Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.9 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹5.7 L+₹74,376.12 (14.9%)Rejected-Finance | L2 | Rejected-Finance Not Admitted | |
| 3 | L3₹6.0 L+₹97,106.39 (19.5%)Rejected-Finance 93 4 16A BLOCK NO 3 JAWAHAR CHOWK PACHMARHI MP 461881 | PACHMARHI | HOSHANGABAD | MADHYA PRADESH | 461881 | L3 | Rejected-Finance Not Admitted | |
| 4 | Rejected-Technical | - | Rejected-Technical Not Admitted |
Tender Value
Refer Docs
EMD Value
₹16,800
Closing Date
10 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE Indpt Pachmarhi
AGE Indpt Pachmarhi,Dist. - Hoshangabad(MP)-461881
SPL REPAIR TO BLDG NO P-91 AT AEC TRG COLLEGE AND CENTRE PACHMARHI AND CERTAIN MINOR WORKS AT MH PACHMARHI.
2020_MES_376753_1
CA No. AGE(I)/PACH/ OF 2020-21 (8356/E8)
Open Tender
Civil Works
Item Rate
180 days
Pachmarhi MP
Class E category a(i)
8 documents required · 8 mandatory
₹500
AGE Indpt Pachmarhi
₹16,800
Yes
23 Dec 2020
11 Sept 2020
13 Oct 2020
11 Sept 2020
10 Oct 2020
26 Sept 2020
60 days
Amount
Taking down cement plaster on wall/ceiling/roof etc including raking out joints, hacking for key scrubbing down with water etc complete all as specified and as directed.
M&L 15 mm thick rendering on fair faces of bk /concrete surfaces in CM (1:6), finished even and smooth (without using extra cement ) complete all as specified and as directed.
M&L for rendering 15 mm thick in cement mortar 1:4, in two layers (1st layer 10 mm thick rendering coat and 2nd layer 5 mm thick finishing coat) on brick work or concrete surfaces, second layer (finishing coat) mixed with liquid water proofing compound @ 200 ml / 50 Kg bag of cement as per manufacturer's instructions and finished the surfaces even and fair without using extra cement complete all as specified and as directed. Note : Liquid WPC will be measured and paid separately.
M&L preparation of new plastered or unplastered surfaces of wall and applying two coats of cement based paint over a coat of primer complete all as specified and directed.
M&L for preparation of new surface of wall and applying two coat of white wash complete all as specified and as directed.
Supply only water proofing compound (liquid), ISI marked complete all as specified and as directed.
Complete removal of existing treatment and preparation of old decorated surface of wall and applyng three coat of white wash complete all as specified and as directed.
Complete removal of existing treatment and preparation of old decorated surface of wall and applyng two coat cement base paint complete all as specified and as directed.
Removing old paints by paint removers or burning off by blow lamps and cleaning with scrapers, any number of coats,any width or girth complete all as specified and as directed.
M&L Preparing old wooden surfaces exceeding 10Cm in width or girth and applying two coats of synthetic enamel paint over a coat of primer complete all as specified and as directed.
M&L Preparing old steel surfaces exceeding 10Cm in width or girth and applying two coats of synthetic enamel paint over a coat of primer complete all as specified and as directed.
Dismantling boarding, anydescription, fixed in any positionwith nails complete all as specified and as directed.
S&F suspended false ceiling grid system using chicago metallic (E Grid) exposed suspended system, grid size 600 x 600 mm and 4 mm thick comprising of GI powder coated main runner 39 x 24 x 0.8 mm (Thickness comprising of GI/0.4mm + PPPCGS/0.3mm and min weight of runner 1.35 Kg for 3600mm length), cross tee 29 x 24 x 0.80mm and wall angle 22.2 x 22.2 x 0.65 mm thick (Thickness comprising of GI/0.35mm + PPPCGS/0.3mm and min weight of angle 0.7 Kg for 3050mm length) with and including 4mm thick HPSC (High Pressure Steam Cured) pre-primed, self embosed, textured design board, water resistant, termite resistant, fire resistant for insulation and acoustic purpose to be placed in grid system duly suspended with @ 1.2m c/c both way with 4 mm dia GI wire hangar fixed with steel dash fasteners or from purlin of roof with butterfly clips (wt 0.007kg), hold down clips (wt 0.0035kg) etc complete, ( main runner / cross tee /wall angle of Galvanised Iron powder coated), as per manufacturere instruction complete all as specified and directed. Note : Cost of making frame work and board (cut out) for fixing light fitting grill diffuser etc shall be deemed included in the quoted rate..Make Armstrong or equevalent
Dismantling timber scantlings as in framed work 40 sq. cm and over in section, in any position complete all as specified and as directed.
Dismantling timber scantlings as in framed work 40 sq. cm and under in section, in any position complete all as specified and as directed.
S&F rolled section for structural steel work as in main and cross beams, hip and jack rafters, purlin where connected to common rafters and running rails and guides for sliding crane, fixed with angle cleats or other connecting plates/ bolts, conforming to Fe-290(Gde-E-165) complete all as specified and as directed. Note : The rates quoted allow for cutting to dead length where required, notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting angle cleats, fish plates, gusset plates etc., also for wedging, plumbing, truing up and fixing complete all as specified and as directed.
S&F MS work of ISA , band & strap,Channels plates etc of any description and thickness including cutting required size welding if required and fixing in wall , floor and similar work conforming to Fe 290. Gde -E-165 etc complete all as specified and as directed.
M&L preparation of new steel surface and applying two coats of synthetic enameled paint over a primming coat of red oxide etc complete all as specified and as directed.
Dismantling Single layer Mangalore pattern or similar tiles in roofing complete all as specified and as directed.
M&L Pre- painted galvatumealuminum zinc coating GI based corrugated steelsheet 0.50mm thick of ancolour having tensilestrength of 550 Mpa as in roof covering/ cladding towall, fixed with self tap ping screws complete all as specified and as directed.
M&L Pre- painted galvatumealuminum zinc coating GI based plain steel sheet 0.50mm thick of ancolour having tensilestrength of 550 Mpa as in roof ridge/ cladding towall, fixed with self tap ping screws complete all as specified and as directed.
Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed.
M&L Cement concrete 75mm thick type C-2 (1:3:6) using 40mm graded stone aggregate as in plinth protection complete all as specified and as directed.
M&L Cement concrete 40mm thick type B0 (1:2:4) using 12.5mm graded stone aggregate as in floor finished with with fair finished concrete surface even and smooth with using extra cement complete all as specified and as directed.
Providing, cement concrete type B0 1:2:4 using 12.5 mm graded stone aggregate as in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and as directed.
Surface excavation n exc 30cm deep and averaging 15 cm deep and getting out soft/loose soil complete all as specified and as directed.
Hardcore of brocken stone or boulder gauge n exc 63mm, deposited, sprade and levelled in layers n exc 15cm thick watered and rammed to true surface complete all as specified and as directed.
M&L100 mm thick PCC 1:4:8(40 mm graded stone aggregate ) type D-2 as in floors using necessary form works complete all as specified and as directed.
M&L for Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry with grey cement and no pigment in floors including 15mm thick screed bed in CM 1:6 complete all as specified and as directed.
M&L for providing cement concrete coping/window cill/ rounded or chamfered on edge in concrete mix 1:2:4 using 20 mm stone aggregate complete all as specified and as directed.
Excavating in trenches, n exc1.5 m wide and n exc 1.5 m indepth; for foundation, etc. orfor shafts, wells, cesspits,manholes, pier holes, etc. nexc 10 sq m on plan and n exc1.5 m in depth and getting out complete all as specified and as directed.
Removing excavated soil n.exc 50 m and depositing where directed at a level n.exc1.5m above the starting points complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in loose/soft soil complete all as specified and as directed.
Providing, cement concrete type D2, 1:4:8 using 40 mm graded stone aggregate as foundaton filling and mass concrete complete all as specified and as directed..
M&L modular brick work sub class B bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and as directed.
M&L damp proof course to horizontal or vertical surfaces including necessary formwork complete all as specified and as directed.
M&L moorum/red bajri filling in floors orpavings, laid in layers n exc. 15 cmthick, spread, levelled and rammedincluding watering complete all as specified and as directed.
Use and waste of formwork to flat and rough finished formwork to soffit of suspended slabs such as roof slab floor slab and similar work including edges complete all as specified and as directed.
Use and waste of formwork to flat and rough finished formwork to side and soffit of floor or roof beam , lintels and similar work including edges complete all as specified and as directed.
Use and waste of formwork to flat and rough finished edge of concrete flats, window cilland side of RCC/PCC bands and simmilar work exc 10 cm and n exc 20 cm wide complete all as specified and as directed..
TMT reinforcement bars 10mm over dia including all cutting bending binding cranking placing & binding with MS wire (annealed) not less than 0.90mm dia complete all as specified and as directed.
Discription same as per item no 41 but 6mm to 8mm dia as in stirups complete all as specified and as directed.
M&L for RCC(nominal mix) type B1 using 20mm graded stone aggregate) in fplinth beam, foundation beam,base for column and similar work complete all as specified and as directed.
M&L for RCC(nominal mix) type B1 using 20mm graded stone aggregate) in beamsand similar articles complete all as specified and as directed.
M&L Water proofing treatment on "Non approachable / non accessible and approachable roof" surface (Horizontal & Vertical surfaces) in following sequence through manufacturer / authorized applicator of the manufacturer including taking down of existing roof treatment, properly cleaning & drying the concrete surfaces complete
(ii) Applying a coat of oxidised bitumen based solvent primer @ 0.3 Kg / Sqm
(ii) Applying a coat of oxidised bitumen based solvent primer @ 0.3 Kg / Sqm
(iv) Laying unrolled over the bitumen coated surface, polymeric water proofing membrane Hyperplas standard wt not less than 3kg /Sqm with 100 mm over laps shall be sealed by flame as per manufacturers instruction.
(iv) Applying two coats of bituminous base aluminium paint including preparation complete
M & L preparation of newly plastered surfaces of wall & applying three coats of white wash complete all as specified and as directed.
M & L preparation of newly plastered surfaces & applying two coats of white wash on ceiling surface complete all as specified and as directed.
Material and labour for point wring One light/fan/exhaust fan point/call bell point controlled by 1 No,one way 5/6 Amp switch.,using approved colour coding (Phase-red,Neutral-black,Earth-green) complete with FRLS PVC insulated and unshealthed stranded copper conductor cable 1.5 sqmm single core conforming to IS 694 including medium duty concealed unplasticised PVC conduit conforming to IS 9537(part-3) and ISI marked not less than 20 mm dia with concealed in wall pressed steel terminal box of not less than 2 mm thick of required size including painting terminal boxes inside and outside with two coat of synthetic enamle paint over one coat of red oxide primer with top cover 3 mm thick bakelite laminated sheet with brass screws and Cup washer with all assessories including FRLS PVC insulated and unshealthed stranded copper conductor cable 1.5 sqmm single core in green colour as earth wire connected to earth dolly complete all as specified and directed. Make of wire:- Havells/Plaza/Finolex
Description same as per iten no. 52 for One 3 pin /5 pin socket outlet 5 Amp controlled by 1 No one way 5/6 Amp switch on same board along with other switches ,fan regulator etc. complete all as specified and as directed..
Description same as per iten no. 52 One 3 pin /5 pin socket outlet 5 Amp controlled by 1 No one way 5/6 Amp switch on independent board complete all as specified and as directed..
S&F switch piano flush button single pole one way 6 Amp, 240 Volts conforming to IS 3854 ISI marked Make: ANCHOR/HAVELLS/PLAZA
S&F for socket outlet, 5 Pin, 6 Amp flush type conforming to IS 1293 ISI marked complete all as specified and as directed.. Make: ANCHOR/HAVELLS/PLAZA
S & F ceiling rose, surface Bakelite,isolated body three terminals complete all as specified and as directed.. Make: ANCHOR/HAVELLS/PLAZA
S&F Electronic fan regulator steped type (flush type) 240 volt ,50Hz ,single phase on existing phenotic laminated sheet including taking down old one and connecting complete all as specified and directed. Make: ANCHOR/HAVELLS/PLAZA
Material and labour for point wring ,using approved colour coding (Phase-red,Neutral-black,Earth-green) complete for one socket outlet 15 Amp on independent board with FRLS PVC insulated and unshealthed stranded copper conductor cable 2.5 sqmm single core conforming to IS 694 including medium duty concealed unplasticised PVC conduit conforming to IS 9537(part-3) and ISI marked not less than 20 mm dia with concealed in wall pressed steel terminal box of not less than 2 mm thick of required size including painting terminal boxs inside and outside with two coat of synthetic enamle paint over one coat of red oxide primer with top cover 3 mm thick bakelight laminated sheet with brass screws and Cup washer with all assessories including FRLS PVC insulated and unshealthed stranded copper conductor cable 2.5 sqmm single core in green colour as earth wire connected to earth dolly complete all as specified and directed . Make: Havells/Plaza/Finolex
S&F switch piano flush button single pole one way 15 Amp, 240 Volts conforming to IS 3854 ISI marked complete all as specified and as directed.. Make: ANCHOR/HAVELLS/PLAZA
S&F for socket outlet, 5 Pin, 5 & 15 Amp flush type conforming to IS 1293 ISI marked complete all as specified and as directed.. Make: ANCHOR/HAVELLS/PLAZA
S&F sheet metal enclosures (MCB Distribution board) when MCB’s to be used single pole and neutral 8 ways 415 volt with 200 amps rated bus bar, double door with bus bar neutral link earth bar, Din rail, necessary blanking plated, including fixing DB flush in wall complete with making good disturbed surfaces as per existing complete all as specified and as directed.. Make - Legrand/HAGER/L &T
S & F sub main wiring using approved colour coding (Phase-red,Neutral-black,Earth-green) complete with two single core FRLS PVC insulated and unshealthed stranded copper conductor cable 4 sqmm as current carrying conductor and one run of 4.0 sqmm as earth contunity conductor ,voltage rating 1100 volt ,ISI marked drawn in and including concealed PVC conduit ISI marked of dia not less than 25 mm and thickness 2 mm with stranded accessories along with one run of FRLS PVC green colour insulated,unshealthed,stranded copper conductor of size 4 sqmm including taking down old one complete all as specified and as directed.. Make of wire:Havells/Plaza/Finolex Note: Two run of single core FRLS PVC cable with one run of earth contunity conductor and conduit shall be measured as one unit.
11. S&F MCB’s single pole, 10 KA ,6 Amp to 30 Amp 240 Volts,and of ''C'' series with required wiring connections and lugs etc and erecting in provided enclouser/destribution board.MCBs shall be of current limiting type ,ISI marked conforming to IS 8828-1996.the power loss per pole shall be low and shall be in accordance with IS 8828-1996,All cable entries shall be either from bottom or top .MCB shall be of C curve charactertics & shall have quick make and break non welding self wiping silver alloy contact for 10 KA short circuit both on manual & automatic operation .All the active ,live parts of MCBs should be out of human reach ,ensuring safty & conforming to IP 55 degree of protection .The MCBs must house transperent lebel holder to ensure circuit identification .The MCB must have fully insulated safty shutters.The MCB shall have lockable switching lever.The minimum electrical endureance shall be 20000 operations .The housing of MCB shall be mounted self-extinguishing DMC(Dough moulding compount).The short circuit current shall be brought zero within 4 t0 5 milliseconds from the time they are established complete all as specified and as directed.. Make:LEGRAND /L & T/SCHNEIDER
S&F MCB’s single pole and neutal, 10 KA ,32 Amp to 40 Amp 240 Volts,and of ''C'' series with required wiring connections and lugs etc and erecting in provided enclouser/destribution board.MCBs shall be of current limiting type ,ISI marked conforming to IS 8828-1996.the power loss per pole shall be low and shall be in accordance with IS 8828-1996,All cable entries shall be either from bottom or top .MCB shall be of C curve charactertics & shall have quick make and break non welding self wiping silver alloy contact for 10 KA short circuit both on manual & automatic operation .All the active ,live parts of MCBs should be out of human reach ,ensuring safty & conforming to IP 55 degree of protection .The MCBs must house transperent lebel holder to ensure circuit identification .The MCB must have fully insulated safty shutters.The MCB shall have lockable switching lever.The minimum electrical endureance shall be 20000 operations .The housing of MCB shall be mounted self-extinguishing DMC(Dough moulding compount).The short circuit current shall be brought zero within 4 t0 5 milliseconds from the time they are established complete all as directed. Make:LEGRAND /L & T/SCHNEIDER
S&F LED Recessed open 2x2 tile glare free uniform illumination with longer life and less maintenence complete light fitting suitable for 600x600 mm ceiling and testing complete including replacement of existing fitting complete all as specified and direcetd. Make: CG Cat Pat No. LCTLRN-36-FO-CDL or equivelent make and model of BAJAJ/PHILLIPS
GHASI RAM SAHU
DEEPAK JAISWAL
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .