Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.7 LAccepted-AOC | L1 | Accepted-AOC Award of Contract | |
| 2 | L2₹39.9 L+₹1.3 L (3.39%)Rejected-Finance | L2 | Rejected-Finance Not Being Lowest | |
| 3 | L3₹42.1 L+₹3.5 L (9.12%)Rejected-Finance | L3 | Rejected-Finance Not Being Lowest | |
| 4 | L4₹42.3 L+₹3.7 L (9.69%)Rejected-Finance | L4 | Rejected-Finance Not Being Lowest | |
| 5 | L5₹42.4 L+₹3.9 L (10.0%)Rejected-Finance | L5 | Rejected-Finance Not Being Lowest |
| Sl No | Description | Qty | Unit | Ms. S.K. ASSOCIATES L2 | R. T. Saluji L7 | BHAVIN INFRA L4 | Mangesh Murlidhar Darwade L1 | M/s. Nida Group L6 | m/s shivam tools and equipment L5 | M/s. Shahabad Enterprises L3 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches n' exc 1.5 m wide and n' exc 1.5 m in depth and n' exc 10 Sq m on plan and getting out in Soft / loose soil all as directed. | 500 | Cum | 125 ₹62,500 Lowest | 145 ₹72,500 | 135 ₹67,500 | 130 ₹65,000 | 140 ₹70,000 | 135 ₹67,500 | 130 ₹65,000 |
| 2.00 | .-ditto- all as per serial item No 1 above but in Hard / dense soil. | 90 | CUM | 145 ₹13,050 | 140 ₹12,600 Lowest | 150 ₹13,500 | 160 ₹14,400 | 150 ₹13,500 | 150 ₹13,500 | 145 ₹13,050 |
| 3.00 | Returning, filling in excavated material (soil) including spreading, levelling, watering and well ramming in layers not exc 25 cm all as directed. | 530 | CUM | 80 ₹42,400 | 100 ₹53,000 | 93 ₹49,290 | 60 ₹31,800 Lowest | 95 ₹50,350 | 85 ₹45,050 | 95 ₹50,350 |
| 4.00 | Removing excavated material to a distance n' exc 50 m and depositing where directed at a level n exc 1.5 m above the starting point all directed. | 60 | CUM | 100 ₹6,000 | 105 ₹6,300 | 130 ₹7,800 | 80 ₹4,800 Lowest | 125 ₹7,500 | 95 ₹5,700 | 100 ₹6,000 |
| 5.00 | Repairs/ rectification of GI Pipe/UPVC pipe leakage by replacing short piece length upto 0.50 mtr in wall/floors etc and excavation upto 1 cum as in trenches and including providing unions, reducers,nipples etc and making necessary connections to make it functional complete all as specified and as directed for following pipe of dia. (a) 50mm bore | 20 | Each Job | 400 ₹8,000 | 410 ₹8,200 | 400 ₹8,000 | 220 ₹4,400 Lowest | 405 ₹8,100 | 410 ₹8,200 | 420 ₹8,400 |
| 6.00 | (b) 40 mm bore | 20 | Each Job | 450 ₹9,000 | 450 ₹9,000 | 440 ₹8,800 | 150 ₹3,000 Lowest | 455 ₹9,100 | 490 ₹9,800 | 470 ₹9,400 |
| 7.00 | (c) 25 mm bore | 40 | Each Job | 290 ₹11,600 | 305 ₹12,200 | 315 ₹12,600 | 130 ₹5,200 Lowest | 300 ₹12,000 | 315 ₹12,600 | 305 ₹12,200 |
| 8.00 | (d) 20 mm bore | 60 | Each Job | 250 ₹15,000 | 290 ₹17,400 | 270 ₹16,200 | 110 ₹6,600 Lowest | 285 ₹17,100 | 260 ₹15,600 | 250 ₹15,000 |
| 9.00 | (e) 15 mm bore | 40 | Each Job | 210 ₹8,400 | 230 ₹9,200 | 215 ₹8,600 | 60 ₹2,400 Lowest | 220 ₹8,800 | 215 ₹8,600 | 220 ₹8,800 |
| 10.00 | Taking up or down GI steel tubing and connections from trenches / walls / floors etc cleaning for re-fixing for following pipe of dia complete all as specified and as directed. (a) 80mm bore | 300 | RM | 25 ₹7,500 | 28 ₹8,400 | 30 ₹9,000 | 40 ₹12,000 | 50 ₹15,000 | 30 ₹9,000 | 15 ₹4,500 Lowest |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
28 Nov 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineers (North) Ahilyanagar
Military Engineer Services Garrison Engineers (North) Nagar Pathardi Road Ahmednagar Fort Ahilyanagar 414 002
REPAIR/ REPLACEMENT OF CORRODED CI/GI WATER SUPPLY PIPELINE OF ER ROAD OFFCR QTRS AND MAP QTRS IN AC DEPOT, ACHARYA SINGH ENCLAVE, MOTIBAGH, TARAPORE ENCLAVE UNDER GE (N) AHILYANAGAR
2025_MES_738763_1
8151/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
Garrison Engineers (North) Ahilyanagar
As per NIT
8 documents required · 8 mandatory
₹500
Yes
Garrison Engineers (North) Ahilyanagar
₹88,000
Yes
19 Feb 2026
7 Nov 2025
1 Dec 2025
7 Nov 2025
28 Nov 2025
21 Nov 2025
Amount
Excavation in trenches n' exc 1.5 m wide and n' exc 1.5 m in depth and n' exc 10 Sq m on plan and getting out in Soft / loose soil all as directed.
.-ditto- all as per serial item No 1 above but in Hard / dense soil.
Returning, filling in excavated material (soil) including spreading, levelling, watering and well ramming in layers not exc 25 cm all as directed.
Removing excavated material to a distance n' exc 50 m and depositing where directed at a level n exc 1.5 m above the starting point all directed.
Repairs/ rectification of GI Pipe/UPVC pipe leakage by replacing short piece length upto 0.50 mtr in wall/floors etc and excavation upto 1 cum as in trenches and including providing unions, reducers,nipples etc and making necessary connections to make it functional complete all as specified and as directed for following pipe of dia. (a) 50mm bore
(b) 40 mm bore
(c) 25 mm bore
(d) 20 mm bore
(e) 15 mm bore
Taking up or down GI steel tubing and connections from trenches / walls / floors etc cleaning for re-fixing for following pipe of dia complete all as specified and as directed. (a) 80mm bore
(b) 50 mm bore
(c) 40 mm bore
(d) 25 mm bore
(e) 20 mm bore
(f)15 mm bore
Supply and fix GI pipes, medium grade including necessary fittings such as sockets, elbows, tees, reducers, unions, nipples etc laid in trenches / walls / floors etc for following pipe of dia complete all a s specified and as directed. (a) 80mm bore
(b) 50mm bore
(c) 40mm bore
(d) 25mm bore
(e) 20mm bore
(f) 15 mm bore
Supply and fix in repairs gun metal gate valve/ brass stop valve, high pressure both ends screwed down with crunch or butterfly handle with suitable size sockets on both ends nipples, unions, etc suitable for following GI pipe of dia complete all as specified and as directed. (a) 50mm
(b) 40 mm bore
(c) 25 mm bore
(d) 20 mm bore
(e) 15mm bore
Taking up cast iron / ductile iron/RCC/PVC pipe water mains with Spigot and socket ends having lead / tyton joints including all fittings and burning out joints, removing lead for following pipes of dia complete all as specified and as directed. (a) 100 mm bore
(b) 150 mm bore
(c) 200 mm bore
(d) 250 mm bore
(e) 300 mm bore
Supply and laying ductile iron pipes with Spigot and socket ends centrifugally K-7, in any length, laid in trenches for following pipes of dia complete all as specified and directed. (a) 100 mm bore NOTE : Tyton joints required are deemed to be included in the unit rate quoted.
(b) 150 mm bore
(c) 200 mm bore
(d) 250 mm bore
(e) 300 mm bore
M&L for cast iron / ductile iron specials such bends of any type, radius and angle, tapers any type, straight, bend, increasing, decreasing or double socket etc, tail pices single branch, "Y" junctions, double branch, cross (all sockets or socket and spigot) collars, caps and plugs etc suitable for CI / DI pipes class LA upto 300 mm more pipes complete all as specified and as directed.
M&L for Run lead joint complete and pressure testing complete all as specified and directed of the following sizes :- (a) 80 mm bore
(b) 100 mm bore
(c) 150 mm bore
(d) 200 mm bore
(e) 250 mm bore
(f) 300 mm bore
Supply and fixing in repairs mechanical joints, non extendable type with rings, nuts, bolts & washers etc for following bore CI / DI pipes complete all as specified and as directed. (a) 80 mm bore
(b) 100 mm bore
(c) 150 mm bore
(d) 200 mm bore
(e) 250 mm bore
(f) 300 mm bore
Supply and fixing in repair Key for operated sluice valve with good quality GI pipe 2 mtr length properly welded for following dia complete all as specified and directed. (a) 80 mm
(b) 100 mm bore
(c) 150 mm bore
(d) 200 mm bore
(e) 250 mm bore
(f) 300 mm bore
Supply and fixing in repairs of graphite gland packing for sluice valve for following dia bore complete all as specified and as directed.. (a) 80 mm
(b) 100 mm bore
(c) 150 mm bore
(d) 200 mm bore
(e) 250 mm bore
(f) 300 mm bore
M&L for opening of unserviceable sluice valves, cleaning the serviceable parts, adjusting of moving parts, greasing, re-assembling of valve and fixing to the desired position with and including replacement of rubber gaskets, nuts, bolts, washers, gland packing, Brass Checknuts and SS Spindle suitable for following dia of sluice valve complete all as specified and as directed. (a) 80 mm
(b) 100 mm bore
(c) 150 mm bore
(d) 200 mm bore
(d) 250 mm bore
(e) 300 mm bore
Supply and fix in repairs cast iron sluice valve , Class PN1.6, ISI marked with stainless steel spindle, both ends flanged including rubber gasket, nuts, bolts and washers complete all as specified and as directed for following pipes of dia.80 mm bore
(b) 100 mm bore
(b) 150 mm bore
(c) 200 mm bore
(d) 250 mm bore
(e) 300 mm bore
Dismantaling old valve chamber and M & L for Construction of PCC solid block valve chamber including earth work described as under complete all as specified for the following internal size as under : (a)100 mm thick hard core, (b)PCC foundation 1:4:8 type D2 (using 40 mm graded stone aggergate) (c) 200 mm thick block masonary graded C-5 built in CM 1:6, (d)15 mm internal and external plaster in CM 1:4, (e)3mm thick MS sheet chamber cover and 50 x 50 x 5 mm thick angle iron frame including painting with two coats of synthetic enamel paint over one coat of red oxide primer on all exposed surface including locking arrangments. (a) Internal Dimension 1500 mm x 1200 mm x 1000 mm
All as per above Sr Item No. 74 but of size (b) Internal Dimension 1500 mm x1000 mm x 1000 mm
S& F in repairs high pressure polythelene float valve with PVC ball suitale for fixing to GI pipe of 25 mm dia all as specified and directed.
S& F in repairs high pressure polythelene float valve with PVC ball suitale for fixing to GI pipe of 20 mm dia all as specified and directed.
S& F in repairs high pressure polythelene float valve with PVC ball suitale for fixing to GI pipe of 15 mm dia all as specified and directed.
Drilling and tapping cast iron / ductile iron water mains, in position, for branch connections of the internal dia 20 to 50 mm all as directed.
M &L for Cement concrete in foundations,of Type B2 1:2:4 40mm Stone aggregate in filling and mass concrete for disturbed surface on roads complete all as specified and directed by Engr-in-charge.
Supply and fixing of Reinforced concrete pipes of dia 150mm, class NP2, laid and jointed complete with collars including with cemented joints testing and all as directed by Engr-in-charge.
NOTE for item nos 01 to 81 :- (i) The contractor/his supervisor will report the office on 09.00 clock morning every day including any holidays to collect the complaints from JE and will render the completion within 12 hours failing which 500 Rupees per day will be charged as an penalty & the same will be recovered from contractor. (ii). The contractor and his supervisor will provide the mobile number so that they can be communicated about the complaints, the SMS will be sent on those mobile and will be treated as an official complaints. The contractor will render the completion in writing to the department within 12 hours hours failing which 500 Rupees per day charged as penalty.
An amount of Rs 2,88,775.00 shall be deducted from BOQ on account of schedule of credit
Ms. S.K. ASSOCIATES (BID ID -3483941)
M/s. Shahabad Enterprises (BID ID -3483569)
BHAVIN INFRA (BID ID -3491487)
m/s shivam tools and equipment (BID ID -3484786)
M/s. Nida Group (BID ID -3483565)
R. T. Saluji (BID ID -3488749)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.24 MB
BOQ_827213.xls
BOQ • 2.46 MB
PS8151.pdf
Tender Documents • 1.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .