Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹88,800Qualified Make: GWINSTEK
Model: GW Instek GDM-461 111 1ST FLOOR LAXMI DEEP TOWER LAXMI NAGAR DISTT CENTRE LAXMI NAGAR DELHI DELHI 110092 | EAST DELHI | DELHI | 110092 | Make: GWINSTEK
Model: GW Instek GDM-461 | ₹88,800 | L1 | Qualified |
| 2 | L2₹92,400+₹3,600 (4.05%)Qualified Make: GWINSTEK
Model: GW Instek GDM-461 506 701 SIDDARTH BUILDING 96 NEHRU PLACE NEW DELHI 110019 | NEW DELHI | NEW DELHI | DELHI | 110019 | Make: GWINSTEK
Model: GW Instek GDM-461 | ₹92,400+₹3,600 (4.05%) | L2 | Qualified |
| 3 | Disqualified Make: ANALYTICAL
Model: APHY3056 ANALYTICAL HOUSE E67 E68 RAVI PARK VASNA ROAD BARODA GUJARAT 390 015 | BARODA | VADODARA | GUJARAT | 390015 | Make: ANALYTICAL
Model: APHY3056 | - | - | Disqualified |
| 4 | Disqualified Make: MECO
Model: MECO 153B+ TRMS A 8 MANGALDIP APPARTMENT SAIJPUR BOGHA NARODA ROAD AHMEDABAD GUJARAT 382345 | AHMADABAD | GUJARAT | 382345 | Make: MECO
Model: MECO 153B+ TRMS | - | - | Disqualified |
| 5 | Disqualified Make: FLUKE
Model: Fluke 17B+ 66 2ND CROSS STREET PALLAVAN NAGAR EXT MADURAVOYAL CHENNAI PORUR TIRUVALLUR TAMIL NADU 600095 | CHENNAI | TAMIL NADU | 600095 | Make: FLUKE
Model: Fluke 17B+ | - | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
10 Aug 2018, 10:00 amClosed
digital multimeter Digital Multimeter ( 12 ) Technical Specifications Specification Specification Name Values Allowed Values FEATURES Type Hand Held Hand Held
Benchtop Display (Digits) 4.5 3.5
4.5
6.5 Measurement Type True RMS Average
True RMS Counts 6000 4000
6000
50000
200000 (or higher) MEASUREMENTS DC Voltage Range 1000 600
1000 DC Voltage Accuracy 0.1 0.005
0.05
0.1
0.5
1 DC Voltage resolution 0.1 0.001
0.01
1
10
100 AC Voltage Range 600 600
1000 AC Voltage Accuracy 0.1 0.08
1 AC Voltage resolution 0.1 0.001
100 DC Current Range 10 3
10 DC Current Accuracy 0.05 0.005
1.5 DC Current resolution 0.1 0.001
100 AC Current Range 10 3
10 AC Current Accuracy 0.5 0.5
1.5 1/5 AC Current resolution 0.1 0.001
100 Resistance Range 100 40
50
60
100
500 Resistance Accuracy 1 0.08
1.5
2
2.5
3
3.5 Resistance resolution 0.1 0.001
100 Capacitance Range ( Micro farad ) 1 to 200 1 to 100
1 to 200
.01 to 1000
NA Capacitance Accuracy ( % ) 3.5 1.5
3.5
5
NA Capacitance resolution ( nF ) 0.1 0.001
NA Frequency Range ( KHz ) 200 50
200
300
NA Frequency Accuracy ( % ) 0.1 0.1
NA Frequency resolution ( Hz ) 0.01 0.001
NA Temperature Range ( Degree C ) NA -40 to 400
50 to 1000
NA Temperature Accuracy ( % ) NA 1.5
NA Temperature resolution ( Degree C ) NA 0.001
NA OTHER FEATURES Continuity test and Diode test Available - Data logging Not Available - If Data Logging Feature is Available
Internal Memory NA - Computer Interface along with software Available - Dimensions ( mm X mm X mm ) 87X180X47 - Weight 370 - Other Features 46 Segments Analogue Bar; hFE Test; Data/Peak Hold and Relative Mode;30 Ranges for Function Selection
LCD Display with Visible Zone 63x29 mm - SAFETY Safety Rating Category II 1000 V of Category II 600 V of IEC 2/5 IEC 61010. 61010.
Category II 1000 V of IEC 61010.
Category III 600 V of IEC 61010.
Category III 1000 V of IEC 61010.
Category IV 600 V of IEC 61010
Category IV 1000 V of IEC 61010 Safety Certification CE
CSA
VDE - POWER REQUIREMENTS Power Requirements Battery Operated - if Battery Operated
then Type of Battery Non- Rechargeable (Alkaline) - if rechargeable
then chemistry of the battery NA - if Non-rechargeable
then size of the battery cell 9-V rectangular battery - number of non- rechargeable the battery/cell 1 - Voltage of rechargeable Battery 9 - capacity of rechargeable battery(milli Ampere Hour) 1000 - Suitable charger adaptor provided NA - ACCESSORIES Standard Accessories Supplied with the Equipment Test leads
battery and user manual - WARRANTY Warranty 3 1
5 OPERATING CONDITION Minimum Operating Temperature 0 - Maximum Operating Condition 50 - Operating Humidity (RH) 80 - TEST REPORT DETAILS The equipment supplied with calibration certificate YES - conformity to Dry Heat for 16 hrs at a specified maximum temp in accordance with IS:900 0/part-3/section-5/1977 latest true - 3/5 conformity to Cold Test for 4 hrs at a specified minimum temp in accordance with IS:900 0/part-2/section-4/1977 latest true - conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 hrs each at a temp of 40 degree C & 95% RH true - Availability of Test Reports from Central Govt/NABL/ILAC approved accredited lab to prove conformity to the specification true - Test Report Number and date for the specification test PMR-GUR140677 05-04-2017 - Name and address of the Lab for the specification test Good Will Instrument Co.
Ltd No. 7-1
Jhongsing Road
Tucheng Dist.
New Taipei City 23678
Taiwan R.O.C. - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Padmakar Rustum 421502
MACHINE TOOL PROTOTYPE FACTORY ORDNANCE ESTATE
AMBARNATH 12 30
430889
GEM/2018/B/60933
digital multimeter
30 days
Maharashtra; Thane
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| digital multimeter Digital Multimeter ( 12 ) Technical Specifications Specification Specification Name Values Allowed Values FEATURES Type Hand Held Hand Held | - | - | - |
| Benchtop Display (Digits) 4.5 3.5 | - | - | - |
| 4.5 | - | - | - |
| 6.5 Measurement Type True RMS Average | - | - | - |
| True RMS Counts 6000 4000 | - | - | - |
| 6000 | - | - | - |
| 50000 | - | - | - |
| 200000 (or higher) MEASUREMENTS DC Voltage Range 1000 600 | - | - | - |
| 1000 DC Voltage Accuracy 0.1 0.005 | - | - | - |
| 0.05 | - | - | - |
| 0.1 | - | - | - |
| 0.5 | - | - | - |
| 1 DC Voltage resolution 0.1 0.001 | - | - | - |
| 0.01 | - | - | - |
| 1 | - | - | - |
| 10 | - | - | - |
| 100 AC Voltage Range 600 600 | - | - | - |
| 1000 AC Voltage Accuracy 0.1 0.08 | - | - | - |
| 1 AC Voltage resolution 0.1 0.001 | - | - | - |
| 100 DC Current Range 10 3 | - | - | - |
| 10 DC Current Accuracy 0.05 0.005 | - | - | - |
| 1.5 DC Current resolution 0.1 0.001 | - | - | - |
| 100 AC Current Range 10 3 | - | - | - |
| 10 AC Current Accuracy 0.5 0.5 | - | - | - |
| 1.5 1/5 AC Current resolution 0.1 0.001 | - | - | - |
| 100 Resistance Range 100 40 | - | - | - |
| 50 | - | - | - |
| 60 | - | - | - |
| 100 | - | - | - |
| 500 Resistance Accuracy 1 0.08 | - | - | - |
| 1.5 | - | - | - |
| 2 | - | - | - |
| 2.5 | - | - | - |
| 3 | - | - | - |
| 3.5 Resistance resolution 0.1 0.001 | - | - | - |
| 100 Capacitance Range ( Micro farad ) 1 to 200 1 to 100 | - | - | - |
| 1 to 200 | - | - | - |
| .01 to 1000 | - | - | - |
| NA Capacitance Accuracy ( % ) 3.5 1.5 | - | - | - |
| 3.5 | - | - | - |
| 5 | - | - | - |
| NA Capacitance resolution ( nF ) 0.1 0.001 | - | - | - |
| NA Frequency Range ( KHz ) 200 50 | - | - | - |
| 200 | - | - | - |
| 300 | - | - | - |
| NA Frequency Accuracy ( % ) 0.1 0.1 | - | - | - |
| NA Frequency resolution ( Hz ) 0.01 0.001 | - | - | - |
| NA Temperature Range ( Degree C ) NA -40 to 400 | - | - | - |
| 50 to 1000 | - | - | - |
| NA Temperature Accuracy ( % ) NA 1.5 | - | - | - |
| NA Temperature resolution ( Degree C ) NA 0.001 | - | - | - |
| NA OTHER FEATURES Continuity test and Diode test Available - Data logging Not Available - If Data Logging Feature is Available | - | - | - |
| Internal Memory NA - Computer Interface along with software Available - Dimensions ( mm X mm X mm ) 87X180X47 - Weight 370 - Other Features 46 Segments Analogue Bar; hFE Test; Data/Peak Hold and Relative Mode;30 Ranges for Function Selection | - | - | - |
| LCD Display with Visible Zone 63x29 mm - SAFETY Safety Rating Category II 1000 V of Category II 600 V of IEC 2/5 IEC 61010. 61010. | - | - | - |
| Category II 1000 V of IEC 61010. | - | - | - |
| Category III 600 V of IEC 61010. | - | - | - |
| Category III 1000 V of IEC 61010. | - | - | - |
| Category IV 600 V of IEC 61010 | - | - | - |
| Category IV 1000 V of IEC 61010 Safety Certification CE | - | - | - |
| CSA | - | - | - |
| VDE - POWER REQUIREMENTS Power Requirements Battery Operated - if Battery Operated | - | - | - |
| then Type of Battery Non- Rechargeable (Alkaline) - if rechargeable | - | - | - |
| then chemistry of the battery NA - if Non-rechargeable | - | - | - |
| then size of the battery cell 9-V rectangular battery - number of non- rechargeable the battery/cell 1 - Voltage of rechargeable Battery 9 - capacity of rechargeable battery(milli Ampere Hour) 1000 - Suitable charger adaptor provided NA - ACCESSORIES Standard Accessories Supplied with the Equipment Test leads | - | - | - |
| battery and user manual - WARRANTY Warranty 3 1 | - | - | - |
| 5 OPERATING CONDITION Minimum Operating Temperature 0 - Maximum Operating Condition 50 - Operating Humidity (RH) 80 - TEST REPORT DETAILS The equipment supplied with calibration certificate YES - conformity to Dry Heat for 16 hrs at a specified maximum temp in accordance with IS:900 0/part-3/section-5/1977 latest true - 3/5 conformity to Cold Test for 4 hrs at a specified minimum temp in accordance with IS:900 0/part-2/section-4/1977 latest true - conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 hrs each at a temp of 40 degree C & 95% RH true - Availability of Test Reports from Central Govt/NABL/ILAC approved accredited lab to prove conformity to the specification true - Test Report Number and date for the specification test PMR-GUR140677 05-04-2017 - Name and address of the Lab for the specification test Good Will Instrument Co. | - | - | - |
| Ltd No. 7-1 | - | - | - |
| Jhongsing Road | - | - | - |
| Tucheng Dist. | - | - | - |
| New Taipei City 23678 | - | - | - |
| Taiwan R.O.C. - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Padmakar Rustum 421502 | - | - | - |
| MACHINE TOOL PROTOTYPE FACTORY ORDNANCE ESTATE | - | - | - |
| AMBARNATH 12 30 | - | - | - |
Exempted
10 Aug 2018
4 Aug 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_430889.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .