Revenue
WORKS
14 conditions · 2 needing a document upload
Financial Eligibility Criteria: The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
Technical Eligibility Criteria: (a) The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i) Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii) One similar work costing not less than the amount equal to 60% of advertised value of the tender. (b) (1) In case of tenders for composite works (e.g. works involving more than one distinct component, such as Civil Engineering works, S&T works, Electrical works, OHE works etc. and in the case of major bridges - substructure, superstructure etc.), tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i) Three similar works each costing not less than the amount equal to 30% of advertised value of each component of tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of each component of tender, or (iii) One similar work each costing not less than the amount equal to 60% of advertised value of each component of tender. Note for b(1): Separate completed works of minimum required values shall also be considered for fulfillment of technical eligibility criteria for different components. (b)(2)In such cases, what constitutes a component in a composite work shall be clearly pre-defined with estimated tender cost of it, as part of the tender documents without any ambiguity.
Defination of Similar Work :- 1. Supply, installation and commissioning of Datalogger or RTUs [OR] 2. Any signal interlocking works involving EI or RRI or PI or IBS or IBH or LC gate or yard modification or UFSBl or Track circuit (AFTC or DC TC) or Axle Counter (SSDAC or MSDAC or HA-SSDAC) or Automatic signalling.
7 conditions · 2 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
TENDER FORM (First Sheet) Annexure-I
ANNEXURE-V
ANNEXURE V-A
Annexure-VIB
Audited Balance Sheets duly certified by the Charted Accountant along with Annexure VI-B
The tenderer shall clearly specify whether the tender is submitted on his own (Proprietary Firm) or on behalf of a Partnership Firm / Company / Joint Venture (JV) / Registered Society / Registered Trust / Hindu Undivided Family (HUF) / Limited Liability Partnership (LLP) etc. The tenderer(s) shall enclose the attested copies of the constitution of their concern, and copy of PAN Card along with their tender. Tender Documents in such cases are to be signed by such persons as may be legally competent to sign them on behalf of the firm, company, association, trust or society, as the case may be.
Tiruchchirappalli Division: Improving LC gate communication reliability by strengthening 6 Quad cables(45 Kms) and Providing RTUs (24 Nos)
T-SG-36-I-40-2024-2025
T-SG-36-I-40-2024-2025
Open
Works - General
12 Months
Chennai, Tamil Nadu
₹0
₹4.7 L
24 Mar 2025
27 Feb 2025
42 items across 1 schedule · ₹2,51,11,060.05 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | Supply of isolation transformer 600:470 ohms as per IRS TC 76-2001 amd 1 or latest | Numbers | 24.00 | 791.12 | 18,986.88 |
| 2 | Supply and Provision o f Earthing a s per RDSO Specification RDSO/SPN/197/2008 or latest (as per Technical Specification enclosed) | Numbers | 24.00 | 28,118.51 | 6,74,844.24 |
| 3 | Supply o f earth electrodes (GI) a s p e r Drg no SG/CN/02/13 | Numbers | 108.00 | 1,618.75 | 1,74,825 |
| 4 | Provision of earth electrodes as per drawing No.SG/CN/02/13 and earthing of metallic sheath and armour of all cables in all apparatus cases, relay room, equipment room, SM's room for block and control, and earthing of all equipments in apparatus cases, power room, relay rack, cable termination rack, control panel, signals, lever frames with MS flat 35mm X 6mm/19c cable (MS flat for closer by areas and MS flat/19c cable combination for farther areas) as per the instructions of Railway representative at site. The work includes painting of earth resistance value on the earth pit. (Supply of 19C cable is not covered in the scope of this schedule). [MS flat for earthing 35mm X 6mm, cement, GI earth electrodes, common salt, charcoal, country bricks, M sand, soldering materials and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers | 108.00 | 1,707.55 | 1,84,415.4 |
| 5 | Supply of I P S t o suit 6 Line R E station as per R D S O Specifications RDSO/SPN/165 or latest (This schedule doe s n o t include Batteries) As per drawing enclosed | Set | 2.00 | 13,07,398.11 | 26,14,796.22 |
| 6 | Commissioning of IPS, this schedule includes arrangement of OEM engineer for checking the Installation and carrying out adjustments of IPS modules and submission o f Pre- commissioning checklist | Set | 2.00 | 59,000 | 1,18,000 |
| 7 | Installation, wiring and testing of IPS as per RDSO Specification No. RDSO /SPN /165 or latest.This w ork includes transporting the IPS from the Stores by loading without any damages and installation of the same at site. This also includes wiring o f all modules, proper earthing of equipments and all other works connected for testing and commissioning of the same. Necessary powdered coated Aluminium ladder arrangements including cable trench, pipes, bolts, and other accessories is included in this schedule.[Earthing is not covered under this schedule] | Set | 2.00 | 77,160.07 | 1,54,320.14 |
| 8 | S u p p l y a n d provision o f n o r m a l j o i n t using T h e r m o s h r i n k jointing k i t ( R D S O s p e c s No TC/77/2012 ( Rev.3) with amendment No.1&2 or latest.& jointing kit to be inspected by RDSO) for 4/6 quad cable normal joint. The work includes excavation of joint p i t o f size 1mX1.5mX1.5m and closing the same after completion o f cable j o i n t a s p e r t h e instruction o f Railway representative at site. | Numbers | 85.00 | 4,628.91 | 3,93,457.35 |
| 9 | S u p p l y a n d p r o v i s i o n o f d e r i v a t i o n joint complete for 6 Quad cables using thermoshrink jointing kit for LC's/stations | Numbers | 44.00 | 4,901.27 | 2,15,655.88 |
| 10 | Supply of RCC cable markers (Supply of RCC cable markers a s p e r drawing No.CSTE/CN/OFC/1. T h e lettering o n the cable marker shall be "SIG" / "TELE" / "OFC" as per the instructions o f Railway representative a t site.) as per drawing enclosed | Numbers | 806.00 | 262.65 | 2,11,695.9 |
| 11 | Excavation of cable trench in all kinds of soil except hard rocky areas including clearing of roots of trees, rocks, bushes etc. to a depth of 1.0 Mtrs and to a width of 0.3 Mtrs. (Laying of cables is not included in this schedule) | Metre | 40300.00 | 64.1 | 25,83,230 |
| 12 | Removing/breaking of existing RCC slabs on the Passenger Platform, trenching to a depth of 0 . 6 m t o accommodate t h e additional cables, replacing the slabs removed after the cables are laid and replastering with cement mortar, refilling the trench by ramming and consolidating i t a s p e r t h e instructions of R ailw a y Representatives a t s i t e . ( L a y i n g of cables is not included in this schedule). | Metre | 500.00 | 314.41 | 1,57,205 |
| 13 | Excavation of trench along route of existing cable duct, opening the slabs to accommodate additional c a b l e laying, REPOSITIONING the slabs removed after the cables are laid and PLASTERING with cement mortar, and refilling the trench by ramming and consolidating it as per the instructions of Railway Representatives at site. (Laying of cables i s not included i n this schedule.)[Cement,M Sand and all other miscellaneous materials required f o r the work shall be supplied by the Contractor]. | Metre | 500.00 | 161.92 | 80,960 |
| 14 | Excavation of trench to a depth of 1 Mtr. for track crossing of cables, refilling of trench by r a m m i n g a n d consolidating i t a s p e r the instructions of Railway representative at site a f t e r l a y i n g o f D W C / R C C p i p e s . During excavation of trench, i t has t o b e ensured that the excavated soil does not mix with the ballast available. The depth of 1m trench shall be from t h e b o t t o m o f sleepers for track crossings. Laying of cables and DWC pipes is not included in this schedule. (Supply of DWC/RCC pipes with couplers/collars is not included in this schedule). | Metre | 500.00 | 385.45 | 1,92,725 |
| 15 | Excavation of trench to a depth of 1 Mtr. for road crossing of cables, laying of DWC/ RCC pipes with collar/ coupling, refilling of trench by ramming and consolidating it and resurfacing it to the original position. Laying of cables is not included in this schedule. (Supply o f DWC/RCC pipes with couplers/collars is not included in this schedule). | Metre | 500.00 | 501.03 | 2,50,515 |
| 16 | Provision of GI pipes (50/100mm dia) for cable laying with offset at both ends and with couplings over RCC bridges, drainage, culverts, and girder bridges. For RCC bridges, drainage, and culverts, the pipes shall be mounted on concrete masonry supports of size 300mm x 300mm x 300mm at an interval of 2 meters. For girder bridges, the pipes shall be fixed on suitable MS clamps at an interval of 2 meters. The ends of the pipes shall be closed with brick masonry abutments to ensure that no cable is exposed. The work shall be carried out as per the instructions of the Railway representative at the site.(Supply of GI pipes with couplings and laying of cables is not included in this schedule).Stone jelly (20/25mm size), bricks, sand, cement, MS angles, flats, bolts, nuts for manufacturing and fixing clamps, bricks, M sand, cement, and other miscellaneous materials for the work shall be supplied by the contractor. | Metre | 1000.00 | 208.54 | 2,08,540 |
| 17 | Fabrication and installation of MS clamps on Girder Bridges f o r t h e support o f G I pipes laid over the girder bridge | Numbers | 250.00 | 570.26 | 1,42,565 |
| 18 | Provision o f G I pipes (50/100mm dia) for cable laying in hard rocky area with off sets at both ends duly supported by concrete blocks of size 300mm x 300 mm x 300 mm at an interval of 2m. The ends of the pipes shall b e closed with brick masonry abutments work so that no cable is exposed, The work shall be carried out as per the instructions of Railway representative at site.(Supply of GI pipes with couplings and laying of cables is not included in this schedule). [Stone jelly of size 20/25mm, bricks, sand, cement, a n d a l l other miscellaneous materials required for the work shall be supplied by the Contractor]. | Metre | 2000.00 | 182.87 | 3,65,740 |
| 19 | Laying o f signaling/power/ telecommunication cables a s p e r c a b l e plan in cable trenches, masonry ducts, RCC Pipes, DWC pipes, GI Pipes etc.(Supply o f cables i s n o t included i n this schedule). | Metre | 56300.00 | 18.18 | 10,23,534 |
| 20 | "Refilling of cable trench 1m depth by 0.3m width throughout, with earth after laying of c a b l e s , a n d consolidating t h e t r e n c h by ramming and levelling." | Metre | 40300.00 | 15.4 | 6,20,620 |
| 21 | "Digging of pit to a depth of 800mm of size 300mmX300mm, casting of concrete foundation of size 300mmX300mmX300mm and Placing of RCC cable markers on top of the foundation and refilling the pit and consolidating it by ramming. T h e cable markers s h a l l b e provided a t an interval of 20 Mtrs. within station limits and 50 Mtrs. outside station limits throughout the cable route, diversions a n d also a t every track/road crossing." | Numbers | 806.00 | 123.35 | 99,420.1 |
| 22 | Excavation o f c a b l e c o i l p i t t o a s i z e of 1.5mx1.5m and depth a s instructed by Railway representative at site, for coiling the cables in rear of relay rooms/ AFTC huts, apparatus cases etc. The work includes coiling the underground cables and placing closely one layer o f country bricks of size approx. 220mm x 100mm x 60mm breadth wise above the cables to cover all the cables in the cable pit, closing and consolidating the pit by ramming and levelling.[Country bricks of size 220mmx100mmx60mm (approximately) shall be supplied by the Contractor]. | cum | 30.00 | 949.05 | 28,471.5 |
| 23 | " R o a d c r o s s i n g / T r a c k C r o s s i n g through Horizontal Drilling at approximately depth of 1.5 t o 2 m below t h e formation level of the earth including insertion of HDPE pipe/DWC pipe along with couplers, drawl of cable (or) direct drawl o f cables etc . (Note: T h e pilot used for HDD should be of sufficient size to suit insertion of HDPE /DWC pipe o f size 120mm (outer dia.) o r direct drawl of three cables (Signalling/Power/Quad/OFC) or three nos.of 40mm dia HDPE pipe or any other combination a s directed b y t h e site engineer) ( Supply of HDPE pipe is not covered in this schedule)" | Metre | 2000.00 | 1,351.45 | 27,02,900 |
| 24 | Fixing o f P B T terminal block/ P B T fuse block, rubber grommets, clamping of cables using t e a k w o o d c a b l e c l a m p s a n d base planks, termination of cables, provision of ND type fuses o f required capacities, provision o f copper bus b a r f o r supply terminals, wiring, provision of termination particulars diagram b o a r d using plywood of thickness 12mm - teakwood finish of size 1800mm x 1 2 0 0 m m w i t h Aluminium grooved channel frame i n t h e relay room. The blank spaces over the top of the cable termination rack shall be covered with phynolic sheet of thickness 3mm wherever required. The termination and cable core particulars shall be painted o n t h e PVC/ nylon sleeves. T h e work a l s o includes identification of cables using aluminium tags provided on each cable with letters punched neatly.(Supply o f P B T terminal blocks 25mm & 60mm centers a n d P B T Fuse blocks is not covered in the schedule) [Wire PVC 3/0.75mm copper, b r a s s bolts and n u t s and washers, f o r fi x i n g PBT terminal/Fuse Block, other fixing bolts and nuts, rubber grommets, PVC/ Nylon sleeves, copper bus bars, teakwood 5 0 m m x 50mm for c a b l e c l a m p s , 25mmx 100mm f o r base planks, phynolic sheet 6mm t h i c k o f size 1200mm x 1800mm with aluminium grooved channel f r a m e , phynolic s h e e t 3 m m thick, paint a n d a l l other miscellaneous materials shall be supplied by the Contractor]. a)Fixing of PBT terminal blocks (25mm/60mm centre) and termination (Per Unit = Per Terminal Block) | Per Unit | 1152.00 | 167.99 | 1,93,524.48 |
| 25 | Fixing o f P B T terminal block/ P B T fuse block, rubber grommets, clamping of cables using t e a k w o o d c a b l e c l a m p s a n d base planks, termination of cables, provision of ND type fuses o f required capacities, provision o f copper bus b a r f o r supply terminals, wiring, provision of termination particulars diagram b o a r d using plywood of thickness 12mm - teakwood finish of size 1800mm x 1 2 0 0 m m w i t h Aluminium grooved channel frame i n t h e relay room. The blank spaces over the top of the cable termination rack shall be covered with phynolic sheet of thickness 3mm wherever required. The termination and cable core particulars shall be painted o n t h e PVC/ nylon sleeves. T h e work a l s o includes identification of cables using aluminium tags provided on each cable with letters punched neatly.(Supply o f P B T terminal blocks 25mm & 60mm centers a n d P B T Fuse blocks is not covered in the schedule) [Wire PVC 3/0.75mm copper, b r a s s bolts and n u t s and washers, f o r fi x i n g PBT terminal/Fuse Block, other fixing bolts and nuts, rubber grommets, PVC/ Nylon sleeves, copper bus bars, teakwood 5 0 m m x 50mm for c a b l e c l a m p s , 25mmx 100mm f o r base planks, phynolic sheet 6mm t h i c k o f size 1200mm x 1800mm with aluminium grooved channel f r a m e , phynolic s h e e t 3 m m thick, paint a n d a l l other miscellaneous materials shall be supplied by the Contractor]. b)Termination using P B T fuse block in cable termination rack (Per Unit = Per Fuse Block) | Per Unit | 120.00 | 201.27 | 24,152.4 |
| 26 | Supply of Handheld True RMS Multi Meter, as per Technical specification | Numbers | 10.00 | 23,192.34 | 2,31,923.4 |
| 27 | Supply of Digital Insulation tester (Megger) 50V- 500V/1000 mega ohm battery operated with all c o m p l e t e a c c e s s o r i e s , a s per Technical specification | Numbers | 10.00 | 11,844.52 | 1,18,445.2 |
| 28 | Supply o f Cable Route Tracer a s per Technical specification | Numbers | 12.00 | 5,78,788.99 | 69,45,467.88 |
| 29 | Supply o f digital Cross Talk Measurring set as per spec.no.IRS.TC.45/88 with latest amd, as per Technical specification | Numbers | 10.00 | 70,308 | 7,03,080 |
| 30 | Supply of Transmission measuring set (TMS) with accessories as per IRS Spec No. IRS:TC 43- 87 or latest, as per Technical specification | Numbers | 10.00 | 57,699.4 | 5,76,994 |
| 31 | S u p p l y o f D o u b l e w a l l e d corrugated p i p e - 1 0 3 . 5 m m i n n e r d i a & 1 2 0 m m o u t e r dia conforming to specification No. IS 14930(Part 2): 2001 with one coupler for every 6 m o f pipe as per Technical specification | Metre | 1000.00 | 365.19 | 3,65,190 |
| 32 | Supply of GI pipes - 50mm dia -3.65mm thick as per Technical specification | Metre | 3250.00 | 457.88 | 14,88,110 |
| 33 | Supply o f HDPE Pipe 40mm (outer dia)/33 mm (inner dia) with couplers | Metre | 2000.00 | 60.93 | 1,21,860 |
| 34 | Supply o f P B T terminals 25mm/ 60mm centre and PBT Fuse blocks with necessary inspection a s p e r specification/ drawing/ description enclosed in this document. a)Supply of PBT terminals 25mm centre. | Numbers | 2400.00 | 61.44 | 1,47,456 |
| 35 | Supply o f P B T terminals 25mm/ 60mm centre and PBT Fuse blocks with necessary inspection a s p e r specification/ drawing/ description enclosed in this document. c)Supply of PBT fuse block without ND fuse | Numbers | 240.00 | 103.84 | 24,921.6 |
| 36 | "Excavation o f pit, casting concrete foundation and erection of apparatus case half size as per Drg, No.SG/CN/02/7, fixing one 'E' type lock for the front door and latching arrangement for the back door, and fixing o f o n e hardwood shelf plank 37mm thick and painting the apparatus case inside and outside with one coat of red- oxide and two coats of aluminium paints. (Supply of apparatus case is not included in this schedule).[Foundation bolts and nuts, cement, 'E' type locks, M sand, stone jelly of size 20/25mm,37mm hard wood planks, latching ""arrangements, paints, varnish, fixing bolts & n u t s a n d a l l o t h e r miscellaneous materials required for the work shall b e supplied by the Contractor]""" | Numbers | 65.00 | 8,787.04 | 5,71,157.6 |
| 37 | Termination o f n e w main/tail c a b l e s o n the existing terminals/ fuse blocks in apparatus c a s e s / b a t t e r y b o x e s / C T b o x e s / cable termination r a c k s a s p e r a p p r o v e d circuit diagram. T h e terminal particulars a r e to be repainted /corrected o n the doors of apparatus cases/ battery boxes/ cable termination boxes and FTOT index board as instructed by Railway representative at site. This w o r k includes closing t h e opening created f o r entry o f new cables i n the apparatus cases w i t h masonry b r i c k work and sealing t h e b o t t o m o f the apparatus cases/ cable termination racks with cable compound.[Paints, wire PVC 3/0.75mm and 16/0.2mm copper, s e a l i n g compound, bricks, cement, M sand and all other required miscellaneous materials shall be supplied by the contractor].(Per Unit = Per Terminal block) | Per Unit | 500.00 | 73.59 | 36,795 |
| 38 | Termination o f main, tail, Signaling and power cables a n d internal wiring on terminal/ fuse b l o c k s i n n e w apparatus cases, cable termination boxes and in gate Lodges excluding cable termination rack at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood base p l a n k , fi x i n g of Phynolic synthetic industrial fibre base fine weave cotton fibre board 6mm thick for terminal board to suit each apparatus case, v a r n i s h i n g all teakwood i t e m s , fi x i n g of terminals/ fuse blocks o n t h e terminal board, d r i l l i n g of necessary h o l e s , termination of cables, wiring, identification o f c a b l e s using aluminium tags with letters punched neatly, as p e r approved circuit diagram a n d cable plan, painting of particulars on sleeves andalso on the inner side of the doors of apparatus cases. After terminations are "over, t h e s i d e openings of apparatus case foundation shall b e closed with brick work, cement plastered, the inter-space filled with M sand u p t o b a s e level a n d the bottom surface s h a l l b e sealed w i t h sealing compound.(Supply of PBT terminals and Fuse blocks is not c o v e r e d i n t h i s schedule)." a)Termination on 25/60mm PBT terminals (new location)(Phynolic sheet)(Per Unit = Per Terminal block) | Per Unit | 1152.00 | 172.14 | 1,98,305.28 |
| 39 | Termination o f main, tail, Signaling and power cables a n d internal wiring on terminal/ fuse b l o c k s i n n e w apparatus cases, cable termination boxes and in gate Lodges excluding cable termination rack at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood base p l a n k , fi x i n g of Phynolic synthetic industrial fibre base fine weave cotton fibre board 6mm thick for terminal board to suit each apparatus case, v a r n i s h i n g all teakwood i t e m s , fi x i n g of terminals/ fuse blocks o n t h e terminal board, d r i l l i n g of necessary h o l e s , termination of cables, wiring, identification o f c a b l e s using aluminium tags with letters punched neatly, as p e r approved circuit diagram a n d cable plan, painting of particulars on sleeves andalso on the inner side of the doors of apparatus cases. After terminations are "over, t h e s i d e openings of apparatus case foundation shall b e closed with brick work, cement plastered, the inter-space filled with M sand u p t o b a s e level a n d the bottom surface s h a l l b e sealed w i t h sealing compound.(Supply of PBT terminals and Fuse blocks is not c o v e r e d i n t h i s schedule)." b)Termination on PBT fuse block (new location) (Phynolic sheet)(Per Unit = Per Fuse block) | Per Unit | 120.00 | 209.93 | 25,191.6 |
| 40 | Termination o f main, tail, Signaling and power cables a n d internal wiring b y fixing additional terminals/ fuse blocks o n the existing terminal boards of apparatus cases, cable termination boxes etc. T h e work includes fixing of all new cables by teakwood clamp o n teakwood base plank, varnishing all teakwood items, fixing of terminals/ fuse blocks, on the existing terminal boards, drilling o f necessary holes, termination of cables, wiring, identification o f cables using aluminium tags with letters punched neatly, as p e r approved circuit diagram a n d cable plan, painting o f particulars o n sleeves and also on the inner side o f the doors of apparatus cases. After terminations are over, the side openings of apparatus case foundation shall b e closed with brick work, cement plastered, the inter-space filled with M sand u p t o b a s e level a n d the bottom surface s h a l l b e sealed w i t h sealing compound. a)Termination of cables on 25/60mm PBT terminals (existing location)(Per Unit = Per Terminal block) | Per Unit | 500.00 | 151.09 | 75,545 |
| 41 | Termination o f main, tail, Signaling and power cables a n d internal wiring b y fixing additional terminals/ fuse blocks o n the existing terminal boards of apparatus cases, cable termination boxes etc. T h e work includes fixing of all new cables by teakwood clamp o n teakwood base plank, varnishing all teakwood items, fixing of terminals/ fuse blocks, on the existing terminal boards, drilling o f necessary holes, termination of cables, wiring, identification o f cables using aluminium tags with letters punched neatly, as p e r approved circuit diagram a n d cable plan, painting o f particulars o n sleeves and also on the inner side o f the doors of apparatus cases. After terminations are over, the side openings of apparatus case foundation shall b e closed with brick work, cement plastered, the inter-space filled with M sand u p t o b a s e level a n d the bottom surface s h a l l b e sealed w i t h sealing compound. b)Termination of cables on PBT fuse block (existing location)(Per Unit = Per Fuse block) | Per Unit | 50.00 | 188.86 | 9,443 |
| 42 | Engaging mechanical excavators like JCB or other machineries for regarding and levelling t h e f o r m a t i o n , dismantling a n y infringing structures, clearing a n d removing debris etc., with all leads and lifts etc., complete and as per the instruction of Railway representative at site. | Hour | 30.00 | 1,202.5 | 36,075 |
| Schedule total | ₹2,51,11,060.05 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
LetterofCreditRBLr_1.pdf
ATTACHMENT
ProcedureforundertakingdiggingworkinvicinityofSignalingElectricalandTelecomcables.pdf
ATTACHMENT
4_JPODigging12-06-23.pdf
ATTACHMENT
40_RTUTD-27-02-2025.pdf
ATTACHMENT
4041NITCPROSIGNED.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .