RequiredExperience with Government
RequiredAnnual Turnover
RequiredCertificate (Requested in ATC)
RequiredOEM Authorization Certificate
RequiredOEM Annual Turnover Bid to RA enabled No Note: 1. OEM Turn Over Criteria: The minimum average annual financial turnover of the OEM of the offered product during the last three years
Requiredending on 31st March of the previous financial year
Requiredshould be as indicated in the bid document. Documentary evidence in the form of certified Audited Balance Sheets of relevant periods or a certificate from the Chartered Accountant/Cost Accountant indicating the turnover details for the relevant period shall be uploaded with the bid. In case the date of constitution/incorporation of the OEM is less than 3 year old
Requiredthe average turnover in respect of the completed financial years after the date of constitution shall be taken into account for this criteria. ICU Bed ( 24 pieces ) Technical Specifications 1/11 * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) Standard Parameter Conformity to standard for safety & electromagnetic compatibility IEC-60601-1-2:2001 Standard or IS-13450 IEC-60601-1-2:2001 Standard or IS-13450 Performance Parameter Purpose ICU Bed are required to be used in Intensive Care Unit for comfort of Patient & facilitate comfortable transfer to & from Emergency/OT Ward etc. & also to carry out point of care process including Radio- logical procedure at bed side ICU Bed are required to be used in Intensive Care Unit for comfort of Patient & facilitate comfortable transfer to & from Emergency/OT Ward etc. & also to carry out point of care process including Radio- logical procedure at bed side Type of ICU Bed Actuator Electro-Mechanical (Motorized ) Electro-Mechanical (Motorized ) Type of mechanism for functioning or controlling angular motion of bed part Hydraulic mechanism (Motorized) Hydraulic mechanism (Motorized) Type of mechanism for functioning or controlling Height of bed Super Smooth Crank Screw Mechanism Super Smooth Crank Screw Mechanism Number of section provided in Bed Top 4 * Base frame and support frame should be fabricated using metallic square rectangular section of adequate cross section and thickness to provide high structural strength and stability Yes * Bed top perforated Yes Yes Bed should have radio translucent top (X-Ray translucent) Yes Yes Availabilty side panel/Side safety guard Yes * Type of side panel Collapsible type Collapsible type Number of Side panel 2 2 Availability Head & Yes * 2/11 Foot panel/Board Shape of Head & Foot panel/Board B-type shape B-type shape Type of Head & foot Panel Detachable type Detachable type Material of head and foot panel ABS (acrylonitrile- butadiene styrene) * Availability of good grip for head/foot or side panel Yes * Slots for IV rod at four corners provided Yes * Number of hooks provided in IV rod 2 2 Availability of rectangular telesccopic tube box housing for tension spring Yes Yes Degree Angle & Height indicator shall be provided at both foot & head side Yes Yes X-Ray film holder used from One side One side Type of X-Ray Film holder Cassettle Based System * Power of motor in HP(for non motorized put NA) 0.5 hp 0.5 hp Better quality bearing should be used Yes * Avaiability of patient constraint belt provided on both side of bed yes yes Availability of Noiseless
Requirednon rusting swivel castor wheel roller with for easy Mobility & Steering yes * Facility of braking and locking mechanism provided in castor roller Yes * Number of caster to which braking system provided 2 2 3/11 Availiability Corner buffer in all four corner to protect patient from collision shock Yes * Safe working load capacity of ICU bed in kg 150 150 Facility of instant non powered/mechanical CPR( Cardiopulmonary Resuscitation) release at the head end for emergency Yes * Lilen Holder/Urine Bag holder provided Yes * Accessory Rail Provided at all four side of bed Yes * Mattress provided with ICU bed Yes Yes ICU mattress must X- ray translucent Yes Yes Mattress foam of the Bed should be with Anti Microbial agent incorporated into all components that assists in Prohibiting growth of bacteria & fungi and easy to clean Yes * Mattress shall be made of High resilient & bio- density foam Yes Yes Mattress should be translucent to allow radiography using portable X-ray machines Yes Yes Mattress should be made in cube cut design & independent cubes promote air flow to reduce moisture Yes Yes Material for ICU Bed Mattress Latex Foam Latex Foam Maximum thickness of Mattress in mm with tolerance of ± 2 mm 100 * Approx foam Density 40 * 4/11 for Head/sacrum in kg/m3 tolerance Approx foam Density for Heel in kg/m3 30 * Therapeutic Weight limit for mattress in kg 150 150 Operating temperature & humidity for ICU bed 10 -40 Deg C and relative humidity of 15-90% * Power Supply ( as appropriate fitted with Indian plug) Single phase 230 Volt
Required50 Hz ( AC Supply ) Single phase 230 Volt
Required50 Hz ( AC Supply ) Facility of Resettable overcurrent breaker shall be fitted for protection Yes Yes ICU Bed frame and top must be Rust Proof Yes * Type of powder/Paint coating done to ICU Bed frame
Requiredtop & side panel Epoxy Polyester Coating 50-60 microns * ICU Bed should be made up of high quality metal
Requiredpretreated with materials providing good finish
Requiredscratch resistant
Requiredbacteriostatic coating Yes * Process used for pre chemically treatment of metallic bed component Dip tank processes * Facility of easily cleaning/maintenance to ICU Bed Yes * Warranty in years 3 3 Product instruction manual shall be supplied Yes * Standard Tool Kit for maintananace and Trouble Shooting to be provided with ICU bed Yes * Demonstration of working to be provided after completing supplies before Yes * 5/11 Acceptance Dimensional & Material Parameter Material for the frame of bed SS SS Material for side railling/Side Safety guard MS MS Material for Head & Foot Panel/Board MS MS Material for Bed top Section MS MS Material of wheels Polyester Polyester Material for IV rod with chromium plated SS SS Maximum Adjustable Back Rest Angle in Degree 0-70 0-70 Maximum Adjustable Knee Rest Angle in Degree 0-40 0-40 Diameter of Castor Roller in mm 130-150 * Maximum Trendlenburg Angle in Degree with tolerance ±2 degree 10 10 Maximum Reverse Trendlenburg Angle in Degree with tolerance ± 2 degree 10 10 Bed height adjustibility range in mm 500-900 * Mean coil diameter of tension spring used in counter weight mechanism in mm 40 40 Spring coil diameter used in counter weight mechanism in mm N/A for Super Smooth Crank Screw Mechanism & Hyraulic mechanism for height N/A for Super Smooth Crank Screw Mechanism & Hyraulic mechanism for height Clearance between Bed Base frame and Floor surface in mm 120 120 Length of bed in mm with 2% tolerance 2000-2100 2000-2100 Width of bed in mm with 2% tolerance 1000-1050 1000-1050 6/11 Weight of ICU Bed in Kg 120 * Additional Parameters Spares ICU Bed Mainframe supplied 2 2 Spares Pair of Bed Ends
Requireddetachable supplied 2 2 Spares Collapsible side rails supplied 1 1 Spares IV Rods supplied 1 1 Spares Matress simmilar to one supplied with ICU bed 1 1 Reports Certifications for Product European CE European CE
RequiredBIS Electric Shock Protection level- Class-B/class-1 Yes Yes Availability of ISO certification with manufacturer Yes * ISO certification Number and Date if ISO certificate not availiable then put NA - * Copies of test Reports/certificates and other certifications to be furnished to buyer on demand at time of supplies Yes * * Specifications highlighted in bold are the Golden Parameters. * Bidders may note that In respect of non-golden Parameters
Requiredthe specifications 'Values' chosen by Buyer will generally be preferred over 'Bid requirement ( allowed Values) by the Buyer.