GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
GE UTILITY PLANT AND MACHINERY KIRBY PLACE DELHI CANTT-10
REPAIR / MAINT OF SPLIT TYPE AC 1.5/ 2TR, WINDOW AC OF CAP, 1.5 TR/2.0 TR AND WATER COOLER OF CAPACITY 40/80 AND 60/120 LTRS
2022_MES_529231_1
GE(U)/PM/3011/B/JO/21/E3
Limited
Miscellaneous Works
Piece-work
30 days
Delhi Cantt
PLEASE REFER NOTICE INVITING QUOTATION
1 document required · 1 mandatory
₹0
Exempted
25 Jun 2022
7 Jun 2022
17 Jun 2022
9 Jun 2022
15 Jun 2022
9 Jun 2022
Amount
1. Taking down for servicing of Split type Air Conditioner of Cap 1.5 (05 Nos) & of Cap 2.0 TR (03 Nos) including cleaning of cooling coil, air filter /plasma filters etc., (Indoor unit), condenser, compressor, fan motor etc., (Outdoor unit) with vacume cleaner or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, remote control unit, fan, blower, etc., and keeping the AC unit in satisfactory working condition after necessary servicing/ repair/ replacement of the following (i.e Item No 3.00) defective spares as required and refixing the same in existing position complete all specified and as directed by Engineer-in-Charge 2. Taking down for servicing of Window type AC of Cap 1.5 (05 Nos) & of Cap 2.0 TR (07 Nos) including cleaning of cooling coil, air filters , condenser, compressors, fan motor etc with vacuum cleaner OR cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, remote control unit including PCB, fan, blower, etc, changing connections from heating mode to cooling mode or vice-versa and keeping the AC unit in satisfactory working condition after necessary servicing/ repair/ replacement of the following (i.e Item No 3.00) defective spares as required and refixing the same in existing position complete all specified and as directed by Engineer-in-Charge 3. (i) Running capacitor 36 MFD (04/02Nos. -1.5/2.0 TR), Make – Jaivic/Tesla/Tipcon – 06 Nos. (ii) Starting capacitor 80-100 MFD (04/02 Nos. -1.5/2.0 TR), Make – Jaivic/Tesla/Tipcon - 07 Nos. (iii) Starting capacitor 100-120 MFD. (Make:- Epcos/ Usha/ Keltron.) - 05 Nos (iv) Main printed circuit board (PCB) with electric accessories and sensors suitable for window AC of capacity 1.5/2 TR - 08 Nos (v) Main printed circuit board (PCB) with electric accessories and sensors suitable for indoor of inverter type split AC of capacity 1.5/2 TR- 07 Nos (vi) Starting relay SR -1622 for 1.5 Ton AC, Make – Hitech – 06 Nos. (vii) Running capacitor 45+5 MFD. (Make:- Epcos/ Usha/ Keltron.) - 06 Nos (viii) 15mm bore pipe medium grade inluding fittings. (Make:- Prayag/ Supreme/ Prince.) - 20 RM (ix) Condenser motor 1/3 HP suitable for window type AC double shaft. (Make-AUE/ Crompton Greaves/Cool Master.) - 06 Nos (x) Thermostat switch 2059/2064/2054. ( Make :- Indfoss/ Renutrol) - 07 Nos (xii) Copper filter double capilary pencil type - 05 Nos (xii)Regulator knob suitable for 1.5TR/2.0TR capacity AC 04 Nos (xii) Running capacitor 50+6 MFD. (Make:- Epcos/ Usha/ Keltron.) - 06 Nos 4. Disconnecting from mains and taking out existing unserviceable sealed compressor unit from the window type Air Conditioner of Cap 2 Ton, of any make any type from any location and Supply , Installing and testing of new sealed unit compressor alongwith test certificate from manufacturer including cleaning and removing dust /dirt from the cooling coil condenser coil with necessary modification capillary tube etc & Charging of Gas R-22/R-134A/R-32 and commissioning complete all as specified & directed by Engg-in-Charge. (Make:- Emerson /Tecumseh/ LG) - 02 Nos 5. ditto- all as per item No. 4 above but spilt type Air Conditioner of Capacity 1.5 TR. (Make:- Emerson /Tecumseh/ LG) - 01 No 6. Supply and filling refrigerant gas in window type /Split Type AC unit of capacity 1.5/2TR, Water Cooler of any capacity complete in satisfactory working condition. (Make : Mefron/ Floron/ Refron.) - 80 Kgs 7. Disconnecting from mains and taking down for servicing of Water Cooler of Capacity 40/80, 60/120, Ltrs (Total 08 nos of any Capacity) including cleaning of cooling coil, air filters , condenser, compressors, fan motor etc with vacuum cleaner or cleaning solution including checking the serviceability of electrical/ electronic circuits relays, wiring kit, thermostat switches knobs, fan and blower, etc.,and keeping the Water Coolers unit in satisfactory working condition after necessary servicing/ repair/ replacement of the following (i.e Item No 6.00) defective spares as required and refixing the same in existing position complete all specified and as directed by Engineer-in-Charge - 08 Nos 8. (i) Starting relay suitable for 40/80 , 60/120 Ltr. (Make: Sri Ram/Renutrol/Micro Tech.) - 05 nos (ii) Starting Capacitor 25 MFD. (Make :- Usha/Epcos/Keltron) - 06 Nos (iii) Running Capacitor 10 MFD . (Make:- Usha/Epcos/Keltron) - 04 Nos (iv) PVC flexible drain Hose pipe 40 mm. (Make :- PRAYAG/SUPREME/PRINCE) – 07 Nos (v) Condenser fan blade aluminium body for Motor 1/32HP, 1/35HP . (Make: Tipcon/ Usha/Epcos/Keltron) - 05 nos (vi) Over load protector device for 60/120 ltrs capacity water cooler. (Make: Sri Ram/ Renutrol/Micro Tech.) - 03 Nos (vii) Over load protector device for 40/80 ltrs capacity water cooler. (Make: Sri Ram/ Renutrol/Micro Tech.) - 03 Nos (viii) Tharmostat switch. (Make: Indfoss/Renutrol/Godrej.) - 4 Nos (ix) Self closing chromium plated push taps for water cooler Capacity 40/80,60/120 Ltr. (Make: Usha/Prayag/ Cera/ Essco) - 05 Nos 9. Disconnecting the electric and Water connections and taking out the existing unserviceable compressor of any make from water cooler storage type capacity 60/120 Ltrs from any location and supply installation & testing of new sealed unit compressor of similar capacity in same location alongwith test Certificate from manufacturer and cleaning of condenser by machine doing vaccum on the fully system and supply and charging of oil gas and other necessary lubricants including reconnecting the electric and water connections, transportaion & testing complete all as directed by Engr-in-charge. (Make Tecumseh/Emerson/LG.) - 01 No 10. ditto- all as per item No. 75 above but Water cooler of capacity 40/80 Ltrs- 01 No
Trade Link
Citi Enterprises
Magic. Enterprises
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.PDF
finance_591454.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .