Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹38.3 LAccepted-AOC | 1 | Accepted-AOC Being lowest and reasonable | |
| 2 | 2₹42.2 L+₹3.1 L (7.92%)Rejected-Finance PLOT NO 28 SANTOSHIMA COLONY WEST MARREDPALLY SECUNDERABAD 500026 | HYDERABAD | TELANGANA | 500026 | 2 | Rejected-Finance Not being the lowest bidder | |
| 3 | 3₹44.7 L+₹5.6 L (14.4%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | 3 | Rejected-Finance Not being the lowest bidder | |
| 4 | 4₹47.8 L+₹8.7 L (22.2%)Rejected-Finance 7 32 1 PRASANTHI NAGAR GOPALAPATNAM VISAKHAPATNAM 530 027 | VISAKHAPATANAM | ANDHRA PRADESH | 530027 | 4 | Rejected-Finance Not being the lowest bidder | |
| 5 | 5₹48.3 L+₹9.2 L (23.5%)Rejected-Finance | 5 | Rejected-Finance Not being the lowest bidder |
Tender Value
₹47.1 L
EMD Value
₹94,160
Closing Date
2 Oct 2023, 6:00 pmClosed
GE I R AND D RCI, HYDERABAD
GE(I) RND RCI, MILITARY ENGINEER SERVICES, VIGNYANAKANCHA, RCI, HYDERABAD
COMPREHENSIVE MAINTENANCE OF FIRE ALARM PANELS SMOKE AND HEAT DETECTORS MANUAL CALL POINTS AND CONNECTED WORKS AT RCI TECHNICAL AREA CPDC EETF AND ETC. UNDER GE I RND RCI, HYDERABAD
2023_MES_618120_1
8872
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE I R AND D RCI
MES enlisted Class D category c vi and Un enlisted Meeting enlistment criteria of D class in MES and having no recovery pending. For further details ref NIT
8 documents required · 8 mandatory
₹500
Yes
GE I R AND D RCI, HYDERABAD
₹94,160
Yes
17 Jan 2024
11 Sept 2023
4 Oct 2023
11 Sept 2023
2 Oct 2023
25 Sept 2023
Amount
S&F in repairs, weather proof Manual Call Point to match various Conventional Type Fire Alarm system, suitable for surface mounting or semi flush mounting, making necessary connection, testing and making good disturbed surfaces complete all as directed. Make: Apollo, Morley, Agni, Securico
S&F in repairs, weather proof Manual Call Point to match various Addressable Type Fire Alarm system, suitable for surface mounting or semi flush mounting, making necessary connection, testing and making good disturbed surfaces complete all as directed. Make: Apollo, Morley, EST
S&F in repairs, Electric siren single mounting, horizontal, single phase, AC supply, audible diametrical sound range of 1 KM, power 110 V including testing complete all as specified and as directed.
S&F in repairs, electrically operated horizontal double mounting siren, 220/250V, single phase, AC supply, audible diametrical sound range of 2KM including testing complete all as specified and as directed. Make for item No 3&4: Kheraj, Jaykay, Perfect, National
S&F in repairs, photoelectric optical use internal pulsing Smoke Detector addressable type complete all as specified and directed. Make: Kartar, Apollo, Morley, GST 5000
S&F in repairs, Manual Call Point break glass required for Conventional type Fire Alarm System complete all as specified and directed.
S&F in repairs, Response Indicator with set of built in tools for indication of detectors, 6V, fixed on walls or within false ceiling with indication complete all as specified and directed. Make: Dekars, Ravel, Fire, Securico, Agni
S&F in repairs, 24Volts, 8PIN, 24VAC Potential Free Relay with socket in existing Fire Alarm Main Panel complete all as specified and directed.
S&F in repairs, speaker type electrical Hooter, 8"(20CM), 110V single phase complete all as specified and directed. Make: Kheraj, National, Securico or techno commercially equivalent as approved by GE
S&F in repairs, Transformer 24-0-24 Volts, 5Amp in existing Fire Alarm main panel complete all as specified and directed. Make: Manish Engineers or techno commercially equivalent as approved by GE
S&F in repairs, speech auto dialing system suitable for micro controller base, consisting of 13key onboard key pad, 3 message, 1 to 40 numbers storage capacity with provision for fire, special and special help complete all as specified and directed. Make: Securico, Falcon or techno commercially equivalent as approved by GE
S&F in repairs, Assorted fuse 3A, 5A in existing fire alarm panel complete all as specified and directed.
S&F in repairs, 2core 1.5Sqmm FR PVC insulated, PVC round sheathed, flexible copper conductor cable, 1100Volts, ISI marked complete all as specified and directed.
S&F in repairs, 2core 2.5Sqmm FR PVC insulated, PVC round sheathed, flexible copper conductor cable, 1100Volts, ISI marked complete all as specified and directed.
S&F in repairs, 2core 4Sqmm FR PVC insulated, PVC round sheathed, flexible copper conductor cable, 1100Volts, ISI marked including PVC casing & capping with fittings of size 20mm, ISI marked complete all as specified and directed.
Dismantling and Reprogramming Single loop Fire Alarm main panel/ repeater panel board of any make for correct indication of sensors, detectors as per present precise locations as per manufacturer's instructions convenient windows programming software, changing of detector/sensor location, name, address of room, testing for exact fault locations and reconnecting to entire satisfaction of Engineer in Charge complete all as directed.
All as per item No 16 above for Two loop Fire Alarm main panel board
Dismantling and Reprogramming microprocessor based Four loop addressable type Fire Alarm main panel/ repeater panel board of any make for correct indication of sensors, detectors as per present precise locations as per manufacturer's instructions convenient windows programming software, changing of detector/sensor location, name, address of room, testing for exact fault locations and reconnecting to entire satisfaction of Engineer in Charge complete all as specified and directed. Note for item No 16 to 18: Testing shall be done in the presence of Fire Safety Officer, RCI
S&F in repairs, Isolator module used for installation where there is problem of Id connection and damage to devices output 16W/12W, voltage 1500VDC/1MA complete all as specified and directed. Make: Apollo, Morley, XP95
S&F in repairs, Terminal block connector male female 3.81mm connector 2,3,4,5 & 16 in weather proof material complete all as specified and directed.
S&F, in repairs, sealed maintenance free lead acid battery 12Volts 7AH complete all as specified and as directed. Make: EXIDE, AMARON, FURKKAVA
S&F in repairs, single loop main control panel, microprocessor based addressable type fire alarm control panel with LCD display, event storage with real time clock communication for network/repeater one programmable form C relay for fire extensive built in transient protection lamp test facility common fire, supervisory, fault LED indication and battery 12V/7AH including testing complete all as specified and as directed.
S&F in repairs, two loop main control panel, microprocessor based addressable type fire alarm control panel with LCD display, event storage with real time clock communication for network/repeater one programmable form C relay for fire extensive built in transient protection lamp test facility common fire, supervisory, fault LED indication and battery 12V/7AH including testing complete all as specified and as directed. Make for item No 22 & 23: Apollo, Notifier, Tata Honeywell, FDX 5000
S&F in repairs, Four zone main control panel conventional type fire alarm control panel with LCD display, event storage with real time clock communication for network form C relay for fire extensive built in transient protection lamp test facility common fire, supervisory, fault LED indication and battery 12V/7AH including testing complete all as specified and as directed. Make: AGNI, RAVEL, DEKARS, MINIMAX Make of battery for item No 22 to 24: EXIDE, AMARON, FURKKAVA
Opening the Smoke detector and cleaning of its sensor completely with blower including carrying out smoke test with SOLO A10S Detector Tester to verify the detector is live and refixing complete all as directed. Note: Smoke testing with magnet shall not be permitted. Test results shall be submitted duly signed by all concerned.
S&F in repairs, photoelectric optical use internal UV/IR Flame Detector addressable type complete all as specified and directed. Make: Notifier, Siemens, Esser
S&F in repairs, input / output module used for installation where there is problem if ID connection and damage to devices output 16W/12W, voltage 1500DC/1mA complete all as specified and directed. Make: Apollo, Morley, XP95, Notifier
S&F in repairs, Siren Controller set box with ON/OFF switch with LED indication complete all as specified and directed.
S&F in repairs, rewinding Electric Siren single mounted, horizontal, single phase, AC, audible diametrical sound range of 1KM, power 110V including testing complete all as directed.
S&F in repairs, addressable type multi sensor detector with heat and smoke (Photoelectric/Thermal) combination complete all as specified and directed. Make: Apollo, Morley, GST 5000
S&F in repairs, four loop main control panel, microprocessor based addressable type fire alarm control panel with LCD display, event storage with real time clock communication for network/repeater one programmable form C relay for fire extensive built in transient protection lamp test facility common fire, supervisory, fault LED indication and battery 12V/7AH including testing complete all as specified and as directed. Make: Apollo, Notifier, Tata Honeywell, FDX 5000, Morley Note for item No 22 to 24 and 31: Testing shall carried out in the presence of Fire Safety Officer, RCI. Demonstration and training shall be imparted to department personnel.
Dismantling and reprogramming single loop card Fire alarm main panel board of any make for correct indication of sensors, detectors as per present precise locations as per manufacturers instructions convenient window programming software, sensor location, address of room, testing for exact fault location and reconnecting to entire satisfaction of Engineer in charge and as directed.
Dismantling and reprogramming two loop card Fire alarm main panel board of any make for correct indication of sensors, detectors as per present precise locations as per manufacturers instructions convenient window programming software, sensor location, address of room, testing for exact fault location and reconnecting to entire satisfaction of Engineer in charge and as directed.
S&F in repairs, Display card of main fire alarm control panel and repeater panel control panel with LCD display event storage with real time clock communication for network from C relay for fire extensive built in transient protection lamp test facility common fire, supervisory fault LED indication including testing complete all as directed.
S&F in repairs, PCB main card of Main Fire Alarm control panel and repeater panel control panel with loop, event storage with real time clock communication for network from C relay for fire extensive built in transient protection lamp test facility common fire, supervisory fault LED indication including testing complete all as directed
Reprogramming of speech auto dialing suitable for controller base 1 to 40 numbers storage capacity with provision of adding to automatic fire alarm system panel programming phone numbers, recording, cable etc., including testing complete all as directed.
Universal refrigeration and Engineering Company
Shree Ayyappa Engineering
MVV Prasad
S.S.ENGINEERING CORPORATION
ELEVATORS MAINTENANCE ENGINEER WORKS
omsai thermax engineers
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .