SITC OF HIWALL SPLIT AC AT LHO KOLKATA
10030713
GEM/2026/B/8156893
Two Packet Bid
SITC OF 2.0 TR HI-WALL SPLIT SYSTEMS
Kolkata, West Bengal
Total value wise evaluation
BOQ
6 documents required · 6 mandatory
3 yrs
₹60,000
₹10 L
80%
Exempted
Yes
13 Oct 2026
13 Oct 2026
24 Oct 2026
| Item No | Item Title | Description | Qty | Unit | Consignee | Delivery (days) |
|---|---|---|---|---|---|---|
| 1 | SITC OF 1.5 TR HI-WALL SPLIT SYSTEMS | Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete withIndoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr(IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) R-32/R-410/ R-407 Green Refrigerant
wireless Remote control, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotarycompressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply Electrical cable IS 694 or IS 9968 temperature sensing control IS/International Electrotechnical Commission (IEC) 60730,hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS - 1391 Part II 2023. The system shall be able to operate up to 50 Degree C (out door ambient temperature). Inverter Type Cooling with 5 Star BEE Rating, Minimum value of ISEER 5.6. | 2 | SET | Souvagya Kumar Sahoo 700001,LH Okolkata,1 Strand Road, Kolkata | 15 |
| 2 | SITC OF 2.0 TR HI-WALL SPLIT SYSTEMS | Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete withIndoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr(IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) R-32/R-410/ R-407 Green Refrigerant
wireless Remote control, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotarycompressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply Electrical cable IS 694 or IS 9968 temperature sensing control IS/International Electrotechnical Commission (IEC) 60730,hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS - 1391 Part II 2023. The system shall be able to operate up to 50 Degree C (out door ambient temperature). Inverter Type Cooling with 5 Star BEE Rating, Minimum value of ISEER 5.6. | 2 | SET | Souvagya Kumar Sahoo 700001,LH Okolkata,1 Strand Road, Kolkata | 15 |
| 3 | COPPER REFRIGERANT PIPING FOR 1.5TR AND 2.0TR HI-WALL SPLIT AC | Supplying, Installation, testing and commissioning including Power cable ,vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for above system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessoriesas per specifications etc. as required 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm and 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm for 1.5 TR HI WALL SPLIT | 20 | Mtr | Souvagya Kumar Sahoo 700001,LH Okolkata,1 Strand Road, Kolkata | 15 |
| 4 | DRAIN PIPE | Supply and fixing of duly insulated 25mm UPVC drain pipe | 20 | Mtr | Souvagya Kumar Sahoo 700001,LH Okolkata,1 Strand Road, Kolkata | 15 |
| 5 | OUTDOOR STAND FOR 1.5TR AND 2.0TR HI-WALL SPLIT AC | Supplying , Installation, Testing and Commissioning of outdoor frame / stands to withstand the full load of outdoor units and making good all the damage for 1.5 TR Hi-Wall Split AC. | 4 | SET | Souvagya Kumar Sahoo 700001,LH Okolkata,1 Strand Road, Kolkata | 15 |
| 6 | DISMANTLING OF OLD AC SYSTEMS | Dismantling of existing air conditioner | 4 | SET | Souvagya Kumar Sahoo 700001,LH Okolkata,1 Strand Road, Kolkata | 15 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_10030713.pdf
GEM_BID • 0.13 MB
nit_for_ac_work_lho_building_2026-10-13-18-49-14_868b8d6d231447deaee357337bf658e3.pdf
BOQ • 0.61 MB
boq_item_lho_2026-10-13-18-49-14_8cbd5541fe95c74a22bb6dc57a16dc4d.csv
BOQ • 0.00 MB
gtc.pdf
GEM_OTHER • 0.71 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .