Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.8 CrAccepted-AOC | ₹1.8 Cr | 1 | Accepted-AOC Accept |
| 2 | 2₹1.9 Cr+₹12.2 L (6.96%)Rejected-Finance VILLA NO F 1 PARADISE ON EARTH PDA COLONY OPP MALL DE GNA PORVORIM GOA INDIA | ₹1.9 Cr+₹12.2 L (6.96%) | 2 | Rejected-Finance Reject |
Tender Value
₹1.7 Cr
EMD Value
₹3.4 L
Closing Date
1 Apr 2024, 3:00 pmClosed
Executive Engineer(E), PC,GTDC
Paryatan Bhavan Patto panaji
Illumination of Touristic Places at Kirlapal Junction Wagon and Kalsai and Installation of 4 arm poles in Sanvordem Constituency
2024_GTDCL_15281_1
GTDC/PC/EE(E)/2023-24/e-86
Open Tender
Electrical Works
Item Rate
180 days
Paryatan Bhavan Panjim
Please refer Tender documents.
6 documents required · 6 mandatory
₹8,000
₹3.4 L
19 Jul 2024
15 Mar 2024
2 Apr 2024
15 Mar 2024
1 Apr 2024
15 Mar 2024
Amount
Supply Installation, testing and commissioning of 9 m high hot dipped galvanised conical poles with mm. Dia ‘B’ class G.I. Pipe, 1.2m. in length along with pole cap of 300mm length and 80 mm dia.(Suitable to pole top) duly welded having bottom dia. from 155 to 170 mm, top dia.from 65 to 75 mm Make Bajaj, Transail, RR Ispat as required and directed by engineer incharge.
Supply and Installation of 1000mm single arm bracket PU painted.Make Valmount, Bajaj, Transail, RR Ispat as required and directed by engineer incharge.
Supply and Installation of 1000mm four arm bracket PU painted.Make Valmount, Bajaj, Transail, RR Ispat as required and directed by engineer incharge.
Supply of M24 x 750 MM " J " Type foundation bolts. Make:-RR ISPAT /CONSOUL
Supply, Installation, Testing and Commissioning of 120W LED lights. All specification mention in Gurantee Technical Parameters (GTP) as referred by GED
Supply of 100 A Kit Kat Fuse - 3Nos, Fuse box - 1 no, 1.5 '' GI pipe - 1 No, Cable Gland- 2 nos., 35 size AG Lug pipe-4 nos , 35 size Ring type lug -4 nos 'Erection, Glanding, Termination & Commissioning of 100 AMPS Kitkat Fuse box with Fuse on GED RCC Pole for Tapping and laying of GI Pipe
Supplying and fixing 6 A to 32 A, C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required. '(a) SP, Cat A
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means in foundation pipeline trenches drain (not exceeding 1.5 m in width or 10 sq.m. on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directedwithin a lead of 50m.(a)All kinds of soil
Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete.
Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 40 m nominal size) excluding cost of centering, shuttering and finishing. (a) All works upto plinth level
Centering & shuttering including Strutting, Propping & removal of forms for : (i) Foundations, Footings, Bases for columns
Providing TMT steel reinforcement bars of (SAIL, TATA. VIZAG, JSW Steel Ltd.) ) (Confirming to IS 1786 of 1986) for RCC work (conforming to I.S. 1786 of 1986) including bending, binding & placing in position in all the floors along with the factory made precast concrete cover blocks of specified sizes whose compressive strength is not less than that of surrounding concrete in the structural member.
Providing and laying in position ready mixed concrete (RMC) High Performance Concrete per MORTH clause 1715 manufactured in fully automatic batching plant and transported to site of work in transit mixer for a lead upto 10kms having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C., from the transit mixer to the site of laying, excluding the cost of centering, shuttering, finishing and reinforcement including the cost of admixtures in recommended porportions as per IS : 9103 to accelerate/retard setting of concrete, improve workability without imparing strength and durability as per the directions of the engineer-in-charge. All works upto floor V level .M-20 grade of concrete
Providing at store or site work non - pressure RCC pipes of with collar joints conforming to IS:458-2003 revised as per amendment No. 11, including freight, carting, loading, unloading, stacking etc. complete. (b) 100mm
Conveying carefully from stack at site, 250m from both sides rolling and lowering into trenches, laying and jointing true to line and level, RCC spun pressure and non- pressure pipes of various classes, specials including collar and perfect linking of joint with jack to correct position including cost of joining material in cement mortar 1:2, necessary hydraulic testing, curingof cement mortar etc. complete. (a) 100mm
Cutting the bituminous road for laying the pipelinein trenches for a width of 0.6m including labour,tools, etc. and disposing the excavated excessmaterial from the trench to a distance of 1000metres, including making level the trench surface by utilising the serviceable material to the level ofthe top surface of road, by compacting, wateringramming with rolling with road roller aftercompletion of laying of pipe and refilling thetrenches etc. complete as per the direction of engineer in charge. By Manual Means :ii) District Road, State highway, National highway and roads of similar standards
Repairs and reinstatement to the road for trenchesmade by laying water supply pipeline, byremoving the refilled material in the trench for thetotal depth of 0.42m and making good the roadsurface by providing laying rollling by road rollercompacting for laterite soling 30cm thick, twolayer of full grout of 50mm thick each, tack coatand open graded premix carpet of 20mm thicknessas per specifications mentioned in item nos 14086,14093, 14051 & 14068 of road GSR respectively,complete as per the direction of the engineer incharge. (a) District Road, State highway, National highway and roads of similar standards
Supply of 3 core unarmoured PVC/XLPE insulated, PVC sheathed copper conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size. ' 3 Core 2.5 sq.mm
Supply of 4 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size. ' 4 Core 16 sq.mm
Supply of 3 1/2 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size .3 1/2 Core 35 sq.mm
Supply of 3 1/2 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size .3 1/2 Core 70 sq.mm
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm direct in ground including excavation in the form of a trench as per Cable Trench Drawing provided by the Engineer-Incharge,sand cushioning with screened sand bed of 20mm thick , protective covering with bricks placed breadth-wise on top of cable all over the run( the brick protection shall cover the cable and project atleast 5 cms over the sides of the cable) and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required.'(b) In rocky strata
Supply and Laying of PVC wire 2C X 2.5Sq.mm 1.1KV grade for service connection
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size exceeding 25 sq.mm but not exceeding 120 sq.mm direct in ground including excavation in the form of a trench as per Cable Trench Drawing provided by the Engineer-Incharge,sand cushioning with screened sand bed of 20mm thick , protective covering with bricks placed breadth-wise on top of cable all over the run( the brick protection shall cover the cable and project atleast 5 cms over the sides of the cable) and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required. (b) In rocky strata
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm in the existing RCC/HUME/STONEWARE Metal pipe, etc. complete as required
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size exceeding 25 sq.mm but not exceeding 400 sq.mm in the existing RCC/HUME/STONEWARE Metal pipe, etc. complete as required.
Supplying and making cable end terminations with brass compression gland and aluminium lugs for folowing sizes of 4 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required.4 x 16 Sq. mm.
Supplying and making cable end terminations with brass compression gland and aluminium lugs for folowing sizes of 3 1/2 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. 3 1/2 x 35 Sq. mm.
Supplying and making cable end terminations with brass compression gland and aluminium lugs for folowing sizes of 3 1/2 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. 3 1/2 x 70 Sq. mm.
Supplying and making cable end terminations with brass compression gland and copper lugs for folowing sizes of 3 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. ' 3 x 1.5/2.5 Sq. mm.
Street Light Service Pillar made out of CRCA sheet with PU painted complete with TPN incoming andoutgoing MCCBs, TP Contactors, Electonic/Digital/ mechanical Timer, connectors etc. complete (Street light Pillar)
Supply, installation, testing and commissioning of electronic type three phase energy meter (KWh), 4 wire, ISI marked, in polycarbonate or sgheet steel body ( base mounting type) with counter display/LCD display, with ELT, in Class 1.0, 50 Hz, 240 V. AC duly tested by MRT along with Test Certificates, complete as required of following capacity of make L & T only. (a) 5 to 20 A
Earthing with GI earth pipe 2 mts long 40 mm dia medium class with ISI mark,of approved brands, including accessories and providing masonry enclosure with CI/RCC cover having locking /lifting arrangement and watering pipe etc. with charcoal or coke and salt) as required as per the Earthing Drawing provided by the Engineer Incharge.The scope of work includes the following: a) Excavation of pit of size 1.0x1.0x 2.0 mtrs(min) and disposal of excavated soil. b) Class B GI pipe, 40mm diameter as per specifications. c) Charcoal/salt as per specs ( paid seperately). d) Refilling the pit of size 1.0x1.0x 2.0 mtrs(min) with soft black soil of minimum resistivity i/c transportation. e)Masonary chamber with proper foundation, cover plate and locking arrangement. f) Testing of earth value with earth megger and certifications of its value. Aluminium tag with embossed earthing value to be attached to the pipe. g)watering arrangement(plumbing will be paid seperately) '(b) In rocky strata
Supplying and laying 25 mm x 6 mm GI strip at 0.5 m below ground as strip earth electrode including soldering etc. as required.
Supplying and laying 6 SWG GI wire at 0.5 m below ground level for conductor earth electrode including soldering etc. as required.
Supply of manbucket Crane with 3 Nos. Man power for tree trimming.
Shivam Combines
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .