| 1 | L1₹14.5 LAccepted-AOC FLAT NO 03 MALTI NIWAS AVADH VIHAR COLONY MANDAKNI BLOCK BEHIND RAILWAY STATION DISTRICT AYODHYA 224001 UP | AYODHYA | AYODHYA | UP | 224001 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹16.2 L+₹51,478.10 (3.29%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹17.2 L+₹1.5 L (9.61%)Rejected-Finance D 65 423 C 1 RANA NAGAR COLONY GATE NO 4 LAHARTARA VARANASI UP PIN 221106 | VARANASI | VARANASI | UTTAR PRADESH | 221106 | L3 | Rejected-Finance Not Being L1 |
Tender Value
₹15.8 L
EMD Value
₹31,700
Closing Date
28 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (MES) Faizabad
Garrison Engineer Military Engineer Services Faizabad
SPL REP TO BLDG NOs P-18 AND P-19 AT DRC AND PROVN OF 02X2 TON AC WITH VOLTAGE STABILIZER IN STN HQ UNDER GE FAIZABAD
2022_MES_560561_1
8335/E8
Open Tender
Civil Works
Item Rate
180 days
Faizabad
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (MES) Faizabad
₹31,700
Yes
8 Feb 2023
31 Oct 2022
30 Nov 2022
31 Oct 2022
28 Nov 2022
14 Nov 2022
Amount
Dismantling GI / AC (plain or corrugated or semi corrugated) sheets of any gauge, thickness in roof covering including ridges pf any description complete all as speciifed and directed.
Dismantling of wall & celling boards (fiber pulp insulation etc) or insulation boards / slabs/ blankets of any thickness including cover fillets and frame work complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Taking down chowkats or frames (without taking off shutters from the frames)n.exc 1.5 Sqm each complete all as specified and directed.
S&F mild steel in joist channel, angle or T section, fixed independently, without connecting plate etc (cut to ordinary length i.e, within 20mm of the length as indicated) conforming to Fe 410-W (Gde- E-250) Qty-A complete all as specified and directed.
S&F Rolled mild steel sections as in main & cross beams, hip & jack rafters, purlins where connected to common rafters and running rails & guides for sliding doors, fixed with angles cleats or other connecting plates conforming to Fe-410-W (Gde E-250) Quality A complete all as specified and directed.
S&F Pre-Painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F Pre-Painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specifiedand directed.
S&F mild stell work as in bands, straps, supports or stays for rain water pipes, ventilating pipes including bolts, if required, hooks (stay) for large gates, hook and pintle hinges, large hasps and staples, chains, hand made sliding bolts, clamps, hold fasts, will ties, hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Fe-290 (Gde-E-250) complete all as specified and directed.
M&L for preparation of new steel and iron surfaces of any description over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer over complete all as specified and directed.
S&F anodised aluminium snap grid frame work for false ceiling including hangers 6mm dia GI adjusting level fixed to roof slab by means of ceiling cleats made out of G.I. flat of size 40 X 3 mm, 60mm long and expansion hold fasterns 12.5mm dia, 40mm long complete all as specified and directed.
M&L for 12mm thick perforated particle boards / tiles of size 60x60cm for insulation and accoustic purposes, fixed to timber frame work with screws or with wire staples to snap grid complete all as specified and directed.
S&F aluminium window in lieu of wooden or steel window / ventilator, made out of extruded powder coated aluminium sections with sliding or openable shutters including frame and necessary jointing cleats, glazing clips, powder coated aluminium snap beading, screws etc complete and also including powder coated aluminium fittings such as cobra hinges, butt hinges, tower bolts, Star lock, hooks & eyes peg stays, rubber beading and handles including connected items with and including, making good for dismantling portion in PCC (1:2:4) or in cement mortar (1:3) complete all as specified and directed. Note :- (i) Minimum thickness of powder coating shall be 15 micron for windows and 25 microns for doors.
S&F aluminium anodised grill and frame of approved make and pattern of 10mm thick fixed for aluminium windows including 'F' section complete all as specified and directed.
S&F 4mm thick sheet glass of ordinary quality in squares n.exc 0.5 Sqm in each pane complete all as specified and directed.
Taking down cement plaster on brick walls including raking out joints, hacking for key, scrubbing down with water and preparing surfaces to receive new plaster and rubbish off the premises etc complete all as specified and directed.
M&L15 mm thick rendering in cement mortar (1:4) mixed with liquid water proofing compond @ 3% of cement wieght or as per manufactirer's instructions, on fair faces of brick work or concrete surfaces of walls, finished even and smooth without using extra cement Note: WPC shall be measured & paid for separately at supply only rates.
M&Lfor 10 mm thick rendering in cement mortar (1:6) on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed..
M&L for preparation of newly plastered or previously untreated surfaces of walls and applying two coats of oil bound distemper over a coat of 1mm thick wall care putty complete all as specified and directed. Note : Approval of GE/Engr-in-Charge shall be taken in token of satisfaction by the contractor before applying finishing work.
M&L for preparing newly plastered surfaces of walls and applying two coats of weather coat paint over a coat of alkali resistant primer complete all as specified and directed.
M&L for preparing old decorated surfaces of walls and applying two coats of weather coat complete all as specified and directed.
M&L for complete removal of existing decorative treatment of any description and applying two coats of oil bound distemper over a coat of 1mm thick wall care putty complete all as specified. Note : Approval of GE/Engr-in-Charge shall be taken in token of satisfaction by the contractor before applying finishing work.
M&L Non-skid Ceramic tiles 7 to 8 mm thick (square/ rectangular), area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, laid over and including 15mm thick screed bed or bedding layer in cement mortar (1:6) in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed.
M&L Glazed ceramic coloured tiles in vertical surface 300x200x 7 mm, laid over and including 10mm thick rendering coat in cement mortar (1:4) in vertical surfaces as in skirting, dado, set and jointed in neat cement slurry and pointed in white or colour cement to match with the shade of tiles complete all as specified and directed.
M&L for preparation of old wooden surfaces of any description, not other wise described, over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
Demolition of brick work or stone / boulder masonry built in cement mortar or cement lime mortar including all quins, arches , pillars but excluding ashlar facing and pre-cast concrete articles complete all as specified and as directed.
M&L for brick work with old size sub class 'B' bricks in cement mortar (1:6), straight or curved on plan exc 6 m mean radius complete all as specified.
Supply only intergal water proofing compound of approved quality ISI marked all as specified and directed.
M&L 75 mm PCC (1:3:6) type C2 (using 40 mm graded crushed stone aggregate) as in plinth protection, laid in panels complete all as specified and directed.
M&L for PCC (1:4:8) type D-2 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified.
M&L for PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) as in surface channel and drain complete all as specified.
M&L for extra for forming fair finishing to drain or channel 30 cm inner girth in cement concrete using extra cement including forms, moulds etc, complete all as specified and directed. Note:- Inner girth only shall be measured.
All as per Srl item No. 32.00 above but add or deduct for each 25mm girth or part thereof over or under 30cm girth.
M&L for 15mm thick rendering in cement mortar (1:6) mixed with water proofing compound @ 3% by weight of cement or as per manufacturer's instructions on fair faces of brick work or concrete surfaces, finished even & smooth without using extra cement complete all as specified and directed. Note: WPC shall be measured & paid for separately at supply only rates.
M&L for PCC (1:2:4) type B1 (using 20mm graded stone aggregate) as in cills, copings, steps, seismic and other similar bands, plinth course, string courses, lacing courses, parapet and railing up to 60cm in height, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angle and throating and form work etc complete all as specified and directed.
Taking down carefully copper / aluminium point wiring (light, fan, call bell, two way, socket or power etc) with fitting of any description and M&L for concealed type point wiring with PVC insulated PVC unsheathed electric FRLS cable of size 1.5 Sqmm nominal cross sectional area, 1100 Volt grade, single core having multi stranded copper conductor with 1.5 Sqmm green colour PVC insulated unsheathed electric FRLS cable having multistranded copper conductor as earth wire connected to earth dolly by providing lugs including non-modular type PVC sunken box with 3mm thick hylam sheet with glossy finish including necessary cutting for fixing switches, sockets, regulators etc, drawn through and including non metallic rigid PVC conduit (ISI marked) medium grade not less than 20mm dia with all conduit accessories in concealed wiring system including cutting chases in wall and making good in cement mortar (1:4) with all necessary surface finishes such as white / colour wash / distempering etc to match the existing surfaces complete all as specified for the following:-
One light point or fan point controlled by one, one way switch
One 3 pin socket outlet 5 Amps on the same board with other switches
One 3 pin socket outlet 5 Amps socket outlet on independent board below the switch board of light point in the same vertical plane.
Taking down carefully copper / aluminium point wiring (light, fan, call bell, two way, socket or power etc) with fitting of any description and M&L for concealed type power point wiring with PVC insulated PVC unsheathed electric FRLS cable of size 2.5 Sqmm nominal cross sectional area, 1100 Volt grade, single core having multi stranded copper conductor with 2.5 Sqmm green colour PVC insulated unsheathed electric FRLS cable having multistranded copper conductor as earth wire connected to earth dolly by providing lugs including non-modular type PVC sunken box with 3mm thick hylam sheet with glossy finish including necessary cutting for fixing switches, sockets, regulators etc, drawn through and including non metallic rigid PVC conduit (ISI marked) medium grade not less than 20mm dia with all conduit accessories in concealed wiring system including cutting chases in wall and making good in cement mortar (1:4) with all necessary surface finishes such as white / colour wash / distempering etc to match the existing surfaces complete all as specified for the following:-
S&F switch piano flush type polycarbonate single pole one way 6 Amps complete all as specified and directed.
S&F switch piano flush type polycarbonate single pole one way 16 Amps complete all as specified and directed.
S&F socket outlet polycarbonate 2 in 1, 5 pin 6 Amps flush type complete all as specified and directed.
S&F socket outlet polycarbonate 2 in 1, 5 pin 6/16 Amps flush type complete all as specified and directed.
M&L for ceiling rose in polycarbonate 3 terminal brass flush type 6 Amps, 250 Volts, AC supply (ISI marked), fixed on & including 3 mm thick 75mm dia sunmica hylum plastic laminated round sheet complete all as specified and directed.
S&F electronic fan regulator 230 Volts, stepped type (5 steps) socket type, hum free 100/300 watt, complete all as specified and directed.
Taking down existing submain wiring of any description and M&L for sub main wiring with two runs of 6.00 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 Volts grade multistranded copper conductor single core cable drawn through and including PVC concealed conduit of adequates size and fittings and accessories concealed in walls, floors and ceilings complete including one run of FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 6.0 Sqmm green in colour as earth continuity conductor connected to common earth dolly from main DB to Sub DB including cutting chases and making good in cement mortar (1:4) with all necessary surface finishes such as white / colour wash / distempering etc to match the existing surfaces complete all as specified. Note:- (i) Two runs of cable, one run of earth wire and one run of PVC non metallic conduit shall be measured as one run length. (ii) Cable required for connection to DBs and MCBs shall be deemed included in quoted rates. (iii) Earth wire shall run inside the conduit pipe.
Taking down existing unserviceable main switch, DB’s insulators, DB for MCB and board etc of any type and capacity and further disposal including making good the disturbed surfaces to match existing surfaces including wash wash, colour wash, distemper etc wherever required complete all as specified and as directed.
S&F epoxy powder coated MCB distribution box double door TPN 4 way horizontal type for MCBs alonwith provn of MCB as incomer with common bus-bar at incoming end of outgoing MCBs grouted / flush to wall including necessary cutting and making good disturbed surfaces in cement mortar (1:4) and applying white/colour wash / paint / distemper as required to match the existing surfaces complete all as specified and directed. Note: - MCBs shall be measured and paid for separately under respective item of Schedule 'A'.
S&F MCB, TPN,100 A, 415V, 10kA, 'C' curve miniature circuit breaker (MCB), fixed in DB including necessary connection, testing and commissioning, complete all as specified.
S&F epoxy powder coated MCB distribution box double door SPN 8 way for MCBs alonwith provn of MCB as incomer with common bus-bar at incoming end of outgoing MCBs grouted / flush to wall including necessary cutting and making good disturbed surfaces in cement mortar (1:4) and applying white/colour wash / paint / distemper as required to match the existing surfaces complete all as specified and directed. Note: - MCBs shall be measured and paid for separately under respective item of Schedule 'A'.
S&F MCB SP, 40 A, 240 V, 'C' curve, 10 kA, miniature circuit breaker (MCB), fixed in DB including necessary connection, testing and commissioning, complete all as specified.
S&F MCB SP, 6 to 32 A, 240 V, 'C' curve, 10 kA, miniature circuit breaker (MCB), fixed in DB including necessary connection, testing and commissioning, complete all as specified.
Taking down existing light fitting of any description and S&F new indoor luminare batten for wall / ceiling mounting box type energy efficient saving LED BATTEN LIGHT 20 W including twin core twisted flexible copper conductor wire from ceiling rose to connector all as specified and directed.
S&F in replacement, angle holder (metal ring) PVC / polycarbonate type with back plate, fixed on & including 3 mm thick 75mm dia sunmica hylum plastic laminated round sheet suitable for LED bulb complete all as specified and directed.
Taking down existing light fitting of any description and S&F new LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP 65/66 protection complete all as specified and directed.
S&F 40mm dia bore GI tubes, mediumt grade, with all fittings and fixed to walls and ceilings or laid in floors complete all as specified and directed.
Taking down existing earthing of any description and M&L for new earthing complete with galvanized steel plate electrode 600 mm x 600 mm x 6 mm thick, burried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 meter below normal ground level surrounded with mixture of charcoal and common salt in alternate layers from all sides and electrode connected to GI wire of 4mm dia by means of GI bolts, nuts, check nuts and washers, earthing wire protected by GI pipe 20 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate No. 3 of SSR-2009 Part I including all necessary excavation and earth work in any type of soil, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6) type C1 in concrete chamber of size not less than 300x300x300mm (internal diamentions) with cover made of precast cement concrete (1:2:4) type B-1 (using 20mm grded stone aggregate) complete all as specified and directed by Engineer-in-Charge. Note: (i) The chamber shall be constructed at 1.00 meter away from outer edge of earthing pit. (ii) The unit rate includes earthing wire and protection pipe upto maximum 7.50 meter from earth plate, earth point / test point.
Taking down ACSR Conductor of any type and size complete all as specified and directed.
Excavation in trenches, not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for foundation of poles, stays or for taking out / laying of cables and getting out in soft/loose soil complete all as specified and directed by Engr-in-Charge.
Supply, laying and testing 35 Sqmm 2 Core Cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor complete all as specified and directed.
Supply and laying river sand for cushioning of cables with layers of sand 8 cm before lying of cable and 15 cm after lying of cable (total 23 cm) in trenches complete all as specified and directed. Note: Thickness of sand cushioning shall be measured as 18cm after punning for payment purpose.
Supply & Laying of sub class 'B' bricks locally available best quality laid flat (length of bricks laid across the length of cable) in tranches for protection of U/G cable complete all as specified and directed by Engr-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm in soft/loose soilcomplete all as specified and directed by Engr-in-Charge.
Removing excavated materials (soil) at a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed by Engr-in-Charge.
Supply and Install inverter series Split type AC of capacity 2.0 Ton with cordless remote control unit 5 star rating with copper condenser coil and connecting pipe and cable not less than 3.0 mtr connected to existing electrical point all as specified and directed.
S&F Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA complete all as specified and directed.
M&L for sub main wiring with two runs of 6.00 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 Volts grade multistranded copper conductor single core cable drawn through and including PVC concealed conduit of adequates size and fittings and accessories concealed in walls, floors and ceilings complete including one run of FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 6.0 Sqmm green in colour as earth continuity conductor connected to common earth dolly from main DB to Sub DB including cutting chases and making good in cement mortar (1:4) with all necessary surface finishes such as white / colour wash / distempering etc to match the existing surfaces complete all as specified. Note:- (i) Two runs of cable, one run of earth wire and one run of PVC non metallic conduit shall be measured as one run length. (ii) Cable required for connection to DBs and MCBs shall be deemed included in quoted rates. (iii) Earth wire shall run inside the conduit pipe.
S&F single pole and neutral enclouser with a two pin and earth plug and socket with one single pole MCB 20 Amps , 240 Volts complete all as specified and directed.
Saket Traders
R K BROTHERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .