Loading…
Loading…
Tender Value
₹89.4 L
EMD Value
₹1.8 L
Closing Date
28 Jan 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
+ Capital Works)
Above/Below/Par
ELECTRICAL
14 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet. Balance sheet for the 4th previous year as para 10.2 of GCC-2022 shall be considered in evaluation of financial eligibility criteria only when it is clearly certified in Annx.-VI B or a self-declared certificate duly signed by chartered accountant and the tenderer that the balance sheet of last financial year has not been audited/ yet to be prepared.
The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii)Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii)One similar work costing not less than the amount equal to 60% of advertised value of the tender. Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organisation, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate. Substantially Completed Work means an ongoing work in which payment equal to or more than 90% of the present contract value (excluding the payment made for adjustment of Price variation (PVC), if any) has been made to the contractor in that ongoing contract and no proceedings of termination of contract on Contractor's default has been initiated. The credential certificate in this regard should have been issued not prior to 60 days of date of invitation of present tender.
Definition of similar work: "Satisfactory execution of any electrical work related to HT/LT installation".
44 conditions · 8 needing a document upload
Please furnish documents in support of your claim to fulfill the eligibility criteria as mentioned in the tender documents. Each page of the copy of documents / certificates in support of credentials, submitted by the you, shall be self attested / digitally signed by the you or authorized representative of the your firm. Only those documents which are declared explicitly by you as "documents supporting the claim of qualifying the laid down eligibility criteria", will be considered for evaluating the offer or otherwise available in the offer
No deviation shall be accepted, in case of deviation in any term and condition in tender documents offer will summarily be rejected.
Requisite documents proving technical eligibility criteria and financial eligibility criteria has been uploaded along with those required as per explanation given in clause 10 of IRGCC-2022 (Works Matter).
All requisite valid documents regarding constitution of business of the bidding firm should be submitted along with the tender as per clause 14 of IRGCC 2022 (Works Matter),otherwise their offer will be considered incomplete and shall not be considered.
The tenderer whether sole proprietor / a company or a partnership firm / joint venture (JV) / registered society / registered trust / HUF / LLP etc if they want to act through agent or individual partner(s), should submit along with the tender, a copy of power of attorney duly stamped and authenticated by a Notary Public or by Magistrate in favour of the specific person whether he/they be partner(s) of the firm or any other person, specifically authorizing him/them to sign the tender, submit the tender and further to deal with the Tender/ Contract up to the stage of signing the agreement except in case where such specific person is authorized for above purposes through a provision made in the partnership deed / Memorandum of Understanding / Article of Association /Board resolution, failing which tender shall be summarily rejected. A separate power of attorney duly stamped and authenticated by a Notary Public or by Magistrate in favour of the specific person whether he/they be partner(s) of the firm or any other person, shall be submitted after award of work, specifically authorizing him/them to deal with all other contractual activities subsequent to signing of agreement, if required. Note: A Power of Attorney executed and issued overseas, the document will also have to be legalized by the Indian Embassy and notarized in the jurisdiction where the Power of Attorney is being issued. However, the Power of Attorney provided by Bidders from countries that have signed the Hague Legislation Convention 1961 are not required to be legalized by the Indian Embassy if it carries a conforming Appostille certificate. Reference: para 15 of IRGCC-2022 (Works matter),otherwise their offer will be considered incomplete and shall not be considered.
Partnership firms, if bidding for the instant tender, should submit all valid requisite documents and fulfill the stipulations as per clause 18 of IRGCC-2022 (Works Matter),otherwise their offer will be considered incomplete and shall not be considered.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Please submit your Bank details such as Name of the Bank along with Bank Branch code, account No., IFSC Code and PAN Number etc along with offer
Opening of e-tender online:- The e-tenders will be opened online using the IREPS portal. No representative is required to be present for opening of tender and taking notes of rates quoted and ranking as the complete details of rates etc. of all the bidders shall be available to the bidders in the website after the opening of the tender.
In case the date of closing mentioned in the Notice Inviting Tender is declared a holiday/bandh/strike etc. on any account, the date of closing tender online will not be changed as the application in the website of IREPS does not permit submission of any offer after closing date and time of the tender. However, opening of tenders online will be on any convenient day after the closing date/time of tenders.
All the bidders / tenderers should ensure that they are GST compliant and their quoted tax structure / rates are as per GST Law ( Ref - Railway Board letter No.2008/RS(G)/777/1 Dated - 29/5/2017 )
GCC 2022 for works Contract
he Bid Security shall be deposited either in cash through e- payment gateway or submitted as Bank Guarantee bond from a scheduled commercial bank of India or as mentioned in tender documents. The Bank Guarantee bond shall be as per Annexure- VIA and shall be valid for a period of 90days beyond the bid validity period. In case, submission of Bid Security in the form of Bank Guarantee, following shall be ensured: i. A scanned copy of the Bank Guarantee shall be uploaded on e-Procurement Portal (IREPS) while applying to the tender. ii. The original Bank Guarantee should be delivered in person to the official nominated as indicated in the tender document within 5 working days of deadline of submission of bids. iii. Non submission of scanned copy of Bank Guarantee with the bid on e-tendering portal (IREPS) and/or non submission of original Bank Guarantee within the specified period shall lead to summary rejection of bid. iv. The Tender Security shall remain valid for a period of 90 days beyond the validity period for the Tender. v. The details of the BG, physically submitted should match with the details available in the scanned copy and the data entered during bid submission time, failing which the bid will be rejected. vi. The Bank Guarantee shall be placed in an envelope, which shall be sealed. The envelope shall clearly bear the identification "Bid for the ***** Project" and shall clearly indicate the name and address of the Bidder. In addition, the Bid Due Date should be indicated on the right hand top corner of the envelope. vii. The envelope shall be addressed to Sr.DEE/G/PRYJ, DRM office Nawab Yusuf Road, Prayagraj-211001. viii. If the envelope is not sealed and marked as instructed above, the Railway assumes no responsibility for the misplacement or premature opening of the contents of the Bid submitted and consequent losses, if any, suffered by the Bidder.
Tenderers are advised to visit the site of work to ascertain all aspects of the site conditions viz accessibility, availability of approach road, nature of the soil, availability of material, availability of labour etc. that may be encountered in course of execution of work.
Tenderer should see the website for the corrigendum/addendum to the NIT/tender document, if any that may be uploaded prior to tender opening (inclusive) as there will not be any separate communication for that.
The tenderer for carrying any construction work in Uttar Pradesh must get themselves registered from the registering Officer under Section - 7 of the Building and Other Construction Workers Act, 1996 and rules made there-to by the Uttar Pradesh Govt. and submit certificate of Registration (Labour Department). For enactment of this Act, the tenderer shall be required to pay cess @ 1% of cost of construction work to be deducted from each bill.
The contractor(s) shall observe all the formalities, perform all the acts and abide by all the provisions contained in the Contract Labour Act-1970 and Contract Labour Central Rules, 1971 which in addition to other stipulations provides that the contractor(s) shall obtain license(s) from appropriate licensing officer of the area before commencement of the work and shall produce a copy thereof along with the original to the Railway office, which will be returned to the contractor after verification.
If any complaint is received against the contractor regarding violation of contract laws, (exposing Principal Employer to the risk of legal proceedings under labour laws), the guilty contractor will be black listed and their contract shall be terminated following the due procedure, apart from initiating criminal proceedings against him with the help of Labour department officials. (Authority: RB letter no.2008/E (LI)/AT/CNR/3, dated 24.01.2018).
The tenderer has to submit necessary documents in compliance of clause 10 to 18 (Part-I) of IRGCC 2022 (Works matter) mandatorily, otherwise offer will be considered as Incomplete Offer and accordingly shall not be considered.
It is the responsibility of the tenderer to see corrigendum, if any, to tender notice up to the date of tender opening. IRGCC-2022 (works matter) is for reference only. Any correction issued by competent authority up to date of opening will be applicable. Tenderer should quote accordingly.
Railways reserves the right to accept or reject any or all the tenders and to award the work in whole or in part without assigning the reason for any such action.
It is to be noted that tenderer digital signature on the E-Tender form will be considered as confirmation that tenderer have read and accepted all the conditions laid down in the documents as well as related specification of items, schedule & quantity of items in the tender, consisting of techno-commercial offer form (including special conditions attached to E-Tender) and Financial offer form.
The quantities shown in the attached Schedule are given as a guide and are approximate only and are as a guide to give the tenderer(s) an idea of quantum of work involved. Quantities are subject to variation according to the needs of the Railway. The Railway does not guarantee work under each item of the Schedule. The Railway reserves the right to increase/ decrease and/or delete or include any of the quantities given above and no extra rate will be allowed on this account.
In case of any information submitted by tenderer is found to be false forged or incorrect at any time during process for evaluation of tenders, it shall lead to forfeiture of the tender Earnest Money Deposit besides banning of business for a period of upto five years. In case of any information submitted by tenderer is found to be false forged or incorrect after the award of contract, the contract shall be terminated. Earnest Money Deposit (EMD), Performance Guarantee and Security Deposit available with the railway shall be forfeited. In addition, other dues of the contractor, if any, under this contract shall be forfeited and agency shall be banned for doing business for a period of upto five years.
Balance sheet for the 4th previous year (i.e., FY 2021-22 or as applicable for the instance tender) as per para 10.2 of GCC-2022 and para 13 of Special condition of contract of tender document shall be considered in evaluation of financial eligibility criteria only when it is clearly certified in Annex-VI B or a self-declared certificate duly signed by chartered accountant and the tenderer that the balance sheet of last financial year (i.e., FY 2024-25 or as applicable for the instance tender) has not been audited/yet to be prepared.
Electrical work in connection with "Provision of 3 unit Type-IV Qtr. at PNKD station and 1 each at BPU, MTO, RRH section under ADEN/L/CNB." Electrical work in connection with "Provision of 6 units Type-IV quarter in lieu of dismantled quarters at Loco North Railway colony under ADEN/HQ-II/CNB." and Electrical work in connection with "Manning of LC gates between DER station and NTPC/DER".
ELG-136-2526~NCR
ELG-136-2526
Open
Works - General
6 Months
Prayagraj, Uttar Pradesh
₹0
₹1.8 L
28 Jan 2026
6 Jan 2026
14 Jan 2026
54 items across 1 schedule · ₹89,36,653.1 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | Wiring for circuit / sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed PVC conduit as required. 2 x 4 sq. mm+ 1 x 4 sq. mm earth wire. | Metre | 3400.00 | 223.24 | 7,59,016 |
| 2 | Wiring for circuit / sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed PVC conduit as required. 2 x 6 sq. mm+ 1 x 6 sq. mm earth wire | Metre | 1300.00 | 273.93 | 3,56,109 |
| 3 | Wiring for circuit / sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed PVC conduit as required. 2 x 10 sq. mm+ 1 x 10 sq. mm earth wire | Metre | 750.00 | 614.72 | 4,61,040 |
| 4 | Wiring for light/power plug with 2x4 sq.mm FRLS PVC insulated copper conductor single core cable insurface/recessed medium class PVC conduit, along with 1 No. 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. | Numbers | 1250.00 | 220.01 | 2,75,012.5 |
| 5 | Supply, Erection, Testing and Commissioning of following Modular Type switch 10 A (1-way) complete in all respect. Inspection by- Consignee. | Numbers | 1600.00 | 69.93 | 1,11,888 |
| 6 | Supply, Erection, Testing and Commissioning of following Modular type Plug socket outlet 2/3 Pin 10 A complete in all respect. Inspection by- Consignee. | Numbers | 240.00 | 115.62 | 27,748.8 |
| 7 | Supply, Erection, Testing and Commissioning of following Modular Type switch 20 A (1-way) complete in all respect. Inspection by- Consignee. | Numbers | 240.00 | 142.67 | 34,240.8 |
| 8 | Supply, Erection, Testing and Commissioning of following Modular type Plug socket outlet 5/3 Pin 20 A complete in all respect. Inspection by- Consignee. | Numbers | 240.00 | 165.03 | 39,607.2 |
| 9 | Supply and Erection of Modular type switch blanking set to fill the blank space White finished mounting cover plate complete in all respect.Inspection by- Consignee. | Numbers | 380.00 | 8.46 | 3,214.8 |
| 10 | Supply and Erection of Junction Box cover POP type complete in all respect including hardware material for fixing.Inspection by- Consignee. | Numbers | 410.00 | 5.63 | 2,308.3 |
| 11 | Supply and Erection of white finish single mounting cover plate with base frame suitable 3 module suitable for mounting of Modular type piano switches/ plug Socket, fan regulator and connection to wiring.Inspection by- Consignee. | Numbers | 140.00 | 74.59 | 10,442.6 |
| 12 | Supply and Erection of white finish single mounting cover plate with base frame suitable 8 module suitable for mounting of Modular type piano switches/ plug Socket, fan regulator and connection to wiring.Inspection by- Consignee. | Numbers | 130.00 | 157.59 | 20,486.7 |
| 13 | Supply and Erection of white finish single mounting cover plate with base frame suitable 12 module suitable for mounting of Modular type piano switches/ plug Socket, fan regulator and connection to wiring.Inspection by- Consignee. | Numbers | 130.00 | 227.52 | 29,577.6 |
| 14 | Supply and Erection of Modular Metal boxes concealed Boards suitable for mounting of 3 module white finish single mounting cover plate with Frame and Modular type piano switches/ plug Socket, fan regulators. Metal board boxes are to be concealed in wall.Inspection by- Consignee. | Numbers | 140.00 | 48.94 | 6,851.6 |
| 15 | Supply and Erection of Modular Metal boxes concealed Boards suitable for mounting of 8 module white finish single mounting cover plate with Frame and Modular type piano switches/ plug Socket, fan regulators. Metal board boxes are to be concealed in wall.Inspection by- Consignee. | Numbers | 130.00 | 85.79 | 11,152.7 |
| 16 | Supply and Erection of Modular Metal boxes concealed Boards suitable for mounting of 12 module white finish single mounting cover plate with Frame and Modular type piano switches/ plug Socket, fan regulators. Metal board boxes are to be concealed in wall.Inspection by- Consignee. | Numbers | 130.00 | 138 | 17,940 |
| 17 | Supply and Installation of Ceiling rose 3 plate as per IS No. 371/1999 (Latest Version) including connections, Testing and commissioning as per Tech. Specification.Inspection by- Consignee. | Numbers | 410.00 | 16.27 | 6,670.7 |
| 18 | Supply, fixing, testing and commissioning of surface mounted/flush type power unit complete with 4 modular plate, 25 A MCB, starter, plug & socket for AC approved Make as per IS & IE rules.Inspection by-Consignee. | Numbers | 100.00 | 673.58 | 67,358 |
| 19 | Termination of LT XLPE cables of various sizes (One Job means all 4 cores of cables) | Job | 100.00 | 127.82 | 12,782 |
| 20 | Collecting, Transporting from SSE/PS/ store to site, laying, testing, and commissioning of above LT cable . Laying direct in ground (Including excavation, sand cushioning, protection brick covering and refilling the trench etc.), direct in RCC/Metal pipes in rod/track crossings and on surface/required in wall/in concrete floor by cutting recessed and finished originally as required as per relevant technical specifications. | Metre | 21300.00 | 69.84 | 14,87,592 |
| 21 | Supply and laying of B class, 50 mm dia, GI pipe of for cable riser/road crossing as required and as per relevant technical specification. Inspection by-Consignee. | Metre | 260.00 | 133.34 | 34,668.4 |
| 22 | Drilling of bituminous road/track and laying charges of cable in road crossing for laying 110 mm dia HDPE pipe through it. | Metre | 2000.00 | 301.91 | 6,03,820 |
| 23 | Excavation of cable duct by horizontal boring method 1.4 to 2.1 mtr depths from the bottom of sleeper for trench less track crossing and laying of 120 mm outer dia. DWC pipe. The work shall be done as per extent practice and instruction of site engineer. It includes supply of DWC/DHPE pipes conforming to IS : 14930 (Part 2, 2001). Inspection by-Consignee. | Metre | 200.00 | 1,027.65 | 2,05,530 |
| 24 | Supply and laying of HDPE Pipes (Upto PN 8.0 Pressure Rating Material Grade: PE 63, Pressure Rating: PN 8.0, Nominal Dia(mm): 110) as per IS-4984:2016 suitable for HT/LT XLPE cable & as required and as per relevant technical specification. Inspection by- RITES | Metre | 2200.00 | 271.71 | 5,97,762 |
| 25 | Supply, fixing, testing, connecting and commissioning of 300 mm sweep Exhaust Fan suitable for 230 volts, 50 Hz AC supply, 1440 RPM heavy duty with wiring and flexible PVC pipe as required.Inspection by- Consignee | Numbers | 42.00 | 1,443.84 | 60,641.28 |
| 26 | Provision of Geyser Points having MCB 16 A S/P with 3/5 pin 5/15 amps plug points with 1.5 sqmm (22/0.3mm) / 2.5 sqmm (36/0.3mm) PVC insulated single core unsheathed stranded Copper conductor ISI marked in recessed PVC pipe of ISI marked and MS switch box having wall thickness 16 SWG with 3 mm thick phenolic laminated sheet cover including providing and fixing 3/5 pin 5/15 Amps socket outlets and 5/15 Amps piano type switch and earthing the 3rd pin with 16 SWG Copper earth wire along with pipe duly clamped as required and as per relevant technical specification. ( 15 AMP) Inspection by- Consignee | Numbers | 36.00 | 456.86 | 16,446.96 |
| 27 | Supply of Musical Chime bell and erection on the installed MS board ,connection with twin core PVC insulated flexible copper conducor cable size 14/0.0076'' including testing and commissioning as per technical specification of approved make. Inspection by-Consignee. | Numbers | 20.00 | 47.94 | 958.8 |
| 28 | Supply, erection, connecting, testing and commissioning of cable terminatin cum distribution box made of 16 SWG MS Sheet as per relevant technical specification including providing earth terminal block for termination of 6 SWG GI earth wire and neutral block for termination of neutral conductors by screwed connections. Box should have locking arrangement with Allen key . Inspection by- Consignee. | Numbers | 20.00 | 381.29 | 7,625.8 |
| 29 | Supply, replacement, fixing, testing, connecting and commissioning of energy efficient luminaries complete with all accessries of capacity 18/20 watt, 4 feet length, T8 LED lamps with sutable current control potted driver circuit ,suitable for surface/recessed mounting.LED Luminaries:-(1) A complete LED lighting unit consisting of a light source and driver together with parts of distribute light,to position and protect the light source,and to connect the light source to a branch circuit.The light source itself may be an LED array and LED module, or an LED lamp. (2):-Supplied LED luminaries shall confirm to IS:16101(2012) IS :16106(2012) .Light Source (LED) in the Luminaries should be of make:- (1):-NICHIA/ CREE/OSRAM/ SEOUL/ PHILIPS/LUMILEDS /LEDNIUM. (2):-LEDs to IS: 16105(2012). IS:16108(2012), IEC:62471.1.Input operating voltage :-105-295 V AC. 2:-Normal Voltage- 220V AC.3.Driver type: constant current driver with short circuit protection(For tube light). 4.Control of distribution:-Full cut off. 5.Drive component :Industrial grade only .6.Efficiency of driver electronic: > 85% (For tube light).7.Colour temperature:5000-6500K(For tube light). 8.Colour rendering index(CRI):>75(For tube light). 9.Ingress protection :IP-20. 10.Lumen output: >100 lumens/[email protected] drive current(For tube light). 11.Power factor:->0.90(For tube light). 12.Total hormonics distrotion(THD):- <20% (For tube light). 13. Lamp cover :Acrylic cover which does not result in loss of lumens. 14. Finishing:Power coated /Anodized. 15.Secondry optics:poly corbonate reflector/ poly carbonate lens. 16. Construction of housing: extruded aluminum/CRCA/Pressure die cast aluminum. 17.Mounting :Suitable for surface mounting/recessed mounting. 18. Certificate: Firm to submit LM80(In respect of LED used) & LM79 (In respect of luminare used) test certificate from National/International accredited Laboratory and OEM certificate for complience of BIS/IEC. 19.Warranty:Firm to submit warranty certificate for five year along with the supply.All fittings shall be fitted as surface mounting/recessed mounting with twisted twin flexible cord of minimum size 16/0.2 mm copper conductor as per relevant technical specification. Materials praMtrs.s must remain unchanged during entire warranty period. 1x18/20 watt. Inspection by-Consignee. | Numbers | 260.00 | 342.59 | 89,073.4 |
| 30 | Supply and erection of 6 Mtr. Galvanized (as per BS EN ISO 1461) octagonal pole with base plate 220x220x12mm, top 70mm and bottom 130mm of 3mm thick sheet suitable for maximum wind speed upto 160 Km/Hr. including foundation bolts and foundation with M 20 grade RCC and FE 415 grade reinforcement (450x450x800 mm deep ) (foundation should be as per design approved by pole manufacturer) GI base plate G.I. anchor plate etc.as required including supplying and fixing of single arm hot dipped galvanized bracket suitable for street light fittings and supplying and drawing of 3x2.5 Sq.mm FRLS copper conductor single core cable from junction box with two Nos 6/10AMP MCB to luminaire complete including termination with copper lugs as required. Inspection by-RITES. | Numbers | 72.00 | 8,241.58 | 5,93,393.76 |
| 31 | Supply, fixing, testing, connecting and commissioning of 45 Watt or above LED street lights fittings.LED Luminaries:-(1) A complete LED lighting unit consisting of a light source and driver together with parts of distribute lights,to position and protect the light source,and to connect the light source to a branch circuit. The light source itself may be an LED array and LED module, or an LED lamp. (2):-Supplied LED luminaries shall confirm to IS:16101(2012) IS:16106(2012). Light Source(LED) in the Luminaries should be of make:- (1):- NICHIA/CREE/ OSRAM/ SEOUL/PHILIPS/LUMILEDS/LEDNIUM. (2):-LEDs to IS:16105(2012). IS:16108 (2012),IEC:62471.Type LED:- High power LED, SMD (Surface Mounting device) /COB ( Clip on board). 1.Input operating voltage :-105-295 V AC. 2:- Normal Voltage-220V AC, 3.Driver type: constant current driver with short circuit protection. 4.LED life:- >50000 burning hours.5.Depreciation:- 30% max.after 50000 burning hours. 6.Control of distribution:-Full cut off. 7.Surge protection:4KV. 8.Drive component :Industrial grade only. 9 .Efficiency of driver electronic: > 85%. 10.Beamangle:>=140 degree along with road and >=80 degree across the road. 11.Colour emperature: 5000- 6500K. 12.Colour rendering index ( CRI ) : >=75. 13. Ingress protection :IP-66. 14.Lumen output: >120 lumens/ watt. 15.Power factor:- >0.95. 16.Total hormonics distrotion(THD):- <15%. 17.Lamp cover : Toughened glass or UV stabilsed poly carbonate. 18.Finishing: Power coated/ Anodized. 19.Secondry optics:poly corbonate reflector/ poly carbonates lens. 20.Construction of housing: extruded aluminum/CRCA/Pressure die cast aluminum. 21.Mounting:Suitable for existing pole/Truss/Lantern mounted. 22.Certificate:Firm to submit LM80(In respect of LED used)& LM79(In respect of luminare used) test certificate from National/International accredited Laboratory and OEM certificate for compliance of BIS/IEC.23.Warranty:Firm to submit warranty certificate for five year along with the supply. All fittings shall be fitted with new suitable bend/elbow with clamp and proper nut and bolt and connection with twisted twin flexible cord of minimum size 16/1 mm copper conductor as per relevant technical specification. Materials parameters must remain unchanged during entire warranty period. Inspection by- Consignee. | Numbers | 52.00 | 2,024.73 | 1,05,285.96 |
| 32 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.Inspection by- Consignee. | Numbers | 126.00 | 2,414.04 | 3,04,169.04 |
| 33 | Supply, erection, testing and commissioning of One phase distribution board comprising of one no. 32/40 amps DP MCB with 40 A ELCB/RCCB as incoming and 4 nos. 10 amps SP MCB , 4 nos. 20 A SP MCB as outgoing complete with copper bus bars, neutral link and other accessories housed in CRCA sheet enclosure with double door type. Inspection by- Consignee. | Numbers | 20.00 | 3,644.95 | 72,899 |
| 34 | Supply, replacement, fixing, testing, connecting and commissioning of 72 Watt or above LED street lights fittings as per IS:10322. LED Luminaries:-(1) A complete LED lighting unit consisting of a light source and potted driver together with parts of distribute lights,to position and protect the light source,and to connect the light source to a branch circuit. The light source itself may be an LED array and LED module, or an LED lamp.(2):-Supplied LED luminaries shall confirm to IS:16101 (2012) IS :16106(2012). Light Source(LED) in the Luminaries should be of make:- (1):-NICHIA/ CREE/OSRAM/ SEOUL/ PHILIPS/LUMILEDS /LEDNIUM. (2):-LEDs to IS:16105(2012). IS:16108(2012), IEC:62471. Type LED:- High power LED,SMD(Surface Mounting device)/COB(Clip on board). 1.Input operating voltage :-105-295 V AC.2:- Normal Voltage- 220V AC,3.Driver type: constant current driver with short circuit protection. 4.LED life:- >50000 burning hours. 5.Depreciation:- 30% max.after 50000 burning hours.6.Control of distribution:-Full cut off. 7.Surge protection:4KV. 8.Drive component :Industrial grade only.9.Efficiency of driver electronic: > 85%. 10.Beam angle:>=140 degree along with road and >=80 degree across the road.11.Colour temperature: 5000-6500K. 12.Colour rendering index(CRI):>=75. 13.Ingress protection :IP-66.14.Lumen output: >120 lumens/watt.15.Power factor:->0.95. 16.Total harmonics distortion(THD):- <15%.17.Lamp cover :Toughened glass or UV stabilised poly carbonate. 18.Finishing:Power coated/Anodized. 19.Secondry optics:poly carbonate reflector/ poly carbonates lens. 20.Construction of housing: extruded aluminum/ CRCA/Pressure die cast aluminum. 21.Mounting :Suitable for existing pole/ Truss/ Lantern mounted. 22.Certificate:Firm to submit LM 80(In respect of LED used) & LM79 (In respect of luminare used) test certificate from National/ International accredited Laboratory and OEM certificate for compliance of BIS/IEC. 23.Warranty:Firm to submit warranty certificate for five year along with the supply. All fittings shall be fitted with new suitable bend/elbow with clamp and proper nut and bolt and connection with twisted twin flexible cord of minimum size 16/1 mm copper conductor as per relevant technical specification. Material parameters must remain unchanged during entire warranty period. Inspection by- Consignee. | Numbers | 132.00 | 2,358.13 | 3,11,273.16 |
| 35 | Supply, erection, testing and commissioning of single earth electrode of 50 mm. dia 4000mm long GI pipe class B complete with earth box with CI cover hinged to CI frame including connection from earth electrode to MDB/SDB/poles/with 8 swg GI wire/strip as per attached drawing.Inspection by- Consignee. | Numbers | 56.00 | 2,933.4 | 1,64,270.4 |
| 36 | Supply, fixing, testing and commissioning of wall mounted distribution board (TPN MCB - Incoming & SP MCB - Outgoing), made up of steel sheet, phosphatised power painted complete with neutral link, earth point,Din rail conforming to IS:13032 & 8623 with following items of matching make to be fixed in distribution board confirming to IS:8828 :1996 or latest, IE rules and site requirement. TPN MCB 63 Amps 10kA "C" series =01 Nos. (incoming) SP MCB 6-32Amps 10kA "C" series= 18 Nos.(outgoing). Inspection by-Consignee. | Numbers | 18.00 | 6,239.09 | 1,12,303.62 |
| 37 | Supply, erection, connecting, testing and commissioning of meter cum distribution box made of 16 SWG MS Sheet as per relevant technical specification including providing earth terminal block for termination of 6 SWG GI earth wire and neutral block for termination of neutral conductors by screwed connections. Box should have locking arrangement with Allen key with supply & providing MCB B/C series, 10 KA breaking capacity of approved make as per list attached etc. for incoming and outgoing of following capacity and nos. as required as per relevant technical specification including supply, fixing connecting and commissioning of single phase KWH meter of following capacity of approved make.......One No. Single-phase KWH meter 0-20 Amp capacity, one No. DP-MCB of 20 Amp. Cap. for incoming and 3 Nos. SP-MCB of 06 Amp. and 2 Nos. SP-MCB of 10 Amp cap. 1 No SP-MCB as spare of 06 Amp for outgoing with .......ELCB/RCCB 40 AMP Double Pole. Inspection by- Consignee. | Numbers | 16.00 | 4,206.52 | 67,304.32 |
| 38 | Design, Supply, fixing, testing and commissioning of double door feeder pillar panel (MCCB - Incoming & MCCB - Outgoing) comprising with the following MCCB's fixed in it of approved make conforming to IEC 60947-2 / IS 13947: 2008 & IS 8623:2008 or latest with digital measuring instrument & bus-bar arrangement and conforming to PCEE/NR's spec. No. PCEE/NR/126-Elect/PS/2019 at Tech Spec-VII attached or latest and as per IS, IE rules and site requirement. 4P MCCB 400 Amps 36 kA with adjustable thermal & fixed magnetic release = 01 Nos. (incoming) 4P MCCB 125 Amps 36 kA with adjustable thermal & fixed magnetic release = 04 Nos. (Outgoing). Inspection by-RITES. | Numbers | 4.00 | 1,29,585.63 | 5,18,342.52 |
| 39 | Supply & Fixing and commissioning of 25 Ltrs capacity of Stationary storage type electric water heater closed/vented type suitable for 240 Volts single phase AC 50 Hzsupply ISI marked to IS:2082/1993(reaffirm 2004). Copper inner container shall be of copper purity 90% minimum with impurities of zinc not exceeding 1%. Stainless steelinner container shall conform to material Outer container shall be made of MS sheet duly pretreated and finished in either White Stove enamel paint or powder coated in white color Storage electric water heater shall be complete in all respect with fittings asper general technical requirements. Inspection by- Consignee. | Numbers | 12.00 | 4,462.98 | 53,555.76 |
| 40 | Supply, fixing, testing and commissioning of wallmounted LT distribution board made up of steelsheet, phosphatised powder painted completewith neutral link,earth point, Din rail andprewired confirming to IS:13032 & 8623:1991with following items to be fixed in distributionboard, confirming to IS:8828 :1996 or latest, IErules and site requirement. 4P, MCCB 125 Amps.10 kA 'C' series= 01 No. (Incoming) DP RCCB (25,40 Amps., three nos. each) 10 kA 'C' series = 06Nos.(Outgoing). Inspection by- Consignee. | Numbers | 4.00 | 21,861.28 | 87,445.12 |
| 41 | D/S/F/T/C of LT panel/ feeder pillar comprising with the following MCCBs fixed in it of conforming to IEC 60947-2 / IS 13947:2008 or latest with digital measuring instrument & bus- bar arrangement confirming to IS 8623:2008 or latest and as per IS, IE rules and site requirement. 4P MCCB 200A 36kA with adjustable thermal & fixed magnetic release = 01 no. (Incoming) 4P MCCB 63A 36kA with adjustable thermal & fixed magnetic release = 04 no. (Outgoing).Inspection by- Consignee | Numbers | 2.00 | 65,300.7 | 1,30,601.4 |
| 42 | Supply, fixing, testing, connecting and commissioning of Outgoing/Feeder Panel Mounted Multi-function meter with Accuracy Class 1 as per IEC 62053-21 or Class 0.5, 0.5S, 0.2, 0.2S as per IEC 62053-22.LED meter Cl 1 with RS485: of similar model No.WL440521OOOO of L&T. Meter should have following features built-in LED • Flush mounting 96 x 96 mm • True RMS measurement • Password protection provision for security • Site selectable for 3 Phase 4 wire, 3 Phase 3 wire, 1 Phase, CT Secondary 1A/5A, Universal Auxiliary Supply 80-300 VAC/DC, Input Voltage Measurement 50-500 VAC, • 64 samples/ cycle The Meter should be able to read/display following parameters Instantaneous Parameters (V1, V2, V3, V12, V23, V31, Avg (VLN, VLL), A1, A2, A3, Aavg, F, PF-1, PF-2, PF-3, PF (Avg) W1, W2, W3, W (total) VA1, VA2, VA3, VA (total) Cumulative Parameters (Import Wh, Import Vah, Import load hours, Reset (old) Cumulative parameters (Import Wh, Import load hours, Communication (RS485 Modus RTU).complete with all accessories. Inspection by- Consignee | Numbers | 8.00 | 2,630.65 | 21,045.2 |
| 43 | Supply, installation and commissioning of Galvanised iron solar structure suitable for rooftop solar panel installation. Inspection by- Consignee. | Kg | 390.00 | 78.4 | 30,576 |
| 44 | Supply, installation and commissioning of Unarmoured Single Core 4 Sqmm tinned copper for DC cable supply. Inspection by- Consignee. | Metre | 130.00 | 27.44 | 3,567.2 |
| 45 | Supply, installation and commissioning of Connectors (male & female) pair MC4. Inspection by- Consignee. | Numbers | 26.00 | 35.83 | 931.58 |
| 46 | Supply, installation and commissioning of 4 sqmm single core copper flexible cable for interconnection. Inspection by- Consignee. | Metre | 130.00 | 24.83 | 3,227.9 |
| 47 | Supply, installation, testing and commissioning of Solar Invertor from 24 Volts DC to 230 Volts 50 Hz AC 1000 VA for above SPV module. Inspection by- Consignee. | Numbers | 13.00 | 13,066.5 | 1,69,864.5 |
| 48 | Wiring for light/fan/exhaust fan/call bell points with 1.5 sqmm (22/.3 mm) PVC insulated single core unsheathed stranded Copper conductor ISI marked cable in recessed PVC pipe of ISI mark, MS switch box having wall thickness 16 SWG with 3 mm thick phenolic laminated sheet cover including running of 16 SWG copper earth wire along with the pipe duly clamped as required and as per relevant technical specification No. Sr.DEE/G/ALD/IE/94/ 104/Rev and additional specification..... Medium Point | Numbers | 130.00 | 203.26 | 26,423.8 |
| 49 | Wiring for 3/5 pin, 5 Amp. Plug point with 1.5 sqmm (22/.3mm) PVC insulated single core unsheathed stranded Copper conductor ISI marked cable including providing and fixing 3/5 pin 5 Amps. Socket out let with switch on same board andearthing the 3rd pin with 16 SWG/(1.5sqmm PVC insulated single core unsheathed stranded Copper conductor) copper earth wire etc. as required and as per relevant technical specification. | Numbers | 26.00 | 54.72 | 1,422.72 |
| 50 | Supply, fixing, testing and commissioning of 250 mm sweep fresh air fan complete and conforming to approved specification.Inspection by- Consignee. | Numbers | 20.00 | 1,173.5 | 23,470 |
| 51 | Wiring for circuit with 2.5 sqmm (36/0.3mm) PVC insulated single core unsheathed stranded Copper conductor ISI marked cable in recessed PVC pipe of ISI marked and running of 16 SWG copper earth wire duly clamped with pipe and providing multiway connector on MS switch box for neutral looping etc. as required and as per relevant technical specification............ 2 x 2.5 sq mm | Metre | 1000.00 | 62.82 | 62,820 |
| 52 | Supply, Installation, Testing and Commissioning of tubular battery of capacity 12V, 150 AH, complying to JIS C8702/IEC 61056/IS 16220/ IS 16046/ IS 1651/UL(UL-1989) & CE certified with OEM warranty of minimum 36 months. Inspection by- Consignee. | Numbers | 26.00 | 13,500 | 3,51,000 |
| 53 | Supply, installation and commissioning of 520 Wp Solar PV module (Indian solar module) as per IEC 61215/IS 14286 standards. (1Number= 1 Wp). Inspection by- Consignee. | Numbers | 13520.00 | 25.26 | 3,41,515.2 |
| 54 | Supply, Erection, Testing and Commissioning of following Modular type step type Electronic Fan Regulator complete in all respect.Inspection by- Consignee. | Numbers | 100.00 | 223.79 | 22,379 |
| Schedule total | ₹89,36,653.1 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TNDoclatest.pdf
ATTACHMENT
GCC_April-2022_27_04_22.pdf
ATTACHMENT
GCCACS2022CORRECTION.pdf
ATTACHMENT
Likelysourceofsupply.pdf
ATTACHMENT
2022_12_13RBCE_CE-I-CTIndianRailwaysStandardGeneralConditionsofContractApril2022ACSNo_21.pdf
ATTACHMENT
2023_04_26RBCE_CE-I-CTIndianRailwaysStandardGeneralConditionsofContractApril-2022AdvanceCorrectionSlipNo_3ACS-31.pdf
ATTACHMENT
2023_08_07RBCE_CE-I-CTIndianRailwayStandardGeneralConditionsofContractApril-2022AdvanceCorrectionSlipNo_4ACS-4_1.pdf
ATTACHMENT
2023_10_20RBCE_CE-I-CTIndianRailwayStandardGeneralConditionsofContractApril-2022AdvanceCorrectionSlipNo_5ACS-5_1.pdf
ATTACHMENT
2023_12_21IndianRailwaysStandardGeneralConditionsofContractApril-2022AdvanceCorrectionSlipNo_6ACS-6_1.pdf
ATTACHMENT
2024_05_14ClarificationregardingsubmissionofAnnexure-VofGCC.pdf
ATTACHMENT
Annexure-VA.pdf
ATTACHMENT
AnnxVIB.pdf
ATTACHMENT
ACS_7to10.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .