 0.55 mm. Sheets shallhave approved side lapswith top sheets facing away from theprevailing weather. Necessaryprofiled filler box should beprovided at higher level of roof sheetingand at valleygutter to ensure water tightness in the profiled gaps . Thefixing of roofing shall be done in such a manner thattheroof is not drilled / punctured for fixing with thepurlins .Referto the approved makes given in theAttachment. Flashings, Cappingsand trims: These shall beformed out of same substrates as that of theroofing sheetsand shall be supplied in standard lengths of 2.5 M intherequired shapes and girths and fixed by means ofhex-head mechanicallygalvanized stitching screws. Siliconsealant non-hardening neutral curetype shall be applied atall laps to avoid water seepage. | - | square meter |
| 3 | FALSE CEILING | FALSE CEILING — DESCRIPTION => Providing <(>&<)> fixing false ceilingsystem of Trac150 F exterior grade or approved equivalentof 0.5mm thick galvanisedsteel with stove enameled coilcoated finish inter locking ceilingpanels, carriers,suspension system and edge closure as per thefollowingspecification. Supplying and installation of exteriorgrade150 F ceiling system comprising of 150 mm x 17 mm deeppanels rollformed out of 0.5 mm galvanised steel with stoveenameled coil coatedfinish. The panels shall be pre-treatedand coil coated on one side inmanufacturers standard colourshades as approved by the Architect/Engineer in charge. Therear side of the panel shall be given a coat ofprimer and awash coat while the finished side shall be given a coatofprimer and finish colour coat in polyster paint for amin. dry filmthickness of 20 microns, fixed on to the rollformed carriers 34.5 mm x488 mm deep out of 6 mm thickGalvanised steed with prongs to holdpanels in the module of150 mm at maximum 1.2 mts. C/C. The carriersto be suspendedfrom roof truss by rigid suspension angles aspermanufacturer's recommendation. Panels shall be suppliedin customlength upto maximum of 5 mts. Job also includesproviding ceilingflashing using factory formed 0.5 mm thickPolyster coated galvanisedsteel material. Rate shall beincluding providing flashing to cover gapif any betweenilluminated banding and false ceiling. | - | square meter |
| 4 | MS FASCIA | MS FASCIA — DESCRIPTION => Supplying and fixing 20 SWG GI sheet faciaincludingpainting with one coat of zinc chromate primer andtwo coats of 1 stquality synthetic enamel paint on frontside . Necessary facia frameworkfor fastening the sheet tothe canopy securely shall be paid separately. | - | square meter |
| 5 | AL GUTTER | AL GUTTER — DESCRIPTION => Providing and fixing 2 mm thick AluminumSheet Gutters of required shape in slope with 40 mm x 3 mmMS. Brackets at1000 mm maximum spacing and 8 mm dia G.I. Jor L hooks, boltsand nuts,GI Limpet and bitumen washers,providing nut bolt joint , sealing thejoints with siliconsealant testing the gutter for leakage by fillingwater etc.Complete.(Refer attached Drawing .For allowabletolerancerefer to IS codes | - | meter |
| 6 | UPVC GUTTER 450mm Wi | UPVC GUTTER 450mm Wi — DESCRIPTION => Providing and fixing 3 mm thick UPVC GuttersThegutters shall be installed according to the provideddrawings, ensuringproper alignment, slope, and secureattachment to the supportingstructure. All joints betweengutter sections must be sealed usingsilicone sealant thatis compatible with uPVC materials. It is crucialthat nobolting or hot work methods are used for joining thesections ofthe gutter. The use of such methods is strictlyprohibited to maintainthe integrity of the system. Supportfor the gutter sections shall beprovided using appropriatemounting brackets or supports, ensuring thatthe systemremains secure and functional. These supports mustbeinstalled with the use of bolting.Once the installationis complete, the entire system must undergo aleakage test.This will involve filling the gutter system with watertoensure that no leakage occurs from any of the joints orconnections. Thetesting procedure should confirm thesystem's reliability andfunctionality, ensuring that thereare no visible signs of leakage undernormal conditions. | - | meter |
| 7 | LED FIXTURE 80 W | LED FIXTURE 80 W — DESCRIPTION => 80 W LED Fitting as mentioned in ISstandards IS16101 to 16107::Supply and fixing of 80 W LEDhoused by Single piecePressure Die Cast Aluminum body,recess mountable fitting withguaranteed burning hours of50000 .MakePhilips/Havells/Bajaj/Wipro/Osram/Crompton/GE/BeverInno vations. IP Protection of minimum IP 65 and above,suitable for canopy lighting at retail outlets(Petrolstation) .The bidder should submit copy of certifiedphotometricreport as per IESNA LM-79(Approved method forthe Electrical andPhotometric Measurements of Solid-StateLighting Products) from a UL/ERTL /ERDA or any NABLaccredited laboratory to validate thephotometric claims as<(>&<)> when asked by HPC. A minimum 3 yearswarranty frommanufacturing defects for the luminaire bymanufacturer.i)With high lumen efficacy LEDs from CREE,Seoul Semi-Conductor, LumiledPhilips, Osram, Nichia(Japan), Tridonic (Austria), GE and Bridgelux .Efficiencyof more than 90 lumens per watt . LEDs used in thefixtureshould be from the same bin and certified as perLM-80 (IESNA: ApprovedMethod for Measuring LumenMaintenance of LED Light Sources and LEDlumen depreciationtime to L70 based on LM-80 data). by any UL/ ERTL/ERDA orany NABL accredited laboratory to validate thephotometricclaims as <(>&<)> when asked by HPC.ii) Bottomopen able for easymaintenance.iii)High QualityPolycarbonate Opal Diffuser for Optimumuniformity and Glarefree light output.iv) General electrical protectionagainstHigh Voltage and Surges up to3 KVv) Power factor > 0.95vi)Rangeallowed for total system wattage 80 W with +2W or -2Wvii) DriverOperating Voltage Range: 140 V- 270 V viii)Operating Temperature 0to +45 Deg Centigrade viii) CRI morethan 70 ix) Colourtemperature5650K±500K (to be mentioned inLM 79 certificate) x)Wide beam angle xi)Luminaire Note :that cost of cutting of false ceiling is also included inthe item cost along with supply and fixingof linearlight.Performance Complies to IS10322 (Part 5/Sec 3)<(>&<)> IEC 60598-1,IEC60529, ROHS | - | Each |
| 8 | LINEAR LED FIXTURE 8 | LINEAR LED FIXTURE 8 — DESCRIPTION => 80 W LED Fitting as mentioned in ISstandards IS10322 Part 5/Sect 2: 1967:Supply and fixing of80 W LED housed by Extruded Aluminium Alloy (1.1 mmThickness minimum), Aluminium end cap shall be Die-cast<(>&<)> withOpal white Polycarbonate diffuser (1.2 mmThickness minimum ) bodylenth 2400MM +/- 15mm, recessmountable fitting with guaranteed burninghours of50000.Make-Philips/Havells/Bajaj/Wipro/INNOTRONIX/ALUDECOR /NINJAS.IPProtection of minimum IP 67 and above, suitable for canopylightingat retail outlets (Petrol station) .The biddershould submit copy ofcertified photometric report as perIESNA LM-79(Approved method for theElectrical andPhotometric Measurements of Solid-State LightingProducts)from a UL/ ERTL /ERDA or any NABL accredited laboratorytovalidate the photometric claims as <(>&<)> when asked byHPC. A minimum5 years warranty from manufacturing defectsfor the luminaire bymanufacturer.i) With high lumenefficacy LEDs from Nichia / Cree / Osram/ Philips (Lumiled)/ Seoul/Bridgelux/Samsung/ Tridonic (Austria), GEandBridgelux .Note: that cost of cutting of false ceiling isalso included in the itemcost along with supply and fixingof linear light. Efficiency of morethan 100 lumens per watt. LEDs used in the fixture should be from thesame bin andcertified as per LM-80 (IESNA: Approved Method forMeasuringLumen Maintenance of LED Light Sources and LEDlumendepreciation time to L70 based on LM-80 data) by anyUL/ ERTL /ERDA orany NABL accredited laboratory to validatethe photometric claims as<(>&<)> when asked by HPC.ii)Bottom open able for easy maintenance.iii)High QualityPolycarbonate Opal Diffuser for Optimum uniformity andGlarefree light output.iv) General electrical protection againstHigh Voltage and Surges up to3KV) Power factor > 0.95vi)Range allowed for total system wattage 80 W with +2W or-2Wvii) Driver Operating Voltage Range: 140 V- 270 Vviii)Operating Temperature -10 to +50 Deg Centigradeix) CRI morethan 70x) Colour temperature5700K(+350) (to be mentioned inLM 79 certificate)xi)Wide beam anglexii)Highly EfficientSilicon Encapsulated IP 67 Driver > 85% for wattage<(><<)>=40W > 87% for wattage > 40W Single driver for eachfitting.Detailed Specification sheet attached.PerformanceComplies to IS10322 (Part 5/Sec 3) <(>&<)> IEC60598-1,IEC60529, ROHS | - | Each |
| 9 | 4CX2.5SQMM COPPER CA | 4CX2.5SQMM COPPER CA — DESCRIPTION => Supply and laying following size PVCinsulated,sheathed, armoured cable of approved makeconforming to IS 1554:Part1:1988 4CX2.5SQMM COPPER CABLE | - | meter |
| 10 | 4CX2.5 SQMM END TERM | 4CX2.5 SQMM END TERM — DESCRIPTION => END TERMINATION End termination of followingcable withdouble compression NFLP gland and crimpingsockets 4CX2.5 SQMM ENDTERMINATION | - | Each |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
2500023607-HD-09050.pdf
TENDER_DOCUMENT • 35.96 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .