Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-Finance | ₹1.2 Cr | L1 | Accepted-Finance Quoting Lowest rate |
| 2 | L2₹1.4 Cr+₹25.5 L (21.7%)Rejected-Finance | ₹1.4 Cr+₹25.5 L (21.7%) | L2 | Rejected-Finance Quoting Higher rate |
| 3 | L3₹1.5 Cr+₹31.8 L (27.0%)Rejected-Finance | ₹1.5 Cr+₹31.8 L (27.0%) | L3 | Rejected-Finance Quoting Higher rate |
| 4 | L4₹1.5 Cr+₹34.4 L (29.2%)Rejected-Finance 19 LAKE TEMPLE ROAD KOLKATA 700029 | KOLKATA | WEST BENGAL | 700029 | ₹1.5 Cr+₹34.4 L (29.2%) | L4 | Rejected-Finance Quoting Higher rate |
| 5 | L5₹1.5 Cr+₹36.3 L (30.8%)Rejected-Finance 86 TOLLYGUNGE CIRCULAR ROAD KOLKATA WEST BENGAL 700053 | KOLKATA | KOLKATA | WEST BENGAL | 700053 | ₹1.5 Cr+₹36.3 L (30.8%) | L5 | Rejected-Finance Quoting Higher rate |
Tender Value
Refer Docs
EMD Value
₹3.5 L
Closing Date
7 Jun 2023, 3:00 pmClosed
Superintending Engineer
Office of the Superintending Engineer, Western Electrical Circle , PWD, Purta Bhavan, 1st floor, Burdwan-713103
Proposed Construction of Collectorate Complex at Kalyanpur Housing for the office of the District Magistrate, Paschim Bardhaman----- SITC of VRF Air-Conditioning System..
2023_WBPWD_533437_1
WBPWD/SEWEC /AED /NIQ-06/2023-24-2nd Call
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
Kalyanpur
Please refer Tender documents.
5 documents required · 5 mandatory
₹3.5 L
Office of the Superintending Engineer, Western Ele
31 Oct 2025
23 May 2023
9 Jun 2023
23 May 2023
7 Jun 2023
26 May 2023
23 May 2023 - 25 May 2023
25 May 2023
Amount
SITC of Air cooled VRF top discharge type Outdoor Unit each comprising of variable speed all inverter controlled scroll/Rotary compressor, air cooled copper condensor with protective coated fins, mounting frame, micro processor control panel and other standard accessories according to OEM standard. The unit shall be suitable for operation with R-410A refrigerant. Minimum EER at 100% load & at minimum 35 degree centigrade ambient condition should not be less than 10 (Ashree standard table 6.8.1 L). Nominal capacity of outdoor units in BOQ at climatic condition of kolkata taking into consideration of ambient correction factor as per OEM standard to deliver inside temparature condition @24 ±2 degree centigrade. The outdoor unit should either be a single module or combination of multiple modules and each of the module should contain multiple variable speed inverter type scroll or rotary compressors. The rate is inclusive of anti vibration foot pad, Y conectors at ODU side if any.(Make-Mitsubishi / Blue Star / Toshiba /Hitachi / Carrier/ Voltas / Daikin)
Supply, Installation, Testing & Commissioning of Ceiling Suspended Compact type(as per site condition) Indoor Units for VRF system & allied accessories : (Make-Mitsubishi / Blue Star / Toshiba /Hitachi / Carrier/ Voltas / Daikin)
5.6 KW cooling capacity indoor unit with 540 CFM or better with minimum three steps speed regulator, with chorded remote and noise level less than 38 db.
7 KW cooling capacity indoor unit with 720 CFM or better with minimum three steps speed regulator, with chorded remote and noise level less than 38 db.
Supply, Installation, Testing & Commissioning of Refrigerant copper "Y" Joints with copper brezing with nitrile rubber insulation of adequate thickness.
SITC of the of following nominal size of hard drawn/soft drawn copper refrigerent piping System including vaccumiazation and Nitrogen of testing for VRV/VRF AC system, complete with fittings, with adjustable ring type hanger supports, jointing/ brazing including accessories as required at site & approved by EIC, duly insulated with XLPE class -O tubular closed cell elastomeric nitrile rubber insulation (Make : Armacell/ K-flex/ Aeroflex/ A-flex) of 13mm thickness upto 15.9 mm OD Cu pipe & above 19mm thick insulation for higher sizes Cu pipes.
Ф41.3 MM(17.5 SWG or 1.3 mm) (Hard Drawn)
Ф38.1 MM(17.5 SWG or 1.3 mm)(Hard Drawn)
Ф34.9 MM(18 SWG or 1.2 mm)(Hard Drawn)
Ф28.6 MM(19 SWG or 1 mm)(Hard Drawn)
Ф25.4 MM(19 SWG or 1 mm)(Hard Drawn)
Ф22.2 MM(19 SWG or 1 mm)(Hard Drawn)
Ф19.05 MM(19 SWG or 1 mm)(Hard Drawn)
Ф15.9 MM(19 SWG or 1 mm)(Hard Drawn)
Ф12.7 MM(21 SWG or 0.8 mm)(Hard Drawn)
Ф9.53 MM(21 SWG or 0.8 mm)(Soft Drawn)
Ф6.35 MM(21 SWG or 0.8 mm) (Soft Drawn)
Supply and Laying of Rigid PVC Drain Pipe (Medium Class)with respective fittings ,proper supports at 5 feet interval and duly insulated with 6 mm thick closed cell nitrile rubber insulation. (Make : Oriplast/ Supreme/ Filolex/ Ashirbad/ Astral)
25 mm dia
32 mm dia
Supply and charging of R410A refrigerant gas for entire system including Testing and commissioning of complete VRV system including all indoor units,outdoor units,electricals,remotes etc including pressure testing with nitrogen & vaccumasation.
Supply & Fixing of perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support. With 25x25x3mm angle iron support.
200x50x1.25mm (18SWG)
300x50x1.25mm (18SWG)
Supply, erection & installation of fabricated MS Structure comprised of 'I'section Beam , 'C' channel, MS flat etc for platform suitable for mounting Outdoor unit including painting by anti-corrosive paint over RO primer including wall cutting, grouting with cement concrete, as per direction of EIC.
Supplying and fixing 4 way Polycarbonate make enclosure with IP-65 protection, provision for four pole RCCB , to be fixed on wall (Make: Syntex/ Supreme/ Hensel) mending goods the damages to original finish incl. painting, inter-connection & provision for earthing attachment. incl. S&F of FP 32A, 300mA sensitivity RCCB.(Make: Legrand/ABB/SIEMENS/L&T)
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 25mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required
4x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC
Supplying & Laying of flexible shielded copper control cable of 4C 2.5 Sq.mm & 20mm size PVC 'FR' type Rigid Conduit for interconnection between the indoor units and the outdoor units, wiring through 20mm size PVC 'FR' type Rigid Conduit.
Supply & Fixing 240 V,20 A, 3 pin plug top with indicator (Brand approved by EIC) & necy. Connections.
Terms and condition
The Agency must procure the materials from the Manufacturer / OEM or from their authorised sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them.
Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent upon award of the contract from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution, of work/submission of bill.
If any refurbished material is supplied and installed, penal action will be taken as per existing rules
2. Any pre-bid query shall have to be brought into notice of this office for deviation/correction if any with due recommendation of TIA.
JASODA REFRIGERATOR SERVICING CENTRE
ADS ENGINEERS
Shinryo Suvidha Engineers India Pvt. Ltd.
Lyric International
Auto-Tech Projects Pvt.Ltd.
AUTO-TECH AIRCONDITIONER
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .