Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.0 LAccepted-AOC | L1 | Accepted-AOC Reasonable | |
| 2 | L2₹17.9 L+₹2.2 L (13.8%)Rejected-Finance | L2 | Rejected-Finance High Rate | |
| 3 | L3₹21.4 L+₹5.7 L (36.6%)Rejected-Finance FLAT NO 10 S NO 98 PLAT NO 78 SAI SAYAJI PARK A RIGHT BHUSARI COLONY KOTHRUD PUNE 411 038 | PUNE | MAHARASHTRA | 411038 | L3 | Rejected-Finance High Rate | |
| 4 | L4₹21.9 L+₹6.2 L (39.3%)Rejected-Finance | L4 | Rejected-Finance High Rate | |
| 5 | L5₹23.7 L+₹8.0 L (51.0%)Rejected-Finance 16 B DR AMBEDKAR ROAD SAROSH APARTMENTS PUNE 411001 | PUNE | MAHARASHTRA | 411001 | L5 | Rejected-Finance High Rate |
Tender Value
Refer Docs
EMD Value
₹58,600
Closing Date
10 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NDA KHADKWASLA
GE NDA KHADKWASLA
REPAIRS TO SEWAGE LINE AND OTHER MISC WK IN ZONE B AREA AT NDA KHADAKWASLA
2021_MES_412999_1
GE (K) 50 OF 2020-2021
Open Tender
Civil Works
Item Rate
330 days
GE NDA KHADKWASLA
AS TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
Yes
GE NDA KHADKWASLA
₹58,600
Yes
16 Mar 2021
15 Jan 2021
12 Feb 2021
16 Jan 2021
10 Feb 2021
27 Jan 2021
18 Jan 2021 - 25 Jan 2021
60 days
Amount
Attending to blockage of WHB, WC, sinks, urinals, floor, Nahani traps, gully trap, vertical CI pipe/PVC pipes of any dia (upto double story bldg),Taking out (desludge) silt brick bats, debris,liquid waste sludge in solid semi-solid state from manhloles incl pumping the flow in the drain if necessary plugging, diverting the flow in the drain if necessary and stacking the removed slit away from the edges of manholes as directed incl use of safety belts dry cell tourch for lighting inside the manholes and taking precautionarty measure and removing the sludge to a distance exceeding 50m and not exceeding 250m and leaving the manhloles cleaned and flushed with water etc incl taking out and refixing the manholes covers etc in any depth and Removing of blockage in sewage lines in any length and systematically cleaning the same using necessary tools, mechanically and /or manually such as passing rope knots, bamboo kasui and disc of required size by one safaiwala and one helper per day including Sunday & holiday i.e from 0900 hrs to 1700 hrs all as specified and directed.
Ditto all as per item No 1 above but one helper alongwith safaiwala
Taking out (desilting) silt brick bats, debris,liquid waste sludge in solid semi-solid state from septic tanks using mechanical means and stacking the removed slit away from the edges of tank as directed and removing the sludge to a distance exceeding 1.0 Km and leaving the septic tanks cleaned and flushed with water etc including taking out and refixing the septic tank covers etc.
Excavation in trenches n.exc 1.5m deep & n.exc1.5m wide for foundaton etc.in any type of soil and getting out.
Demolition of cement concrete in ground floors and paving n. exe 15cm thick below or above GL all as directed & cleaning premises.
Demolition of brick work or stone / boulder masonry built in cement mortar or cement lime mortar incl arches, pillers etc..
Demolition and breacking up 150 mm bore drain pipes (SWG,AC or RCC pipes) set in CM
Demolition and breacking up 200 mm bore drain pipes (SWG,AC or RCC pipes) set in CM
Demolition and breacking up 300 mm bore drain pipes (SWG,AC or RCC pipes) set in CM
M&L for providing plain cement concrete (1:4:8) type D2 (Using 40mm grade aggregate) as in foundation filling and mass concrete
M&L for precast cement concrete block walling exc. 10 cm width with solid block C-5 grade design mix and setting in cement mortar (1:6) all as specified and as directed
M&L for rendering 15mm thick on other than fair faces & brick or concrete surfaces in CM (1:4) finishing even without using exta cement
Cutting into existing manholes for connecting new drains internal dia of pipe 150mm making good to pipe & to or finished and reforming benching as required. 3/4 section in cement concrete (1:2:4) type B-1, smoothcutting out existing benching for forming branch channel (1/2) rendering
Cutting into existing manholes for connecting new drains internal dia of pipe 200mm making good to pipe & to or finished and reforming benching as required. 3/4 section in cement concrete (1:2:4) type B-1, smoothcutting out existing benching for forming branch channel (1/2) rendering
Extra for forming fair finished drain or channel girth not exc 30cm in cement concrete using extra cement including form mounds etc all as specified.
M&L for provided reinforced cement concrete pipe 150mm bore class NP-2 with collars laid and jointed with cement complete all as directed and specifed
M&L for provided reinforced cement concrete pipe 200mm bore class NP-2 with collars laid and jointed with cement complete all as directed and specifed
M&L for provided reinforced cement concrete pipe 300mm bore class NP-2 with collars laid and jointed with cement complete all as directed and specifed
M & L for providing bed to drain pipes 150 mm dia in cement concrete (1:3:6) type C2 using 400 mm stone aggregate including packing under and haunching against the sides of pipe after they are laid & tested
Ditto all as per item No19 above but for 200 mm dia pipes
Ditto all as per item No 19 above but for 300 mm dia pipes
Returning filling in soil including spreading levelling, watering & well ramming in layers n. exe 25cm (Soft /disintregated rock)
Removing excavated material not exc 50mtr and depositing where directed at a level not exc 1.50mtr above the starting points in any type soil
Dismantling of cast iron/RCC pipes jointed in cement mortor and taking out of trenches if required for 100mm pipe (Excavation & earth work will be measured and paid separately)
Dismantling of cast iron/RCC pipes jointed in cement mortor and taking out of trenches if required for 75mm pipe (Excavation & earth work will be measured and paid separately)
M&L for providing cast iron, soil & waste and vent pipes in any length, with or without ears with cement joints fixed to walls using pipes 75 mm bore.
M&L for providing cast iron soil, waste and vent pipes in any length with or without ears with cement joints fixed to walls using pipes 100 mm bore.
S&F of CI bends (any radius) diminishing pieces or taper,100mm bore in repairs.
S&F of CI bends (any radius) diminishing pieces or taper fitted with oval access doors 100 mm bore in repairs.
S&F of CI bends (any radius) diminishing pieces or taper,75 mm bore in repairs.
S&F of CI bends (any radius) diminishing pieces or taper fitted with oval access doors 75 mm dia, in repairs
S&F of CI branch pieces single (equal or unequal) ordinary or inverted (Spigot or socket type) or with parallel branches 100 mm bore.
S&F in repairs for 75mm dia PVC (SWR) grade single socketed pipes in any length complete with rubber ring joints fixed to wall or floor etc using synthetic rubber adhesive cement solvent complete all as specified and directed
S&F in repairs for 110mm dia PVC (SWR) grade single socketed pipes in any length complete with rubber ring joints fixed to wall or floor etc using synthetic rubber adhesive cement solvent complete all as specified and directed
S&F for 75mm dia PVC (SWR) bends any radius complete all as specified and directed
S&F for 75mm dia PVC (SWR) junction single(single T) complete all as specified and directed
S&F for 75mm dia PVC (SWR) branch piece single(single Y) equal or unequal complete all as specified and directed
S&F for 75mm dia PVC (SWR) vent cowl complete all as specified and directed
S&F for 110mm dia PVC (SWR) bends any radius complete all as specified and directed
S&F for 110mm dia PVC (SWR) junction single(single T) complete all as specified and directed
S&F for 110mm dia PVC (SWR) vent cowl complete all as specified and directed
S & Fin repairs precast RCC medium duty manhole covers of size 45cm x 90cm x 50 mm thick incl handle , 50 x 50 mm sqaure welded at corner and reinforced with 6 mm dia TMT bar at 150 mm centre to centre on both ways and including cover frame, complete all as specified and directed
S & F in repairs precast RCC medium duty manhole covers of size 60cm x 60cm x 50 mm thick incl handle , 50 x 50 mm sqaure welded at corner and reinforced with 6 mm dia TMT bar at 150 mm centre to centre on both ways and including cover frame, complete all as specified and directed
S & F in repairs precast RCC medium duty manhole covers of size 90cm x 90cm x 50 mm thick incl handle , 50 x 50 mm sqaure welded at corner and reinforced with 6 mm dia TMT bar at 150 mm centre to centre on both ways and including cover frame, complete all as specified and directed
S & F in repairs precast RCC medium duty manhole covers of size 45cm x 60cm x 50 mm thick incl handle , 50 x 50 mm sqaure welded at corner and reinforced with 6 mm dia TMT bar at 150 mm centre to centre on both ways and including cover frame, complete all as specified and directed
Demolition of reinforced cement concrete (reinforced cut to required to facilitate demolition) in any description and in any position not otherwise specifically provided for including removing debris outside of Md land complete all as directed.
M & L for precast RCC (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) as in cover slabs set in cement mortar (1:4) complete all as specified and as directed. (Note : Reinforcement to be measured and paid separately).
Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
Dismantling wrought iron or mild steel work of any description not otherwise provided for
S&F framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors;ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165
M&L for preparing new steel surface and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Dismantling stone slab of any description or thickness in floors, approns etc
M&L for 30mm to 25mm thick rough dressed sahabad stone slab flooring bedded and jointed in cement mortar (1:6) and pointed in CM (1:3)
Ditto all as per Item No 53 above but except sahabad stone
M & L for 18 to 20 mm thick granite stone slab (of any type ) work (table rubbed and polished ) as in floor, steps,, jambs, pillars, window cills, cooking platforms, platform in CM 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including cutting and making good for disturbed surfaces and chamfering for exposed edges,surfaces fixed in repairs all complete as directed . (Colour decided by Engineer-in-Charge)
Marble (white colour) work 18 to 20mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade of following types
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for
M & L for 75 mm thick plain cement concrete type D2 (Using 40mm graded stone aggregate) (1:4:8) as in sub base or simillar works complete all as specified and directed
M&L for 100 mm thick plain cement concrete type B2 using 40mm graded stone aggregate (1:2:4) as in hard standing /path etc or simillar works complete all as specified and directed
M&L for forming 12 mm thick Expansion joints to the full depth of pavement concrete filled with pre-formed bituminous filler and top 30 mm primed and sealed with sealing compound, Grade A thickness of slab not exceeding 20cm thick complete all as specified and direccted
M & L for forming construction/ dummy joints of size 10 mm wide x30 mm deep filled with sealing compound Grade 'A' including priming the surface complete all as specified and directed.
Dismantling floor, hearth or wall tiling/ chequered tile/interlocking tile including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises
M & L for 300X300X10mm thick glazed designer dura stone tiles of any approved colour, heavy duty machine pressed including 15 mm thick screed bed of CM(1:6) in floors complete as approved. (Make : somany)
S&F for glossy finished chequered cement concrete tiles 30cmx30cmx30mm/20 x 20 x25 mm (as approved) thick set jointed with grey cement and pigment and pointed in neat cement slurry including 20 mm thick screed bed of CM(1:6) in floors
Ditto all as per item No. 64 above but except tiles
M&L for 60 mm thick glossy finished cement concrete coloured interlocking pavers, pattern as approved, as in floors or pavements, laid on 30 mm thick stone dust cusioning, laid dry to the profile as directed incl filetting to the edges in CM (1:4), all manufacturer's instruction complete all as directed
Ditto all as per item No 66 above but except tiles
Road cutting and repair to disturbed road with PCC (1:2:4) type B2 100 m thick over 150 mm hard core of broken stone of gauge n exc 63 mm over rammed earth etc complete all including cutting of road portion as directed.
Removing demolished cement concrete material exc 1.5 Km but n.exc 5 Km and including removal of the same out side MD land and deposited at location specified by local municipal authorities.
AVS CONSTRUCTION
OM GANESH CONSTRUCTION
G V HAGAWANE
M/S CHANDAN BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .