Loading…
Loading…
Tender Value
₹14.8 L
EMD Value
₹29,620
Closing Date
23 Jul 2026, 6:00 pm5d left
EXECUTIVE ENGINEER-ELE.
UDA Office Udaipur
P and F of Mini Highmast and High Power Flood Light at Various Location UDA Area. 2908
2026_UITUD_573803_1
NIT_29_08
Open Tender
Electrical Works
Percentage
120 days
Udaipur
Please Refer Tender Document
2 documents required · 2 mandatory
₹590
Refer Tender Document
₹29,620
Yes
8 Jul 2026
8 Jul 2026
24 Jul 2026
8 Jul 2026
23 Jul 2026
8 Jul 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Item Code [11.2-2025]:Item Type [Electrical] :: Sub Item Code [11.2-2025 + 11.2.4/11.2.4.3]: Providing & Laying XLPE insulated & P.V.C. sheathed Armoured Aluminium cable confirming to IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing commissioning etc. as required of following size. 16.0 Sq. mm/4 core | 300 | Mtr | 256 | ₹76,800 |
| 2 | Item Code [12.13-2025]:Item Type [Electrical] :: Sub Item Code [12.13-2025 + 12.13.1]: P / L of Double wall corrugated HDPE pipe confirming to IS : 16205 P-24, Stiffness Class 750 N, Externally corrugated and having smooth surface inside with HDPE Coupler, Elbow, Tee at required Depth below the ground for laying cable of following Nominal Outer dia. MFR Test report from NABL accrediated is to be submitted.(Excavation of trench, CC Haunching, Back filling of Earth with compaction is to be Paid Extra). 50 mm | 225 | Mtr | 85 | ₹19,125 |
| 3 | Item Code [18.1-2025]:Item Type [Electrical] :: Sub Item Code [18.1-2025 + 18.1.1/18.1.1.8]: Supply and erection of Galvanized Iron pole with galvanizing done in single dipping (Average coating thickness Minimum 65 Microns) continuously tapered poles having Octagonal / Circular/ Conical cross-sections designed to withstand the maximum wind speed as per IS 875, The pole shaft shall be made from sheet steel (HT Steel Conforming to grade S355JO) and confirming to BSEN 10025 and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding. The welding of pole shaft shall be done by Submerged Arc Welding (SAW) process. pole shafts shall be provided with the rigid flange plate of suitable thickness (Fe 410 conforming to IS 226 / IS 2062) with provision for fixing 4 no. foundation bolts, The base plate shall be fillet welded to the pole shaft at two locations i.e. from inside and outside.The octagonal Poles shall have hinged lockable door of approximate 500 mm length at the elevation of 500 mm from the Base plate with bakelite sheet having 6A SP MCB and 16 sqmm stud type connector ( 4 nos) inside the pole at door opening for cable connection of following length and dimension as per table P-01 for Octagonal & P-02 for Conical with base plate and foundation bolt on the Existing cement concrete foundation. To ensure quality of product its entire manufacturing process starting from sheet cutting to galvanization sould be done under one premises. Poles with Octagonal/Conical Cross Section/10 Mtr. | 15 | Each | 22,206 | ₹3,33,090 |
| 4 | Item Code [18.11-2025]:Item Type [Electrical] :: Sub Item Code [18.11-2025 + 18.11.6]: Providing & Fixing of IK08 IP-66 protected high power LED flood light system with single piece Pressure diecast aluminium housing, toughened glass with suitable lenses on LED / integrated lens diffuser to achieve various beam angles, of high power LED of 3 to 5 watt each . Integrated metal case potted driver as a unique BIS R number (as per IS 15885) having efficiency more than 85 % and in compliance to BIS certified and Trade mark certificate(Fitting & driver both have separate BIS R number). The System level Luminaire efficacy >=130 lm/ wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC & Low Voltage cutoff @>=90 V AC and Auto resetting Safety .Power Factor >0.95 , THD(I) <10% , LED driving output current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector , Surge Protection Min >=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K ±355K as required. High Power LED Flood Light Minimum lumen output 19500 lm | 75 | Each | 7,020 | ₹5,26,500 |
| 5 | Item Code [18.2-2025]:Item Type [Electrical] :: Sub Item Code [18.2-2025 + 18.2.2]: Supply and Fixing of Pole OEM fabricated hot dipped galvanised M.S. Overhang (48.3 X 3.25 mm) with cap ( 250x 88.9 / 114.3 x 3.25 mm) over the existing poles. Double arm overhang | 30 | Each | 2,782 | ₹83,460 |
| 6 | Item Code [18.8-2025]:Item Type [Electrical] ::Providing and Laying RCC Foundation for Octagonal / Conical Street Light poles as per Drawing attach at Table P-05 with Following Procedure
A) Excavation of Pit for Foundation Size upto required depth from Ground level
B) Dressing of Pit and Dry stone pitching 200 mm thick including supply of stones and preparing surface complete.
C) Providing and laying in position cement concrete of M-10 grade of 75 mm thickness
D) Reinforcement for R.C.C. work with TMT bars including straightening, cutting, bending, placing in position and binding all complete.
E) Centring and shuttering including strutting , propping etc. and removal of form work for Footing and Pedestal
F) Providing & Fixing of 2 no. Required Size PLB HDPE Pipe & Foundation Bolt with template as per OEM Recommendations.
G) Providing and Laying Reinforce cement Concrete of M-20 grade in Footing and Pedestal including Curing the foundation for minimum 7 days.
H) Providing and Fixing Nosing Angle 25 mm x 25 mm x 3mm with 2 no. of 100 mm long, 6 mm dia fastener
Sub Item Code [18.8-2025 + 18.8.3]: Providing and Laying RCC Foundation for Octagonal / Conical Street Light poles as per Drawing attach at Table P-05 with Following Procedure
A) Excavation of Pit for Foundation Size upto required depth from Ground level
B) Dressing of Pit and Dry stone pitching 200 mm thick including supply of stones and preparing surface complete.
C) Providing and laying in position cement concrete of M-10 grade of 75 mm thickness
D) Reinforcement for R.C.C. work with TMT bars including straightening, cutting, bending, placing in position and binding all complete.
E) Centring and shuttering including strutting , propping etc. and removal of form work for Footing and Pedestal
F) Providing & Fixing of 2 no. Required Size PLB HDPE Pipe & Foundation Bolt with template as per OEM Recommendations.
G) Providing and Laying Reinforce cement Concrete of M-20 grade in Footing and Pedestal including Curing the foundation for minimum 7 days.
H) Providing and Fixing Nosing Angle 25 mm x 25 mm x 3mm with 2 no. of 100 mm long, 6 mm dia fastener Pole Foundation for Octagonal pole from 10 Mtr. To 12 Mtr. | 15 | Each | 8,719 | ₹1,30,785 |
| 7 | Item Code [23.28-2025]:Item Type [Electrical] :: Supply & fabrication steel structure with MS channel / angle / joist / ISMB / sheet etc. including welding, rivetting, cutting, nut & bolt , one coat of primer & two coat of enamel paint etc. as required complete in all respect. . | 600 | Kg | 135 | ₹81,000 |
| 8 | Item Code [4.1/4.1.7-2025]:Item Type [Electrical] :: Supplying and laying FR PVC insulated & unsheathed flexible copper conductor of following nominal sizes with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from copper, stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. | 675 | Mtr | 106 | ₹71,550 |
| 9 | Item Code [6.1-2025.]:Item Type [Electrical] ::Sub Item Code [6.1-2025. + 6.1.1/6.1.1.2]: Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanism , energy limiting of class 3 as per IEC, minimum phase termination capacity of 25 sq.mm., conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating, 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. Single pole MCB (With B / C curve tripping characteristics) /6 A to 32 A rating | 45 | Each | 199 | ₹8,955 |
| 10 | Item Code [Main Panel]:Item Type [Electrical] :: Supply & fixing of switching panel of MS sheet as per enclose drawing with Red Oxide coating with two coats of enamel paint, duly hinged doors operable from both side with locking arrangement mounted on angle iron frame of size 35 mm x 35 mm x 3 mm having 1)Panel Size-3.2mm Sheet(L)-600mm*(H)-1000mm*(D)-350mm Iron Time switch Maxi Rex QTT MDS/L & T double dial (One nos.) 2) Contractor ML4.70 Amp. L & T make three pole (Two nos.) 3) Toggle switch two way (One nos.) 4) MCB Fuse base with link 5 Amp. Hevells make (Three nos.) 5) HRC Fuse base with link 5 Amp. Hevells make (Three nos.) In both. | 15 | Each | 10,000 | ₹1,50,000 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.20 MB
Conditions_08.pdf
Tender Documents • 1.44 MB
BOQ_1020743.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid