Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.9 LAccepted-AOC BUILDING NO FLAT NO 19 6TH CROSS ROAD SANJEEVINI NAGAR MUDALAPALYA BANGALORE 560072 | BANGALORE | BANGALORE | KARNATAKA | 560072 | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹30.5 L+₹1.6 L (5.64%)Rejected-AOC WZ 831 NANGAL RAYA PANKHA ROAD NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L2 | Rejected-AOC Not L1 Bidder | |
| 3 | L3₹30.5 L+₹1.7 L (5.79%)Rejected-AOC | L3 | Rejected-AOC Not L1 Bidder | |
| 4 | L4₹31.0 L+₹2.1 L (7.33%)Rejected-AOC | L4 | Rejected-AOC Not L1 Bidder | |
| 5 | L5₹32.2 L+₹3.3 L (11.5%)Rejected-AOC RZ 140 A EAST SAGARPUR STREET NO 7 8 NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L5 | Rejected-AOC Not L1 Bidder |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
1 Feb 2024, 6:00 pmClosed
GE U WATER SUPPLY DELHI CANTT 10
GE U WATER SUPPLY DELHI CANTT 10
PETTY REPAIR FOR ATTENDING DAY TO DAY EM EXTERNAL WATER SUPPLY COMPLAINTS AND ELECTRICAL COMPLAINTS AT RANGPURI AND REPAIR MAINT OF FIRE FIGHTING MISC WORKS IN THE AREA OF AGE U WATER SUPPLY NO III UNDER GE U WATER SUPPLY DELHI CANTT 10
2024_MES_635811_1
GE/WS/IFA-112/Token-62 OF 2023-24
Open Tender
Civil Works
Item Rate
330 days
GE U WATER SUPPLY DELHI CANTT 10
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
GE U WATER SUPPLY DELHI CANTT 10
₹84,000
Yes
5 Apr 2024
4 Jan 2024
3 Feb 2024
4 Jan 2024
1 Feb 2024
18 Jan 2024
Amount
Labour only for attending day to day external/treated water supply complaints of all nature including grey water pipe leakage i.e leakage in water supply pipe lines, fitting/fixture, over flow of overhead tank, no water supply in supply tank/direct kitchen tap and taking out water from trenches during repair including write down the complaints in complaint register complete all as specified and as directed. (Note 1 :- Any material required for attending complaints for rectification shall be measured and paid separately under respective item herein after) (Note 2 :- Quoted rates includes following other aspects as srl No. 3 (i) to 3 (x) below).
Labour only for attending of Electric supply compliants of day to day maintenace of existing LT Panels including connecting electrical accessories / spares of water supply installation and electrical fitting & light, short circuits in Pump house complete all as specified and as directed.(Any material required for attending complaints shall be measured & paid separately under respectvie item hereinafter) (Note 1 :- Any material required for attending complaints for rectification shall be measured and paid separately under respective item herein after) (Note 2 :- Quoted rates includes following other aspects as srl No. 3 (i) to 3 (x) below).
Notes for item No. 1.00 & 2.00 (i) The complaints shall be attended and the defects shall be rectified by a team of expert and experienced electrician/plumber as applicable assisted with adequate numbers of helpers complete all as specified and as directed. Minimum requirements of skilled and unskilled workers for whole contract period are as under:- (a) One plumber or fitter with one helper. (b) One Electrician or fitter with one helper. (ii) Requirement of additional workers if required for rectification of any complaint (occationally) will be provided by contractor on urgent requirement basis as directed by EIC without any extra cost.
(iii) The complaints shall be attended and defect shall be rectified within 04 hrs commencing from date and time of notifying the complaint failing which a penalty @ Rs 250/- per complaint per day (08 hrs) shall be levied upon/imposed on the contractor and recovery shall be made from contractor's dues. Contractor shall appoint suitable staff for receive and register of complaints received in person/through telephone/mobile and issue and control contractors stores and workers will required to available within time daily at 0800 hrs to 2000 Hrs to receive and notify each complaint. Attendence register of workers daily basis will provided by contractor duly signed by JE E/M & Eng-in-Charge.
(iv) In case, after checking and attending the defect, it is not possible to rectify the defects within 08 hrs the facts shall be brought to the notice of Engineer-in -charge by the contractor /his rep . If Engineer -in-charge is satisfied with contractors view, no recovery will be made.
(v) While attending the complaint of water supply /Electric supply if earth work is required then the same shall be measured and paid seperately under respective item of Sch 'A' . However no extra payments shall be made for dewatering.
(vi) Cutting of GI pipe in position and threading is also deemed to be included in the job rate (Fitting and fixtures will be measured and paid separetely under respective item of Sch A.
(vii) All T & P including safety gears required for attending the complaints shall be provided by the contracor.
(viii) The elecrician shall always be in possession of all Electrician tools , LT Megger, Earth tester , Multimeter , Crimping tool, insulation tape, Hand gloves etc required at site.
(ix) Old retrived materials, will be deposited by contractor to store yard of AGE (U) Water Supply No III and necessary RV attached with RAR / Final bill mentioning ledger number & page number. (x) All the fitting /fixtures as mention below item No 4 to 22.05 and 47 to 49.03 of BOQ shall be procured by contractor in one time and the same shall be kept with safe custory of Eng-in-charge store and issue RV to contractor. Piecmeal requirement of fixing of fittings as required at site will be issued by JE (E/M) through Baby indent. Proper register will maintained by contractor for consumption of materials at site with showing debit complaint wise. The same register will not signed by JE (E/M) & Eng-in-Charge and produced with RAR/Final bill. (xi) First RAR will be submitted by contractor for material lying at site only.
Supply only GI Socket 'medium grade' ISI Marked of following sizes :-
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
Supply only GI Elbow 'Medium grade', ISI Marked of following sizes : -
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50mm bore
Supply only GI Union 'Medium grade', ISI Marked of following sizes : -
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
Supply only 'GI Nipple' of different length as per requirement of suitable length both end screwed 'Medium Grade', ISI marked of following sizes:
15 mm bore
20 mm bore
25 mm bore
40mm bore
50mm bore
Supply only GI Reducing socket medium grade ISI marked of the following sizes :-
25 mmx15mm bore
20mmx15mm bore
25 mm x 20 mm bore
50 mmx 40mm bore
Supply only GI Tee Medium grade ISI Marked of following sizes : -
15mm x15mm x15mm
20 mm x 20 mm x 15 mm
20 mm x 20 mm x 20 mm
25 mm x 25 mm x 15 mm
25 mm x 25 mm x 20 mm
25 mm x 25 mm x 25 mm
40 mm x 40 mm x 15 mm
40 mm x 40 mm x 20 mm
40 mm x 40 mm x 25 mm
40 mm x 40 mm x 40 mm
50 mm x 50 mm x 15 mm
50 mm x 50 mm x 20 mm
50 mm x 50 mm x 25 mm
50 mm x 50 mm x 40 mm
50 mm x 50 mm x 50 mm
Supply only GI Solid plug heavy duty ISI Marked of following sizes : -
Supply only PVC 'L' type Holder suitable for Aluminium rod,Float Ball etc all as required at site and complete all as specified and as directed of following Sizes:-
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
Supply fixing of PTMT float valve, Sizes as under, with epoxy coated aluminium rod and high density plastic ball complete all as specified and as directed.
PTMT float valve, 15 mm bore
PTMT float valve, 20 mm bore
PTMT float valve, 25 mm bore
PTMT float valve, 40 mm bore
PTMT float valve, 50 mm bore
Taking up or down GI steel tubing of following sizes with connections from Trenches/floors/walls including cleaning for refixing or removal complete all as specified and as directed. Note :-Excavation & earth work shall be measured & paid separetely.
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
Refixing old steel tubing and connections in new or old position(wall/ ceiling/ floor) of following sizes complete all as specified and as directed. Note :- (i) Excavation for new location shall be measured & paid separetely. (ii) Serviceable tubing obtained from item No 13 shall be used for re-fixing.
GI steel tubing, 15 mm bore
GI steel tubing, 20 mm bore
GI steel tubing, 25 mm bore
GI steel tubing, 40 mm bore
GI steel tubing, 50 mm bore
Supply & fixing of GI steel tubing medium grade of following size in old or new position as in ceiling/walls/Floors with necessary fixing arrangements and including providing new GI fittings complete all as specified and as directed. Note :- (i) Excavation & earth work for new locations shall be measured & paid separetely. (ii) GI fittings should be measured and paid under respective items.
GI steel tubing, 15 mm bore
GI steel tubing, 20 mm bore
GI steel tubing, 25 mm bore
GI steel tubing, 40 mm bore
GI steel tubing, 50 mm bore
Supply and Fixing Gun metal gate valve, with iron wheel head screwed both ends for iron pipe as per IS-778 and fixed including taking out unserviceable one, complete all as specified and as directed of following sizes.
Gun metal gate valve, 15 mm bore
Gun metal gate valve, 20 mm bore
Gun metal gate valve, 25 mm bore
Gun metal gate valve, 40 mm bore
Gun metal gate valve, 50 mm bore
Cutting and screwing the existing steel tubing of following size bore for addition & alteration or lengthening screw on pipe to form connector complete all as specified and as directed.
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
Supply and fixing in replacement UPVC Socket, ISI Marked complete all as specified and as directed of following sizes
UPVC Socket 15 mm bore
UPVC Socket 20 mm bore
UPVC Socket 25 mm bore
UPVC Socket 40 mm bore
UPVC Socket 50 mm bore
UPVC Socket 90 mm bore
UPVC Socket 110 mm bore
Supply and fixing in replacement UPVC Elbow, ISI Marked complete all as specified and as directed of following sizes
UPVC Elbow 15 mm bore
UPVC Elbow 20 mm bore
UPVC Elbow 25 mm bore
UPVC Elbow 40 mm bore
UPVC Elbow 50 mm bore
UPVC Elbow 90 mm bore
UPVC Elbow 110 mm bore
Supply and fixing in replacement UPVC reducing socket, ISI Marked complete all as specified and as directed of following sizes.
UPVC reducing socket size 20 x15 mm bore
UPVC reducing socket size 25 x15 mm bore
UPVC reducing socket size 25 x20 mm bore
UPVC reducing socket size 40 x20 mm bore
UPVC reducing socket size 50 x20 mm bore
UPVC reducing socket size 50 x40 mm bore
Supply and fixing in replacement UPVC Tee, ISI Marked, complete all as specified and as directed of following sizes
UPVC Tee , 15 x 15 x 15 mm bore
UPVC Tee , 20 x 20 x 15 mm bore
UPVC Tee , 20 x 20 x 20 mm bore
UPVC Tee , 25 x 25 x 25 mm bore
UPVC Tee , 40 x 40 x 40 mm bore
UPVC Tee , 50 x 50 x 50 mm bore
Supply and fixing in replacement UPVC Solid plug, complete all as specified and as directed of following sizes.
UPVC plug, 15 mm bore
UPVC plug, 20 mm bore
UPVC plug, 25 mm bore
UPVC plug, 40 mm bore
UPVC plug, 50 mm bore
M&L for Disconnection electrical and water connection of the 12.5 HP centrifugal pump and motor with base plate and transported to work shop opening carefully and replacement of bushes, gland packing, ball bearing, rubber gasket nut and bolt fixing the require new parts(parts such as shaft, impellor, coupling & bearing shall be supplied under relevant item of schedule) and complete re-fixing its in original position and making out all electrical and water connection and testing complete all as specified and as directed by the Engineer-in-Charge. (Note :- (i) Rate includes transportation of motor from the place of installation for repairing and reinstalling the same on existing foundation & testing & commisioning. (ii) Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of iron scrap in weight (KG) shall be taken into account and attach with RAR/F Bill) (iii) Spare parts will be measured and paid seperately as supply only in respective items.
Supply only shaft suitable for centrifugal pumps
Supply only GM impeller suitable for centrifugal pumps
Supply only MS coupling suitable for centrifugal pumps
Supply only bearing suitable for centrifugal pumps
Supply and fixing Switch Piano flush type 6 amps single pole one way 240 volts complete all as specified and as directed.
Supply and fixing Switch Piano flush type 16 amps, single pole, one way, 240 volts complete all as specified and as directed.
Supply and fixing Switch Socket outlet 2 in 1, 3 pin, 6 amps 240 volts complete all as specified and as directed.
Supply and fixing Switch Socket outlet 2 in 1, 3 pin, 6 and 16 amps 240 volts complete all as specified and as directed.
Supply and fixing in replacement Switch Socket combination 2 in 1, 3 pin, 6 amps 240 volts complete all as specified and as directed.
Supply and fixing in replacement Switch Socket combination 2 in 1, 3/5 pin, 6 and 16 amps 240 volts complete all as specified and as directed.
Supply and fixing in replacement MCB SP, 6 to 32 Amp, 240 volts complete all as specified and as directed.
Supply and fixing in replacement LED batten arrow for multi application suitable for 18 Watts with & including necessary cable connection to make it functional complete all as specified and as directed.
Supply and fixing in replacement non metallic PVC conduit 25 mm bore, medium grade having 2 mm wall thickness with & including all fittings such as tee,bends, reducer, elbow, bell mouth, tube ends etc with all other fixing accessories such as couplers, locknuts saddles, pipe hooks, clips etc complete all as specified and as directed.
Supply and fixing in replacement sheet metal enclosure MCB,DB 4 way, with 200 amps rated bus bar SPN,240 volts double door and making disturb surface good complete all as specified and as directed.
Supply and fixing in replacement sheet metal enclosure MCB,DB 8 way, with 200 amps rated bus bar SPN,240 volts double door and making disturb surface good complete all as specified and as directed.
Supply and fixing in replacement PVC multistranded aluminium conductor, 1100 volts grade , cross sectional area 4 sqmm, 2 core fixed on panels/walls complete all as specified and as directed.
Supply and fixing in replacement PVC multistranded aluminium conductor, 1100 volts grade , cross sectional area 6 sqmm, 2 core fixed on panels/walls complete all as specified and as directed. Note for item No 28 to 40 : - (i) Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of fitting and wire scrap in weight (KG) shall be taken into account and attach with RAR/F Bill) (ii) Making good cost of existing surface shall be included in quoted unit rate.
M&L for rewinding of electrical motor 12.5 HP with super enameled copper winding wire of suitable size not less than original after cutting and taking out old winding complete with all insulation material such as Cotton top varnish etc of centrifugal pump set motor complete all as specified and as directed by the Engineer-in-Charge. (Note for item No 41 to 43:- (i) Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of old copper winding lead pig & spun yarn shall be taken in charge in weight (KG) shall be taken into account and attach with RAR/F Bill) (ii) Transportation charges of motor included in quoted unit rate.
Supply and fixing lead pig for joints complete all as specified and as directed.
Supply and fixing Spun Yarn complete all as specified and as directed.
Supplying and fixing in replacement UPVC pipes, of following sizes, pressure rating 10 kgf/cm2, heavy duty, including taking out with all pipe fittings such as ends, elbows,unions, tees, reducing tees, adoptors, sockets, plugs, hose clips etc. fixed to walls with fixing arrangements such as saddles (snap clips), wall clips, hooks, protective mild steel tube sleeves , ceilings or in floors etc., complete with and cutting through walls, floors and their making good or laying in trenches and also cutting, screwing and waste including jointing with jointing material complete all as specified and as directed. (Note :- (i) Excavation & earth work for new location shall be measured & paid separetely. (ii) Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of plastic scrap in weight (KG) shall be taken into account and attach with RAR/F Bill)
15 mm Bore
20 mm Bore
25 mm Bore
40 mm Bore
50 mm Bore
90 mm Bore
110 mm Bore
Supply & fixing of CI/ DI Pipe fittings such as Tees, bends ,any type, radius and angle/tapers any type, collars,tail pieces,caps and plugs up to 150 mm bore conforming to IS: 1538-1993 including taking down existing fitting complete all as specified and as directed.
Supply & fixing of CI/ DI Pipe fittings such as Tees, bends ,any type, radius and angle/tapers any type, collars,tail pieces,caps and plugs 200 to 300 mm bore conforming to IS: 1538-1993 including taking down existing fitting complete all as specified and as directed. (Note for item No 45 & 46 :- (i) ld U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill) (ii) Excavation and earth work will be measured and paid seperately.
Supply only 15 mm bore Bib tap of PTMT, any tint, high pressure screwed for male/ female threaded, for pipe of size 15 mm bore complete all as specified and as directed.
Supply and fixing PPR Gate valve(Brass inserted), ISI Marked of following size, Complete all as specified and as directed.
20 mm Bore
40 mm Bore
50 mm Bore
Supply and fixing in replacement PPR male threaded adopter, ISI marked of following size, Complete all as specified and as directed.
20 mm Bore
40 mm Bore
50 mm Bore
Supplying and fixing Digital liquid water level monitor/controller with inovate PIEZO-RESISTIVE linear sensor, non ambiguous display 3 x 1/2 digit (1999 count max) unit option any two of cm,ltrs,percent(%) resolution 0.1 for % and One cm upto 20 mtrs deep tank DATUM level adjustable, power 10-14 VDC ( 5 watts),temp 0.55 degree celcius, relay No 230 VAC, 6 Amp, sensor to tripod to make it fully serviceable/functional by renewal of defective parts, for semi under ground sump after taking down/out as existing at site complete all as specified and as directed. (Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of iron scrap in weight (KG) shall be taken into account and attach with RAR/F Bill)
Supplying and fixing three core poly tetra flouro ethylene teflon silcer plated copper wire shielded temp range 40 degree to 240 degree, size 0.25 Sqmm (24/7/32) after taking down/out as existing at site complete all as specified and as directed. (Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of plastic scrap in weight (KG) shall be taken into account and attach with RAR/F Bill)
Excavation in trenches not exc 1.5 M wide and not exc 1.5 M in depth for pipe line, etc in soft/ loose soil getting out and levelling of bottom surface to required level all as specified and as directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick complete all as specified and as directed.
Removing excavated material to a distance not exc 50 m and depositing where directed not exc 1.5 meters above the starting point complete all as specified and as directed.
Supply and fixing in replacement of LED Bldg Security Lights 60 watts IP 66 including box, trasparent cover of ABS Body, Resistance and capacity complete all as specified and directed. (Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of iron scrap in weight (KG) shall be taken into account and attach with RAR/F Bill)
Supply and fixing in replacement of MCCB 4 pole 250 Amps 35 KA complete all as specified and directed.
Supply and fixing in replacement of MCCB 4 pole 200 Amps 35 KA complete all as specified and directed.
Supply and fixing in replacement of MCCB 3 pole 100 Amps 25 KA complete all as specified and directed.
Supply and fixing in replacement of MCCB 3 pole 63 Amps 25 KA complete all as specified and directed. (Note for item No 56 to 59:- ld U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of iron scrap in weight (KG) shall be taken into account and attach with RAR/F Bill)
Supply and fixing Single headed Gun Metal fire hydrant landing valve type A (single head outlet) of 80mm dia landing valve with 63mm dia female outlet complete and 80mm inlet with rubber blank cap and chain as per IS 5290-1983, suitable for brigade hose of 63mm with couplings conforming to IS 903 including taking down the existing one complete all as specified and directed. (Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of hydrant in (EACH) shall be taken into account and attach with RAR/F Bill)
Supply and fixing of weather proof standard fire hose box made of 16 SWG gauge MS Sheet 750mm x 600mm x 250mm with double door with 4mm thick glasses and door frame including locking arrangement by allen key, stove enamelled fire red finish with 'Fire hose' marked on front and brilliant white inside yard, suitable for housing of 2 lengths RRL hose pipe conforming to IS:636-1979 (type-II) of 63mm dia. GM instataneous male and female coupling (IS:903) and branch pipe and nozzel 12.5mm dia including taking down the existing one complete all as specified and directed . (Note:- ld U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of hose box in (EACH) shall be taken into account and attach with RAR/F Bill)
Supply and fixing in position 63mm nominal bore and 15 mtr long synthetic fibre, circular woven jacketed, rubberized fabric reinforced rubber lined (RRL) fire hose pipe of approved make bearing IS : 636-1988 type A mark and having TAC and MMD approval with a pair of 63 x 63 mm gun metal instantaneous type, heavy duty delivery hose coupling (conforming to IS : 903) bound and riveted to the hose pipe with copper rivets and copper wire, complete all as specified and including taking down the existing one complete all as specified and directed . (Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of RRL fire hose pipe in weight (KG) shall be taken into account and attach with RAR/F Bill)
Supply and fixing in position Gun Metal 63mm dia short size branch pipes with 20 mm dia nozzles with 63mm instantaneous coupling ISI marked (IS: 903). and including taking down the existing one complete all as specified and directed. (Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of Nozzles in (EACH) shall be taken into account and attach with RAR/F Bill)
Supply, fixing, testing and commissioning of wall mounting swinging type First aid fire hose reel with drum, hanging bracket,Thermoplastic rubber (first aid hose) as per IS 12585 20 mm dia 30 mtr length to with stand 10 kg per Sq cm working pressure fitted with gunmetal nozzle and shut off valve of any size complete all as specified. The hose reel shall be conforming to IS 884-1985 including for 25 mm dia MS pipe connection from riser to hose reel sockets,nipples,elbows,valve etc. Drum shall be fixed on adjoining wall through anchor fasteners/cement concrete hook or MS stand as per site requirement and the rate for fixing/hanging items in the rates quoted(for internal hydrant and one each an either side of stage) including taking down the existing one complete and depositing to MES store yard all as specified and directed . (Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of hose reel in (EACH) shall be taken into account and attach with RAR/F Bill)
Supply and fixing water delivery Thermoplastic rubber (first aid hose) as per IS 12585 20 mm dia 30 mtr length to with stand 10 kg per Sq cm working pressure fitted with gunmetal nozzle and shut off valve of any size complete and depositing to MES store yard complete all as specified and directed. (Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of first aid hose in (EACH) shall be taken into account and attach with RAR/F Bill)
Supplying & fixing in replacement Co2 type 4.5 kgs capacity Fire Extinguisher, assembled from brand new Explosives approved cylinders, complete with screw-down type valve, internal discharge tube, one metre high pressure rayon braided hose, discharge, horn, Bearing ISI Mark IS: 2878. Co2 Cylinder as per IS: 7285 CCE approved ‘ISI’ Valve as per IS: 3224. Co2 Gas as per IS: 15222. internal discharge tube IS: 738. Discharge duration, 10-18 secs. Filled weight of extinguisher, 17 kgs. Tested to 250 kgf/cm2 complete all as specified and as directed . (Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of extinguisher in (EACH) shall be taken into account and attach with RAR/F Bill)
Supplying & fixing in replacement ABC type Stored Pressure 6 kgs capacity Fire Extinguisher, fabricated from MS sheets, fitted with brass forged squeeze grip valve assembly incorporated with pressure gauge, initial charge of 5 kgs. ABC Powder(MAP 50%) and pressurized with nitrogen gas. M.S. Body as per IS : 513 Forged Brass valve as per IS: 6912. Bearing ISI Mark IS: 13849 complete all as specified and as directed . (Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of ABC type in (EACH) shall be taken into account and attach with RAR/F Bill)
Supplying & fixing in replacement Mechnical Foam AFFF (Stored Pressure ) 9 Ltr capacity Fire Extinguisher, fabricated from MS sheets, fitted with brass forged squeeze grip valve assembly incorporated with pressure gauge and pressurized with nitrogen gas. M.S. Body Epoxy Polyester Powder Coating and AFFF as per IS 4989 ,Hydraulic test pressure 35 kg/cmm2 and Extinguisher as per IS: 15683 complete all as specified and as directed . (Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of AFFF in (EACH) shall be taken into account and attach with RAR/F Bill)
Supply, fixing, testing and commissioning of 150 dia mm pipe heavy duty class "c" MS pipe ,ISI marked as per IS: 1239 with all necessary fittings & fabrication like tees, elbows, flanges, reducers, gaskets, nuts and bolts etc welding or screwed joints as required including fixing of pipe with necessary standard clamps structural steel supports as required/directed at site including painting of two coats of synthetic enamel paint of post office red colour over a coat of red oxide primer including taking down the existing one complete all as specified and directed . (Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of pipe in weight (KG) shall be taken into account and attach with RAR/F Bill)
Supply, fixing, testing and commissioning of 100 dia mm pipe heavy duty class "c" MS pipe ,ISI marked as per IS: 1239 with all necessary fittings & fabrication like tees, elbows, flanges, reducers, gaskets, nuts and bolts etc welding or screwed joints as required including fixing of pipe with necessary standard clamps structural steel supports as required/directed at site including painting of two coats of synthetic enamel paint of post office red colour over a coat of red oxide primer including taking down the existing one complete all as specified and directed . (Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of pipe in weight (KG) shall be taken into account and attach with RAR/F Bill)
Supply, fixing, testing and commissioning of 80 dia mm pipe heavy duty class "c" MS pipe ,ISI marked as per IS: 1239 with all necessary fittings & fabrication like tees, elbows, flanges, reducers, gaskets, nuts and bolts etc welding or screwed joints as required including fixing of pipe with necessary standard clamps structural steel supports as required/directed at site including painting of two coats of synthetic enamel paint of post office red colour over a coat of red oxide primer including taking down the existing one complete all as specified and directed . (Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of pipe in weight (KG) shall be taken into account and attach with RAR/F Bill)
Supply, fixing, testing and commissioning of 25 dia mm pipe heavy duty class "c" MS pipe ,ISI marked as per IS: 1239 with all necessary fittings & fabrication like tees, elbows, flanges, reducers, gaskets, nuts and bolts etc welding or screwed joints as required including fixing of pipe with necessary standard clamps structural steel supports as required/directed at site including painting of two coats of synthetic enamel paint of post office red colour over a coat of red oxide primer including taking down the existing one complete all as specified and directed . (Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of pipe in weight (KG) shall be taken into account and attach with RAR/F Bill)
Supply, fixing, jointing & testing cast Iron Sluice Valve of size 80 mm dia ISI Marked, flanged ends drilled pressure rating PN-1.0, PD Short body, Confirming to IS 14846 -2000, having stainless steel spindle with cast iron operation wheel at top including taking out unserviceable sluice valve complete all as specified and as directed . (Note:- (i) Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item. (ii) Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in of sluice valve weight (KG) shall be taken into account and attach with RAR/F Bill)
Supply, fixing, jointing & testing cast Iron Sluice Valve of size 100 mm dia ISI Marked, flanged ends drilled pressure rating PN-1.0, PD Short body, Confirming to IS 14846 -2000, having stainless steel spindle with cast iron operation wheel at top including taking out unserviceable sluice valve complete all as specified and as directed . (Note:- (i) Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item. (ii) Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of sluice valve in weight (KG) shall be taken into account and attach with RAR/F Bill)
Supply, fixing, jointing & testing cast Iron Sluice Valve of size 150 mm dia ISI Marked, flanged ends drilled pressure rating PN-1.0, PD Short body, Confirming to IS 14846 -2000, having stainless steel spindle with cast iron operation wheel at top including taking out unserviceable sluice valve complete all as specified and as directed . (Note:- (i) Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item. (ii) Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of sluice valve in weight (KG) shall be taken into account and attach with RAR/F Bill)
Supply, fixing, jointing & testing cast Iron Sluice Valve of size 200 mm dia ISI Marked, flanged ends drilled pressure rating PN-1.0, PD Short body, Confirming to IS 14846 -2000, having stainless steel spindle with cast iron operation wheel at top including taking out unserviceable sluice valve complete all as specified and as directed . (Note:- (i) Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item. (ii) Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of sluice valve in weight (KG) shall be taken into account and attach with RAR/F Bill)
Supply, fixing, jointing and testing of Cast iron Non Return valve of size 80 mm dia without by pass arrangement , Swing type, confirming to IS 5312, flanged ends pressure rating PN 1.0 complete including taking out unserviceable NRV complete all as specified and as directed . (Note:- (i) Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item. (ii) Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill)
Supply, fixing, jointing and testing of Cast iron Non Return valve of size 100 mm dia without by pass arrangement , Swing type, confirming to IS 5312, flanged ends pressure rating PN 1.0 complete including taking out unserviceable NRV complete all as specified and as directed . (Note:- (i) Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item. (ii) Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill)
Supply, fixing, jointing and testing of Cast Iron Butterfly Valve of size 80 mm dia ISI marked class (PN 1.0) including taking out unserviceable Butterfly valve complete all as specified and as directed . (Note:- (i) Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item. (ii) Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill)
Supply, fixing, jointing and testing of Cast Iron Butterfly Valve of size 100 mm dia ISI marked class (PN 1.0) including taking out unserviceable Butterfly valve complete all as specified and as directed . (Note:- (i) Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item. (ii) Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill)
Supply, fixing, jointing and testing of Cast Iron Butterfly Valve of size 150 mm dia ISI marked class (PN 1.0) including taking out unserviceable Butterfly valve complete all as specified and as directed. (Note:- (i) Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item. (ii) Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill)
Supply, fixing, jointing and testing of Cast Iron Slim seal dual plate wafer type check valve of size 100 mm dia ISI marked class (PN 1.0) including cutting the existing pipe ,complete all as specified and as directed. (Note:- (i) Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item. (ii) Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill)
Supply, fixing, jointing and testing of Cast Iron Slim seal dual plate wafer type check valve of size 150 mm dia ISI marked class (PN 1.0) including cutting the existing pipe ,complete all as specified and as directed . (Note:- (i) Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item. (ii) Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill)
Supply, fixing, jointing and testing in replacement of Bourdon type pressure gauge with gun metal isolation cock and copper ‘U’ Tube.having calibration of 0-10 Kg/cm2 ,and 100 mm dial size all as specified including taking out unserviceable pressure gauge complete all as specified and as directed . (Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill)
Supply, fixing, jointing and testing in replacement of Pressure switches IPS 100 or approved equivalent) including making connections with the control panel and the pressure vessel complete in all respects.The electrical continuity is maintained between contacts NC& COM under normal conditions. The contacts changeover to NO & COM on rise of pressure to preset value all as specified including taking out unserviceable pressure switch complete all as specified and as directed. (Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill)
Supply, fixing, jointing and testing in replacement of Gun metal Air release valve of size 25mm dia having rubber ball ( of suitable range and calibrated) complete screwed both ends for iron pipe, ISI Marked, as per IS: 778 of following sizes including taking out unserviceable air release valve complete all as specified and as directed. (Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill)
Disconnecting & taking out unserviceable Gun metal 3 way Fire brigade inlet to down commer line dismantling and opening carefully for servicing over hauling shifted to and fro to workshop,material and labour for replacement of unserviceable &worm out GM Parts and rubber packing BNW etc complete and refixing same in position and testing all as specified and as directed . (Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill)
Disconnecting & taking out unserviceable 100 mm dia Non Return Valve dismantling and opening carefully for servicing over hauling shifted to and fro to workshop,material and labour for replacement of unserviceable & worm out SS flapper,square Nut,Body Nut- Bolts,Gland nut -bolts,Gland packing etc,including machining and greasing,reassembling and refixing in position and testing complete all as specified and as directed. (Note - (i) The cost of washers,gaskets and gun metal flaper & stinless steel spindle of non return valve packing nut bolt etc shall be deemed to be included in the quoted rates. (ii) Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill)
Material and labour for in repairs / fabrication of base frame with MS Chanel MC-25/50/75/100/125 for foundation of centrifugal pump set incl two coat red oxide and black enamel paint complete all as specified and as directed (Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill)
Taking out old rusty MS base frame incl dismentling the pump & moter, breaking PCC foundation complete all as per the site requirement and complete all as specified and as directed . (Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill)
Material and labour for painting with synthetic enamelled paint as per approved colour code of fire fighting Riser Pipe line in Fire nitch ground floorto terrace pipe lines inside the shaft complete all as specified and as directed .
Material and labour for painting with synthetic enamelled paint as per approved colour code of fire fighting station induction motor coupled with fire pump on terrace pump house complete all as specified and as directed .
Supply, fixing, jointing and testing in replacement of manual call point break glass type enclosed in M S enclosures body of 3 mm thickness complete with chain and hamer and incl inscriber in case of fire break glass complete including taking down the existing one complete all as specified and directed . (Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill)
Supply, fixing, jointing and testing in replacement of electrically operated Electronic Hooter enclosed in MS enclosures of suitable size painted with sythetic enamaled paint red coloured complete with suitable transformer including taking down the existing one complete all as specified and directed by Engr-in-Charge. (Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill)
Servicing of Cubical type wall mounted fire pump control Panel for 12.5 HP Motor fabricated from 16 Swg MS sheet duly complete including replacement of UNSV parts all as specified and as directed . (Note:-Any spare parts if required deemed to be quoted in this rates.)
Supply and fixing, testing and commissioning of 3 C x 10 sq.mm. Aluminium conductor PVC sheathed armoured cable including suitable size for connection from motor to MCCB complete all as specified and as directed . (Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of aluminium in weight (KG) shall be taken into account and attach with RAR/F Bill)
Supply and fixing, testing and commissioning of 2 C x 1.5 sq.mm. solid core copper conductor PVC sheathed armoured cable including suitable size for connection from pressure switch to MCCB complete all as specified and as directed by the Engineer-in-Charge. (Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of aluminium in weight (KG) shall be taken into account and attach with RAR/F Bill)
Supply and fixing, testing and commissioning in replacement of of floor mounting type cylindrical pressure vessel with supporting legs, size 200 mm dia and 1.5 Mtr high with dished end and knuckle radius (IS:2062). The vessel shall be made of 8mm thick MS plate welded alround with sockets/flanges welded for inlet, outlet and scour pipes, pressure gauge, pressure switches, air release valve etc. of suitable required size. The pressure vessel shall be painted inside with anti-corrosive epoxy paint and outside with two or more coats of synthetic enamel paint of Fire red colour over a coat of ready mixed primer, both of approved quality, complete all as specified and as directed by the Engineer-in-Charge. (Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill)
Supplying and drawing 1.5 sqmm of PVC insulated copper conductor, single core cable in the existing surface/recessed PVC/Steel conduit /PVC casing and capping as required complete all as specified and as directed by the Engineer-in-Charge. (Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RVof copper in weight (KG) shall be taken into account and attach with RAR/F Bill)
Supply & Fixing 4 mm plain glass along with Rubber Beating etc change in FHC complete all as specified and as directed by the Engineer-in-Charge.
Supply, fixing, testing in replacement Nozzle with shut off valve including 25 mm clipco clamp for Hose Reel of any size complete all as specified and as directed by the Engineer-in-Charge. (Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill)
Servicing of Single headed Gun Metal fire hydrant landing valve type A (single head outlet) of 80mm dia landing valve with 63mm dia female outlet complete and Lugs, GM nut,Coupling complete all as specified and as directed by the Engineer-in-Charge. (Note :-Any spare parts if required deemed to be quoted rates)
Servicing ,fixing, testing of wall mounting swinging type First aid fire hose reel with drum, hanging bracket, for 25 mm dia MS pipe connection from riser to hose reel sockets,nipples,elbows,valve etc. Drum shall be fixed on adjoining wall through anchor fasteners/cement concrete hook or MS stand as per site requirement complete all as specified and as directed by the Engineer-in-Charge. (Note:- The rate for fixing/hanging items deemed to be quoted rates).
S/F in replacement Pad Lock verical type size 75mm having duplicate key 7 lever and SS Handle in Existing FHC complete all as specified and as directed by the Engineer-in-Charge. (Note:- ld U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill)
Writing letters or figures on Existing FHC/ wall (Black, Romon, Italic or Indian) with paint not exc 30cm height complete all as specified and as directed by the Engineer-in-Charge.
Taking up or down CI/DI Pipe of following sizes including all fittings) with spigot and socketed ends and lead tyton joints including burning out lead joints and recovering lead and including cleaning for refixing or removal, making good disturb surface complete all as specified and as directed. (Note:- (i) Excavation & earth work shall be measured & paid separetely. (ii) Layout plan for laying of DI pipe shall be given by EIC in writing. (iii) DI pipe whole quantity of tender shall be procured by contractor for payment in 1st RAR as material lying at site. (iv) Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill)
80 mm bore
100 mm bore
150 mm bore
Laying, jointing, testing seviceable DI Pipe after cleaning of following sizes as taking out against item S.No above laid in trenches and making good disturb surface complete all as specified and as directed .
80 mm bore
100 mm bore
150 mm bore
Supplying, Laying, jointing, testing and commmisioning DI Pipe of following sizes as per IS 8329-2000, class K-7 with inside cement mortar lining with spigot and socket ends laid in trenches complete all as specified and as directed .
80 mm bore
100 mm bore
150 mm bore
Material & Labour for run lead joint including jointing material for CI/DI Pipe of following sizes complete all as specified and as directed .
100 mm bore
150 mm bore
200 mm bore
Material & Labour for rubber gasket joint including jointing material for CI/DI Pipe of following sizes complete all as specified and as directed .
80 mm bore
100 mm bore
150 mm bore
200 mm bore
Supply, installation and testing flanged ends strainer/dirt box rating PN 10 of following sizes with stainless steel mesh suitable for cold water meter to avoid foreign material entering into meter and making good connection with flanged ends with gasket rubber sheet and nut & bolts fixing in horizontal/inclind/vertical position, including taking out unsv strainer/dirt box complete all as directed . (Note :- (i) Flange joints including jointing materials shall deemed to be included in the unit rate of this item. (ii) Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill)
100 mm bore
150 mm bore
200 mm bore
Tushar engineers
ARYA ENTERPRISES
B.R. Enterprises
Deven Associates
Sukhram & Sons
Bidder Name
Rahul Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .