Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.0 LAccepted-AOC THE RETREAT NEAR LAKE BORDOLOI NAGAR P O TINSUKIA ASSAM PIN 786 125 D 69 CEEC | TINSUKIA | ASSAM | 786125 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹50.6 L+₹97,166.13 (1.96%)Rejected-Finance | L2 | Rejected-Finance NOT BEING L1 | |
| 3 | L3₹51.1 L+₹1.4 L (2.80%)Rejected-Finance P O WEST SRIPURIA DIST TINSUKIA ASSAM PIN 786 145 | TINSUKIA | ASSAM | 786145 | L3 | Rejected-Finance NOT BEING L1 | |
| 4 | L4₹51.3 L+₹1.7 L (3.37%)Rejected-Finance | L4 | Rejected-Finance NOT BEING L1 | |
| 5 | L5₹51.7 L+₹2.1 L (4.13%)Rejected-Finance KAJANIBARI DINJAN PO DINJAN DIST TINSUKIA ASSAM786189 | DINJAN | TINSUKIA | ASSAM | 786189 | L5 | Rejected-Finance NOT BEING L1 |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
20 May 2024, 6:00 pmClosed
GE DINJAN
GE DINJAN, PANITOLA (PO), DIBRUGARH (DIST), ASSAM PIN-786183
SPECIAL REPAIR TO BLDG NO P-57 (1-8) MD ACCN AT SECT A AND PROVN OF WATER COOLER AND RO PLANT (SPL ITEM) AT SARGAM SHOPPING COMPLEX AT DINJAN MIL STN UNDER GE DINJAN
2024_MES_650069_1
C/8643/E8
Open Tender
Civil Works - Others
Item Rate
180 days
DINJAN MIL STN
AS PER TENDER DOCUMENTS
10 documents required · 10 mandatory
₹500
GE DINJAN
₹86,000
Yes
15 Jul 2024
15 Apr 2024
27 May 2024
15 Apr 2024
20 May 2024
7 May 2024
Amount
Demolition of cement concrete (un reinforced) in ground floors and paving n. exc. 15 cm thickness (below or above ground level) removing rubbish off the premises etc complete all as directed.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for, removing rubbish off the premises etc complete all as directed.
Taking down chowkhats or frame with shutters (without taking off shutters from the frame) not exceeding 1.50 Sqm each complete all as directed.
Taking down chowkhats or frame with shutters (without taking off shutters from frames) exceeding 1.5 Sqm but not exceeding 4 Sqm each complete all as directed.
Excavating in trenches not exc 1.5m wide and not exc 1.5m in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sqm on plan and n exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed.
Materials and Labour for plain cement concrete (1:4:8) type D-2, using 40mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed.
Materials and labour plain cement concrete Type B1, 1:2:4 (using 20mm graded stone aggregates) as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs , water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed inclusive of necessary form work complete all as specified and directed.
Materials and Labour for RCC with type B1 (1:2:4) (using 20 mm graded stone aggregate ) in Slabs supported on walls , beams and columns in floors , roofs ., landings, balconies , canopies, deck slabs and in shelves and the like complete all as specified and as directed. (Note: Steel reinforcement shall be measured & paid separately)
Providing precast cement concrete Type B0 (1:2:4) (using 12.50 mm graded aggregate) as in louvres and jallies, 25mm thick (measured solid), including all mouldings but excluding frame set in cement mortar (1:4) complete all as specified and directed.
Demolition of brickwork, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as directed.
M&L for brick work with sub class 'B' burnt clay bricks straight or curved on plan exc 6 meter mean radius built in cement mortar 1:6 complete all as specified and as directed.
M&L for brick work with sub class 'B' burnt clay bricks straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and as directed.
Cutting chases, pinning in brick wall making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc and cutting chases for concrete water tubing or concrete conduit wiring etc and making good, cutting not exc 10cm girth complete all as specified and as directed.
Supply and fixing for 2nd class hard wood small fittings such as brackets of any type latch or hinge blocks shaped door & window stops & the like, incl. all necessary labours, articles n. exc. 200 Cu cm each complete all as specified and directed.
Materials and Labour for formwork to soffits of suspended slabs such as roof slab, floor slabs, landing covers, and similar works, for rough finished flat surfaces of concrete, thickness of slab not exc 200 mm, complete all as specified and directed.
Supply and fix 20 mm thick, second class hard wood boarding, planed one sides with butt joints and fixed complete in position as in eaves board, etc complete all as specified and directed.
Supply and fixing for 4 mm thick HPSC non asbestos fibre cement Standard Ceiling board (decorative type, Ocean) with powder coated exposed GI grid suspension system (E-Grid T-2430 or equivalent load carrying capacity with mid span deflection not exceeding 1/360 span with hanger spacing of 1200 mm c/c) consisting of Main Runner 3600mm long, Cross Tee 1200mm/600mm long and Wall Angle. The Wall Angle shall be fixed on PVC Dash Fasteners on the perimeter of the wall by steel screws with distance 300 mm c/c. The Main Renners to be placed @ 1200mm, The Cross Tee 1200mm will be inserted in the precut slots of Main Runner at a regular interval of 600 mm to form a modular grid of 1200mm x 600mm. Additional Cross Tee's of 600mm shall be placed perpendicular to the Cross Tee 1200mm long to finally form a grid of 600mm x 600mm. Grid of module size 600mm x 600mm shall be supported by 6mm dia GI wire from purlins/soffit. 6mm thick High Pressure Steam Cured Non Asbestos Fibre Cement Standard Ceiling Board (Density > 1200 Kg/m3) of size 595mm x 595mm, conforming IS 14862 & Type B Category III of ISO 8336, tested as per AS 1530 part 3 & BS-476 Part 4, 5, 6, 7 & 8 should be placed in the Grid module including dismantling of existing ceiling any type all as specified and directed.
Supply and fixing 35mm thick second class class hard wood glazed and skelton shutter, open rebated and prepared to receive glass gauze etc, divided into squares (with sash bar), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass exc., size of members of shutter as specified in SSR part-I, sec 8 clause 8.24(a), supplied and fitted to chowkats, complete all as specified and directed.
Supply and fixing 35 mm thick second class hard wood plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats, complete all as specified and directed.
Supply and fixing Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing, complete all as specified and directed.
Supply and fixing for factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded, plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, panelling of plain colour 5mm thick PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, complete all as specified and as directed by Engr-in-Charge.
Materials and labour in repairs 18/19 mm thick pre-laminated particle board exterior grade pre-laminated one side with decorative choice laminated and other side balancing white lamination fixed with screws to timber frame work as in cup board shutters, partitions and shelves complete as specified and directed.
Supply and fixing Aluminium anodized barrel tower bolts of extruded section, 200 mm long, complete all as specified and directed.
Supply and fixing for 250 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, complete all as specified and directed.
Supply and fixing Mild steel butt hinges, Medium grade, 100 mm size , complete all as specified and directed.
Supply and fixing extruded aluminium alloy handles, fabricated type, anodized, 150 mm size , complete all as specified and directed.
Supply and fixing in repair harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc. complete all as specified and directed.
Supply and fixing stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.18mm and fixed with stainless steel wire staples complete all as specified and directed.
Materials and Labour for TMT bars 10 mm dia and over, as reinforcement for concrete cut to length, bent to shape required including cranking, bending, spirally hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia, complete all as specified and directed.
Materials and Labour for TMT bars 6 to 8 mm dia , as reinforcement for concrete cut to length, bent to shape required including cranking, bending, spirally hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia, complete all as specified and directed.
Supply & fixing mild steel angles or tee sections/hold fast/wind ties fixed independently with connecting base plates etc complete all as specified and as directed.
Supply and fixing framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and conforming to Fe 410-W (Gde-E-250) Quality A complete all as specified and as directed.
Supply and fixing pressed steel frames for doors local work shop made of size 105x60mm with one or more rebates using cold rolled commercial mild steel sheet of 1.2mm thick including providing and fixing necessary lugs, 100mm butt hinges, lock strike plate, shock absorber etc and including PCC filling of hollow section using plain cement concrete (1:3:6) type C1 complete all as specified and as directed.
Supply and fixing pressed steel frames for doors local work shop made of size 125x60mm with one or more rebates using cold rolled commercial mild steel sheet of 1.2mm thick including providing and fixing necessary lugs, 100mm butt hinges, lock strike plate, shock absorber etc and including PCC filling of hollow section using plain cement concrete (1:3:6) type C1 complete all as specified and as directed.
S & F Anodised aluminium powder coating windows and ventilator shutters, (minimum thickness of powder coating 50 micron) side hung type without sash aluminium sections weighing 0.55 kg/m rubber including necessary joining cleats, glazing clips, rudder packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150 mm long hinges type B-2 100mm long - 02 Nos, suitable handle - 1 No including 4 mm thick frosted sheet glass pieces, complete all as specified and directed by E-in-charge.
S & F Aluminium Anodised Grill, design pattern as approved by GE fixed with and including standerd aluminium frame of flat section of size as approved by GE complete all as per manufacturer instruction.
Supply & fixing 0.71mm thick plain, aluminium sheeting, Alloy 31000 H4 in ridges, hips, valley gutter, drip and straight flashing (as in crumple joint) complete all as specified and as directed.
Dismantling floor hearth or wall tiling and stone slabs including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises etc complete all as directed
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc. complete all as specified and directed
M&L for non-skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed or bedding layer of cement mortar in (1:6) for laying floor finishes complete all as specified and as directed
M&L for non-skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in skirting etc. over 10 mm thick back coat of cement mortar in (1:4), set and jointed in neat cement slurry and pointed in white or colour cement to match over complete all as specified and as directed.
M&L for coloured glazed ceramic tiles in vertical surface as skirting, dado and risers to steps etc, of size 450X 300X 7 mm thick over 10mm thick rendering as backing coat in cement mortar (1:4) , set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match, complete all as specified and directed.
M&L for prepolished, chequered cement concrete tiles of size 25cm x 25cm x 22mm thick, as in floors etc, including 15 mm thick screed bed or bedding in cement mortar (1:6) and set and jointed in neat cement slurry and pointed in grey cement and pigments to match with the shade of tiles complete all as specified and as directed.
M&L for granite (of any type) tiles 18-20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete over 15mm thick screed bed in cement mortar (1:4) complete all as specified and as directed.
M&L for 20mm thick granite (of any type) (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platform, and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixure of pigment to match the shade of granite complete all as specified and directed.
Materials and labour for 75 mm thick plain cement concrete (1:3:6) type C1 using 20 mm graded stone aggregate as in sub-base of floors, plinth protection etc. finished the surface of concrete fair and even, complete all as specified and directed.
Materials and labour for 25 mm thick PCC (1:2:4) type B0 using 12.5 mm graded stone aggt as in floors finished even and smooth with using extra cement, complete all as specified and directed.
M&L for water proofing treatment on RCC roof etc. comprising with the following operation & as specified herein below:- (a) Taking down existing old tarfelt, bituminous compound including cleaning & removing debris to a distance exc 100 m n.exc.250m. (b) M&L 25 thick cement concrete type B0 1:2:4( 12.5 mm graded aggregate) finished even and smooth. (c) M&L for 15 mm thick cement mortar in 1:4 finished even and smooth. (d) Preparing & cleaning of fully dried cement plastered surface. (e) Applying one coat of cold bituminous primer to the plastered surface @ 0.25 litres per sqm conforming IS-3384. (f) A layer of APP based polymeric membrane membrane 3mm thick (minimum) weighing 3.5 kg per sqm reinforced with polyster non woven fabric (weighing not less than 160 gms/sqm) shall be applied over bituminous primer as specified above. Application of polymeric membrane shall be by torch application. The over lap shall be minimum 100 mm on transverse direction and 75 mm in longitudinal direction. (g) One coat of aluminium paint over APP membrane @0.11Kg/Sqm. Note:- Prior to execution of the APP Membrane works, leak proof test shall be done by ponding water on roof slab to minimum depth of 25 mm. The entire roof slab shall be flooded with water for 48 hours. The necessary barrier shall be made to make feasible to stagnate water for 48 hours on roof slab.
Taking down cement plaster or lime plaster on walls /ceiling of any description from concrete or brick wall etc including raking out joints, hacking for key, scrubbing down with water and disposing off the retreived debris as directed including necessary scaffoldings etc complete all as directed.
M&L for rendering 15 mm thick on other than fair faces of brick work or concrete surfaces as in walls in cement mortar (1:6) and finished the surfaces even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering 15 mm thick on fair faces of external wall of brick work or stone surfaces in two layers (10 mm and 5 mm thick) in cement mortar (1:4) using water proofing compound in top layer (water proofing compound measured as separately) and finished even and smooth without using extra cement complete all as specified and directed. (Note: WPC shall be measured and paid separately as supply only)
M&L for rendering 5 mm thick on ceiling in cement mortar (1:3) finished even & smooth without using extra cement complete all as specified and directed.
Supply only Liquid water proofing compound complete all as specified and directed.
Material and labour for preparation of new plastered surface etc and applying three coats of white wash on ceiling complete all as specified and directed.
Material and labour for preparing newly plastered surfaces of internal walls, etc and applying two coats of distemper oil emulsion over a coat of primer over 1.5mm thick wall care putty to a smooth surface complete all as specified and as directed.
Materials and labour for preparation of new plastered surfaces and applying two coats of cement based paint over a coat of alkali-resistant primer on wall complete all specified and directed.
Materials and labour for preparation of old plastered or unplastered surfaces of walls and applying one coat of white wash complete all as specified and as directed.
M&L for preparation of old old plastered or unplastered surfaces of ceiling and applying one coat of white wash complete all as specified and as directed.
M&L for preparation old decorated plastered or unplastered surfaces of wall cornices etc and applying two coats of cement base paint (white or tinted) complete all as specified and as directed.
M&L for preparation newly or old decorated external surfaces of wall, chajja, facia etc by complete removing old paints by hand scrubber without disturbing the plastered surfaces broomed to remove all dust, diret and all loose scales of old paints and other foregin matter and applying two coats of water based acrylic weather proof exterior emulsion (Apex ultima superior quality) paint over a coat of primer as per manufacturer's instruction complete all as specified and as directed.
M&L for preparing old plastered or unplastered surfaces of walls by washing, rubbing down and scraping of existing distempering/painted surfaces etc and applying one coat of distemper oil emulsion complete all as specified and as directed.
Materials and labour for preparing of new wooden surfaces of any description , over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and directed.
Materials and labour for preparing of new steel surfaces of any description , over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
Taking up or down 15 mm bore steel water tubings and fittings etc complete and making good disturbed surfaces of walls/ceilings etc for complete including stacking aside for reuse and removal of unserviceable items from site complete.
Taking up or down 20 mm bore steel water tubings and fittings etc complete and making good disturbed surfaces of walls/ceilings etc for complete including stacking aside for reuse and removal of unserviceable items from site complete.
S&F for 20mm bore CPVC tubing med grade with all fitting and fixed complete to walls and ceiling or laid in floors complete all as specified and directed.
S&F for 25mm bore CPVC tubing med grade with all fitting and fixed complete to walls and ceiling or laid in floors complete all as specified and directed.
Supply and fix in repair 50 mm bore, high density polyethylene pipes (HDPE) of pressure rating 6 kgf/ cm2 in waste pipe for WHB and sinks,complete all as specified and as directed.
Supply and fix waste Pipe (PTMT) 32 mm/ 40mm for wash basin and sink complete all as directed by Engr in Charge.
Supply and fixing in repair sinks made of stainless steel 1.0mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and directed.
Supply and fixing in repair stainless steel plate rack, 1mm thick racks of standard qality 900x900x250mm size complete all as specified and directed.
Supply and fixing in repairs sheet corner glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and as directed.
Supply and fixing in repairs semi-pedestal pattern (Anglow-Indian type), vitreous china water closet pan, white, with 'P' or 'S' trap, including flushing pipe, PVC seat and cover, etc complete and making good to disturbed surfaces of floor by filling with PCC (1:4:8) type D-2 to match with the existings complete all as specified and as directed.
Supply and fixing in repairs, PVC low level flushing cistern, 10 litre capacity, valveless, symphonic action type with inlet, ball valve, float and handle incl bracket, PVC conection pipe and flush pipe of polyethylene of low or high density or PVC 32 mm dia, complete all as specified and directed
Supply and fixing in repairs vitreous china wash basin, size 550x400mm, white, flat back including 15mm bore CP pillar tap fancy type, with PVC waste pipe, CP waste coupling, chain, plug and porcelain stopper & brackets including cutting for and pinning in ends of brackets but excluding tap complete all as specified and as directed.
Supply and fixing in repair for 450mm long PVC connections 15mm size with PTMT nuts, complete all as specified and directed.
Supply and fixing in repairs 15 mm bore, bib taps, cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed.
Supply and fixing in repairs 15 mm bore, pillar taps, fancy type, cast copper alloy, chromium plated with capstan heads, screwed down high pressure with or without lettered 'Hot or Cold' with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and as directed.
Supply and fixing in repair 15mm bore dia Stop cock cast copper fancy type chromium plated alloy screwed down high pressure with crutch or butter fly handle serwed both ends for iron pipe or for unions complete all as specified and as directed.
Supply and fixing in repairs 15mm dia angular stop cock cast copper alloy, screwed down high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and as directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as directed.
Supply and fixing PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors, complete all as specified and directed.
Supply and fixing PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors, complete all as specified and directed.
Supply and fixing PVC (SWR) bends any radius 110mm bore with access door, complete all as specified and directed.
S & F for PVC (SWR) bends any radius, 110mm bore complete all as specified and directed.
Supply and fixing PVC (SWR) bends any radius 75mm bore with access door, complete all as specified and directed.
S & F for PVC (SWR) bends any radius, 75mm bore complete all as specified and directed.
S & F for PVC (SWR) reducers, 110mm bore complete all as specified and directed.
Supply and fixing PVC (SWR) junction single, (Single T) equal or unequal, 110 mm bore complete all as specified and directed.
Supply and fixing PVC (SWR) vent cowl 75mm bore, complete all as specified and directed.
Supply and fixing PVC (SWR) junction single, (Single T) equal or unequal, 75 mm bore complete all as specified and directed.
M&L for PVC (SWR) floor trap 75mm dia, plain with grating including jointing with solvent cement including disconnection of old existing trap, and connected with existing water pipe complete all as specified and directed.
Supply and fixing in repairs brass chromium plated shower rose, 125 mm size, with or without swivel joint any size incl fixing to steel pipe or union complete all as specified and as directed
Supply and fixing in repair Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed.
Supply and fixing in repair brass chromium plated tubular towel rail, D type, 60cm long, 20mm dia with brackets complete all as specified and as directed.
Supply and fixing in repair 500 litres capacity rotational moulded polyethylene water storage tanks (cylindrical or vertical with closed top) as per IS 12701:1996, hoisted and fixed in position including provision of 20/15mm bore medium grade pipe for connecting inlet, outlet, overflow and washout pipe complete all as specified and as directed.
Supply and fixing in repair 20 mm bore Gun metal gate or globe valve with iron wheel head screwed both ends for iron pipe complete all as specified and directed.
Supply and fixing in repair Ball valves high pressure of PTMT 20 mm bore with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight - 210 gms), screwed for iron pipe etc complete all as specified and directed.
M&L for opening cover, taking out excreta, sludge, soil from septic tanks/sewage sumps /manholes etc and removing the same to a distance exc 50 mtr but n exc. 100 mtr and burried underground upto minimum 30cm below ground level including necessary excavation of pits and returning, filling and dressing of surplus soil around to slope if required, cleaning the septic tank/ sump and refixing the cover in original position all as directed. Note : (i) bleaching powder @ 1.5 kg/sqm shall be sprinkled over the sludge dumped in pit. (ii) the location of earth pit to be dugged shall be approved by Engr-in-charge. (iii) Cost of excavation for excavated pit and bleaching powder and and deemed to included in unit.
Cleaning of sewage line/pipe (any dia) by rodding in to manhole suitable method to clear the sludge/blocking etc logged in side the sewage line and well flushing with water to drain the loose sludge etc inside the sewage line from manhole to manhole including removing and re-fixing the manhole cover all as specified and directed.
S&F in repair 5mm thick PVC sheet without fillet complete all as specified and directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc complete all as specified and directed.
Taking down carefully aluminium/copper point wiring (light, fan, socket or power) including unserviceable light fittings, switch board complete, switch sockets, ceiling roses, pendants, regulators, sockets, etc and removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed.
Taking down carefully old serviceable main switch, DB's consisting of MCBs wooden/GI/MS sheet board etc for kept in store and for later use all as directed (To be measured only when found serviceable in all respects complete for reuse)
Taking down sub main wiring/ service connections of any size with conduit/casing caping complete including removal from site and making good disturbed surface of walls/floors etc complete all as specified and directed.
Taking down existing unserviceable fluorescent tube light fittings/ street light fittings any type by unscrewing from boards/walls and making good disturbed surface to match with existing finish and all as directed by Engineer-in-Charge.
Taking down carefully serviceable ceiling fans/exhaust fan of any size, deposit in safe costody, after repair work fix in original position after repair complete all as specified and directed.
Taking down carefully serviceable geyser deposit in safe custody, after repair work fix in original position after repair complete all as specified and directed.
Taking down carefully serviceable energy meter deposit in safe custody , after repair work fix in original position after minor repair complete all as specified and directed.
Taking down unsv meter box Supply and fixing Thermoplastic Polystyrene of IP 65, single phase metering cover wall mounted of size 217x253x115 mm with transparent glass and necessary fixing nut ,bolts and clamp for installations of single phase energy meters.Quoted rate includes connectios of respective energy meters at specific locations complete all as specified and directed by Engr-In-Charge. Note-Fixing of Existing meter in the box is included in the quoted rate.
M&L for concealed point wiring with FRLSH PVC insulated unsheathed multistranded copper conductor cables of 1.5 sqmm size alongwith one earth continuity conductor with FRLSH PVC insulated unsheathed multistranded copper conductor cable of 1.5 sqmm size passing through and including suitable PVC conduit with all fittings and accessories of PVC conduit (like Tee, bend etc.) complete fixed to walls /ceiling etc , including cutting chases, making good with cement mortar 1:3, terminated in and including providing PVC/modular metal box of suitable size with 3mm thick hylam sheet cover for fixing of switches, sockets, fan regulators etc for one light/fan/bell/buzzer point controlled by one, one way switches complete all as specified and as directed.
All as per item No 113 above but for one 3 pin socket outlet, 5 Amps on Independent board complete all as specified and as directed.
All as per item No 113 above but for one 3 pin socket outlet, 5 Amps on the same board with other switches complete all as specified and as directed.
All as per item No. 113 above but wiring with cables of size 2.5 sqmm & cables of size 2.5 sqmm as continuous earth wire for one 5/15 Amps switch socket combination on Independent board. One 3 pin socket outlet, 5 Amps, independent board.
Supply and fixing Switch piano, flush type, single pole, one way switch 5 Amps complete all as specified and as directed.
S & F socket outlet 2 in 1, 5 Amp flush type complete all as specified and as directed.
Supply and fixing switch socket combination 2 in 1, 5 Amps flush type complete all as specified and as directed.
Supply and fixing switch socket combination multipurpose 5A /16A, 5 in 1, flush type complete all as specified and as directed.
Supply and fixing for ceiling rose, 3 phase/ PVC/ polycarbonate, isolated body bearing ISI marked and including PVC box complete all as specified and as directed.
Supply and fixing bell push flush type, 5 Amp, 240 volt complete all as specified.
Supply and fixing bell ding-dong, AC 230 V, single pole complete all as specified and as directed.
Supply and fixing electronic step regulator (speed regulation in 5 steps) suitable for ceiling fan 1200 sweep/1400 mm, 120 Watt complete all as specified and directed.
Supply and fixing in repair decorative type surface and wall mounted 20 Watt LED batten light fittings, 4 feet long, with aluminium housing and integrated electronic driver, fixed to walls/ceiling, environmental friendly, energy efficient ready to use pack .
Supply and fixing in repairs 9 Watt surface and wall mounting type LED batten with polycarbonate housing & integrated electronic driver complete all as specified and as directed.
S & F decorative type wall light fittings made of polycarbonate suitable for 10/15 watt retrofit LED including LED 10 watt spiral B22 base as per cat No. LHDL02160099 or equivalent of Make mentioned under Appendix "B" including taking down complete all as specified and as directed.
Supply and fixing for lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed.
Supply and fixing for LED Lamp 9 Watt complete all as specified and as directed.
Supply and fixing MCB Single pole, 240 volts 5 to 32 Amps 10 KA rupturing capacity, C series complete all as specified and directed .
S & F MCB 'C' curve, SPN 6 to 32 Amps with breaking capacity 10 kA complete all as specified and directed .
Supply and fixing MCB 'C' curve, TPN 63 Amps with breaking capacity 10kA Complete all as specifed and directed.
Supply and fixing in repair factory made board distribution (DB) double door in sheet metal enclosure with common bus bar at incomming end, single pole & neutral, 8 way, 240 Volts suitable for housing MCBs including complete all as specified and as directed.
Supply and fixing MCB distrubution board, TPN 4 way, double door, sheet steel, phosphatised, powder coated with 200 amps bus-bar, neutral link, earth bar and din rail, 415 V, complete all as specified and directed by Engineer-in-charge.
M&L for sub main wiring with two run of 6 Sqmm (Nominal area) single core cable PVC insulated, multistranded, unsheathed, copper conductor cables (FRLSH), 1100 Volts grade drawn through PVC casing-caping/conduit of suitable size, fixed to wall/ceiling etc including one run of 6 Sqmm (nominal area) single core, PVC insulated, multistranded, unsheathed, copper conductor (FRLSH) as earth wire and duly connected to common earth point complete all as specified and as directed. Note : (a) PVC Casing-caping/conduit, two run wiring cables and one run of earth wire will be measured as one length (b) All incoming and outgoing cable shall be connected by using proper lugs & sockets.
Supply and fixing in repairs 35/40 Watt LED building security light new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embeded PC cover having Bottom Opening seperate driver compartment with IP66 protection and impact resistance of IK08. including all fixing arrangement and taking down old light fittings of any type complete all as specified and as directed.
M&L for earthing complete with GI earth plate electrode 600mm x 600mm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25m below ground level with the top edge of earth plate at depth not less than 1.5m below ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers protected by 15mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, pre-cast RCC 1:2:4 type B-1, cover slab of size 350x350x50mm reinforced with 8mm dia TMT steel bars @ 15cm centre to centre in both direction and 10mm dia MS handle of suitable size, charcoal or coke and salt in alternative layers, necessary earth work in soft/loose soil all as shown in Electrical Plate No 3 of MES Schedule Part I and testing the base in which pit cover rests made up of MS angle iron (Frame) complete as specified and as directed.
M&Lin repairs test point terminal box made of gun metal or phosphorous bronze, size 75x75x25 mm drilled and screwd including 3 Nos 8 mm dia 25 mm long hexagonal head screw complete all as specified and as directed.
Supply, Laying and testing cable XLPE sheathed, PVC insulated screened PVC bedded, galvanised steel strip of wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 volt grade, laid in trenches/surface of wall/in GI pipe along with pole for connection to OH lines, including brass cable glands, clamps, cross section area 3.5 Core 50 sq.mm complate all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m deep for foundation/cable trench, not exceeding 10Sqm on plan and getting out in soft/loose soil complete all as specified and as directed.
Returning filling in with approved excavated soil including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed.
Removing excavated soils to a distance not exceeding 50 metres and depositing where directed at a level nexc. 1.5 metre above the starting point complete all as specified and directed.
M&L for sand cushioning with dry clean sand 15cm below cable and 8cm above the cable complete all as specified and as directed. Note : Punned thickness shall be measured for payments.
Supply and fixing sub-class B brick, well burnt, laid breadth-wise along the axis of cable laid in trenches over sand cushion laid for UG cable protection, complete all as specified and as directed.
Surface dressing not exceeding 15 cm deep as in soft/loose soil including removing the materials to a distance not exc 50m and spraying pesticides to control grass growth complete all as specified and as directed.
M&L for hardcore of broken brick aggregate of guage n.exc 63mm , deposited, spread and levelled in layers n exc. 15 cm thick, consolidated, watered and rolled/rammed to a true surface complete all as specified.
S&F for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of profile as approved, any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S&F for pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges/valley gutter, fixed with self tapping screws complete all as specified and as directed. Note : Colour of ridge shall be same colour as that of sheet used for roof.
Excavating in post holes (or similar holes) each n.exc 0.5 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layer n.exc 25 cm, watering, and removing surplus soil to a distance n.exc 50 mtr and making good surfaces in hard standing or hard/dense soil complete all as specified and as directed.
S&F for rolled mild steel section as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates and similar work conforming to Fe-410 Gde E-250 quality B, complete all as specified and as directed.
S&F for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to Fe-410 Gde E-250 quality B, complete all as specified and as directed.
M&L for preparation of new steel and iron surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint of approved shade or tint over a coat of red-oxide primer complete all as specified and as directed.
S&F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed.
Supply, installation, commissioning of Water cooler partially stainless steel, electric driven single phase having approx storage capacity 80 litre and nominal cooling capacity 40 litre per hour, complete all as specified and as directed.
M&L for sub main wiring with two run of 4 Sqmm (Nominal area) single core cable PVC insulated, multistranded, unsheathed, copper conductor cables (FRLSH), 1100 Volts grade drawn through PVC casing-caping of suitable size, fixed to wall/ceiling etc including one run of 4 Sqmm (nominal area) single core, PVC insulated, multistranded, unsheathed, copper conductor (FRLSH) as earth wire and duly connected to common earth point complete all as specified and as directed. Note : (a) PVC Casing-caping/conduit, two run wiring cables and one run of earth wire will be measured as one length (b) All incoming and outgoing cable shall be connected by using proper lugs & sockets.
S&F single pole and neutral enclosure with a two pin and earth Plug and socket complete with one single pole MCB of 20 Amps rating complete all as specified and directed
Supply and fixing Reverse Osmosis Plant of out put capacity of 100 Litres per hour consist of the following: Stage 1: Sediment filter (20" length 10 Micron) Stage 2: Bacteriostatic Activated Carbon Block filter (20" length 10 Micron) Stage 3: Reverse Osmosis membranes Stage 4: Ultra Voilet sterilization RO plant should have the following features : (a) Compact unit with robust mild steel powder coated frame (b) Effectively removes upto 90 to 95% of total disolved solids (c) Build in safety features to protect high pressure pump and membrane (d) Capable of handling waters with TDS leves upto 1500 ppm. (e) Water quality monitor: shows the product water quality as TDS (f) Auto flash system complete all as specified and as directed by Engr-in-Charge.
M/S Karen Enterprises
M/S BORAH BROTHERS
M H KHAN
M/S CHANDAN ENTERPRISE
Shree Trilok Electric Corporation
M/S AUTOMOTIVE WORLD
PAUL ENTERPRISE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .