Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.7 LAccepted-AOC | L1 | Accepted-AOC REASONABLE | |
| 2 | L2₹8.9 L+₹7,090 (0.81%)Rejected-Finance | L2 | Rejected-Finance HIGH RATE | |
| 3 | L3₹11.2 L+₹2.4 L (27.4%)Rejected-Finance | L3 | Rejected-Finance HIGH RATE | |
| 4 | L4₹11.5 L+₹2.8 L (31.3%)Rejected-Finance HATIA ROAD DANGALPARA DISTT DUMKA JHARKHAND PIN 814101 | DUMKA | DUMKA | JHARKHAND | 814101 | L4 | Rejected-Finance HIGH RATE | |
| 5 | L5₹13.0 L+₹4.2 L (47.7%)Rejected-Finance | L5 | Rejected-Finance HIGH RATE |
Tender Value
₹9 L
EMD Value
₹18,000
Closing Date
17 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AJIT KUMAR DWIVEDI,AE (E/M)
AGE (I) AF SINGARSI
Cleaning of PVC Tank including plumbing fittings and other misc works at AF Stn Singarsi
2022_MES_565575_1
C/8586/E8
Open Tender
Civil Works
Item Rate
180 days
AGE (I) AF SINGARSI
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Yes
AGE (I) AF SINGARSI
₹18,000
Yes
26 Dec 2022
26 Nov 2022
19 Dec 2022
28 Nov 2022
17 Dec 2022
6 Dec 2022
Amount
Taking up or down steel tubing of dia 15mm and connections including cleaning for refixing,complete all as specified and as directed.
Taking up or down steel tubing of dia 20mm and connections including cleaning for refixing,complete all as specified and as directed.
Taking up or down CPVC pipes of 16mm outer dia of SDR 11 and Plain CPVC SDR 11 (including all fittings bend, elbow, union etc) and connections including cleaning for refixing,,complete all as specified and as directed.
Taking up or down CPVC pipes 25mm outer dia of SDR 11 and Plain CPVC SDR 11 (including all fittings bend, elbow, union etc) and connections including cleaning for refixing,complete all as specified and as directed.
Supply and laying of CPVC 16mm outer dia pipes of SDR 11 (including all fittings bend, elbow, union etc) and plain CPVC sdr 11 fittings on walls/ ceilings or laying in floors, completed all as specified and directed.
Supply and laying of CPVC 25mm outer dia pipes of SDR 11 (including all fittings bend, elbow, union etc) and plain CPVC sdr 11 fittings on walls/ ceilings or laying in floors, completed all as specified and directed.
S&F 15mm dia GI tubes (medium grade) with all fitting and fixed complete to walls and ceilings or laid in floors after taking up or down old unserviceable tubing and connections,,complete all as specified and as directed.
S&F 20mm die GI tubes (medium grade) with all fitting and fixed complete to walls and ceilings or laid in floors after taking up or down old unserviceable tubing and connections,,complete all as specified and as directed.
Re-fixing for 15mm dia old steel tubing and connection in new or old position (wall, ceiling, floor etc) including cleaning, re-running the old screw threads as rquired etc complete as obtained from item No 01 above,complete all as specified and as directed.
Re-fixing for 20mm dia old steel tubing and connection in new or old position (wall, ceiling, floor etc) including cleaning, re-running the old screw threads as required etc complete as obtained from item No 02 above,complete all as specified and as directed.
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position including Cleaning and removal of all scales and dirt etc, from tank and from mouth of circulating pipes including float valve complete all as specifed and directed by Engr in charge for the capacity exc 250 ltrs and not exc 500 ltrs,complete all as specified and as directed.
All as per item No 11 above but capacity of tank exceeding 500 litr but n. exc 1000liter.
All as per item No 11 above but capacity of tank exceeding 1000 Ltrs & not exceeding 2000 Ltrs. Note:- For Srl item No 11,12 and 13 above:- (i) If any complaint regarding tank incomming pipe and outgoing pipe, discharge of water, float valve and pressure of water supply to out going pipe, overflow of tank to corresponding bldg received vide users/stn authority or by this office same shall be carried out within 24 hrs. If the contractor failed to carried out the above complaint witin the time mentioned above penality of Rs.500.00 per complaint/day shall be imposed to the contractor and recovery shall be done from the contractor. (ii) only Date of cleaning of tank in DD/MM/YY shall be clearly mentioned and payment shall be made under respective item. (iii) Before cleaning work to be carried out contractor shall check the tank, If any breakage /crack of tank shall found ,contractor shall immediately notify to Engr in charge in written. (iv) Contractor or his agent has to be reported daily at 10.30 am regarding receving the complaint and also to inform about planning of cleaning of tank to be carried out after 48 hrs.
S&F in repair for 500 Ltrs rotational moulded polythene water storage tanks (cylindrical vertical with closed top) of multi-layer, hoisted and fixed in position all as specified in SSR Part-l, after dismantling of old water tank (PVC) and removing to outside defence area.
S&F in repair for 1000 Ltrs rotational moulded polythene water storage tanks (cylindrical vertical with closed top) of multi-layer, hoisted and fixed in position all as specified in SSR Part-l, after dismantling of old water tank (PVC) and removing to outside defence area.
S&F for 500 Ltrs capacity PVC lid / cover for water storage tank including removing of existing broken lid / cover.
M&L for obliterating old writing of any description not exceeding 0.1 Sqm with paint to match existing work as on tank surfaces.
M&L for writing letters or figures (Block, Roman, ltalic or Indian) not exceeding 30 cm height.
S& F in repair 15mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed.
S&F in repair 20mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed.
S&F in repair 25 mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed.
S&F in repair for PTMT ball valves high pressure with epoxy coated aluminium rod & high density plastic ball screwed for 20mm dia pipes all as specified and directed as in repair, (minimum weight 210 gms).
SHARMA ENTERPRISE
M/S ASHA ENTERPRISE
M/S KUMAR AVINASH
DANATION CONSTRUCTIONS
M/S SINGH ENTERPRISE
M/S Subhadip Enterprise
M/S AMARNATH AGARWALLA
M/S New Builders Corporation
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .