| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.3 LAccepted-AOC NEAR PUMP HOUSE ROAD NEAR RED ROSE SCHOOL BABINA CANTT JHANSI DISTT UP 284401 | JHANSI | UTTAR PRADESH | 284001 | L1 | Accepted-AOC Being a L1 bidder | |
| 2 | L2₹21.7 L+₹4.6 L (27.1%)Rejected-Finance | L2 | Rejected-Finance Not being a
lowest
tenderer | |
| 3 | L3₹22.9 L+₹5.8 L (33.8%)Rejected-Finance 1308 MAIN ROAD BABINACANTT DIST JHANSI 284 401 | BABINA | JHANSI | UTTAR PRADESH | 284401 | L3 | Rejected-Finance Not being a
lowest
tenderer | |
| 4 | L4₹23.2 L+₹6.1 L (36.0%)Rejected-Finance 640 MAIN ROAD BABINA CANTT JHANSI UP 284401 | BABINA | JHANSI | UTTAR PRADESH | 284401 | L4 | Rejected-Finance Not being a
lowest
tenderer | |
| 5 | L5₹24.7 L+₹7.7 L (44.8%)Rejected-Finance UGLING ROAD OPP FIRE BRIDGE OFFICE LEH 194101 | LEH | LEH | LADAKH | 194101 | L5 | Rejected-Finance Not being a
lowest
tenderer |
Tender Value
₹33 L
EMD Value
₹66,000
Closing Date
29 Jun 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE BABINA
GE BABINA CANTT 284401
CERTAIN SPECIAL REPAIR WORKS IN MISC OTM AND MD ACCN IN AGE EM UNDER GE BABINA
2020_MES_344925_1
GE/BAB/TOKEN /11 OF 2020-2021
Open Tender
Electrical and Maintenance Works
Item Rate
184 days
GE BABINA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE BABINA
₹66,000
Yes
16 Sept 2020
15 May 2020
1 Jul 2020
15 May 2020
29 Jun 2020
30 May 2020
60 days
Amount
Taking down carefully aluminium/copper point wiring on batten or in PVC /MS conduit (Open/concealed) with earth wire etc (for light, fan, socket or power point ) complete,including fixture and fitting such as switches,ceiling roses,pendents,regulators,sockets,light fitting etc.removing from site as per conditions and making good the disturbed surfaces of walls, Floors, ceilings etc and as directed.
Taking down carefully existing wooden board , Main switch, MCB DB boxes with MCBs, sheet metal boxes, cut out, etc of any size , any capacity from boards etc complete and as directed.
Taking down carefully sub main wiring / service connection twin core from wall / LT pole , of any size of Aluminum/ Copper conductor with wooden batten and or through rigid conduit ( any type ) including GI wire and making good the disturbed surfaces of walls, roofs, floors etc complete and as directed.
M & L for surface conduit point wiring for One light point controlled by one switch complete with PVC insulated and unsheathed flame retardant low smoke ( FRLS ) cable of 1.5 sqmm (nominal area) with stranded copper conductor single core 1100 volts grade in and including rigid PVC conduit not less than 19 mm dia, clip, with MS terminal boxes (not less than 1.6 mm thick) and painted with one coat of red oxide primer all around and two coats of black bituminous paint from out side and two coat of aluminum paint from in side including common earth dolly with 3mm thick ISI marked hylam sheet/ backlite sheet cover of approved make and colour including 1.5 sqmm green stranded copper conductor as continuous earth wire with lugs complete including cutting necessary chases on wall / ceiling surfaces for drawing of conduit & cables as required and making good disturbed surfaces of walls with CM 1:3 and matching with the existing surfaces including colour washing all as specified and as directed.
All as per item No. 4 above but one fan point controlled by one switch & regulator and ditto-.
All as per item No. 4 above but One 3/5 pin 5 Amp socket outlet point controlled by one switch on independent board and ditto.
All as per item No. 4 above but One 3/5 pin 5 Amp socket outlet point controlled by one switch on same board and ditto.
All as per item No. 4 above but above but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed flame retardant low smoke ( FRLS ) cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with 2.5 sqmm green stranded copper conductor as continuous earth wire with lugs complete all as specified and as directed.
M & L for casing and caping point wiring for One light point controlled by one switch complete with PVC insulated and unsheathed flame retardant low smoke ( FRLS ) cable of 1.5 sqmm (nominal area) with stranded copper conductor single core 1100 volts grade in and including rigid PVC conduit not less than 19 mm dia, clip, with MS terminal boxes (not less than 1.6 mm thick) and painted with one coat of red oxide primer all around and two coats of black bituminous paint from out side and two coat of aluminum paint from in side including common earth dolly with 3mm thick ISI marked hylam sheet/ backlite sheet cover of approved make and colour including 1.5 sqmm green stranded copper conductor as continuous earth wire with lugs complete including cutting necessary chases on wall / ceiling surfaces for drawing of conduit & cables as required and making good disturbed surfaces of walls with CM 1:3 and matching with the existing surfaces including colour washing all as specified and as directed.
All as per item No. 9 One 3/5 pin 5 Amp socket outlet point controlled by one switch on independent board and ditto.
All as per item No. 9 One 3/5 pin 5 Amp socket outlet point controlled by one switch on same board and ditto.
All as per item No. 9 above but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed flame retardant low smoke( FRLS ) cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with 1.5 sqmm green stranded copper conductor as continuous earth wire with lugs complete all as specified and as directed.
M & L for concealed point wiring for One light point controlled by one switch complete with PVC insulated and unsheathed flame retardant low smoke ( FRLS ) cable of 1.5 sqmm (nominal area) with stranded copper conductor single core 1100 volts grade in and including rigid PVC conduit not less than 19 mm dia, clip, with MS terminal boxes (not less than 1.60 mm thick) and painted with one coat of red oxide primer all around and two coats of black bituminous paint from out side and two coat of aluminum paint from in side including common earth dolly with 3mm thick ISI marked hylam sheet/ backlite sheet cover of approved make and colour including 1.5 sqmm green stranded copper conductor as continuous earth wire with lugs complete including cutting necessary chases on wall / ceiling surfaces for drawing of conduit & cables as required and making good disturbed surfaces of walls with CM 1:3 and matching with the existing surfaces including colour washing all as specified and as directed .
All as per item No. 13 but one fan point controlled by one switch & regulator and ditto.
All as per item No. 13 but One 3/5 pin 5 Amp socket outlet point controlled by one switch on independent board and ditto.
All as per item No. 13 but One 3/5 pin 5 Amp socket outlet point controlled by one switch on same board and ditto.
All as per item No. 13 but above but one bell/buzzer point controlled by one switch and ditto
All as per item No. 13 above but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed flame retardant low smoke ( FRLS ) cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with 2.5 sqmm green stranded copper conductor as continuous earth wire with lugs complete all as specified and as directed.
S&F control switch piano flush button type 5 Amp single pole one way ,230 volts ,50 Hz, complete all as specified and as directed.
S&F socket outlet 2 in1, 3 pin, 5 Amp flush type complete all as specified and as directed.
S&F control switch piano flush button type 15 Amp, single pole ,one way , 230 volts ,50 Hz , complete all as specified and as directed.
S&F socket outlet 2 in1, 3 pin, 5 Amp and 15 Amp flush type complete all as specified and as directed.
S&F control switch bell push button type , 5 Amp ,single pole, 230 Volts , 50 Hz , complete all as specified and as directed.
S & F Lamp holder,PVC/Urea type with back plate suitable for batten fittings complete all as specified as directed
S&F ceiling rose,surface bakelite 63 x50mm three brass terminal, AC 230 Volts, 50 Hz , ISI marked” complete all as specified and as directed.
S&F delux Fan regulator, electronic rotary with steps ISI marked 230 Volt , 50 Hz complete all as specified and as directed.
S&F in replacement control switch piano flush button type 5 Amp single pole one way ,230 volts ,50 Hz, complete all as specified and as directed.
S&F in replacement socket outlet 2 in1, 3 pin, 5 Amp flush type complete all as specified and as directed.
S&F in replacement control switch piano flush button type 15 Amp, single pole ,one way , 230 volts ,50 Hz , complete all as specified and as directed.
S&F in replacement socket outlet 2 in1, 3 pin, 5 Amp and 15 Amp flush type complete all as specified and as directed.
S & F in replacement Lamp holder,PVC/Urea type with back plate suitable for batten fittings complete all as specified as directed
S&F in replacement delux Fan regulator, electronic rotary with steps ISI marked 230 Volt , 50 Hz complete all as specified and as directed.
S&F in replacement ceiling rose,surface bakelite 63 x50mm three brass terminal, AC 230 Volts, 50 Hz , ISI marked” complete all as specified and as directed.
S&F Bell Ding Dong AC 230 Volt 50 Hz single pole complete all as specified and as directed.
S & F 7W LED retrofit lamp B-22 “holder base B-22, bipin type AC 230 Volts, 50 Hz with PF not less than 0.95 with polycorbonate body and aluminium heat sink complete all as specified as directed. Make C&S Cat No LTHPLEDLAMP7W/B22 or equivalent of Havells/Bajaj/ Halonix
M&L for Sub main wiring with PVC insulated, unsheathed Flame retardent(FR) 2 single core cable 1100 volts grade with copper conductor of size 6.0 sq mm (Nominal area) multi stranded drawn into conduit (Existing / new) with and including 2.5 sqmm green stranded copper conductor as contineous earthwire with lugs complete all as specified and as directed. Note: New conduit and conduit accossories shall be measured separately.
M&L for Sub main wiring with PVC insulated, unsheathed Flame retardent(FR) 2 single core cable 1100 volts grade with copper conductor of size 10 sq mm (Nominal area) multi stranded drawn into conduit (Existing / new) with and including 6 sqmm green stranded copper conductor as contineous earthwire with lugs complete all as specified and as directed. Note: New conduit and conduit accossories shall be measured separately.
M&L for Sub main wiring with PVC insulated, unsheathed Flame retardent(FR) 2 single core cable 1100 volts grade with copper conductor of size 10 sq mm (Nominal area) multi stranded drawn into conduit (Existing / new) with and including 10 sqmm green stranded copper conductor as contineous earthwire with lugs complete all as specified and as directed. Note: New conduit and conduit accossories shall be measured separately.
S & F Regid non-metallic PVC conduit not less than 32 dia (external) ISI marked (on surface) incl of all accessories and all fittings such as Tees,bends, elbows, reducers, bell mouth, tube ends and fixing accossories such as couplers,lock nuts, saddles, pipe hook etc complete all as specified and as directed.
S&F in replacement Sheet metal enclosure TPN DBs with 160 Amp MCCBs as incomer SP/TP as out going for Lexic MCB of suiatble repture capature as out going , 4 way with safe shroud for Netural links,Compact Bus bar assembly with IP-43 IK-09 protection double door complete with appropriate size of bus bar and neutral link, fixed flush in wall including cutting chessis/ slot in wall for fixing DB and making good disturbed wall surfaces to match with existing specification . Note : MCCB and MCBs shall be measured and paid seperately . Make:- C&S Cat part No. CSDBMCCB100DD12IP43 OR EQUIVALENT IN HAVELLS/HPL/LEGRAND/ABB /L&T /Standard
S&F in replacement MCCB 160 Amps,415 Volts, 4 P , 50HZ , having 25 KA rupturing capacity with electronic trip arrangment and setting screw upto 70% including making connection with excisting cable with connection and materials like copper strips,lugs,nut & bolts etc. complete all as specified and as directed.
S&F in replacement sheet metal enclosure double door concealed suitable for distribution boards when MCBs to be used having 100 Amp rated bus bar 8 ways 240 V complete all as specified and as directed .
S&F in replacement sheet metal enclosure double door concealed suitable for distribution boards when MCBs to be used having 100 Amp rated bus bar 4 ways 240 V complete all as specified and as directed .
S&F in replacement MCB single pole and neutral 63 Amp 240 V ,10KA , 'C' series, with copper lugs complete all as specified and as directed
S&F in replacement MCB single pole and neutral 40 Amp 240 V ,10KA , 'C' series, with copper lugs complete all as specified and as directed
S&F in replacement MCB single pole 6 to 32Amps 240 V,10KA, 'C' series, with copper lugs complete all as specified and as directed .
S & F in replacement 20 W LED 6000 K (4') Decorative ultra slim linear LED lighting fixture with extruded Al. heat sink, environmental friendly, energy efficent interated driver fitted and including wiring upto and terminal into existing ceiling rose complete all as specified and directed . Make: Havells cat part No LHEXBHP7PN1W020 ( LINEAR DLX ) or equivelent in Philips/Bajaj /CG.
S&F in replacement light fitting 1 x10 Watt bulkhead luminaries with LED bulb 10 Watts, complete with all accessories and including connecting up with three core twisted flexible copper conductor cable with suitable size of 230 Volts, 50 Hz complete all as specified and directed Make : Bajaj Cat part no BIBWP 10 W LED or Equivalent in Philips/Havells/Wipro/Crompton
S &F in replacement VIVA LED mini LED battan ( 4' ) , 20 W fitting , anodised extruded aluminium housing , high transmissitivity diffuser and high lumen output etc complete and including wiring upto and terminal into existing ceiling rose etc complete and as directed . Make :- Bajaj cat Part No.BCLAB 20W or Equivalent in Philips/Havells/Wipro/Crompton
S&F in replacement 10 W BATTEN LED Integrated LED channel , decorative ultra slim linear fixture with engineering plastic batten with white acrylic cover and with integrated electronic driver and 10 LED lamp fitted including wiring upto and terminating into existing ceiling rose etc complete and as directed. Make:- Bajaj cat Part No.BCLSB 10NW or Equivalent in Philips/Havells/Wipro/Crompton
S & F in replacement 15 Watt ,Decorative wall light fixture made up of polycarbonate suitable for 15W retrofit CFL (Spiral B-22 base including 15 Watt CFL etc complete . Make:- Havells Cat No : LHDL06160099 ( CITY 3 ) or equivalent in Philips/Bajaj/Wipro/Crompton
S&F in replacement , connecting and testing LED street light fitting 1 X30 W LED with pressure die cast aluminium with individual LEDs as light source and lens embedded PC cover having top opening seperate driver compartment with IP 66 protection and impact resistance of IK 07 etc complete and including providing bracket made of 32 mm dia , light grade tubing 1.80 mtr long , made to shape and incl providing two nos clamp of suitable shape & size made of 50mm x 6 mm with nuts, bolts & washers etc including electric connection with 1.5 sqmm two single core PVC insulated and PVC sheathed cable stranded Copper conductor upto source , fixed on walls/pole complete and as directed. Bajaj Cat No. BRLEP30WLEDWH ( Edge Plus LED) or Equivalent in Philips/Havells/Wipro
S &F in replacement , connecting and testing street light fitting 1x45 W LED with pressure die cast housing with toughned glass and individual LEDs with secondary optics and IP 66 protection with high power LEDs as light source and electronic driver and including including providing bracket made of 32 mm dia , light grade tubing 1.80 mtr long , made to shape and incl providing two nos clamp of suitable shape & size made of 50mm x 6 mm with nuts, bolts & washers etc including connection with 1.5 sqmm two single core PVC insulated and PVC sheathed cable stranded Copper conductor upto existing source and fixed on walls/pole complete as specified and as directed. Make:- Bajaj -BRTFG 45W LED I (WHITE) or or Equivalent in Philips/Havells /Wipro
S& F in replacement Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 32 Amp C Series
Taking down and Refixing of old celing fans alongwith providing new electric fan regulator complete and after painting ,greasing and marking of MES no all as specified as directed.
Taking down ceiling fan for minor repairing work such as oiling ,greasing , clamp ,clips etc and keeping in safe custudy in servicable condition and refixing the same after repair works of building completed all as specified and as directed .
S & F Exhaust Fan , AC , Single phase ,230/240V , 82 Watt , of 300 mm sweep, 1400 RPM with louvers etc complete including making holes on wall and fixed by providing necessary fixing arrangements such as fastener of approped make , bolts, nuts and washers etc and making electric connection with suitable size of copper conductor from ceiling rose etc complete and making good disturbed surfaces matching with the existing surfaces : Make : Model TURBO FORCE of Havells or equivalent in Philips/Bajaj/Wipro/Crompton
S&F 1100 Volts grade heavy duty cable PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape & overall PVC sheathed in service connection suspended by insulating hanger not more than 1 meter apart including 4 mm GI suspension wire one twin core cable flat or circular of size 6 Sq mm to be connected to existing MCB box / Main switches complete all as specified as directed.
S&F 1100 Volts grade heavy duty cable PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape & overall PVC sheathed in service connection suspended by insulating hanger not more than 1 meter apart including 4 mm GI suspension wire one twin core cable flat or circular of size 10 Sq mm to be connected to existing MCB box / Main switches complete all as specified as directed.
S & F in replacement house service bracket (hook type) made of GI pipe 32 mm dia medium grade 3.0 m long made to shape bend at 90/120 degree as directed and incl providing M.S. stay made of flat iron 30x5 mm thick made to shape incl providing nuts, bolts and washers etc complete and as directed .
Excavation in trenches in any type of soil not exe 1.5 mtrs wide and not exe 1.5 mtr in depth for laying of pipe/cables etc and getting out incl forming bottom surface to the required level/slope etc complete all as specified and directed .
Returning fitting in soft/loose soil, including spreading levelling watering and well ramming in layers n.exc 25 cm complete all as directed
Removing excavated soils to a distance n.exc. 50 mtrs and depsiting where directed at a level n.exc. 1.5 above the starting point complee all as specified and directed
M&L for sand dry ,clean free from sharp materials filling in trenches for cable protection ( 8 cm coushion below cable and 15 cm after laying of cable gently punned down to a depth of 10 cm above the top of the upper-most cable ) etc complete all as specified and directed. Note : Punned sand shall be measured and paid .
Supplying and laying Precast concrete cable cover class LV type -I flat size 250x150x40 mm laid parpendicular to the axis of cable in trenches etc complete as directed. Make: Make: M/S MEHATAB TILES, Rani Shopping Centre, Bhanwar, Indore,(B) M/S NAVYA TILES, 68, NEHRU PARK, SARDARPUR,JODHPUR- 342003 Ph. 0291-2650094, 2627963(C) SAP PAVERS JODHPUR (D) SAGAR TILES SAHARANPUR (E) Star Tiles & Industries, Rama Devi, Kanpur
S&F in replacement GI tubing , 50 mm bore , light grade, ISI marked with fittings laid in trenches/ fixed with walls/ poles etc as protection to cables complete as ditrected
S&F in replacement GI tubing , 80 mm bore , light grade, ISI marked with fittings laid in trenches/ fixed with walls/ poles etc as protection to cables complete as ditrected
Supply ,Laying and testing Cable XLPE Insulated ,screened , PVC bedded Galvinised Steel strip or wire armoured ,electric power cables (heavy duty )1100 Volts grade with standared aluminium conductorof size 16 Sq mm 4 core to be connected to existing MCB box / Main switches complete all as specified as directed.
Supply ,Laying and testing Cable XLPE Insulated ,sceened , PVC bedded Galvinised Steel strip or wire armoured ,electric power cables (heavy duty )1100 Volts grade with standared aluminium conductorof size 25 Sq mm 4 core to be connected to existing MCB box / Main switches complete all as specified as directed.
Supply ,Laying and testing Cable XLPE Insulated ,screened , PVC bedded Galvinised Steel strip or wire armoured ,electric power cables (heavy duty )1100 Volts grade with standared aluminium conductorof size 35 Sq mm 3.5 core to be connected to existing MCB box / Main switches complete all as specified as directed.
S&F 1100 Volts grade heavy duty cable PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape & overall PVC sheathed in service connection suspended by insulating hanger not more than 1 meter apart including 4 mm GI suspension wire one twin core cable flat or circular of size 10 Sq mm to be connected to existing MCB box / Main switches complete all as specified as directed.
M&L for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick weithing not less than 17.5 Kg buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth lead wire 4.00 mm dia by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 15 mm bore( light grade) and watering pipe 20 mm bore GI pipe (light grade) and chamber of pcc 1:4:8 type D2 using 40 mm graded stone aggregate and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg. 50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 3 of SSR PT 1, 2009 with charcoal dust and salt complete and earth lead connected to earthing test point (up to main switches, DBs) complete all as specified & testing on completion. NOTE:- (I) item includes the cost of 7.5 mtr length GI pipe for protection for GI earth wire. (ii) item rates includes the cost of 7.5 mtr earth lead GI earth wire. (iii) PCC pit shall be provided at least 500mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe,bends,elbow etc shall be deemed included in the unit rate. Make of earth electroc : M/s Kapilansh/Ashlok/JMV
S & F in replacement of main switch switch 415 Volt in sheet metal enclousure , 4 pole , Capacity 100 Amps including all necessary connection inlcuding acessouries all as specified and directed . Make : Areva/Havells/HPL/L&T /Siemens/Standrad/Indo Asian/CG/Shalabh/GE India /C&S
M/s Hansraj Shivhare
M/S RAJ KUMAR SINGH
M/s Ravi Traders
J K Enterprises
JAI BALAJI CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .