Loading…
Loading…
Tender Value
₹30.5 Cr
EMD Value
₹30.5 L
Closing Date
3 Aug 2026, 11:00 amClosed
Construction of the new De-Nobili School Building (Phase-I works) for the Integrated township 2X800 MW units at DVC Chandrapura, Jharkhand
NBCC/CPG/De-Nobili/Chandrapura/2026/581
NBCC/CPG/De-Nobili/Chandrapura/2026/581
Open Tender-Domestic
Civil Works General
Neemuch, Madhya Pradesh
₹59,000
₹30.5 L
3 Aug 2026
11 Jul 2026
3 Aug 2026
3 Aug 2026
S. DSR AMOUNT DSR AMOUNT NON-DSR TOTAL AMOUNT
ABSTRACT OF COST CIVIL WORK
Sr No Sub Head DSR Amount Non DSR Amount Total Amount
Sr No Sub Head DSR Amount Non DSR Amount Total Amount
3 Reinforced Cement Concrete 123725272.11 0.00 123725272.11
11 Dismantling & Demolishing Work 361147.5 0.0 361147.48
Digitally signed by DIWAKAR
14 Structural Glazing Work 4683299.56 0.00 4683299.56
15 Miscellaneous Work 0.00 2997287.97 2997287.97
Digitally signed by DIWAKAR
PROPOSED CONSTRUCTION OF RESIDENTIAL & NON RESIDENTIAL BUILDINGS FOR CTPS TOWNSHIP AT CHANDRAPURA, JHARKHAND.
ESTIMATE - DE-NOBILI SCHOOL BUILDING
2023 with Non DSR
Sl.No. DSR 2023 Description Unit Quantity DSR Amount
I 2.0 EARTH WORK
Carriage of materials by Mechanical Transport including loading, unloading and stacking
of Earth up to 5 km
Earth work in excavation by mechanical means {Hydraulic excavator)/ manual means
over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan)
including getting out and disposal of excavated earth lead upto 50 m and for all lift, as
directed by Engineer-in-charge.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations
3 2.25 etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by cum 3247.77 209.78 681313.13
ramming and watering, lead up to 50 m and lift up to 1.5 m.
Supplying and filling in plinth with sand under floors, including watering, ramming,
consolidating and dressing complete.
Surface dressing of the ground including removing vegetation and inequalities not
exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.
Supplying chemical emulsion in sealed containers including delivery as specified..
6.1 2.34.1 Chlorpyriphos/ Lindane emulsifiable concentrate of 20% litre 951.30 251.25 239016.91
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite
treatment (excluding the cost of chemical emulsion) :
Treatment of soil under existing floors using chemical emulsion @one litre per hole, 300
7.1 2.35.3 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1
cement: 2 Coarse sand) to match the existing floor:
7.1.1 2.35.3.1 With Chlorpyriphos/Lindane E.C. 20% with 1% concentration sqm 4756.50 331.85 1578427.95
TOTAL EARTH WORK AMOUNT 4725741.56
II 4.0 CONCRETE WORK
Providing and laying in position cement concrete of specified grade excluding the cost of
centering and shuttering - All work up to plinth level :
1:2:4 (1 cement : 2 coarse sand) derived from natural sources : 4 raded stone aggregate
20 mm nominal size derived from natural sources)
Digitally signed by DIWAKAR
1:3:6 (1 Cement : 3 coarse sand (zone-Ill) derived from natural sources :6 graded stone
aggregate 40 mm nominal size derived from natural sources)
Centering and shuttering including strutting, propping etc. and removal of form work for :
9.1 4.3.1 Foundations, footings, bases for columns sqm 134.15 419.72 56305.11
Providing and laying damp-proof course 50 mm thick with cement concrete 1:2:4 (1
10 4.11 cement: 2 coarse sand (zone-Ill) derived from natural sources: 4 graded stone aggregate sqm 364.86 530.60 193593.17
20 mm nominal size derived from natural sources).
Extra for providing and mixing water proofing material in cement concrete work in doses per
by weight of cement as per manufacturer's specification. bag of
Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved
quality using 1.7 kg per square metre on damp proof course after cleaning the surface
with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand
(zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size
13 4.17 derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal sqm 324.95 801.98 260602.03
size, well rammed and consolidated and grouted with fine sand, including necessary
excavation, levelling & dressing & finishing the top smooth.
TOTAL CONCRETE WORK AMOUNT 3942091.45
III 5.0 REINFORCED CEMENT CONCRETE
14 5.9 Centering and shuttering including strutting, propping etc. and removal of form for
14.1 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete sqm 824.02 419.72 345854.80
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses
14.3 5.9.3 Suspended floors, roofs, landings, balconies and access platform sqm 7293.91 992.44 7238732.28
14.4 5.9.4 Shelves (Cast in situ) sqm 38.04 992.44 37753.05
14.5 5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers sqm 10117.76 788.17 7974504.23
14.6 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts sqm 4761.33 1028.88 4898837.39
14.7 5.9.7 Stairs, (excluding landings) except spiral-staircases sqm 184.48 818.73 151034.97
Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string
courses, bands, copings, bed plates, anchor blocks and the like
14.9 5.9.16 Edges of slabs and breaks in floors and walls
14.10 5.9.19 Weather shade, Chajjas, corbels etc., including edges sqm 335.01 1017.96 341027.56
Extra for additional height in centering, shuttering where ever required with adequate
bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a
height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be
15.1 5.11.1 Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) sqm 411.32
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in
position and binding all complete upto plinth level.
Digitally signed by DIWAKAR
16.1 5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. kg 175216.59 115.43 20225575.87
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in
position and binding all complete above plinth level.
17.1 5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. kg 337262.39 115.43 38930823.77
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
Providing and laying in position ready mixed or site batched design mix cement concrete
for reinforced cement concrete work; using coarse aggregate and fine aggregate derived
from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement,
admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of
concrete, to improve durability and workability without impairing strength; including
pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost
of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-
19 5.33 charge; for the following grades of concrete.
Note: Extra cement up to 10% of the minimum specified cement content in design
mix shall be payable separately. In case the cement content in design mix is more
than 110% of the specified minimum cement content, the contractor shall have
discretion to either re-design the mix or bear the cost of extra cement.
19.1 5.33.1 All works upto plinth level
a 5.33.1.1 Concrete of M25 grade with minimum cement content of 330 kg /cum cum 1401.73 10172.93 14259734.24
19.2 5.33.2 All works above plinth level upto floor V level
a 5.33.2.1 Concrete of M25 grade with minimum cement content of 330 kg /cum cum 2698.10 10553.59 28474621.77
Floor Joint 100mm Providing & Fixing of Expansion Joint system related with the Floor to
Floor/ Floor to Wall Expansion Joint Cover for 100 mm Expansion Joints Aluminium
Covers Profiles, having a Hard Wearing, Maintenance Free, long Lasting design. The
surface of the Exp. Joint Covers should have Serrated Surface for Skid Resistance and
should be ADA Compliant. The exposed surface should not exceed 113mm.The design of
the Exp. Joint Cover System should be such that it should avoid any accumulation of dirt.
20 5.44 The Exp. Joint Cover should have an Articulated Telescope Design so as to
accommodate the movements in 3 directions. The system should be in alloy 6063 T66 in
Mill finish and the total exposed surface of the profile should not be more than 113 & the
installation Height can be of 35 mm. The system can be used for standard Rolling loads
of private Cars or Cart wheel loads. The system should have ASTM1399 E certification.
The extrusion should be as ASTM 6063 T66 standards. The System shall be such that it
will be flushed with the finish The System should be ASTM-E 1399. Provision of Moiser
Barrier in the Joint System to have watertight joint is mandatory requirement all as per the
manufactures design and as approved by the Engineer-in-Charge.
20.1 5.44.1 Floor Joint of 100 mm gap metre 17.10 6841.95 116997.28
Digitally signed by DIWAKAR
Providing & Fixing of Expansion Joint system related with the WALL to WALL (Internal /
External) Location as per drawing and direction of engineer –In- Charge. Expansion Joint
The design of the Joint Cover System should be such that the system should snap onto a
50mm wide, hook shaped aluminum clip. The system should have gasket seals on the
21 5.45 edges to provide scratch protection to the wall finish and prevent accumulation of dust.
The system should be in 6063 alloy in clear anodized matt finish. Provision of Moisture
Barrier Membrane in the Joint System to have watertight joint is mandatory requirement
for all external area as per the manufactures design and as approved by the Engineer-in-
Providing and fixing of expansion joint system of approved make and Manufactures for
various roof locations as per approved drawings and Direction of Engineer-In-Charge.
The joints shall be of extruded aluminium base members with, self aligning and self
centring arrangement support plates as per ASTM B221-02. The system shall be such
that it provides watertight roof to roof/roof to corner joint cover expansion control system
that is capable of accommodating multidirectional seismic movement without stress to its
components. System shall consist of metal profile that incorporates a universal
aluminium base member designed to Accommodate various project conditions and roof
treatments. The cover plate shall be designed of width and thickness required to satisfy
movement and loading requirements and secured to base members by utilizing
22 5.46 manufacturer’s pre-engineered self-centring arrangement that freely rotates / moves in all
directions. The Self centring arrangement shall exhibit circular sphere ends that lock and
slide inside the corresponding aluminium extrusion cavity to allow freedom of movement
and flexure in all directions including vertical displacement. The Joint System shall
resists damage or deterioration from the impact of falling ice, exposure to UV, airborne
contaminants and occasional
foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the
Joint System to have water tight joint is mandatory requirement. (Material shall confirm to
22.1 5.46.1 Roof Joint of 100 mm gap metre 8.56 6406.49 54839.59
TOTAL REINFORCED CEMENT CONCRETE AMOUNT 123725272.11
IV 6.0 MASONRY WORK
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in
foundation and plinth in:
23.1 6.1.2 Cement mortar 1:6 (1 cement : 6 coarse sand) cum 19.86 7633.65 151592.78
Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150 mm to
300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to
15:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at
sill level and lintel level with approved block laying polymer modified adhesive mortar all
complete as per direction of Engineer-in-Charge. (The payment of RCC band and
reinforcement shall be made for separately).
Digitally signed by DIWAKAR
Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry 100 mm/ 125
mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to 15:2185
25 6.38 (Part 3) in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cum 389.69 10912.19 4252330.73
cement :4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm
dia M.S. bars at every third course of masonry work.
TOTAL MASONRY WORK AMOUNT 24108745.42
V 8.0 CLADDING WORK
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and
prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and
similar locations of required size, approved shade, colour and texture laid over 20 mm
26 8.2 thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white
cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing,
moulding and polishing to edges to give high gloss finish etc. complete at all levels.
26.1 8.2.2 Granite stone slab colour black, Cherry/Ruby red
a 8.2.2.2 Area of slab over 0.50 sqm sqm 26.82 5497.38 147443.08
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including
27 8.3 machine polishing to edge to give high gloss finish etc. complete as per design approved
by Engineer-in-Charge.
Extra for fixing marble /granite stone, over and above corresponding basic item, in facia
28 8.4 and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. metre 44.70 608.52 27201.41
Extra for providing opening of required size & shape for wash basin/ kitchen sink in
kitchen platform, vanity counter and similar location in marble/ Granite/ stone work,
including necessary holes for pillar taps etc. including moulding, rubbing and polishing of
cut edges etc. complete.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622
(thickness to be specified by the manufacturer), of approved make, in all colours, shades
except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in
30 8.31 skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement sqm 548.17 1357.09 743907.53
: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing
in white cement mixed with pigment of matching shade complete.
Stone tile work for wall lining upto 10 m height with special adhesive over 12 mm thick
31 7.38 bed of cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement
with an admixture of pigment to match the stone shade.
31.1 7.38.1 8 mm thick (mirror polished and machine cut edge)
33.1.1 7.38.1.1 Granite stone of any colour and shade sqm 24.40 3312.10 80815.16
TOTAL CLADDING WORK AMOUNT 1063617.91
VI 9.0 WOOD AND P. V. C. WORK
Digitally signed by DIWAKAR
Providing and fixing ISi marked flush door shutters conforming to IS : 2202 (Part I) non-
decorative type, core of block board construction with frame of 1st class hard wood and
well matched commercial 3 ply veneering with vertical grains or cross bands and face
veneers on both faces of shutters:
31.1 9.21.1 35 mm thick including ISi marked Stainless Steel butt hinges with necessary screws sqm 546.72 2560.85 1400069.71
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all
edges of flush door shutters (over all area of door shutter to be measured).
Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of
glass excluded) (overall area of door shutter to be measured):
33.1 9.24.1 Rectangular or square sqm 546.72 213.15 116533.50
Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured).
Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel
screws etc. complete:
Providing and fixing aluminium extruded section body tubular type universal hydraulic
door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight
upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed
adjustment with necessary accessories and screws etc. complete.
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less
37 9.97 than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with
necessary screws etc. complete :
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less
38 9.1 than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with
necessary screws etc. complete :
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic
39 9.101 coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required
colour and shade, with necessary screws etc. complete.
39.1 9.101.2 Twin rubber stopper each 339.00 77.44 26250.87
Providing and fixing ISI marked aluminium sliding door bolts anodised (anodic coating not
less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade
with necessary screws etc. complete.
Providing and fixing bright finished brass 100 mm mortice latch and lock, ISi marked, with
six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS :
1868) aluminium lever handles of approved quality with necessary screws etc. complete.
Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss
/ matt/ suede finish with high density protective surface layer and reverse side of
adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of
approved quality.
Digitally signed by DIWAKAR
Providing and fixing bright /matt finished Stainless Steel handles of approved quality &
make with necessary screws etc all complete.
Providing and fixing panic bar/ latch (Double point) fitted with a single body, Trim Latch &
44 9.139 Lock on back side of the Panic Latch of reputed brand and manufacture to be approved each 36.00 8954.29 322354.45
by the Engineer- in- charge, all complete.
Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontal side &
35 x 60 mm on vertical sides having built in rebate made out of 1.6 mm thick GI sheet
(Zinc coating not less than 120 gm/sqm) suitable for mounting 120 minutes Fire Rated
Glazed Door Shutters. The frame shall be filled with mineral wool Insulation having
density minimum 96Kg/sqm. The frame will have a provision of G.I. anchor fastners 14
45 9.161 nos (5 each on vertical style & 4 on horizontal style of size M10 x 80) suitable for fixing in metre 124.20 2357.76 292834.27
the opening along with factory made template for SS ball bearing hinges of size 100x89x3
mm for fixing of fire rated glazed shutter. The frame shall be finished with an approved
fire resistant primer or powder coating of not less than 30 micron in desired shade as per
the directions of Engineer - in- Charge. (Cost of SS ball bearing hinges is excluded).
Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 minutes Fire
rating conforming to IS:3614 (Part II) or EN1634-1:1999, tested and certified as per
laboratory approved by Engineer-in-Charge, with suitable mounting on door frame,
consisting of vertical styles, top rail & side rail 60 mm x 60 mm wide and bottom rail of
110 mm x 60 mm made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/
sqm) duly filled mineral wool insulation having density minimum 96 kg/ cum and fixing
with necessary stainless steel ball bearing hinges of size 100x89x3 mm of approved
make, including applying a coat of approved fire resistant primer or powder coating not
less than 30 micron etc all complete as per direction of Engineer-in-Charge (panelling to
be paid for separately).
Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc.,
with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120
gm/sqm) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm
from the edges and 150 mm c/c , including applying a coat of approved fire resistant
primer/ powder coating of not less than 30 micron on G.I. beading, & special ceramic tape
of 5 x 20 mm size etc complete in all respect as per NBC 2016, IS 16231 (Part 3):2016
and as per direction of Engineer-in-Charge with glass of required thickness having 120
minutes of fire resistance both integrity & radiation control (EW120) and minimum 20
47 9.164 minutes of insulation (El20). The manufacturer have to give test report/certification of fire sqm 61.97 46748.19 2896751.52
glass and the glass should have the stamp showing the value of E, EW & El. The glass
shall be tested in approved NABL accredited lab or by any other accreditation body which
operates in accordance with ISO/IEC 17011 and accredited labs as per ISO/IEC 17025
for testing and
calibration scopes shall be eligible. The maximum glazing size shall not be more than
1100x2200 mm (w x h) or 2.42 sqm.
Digitally signed by DIWAKAR
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid
door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC
polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers
(wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of
12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and
screwed with full body threaded star headed SS screws having minimum frame density of
750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum
compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to
44 26.86 spread of flame of Class A category with property of being termite/borer proof,
proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of
required dia and length complete as per direction of Engineer-In- Charge. (M.S hold
fast/lugs or SS dash fasteners shall be paid for separately).
Note: For WPC solid door/window frames, minus 5 mm tolerance in dimensions i.e depth
and width of profile shall be acceptable. Variation in profile dimensions on plus side shall
be acceptable but no extra payment on this account shall be made.
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid
plain flush door shutter of required size comprising of virgin polymer of K value 58-60
(Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat
husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having
minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N
(Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and
45 26.87 resistance to spread of flame of Class A category with property of being termite/borer
proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of
required size with necessary full body threaded star headed counter sunk S.S screws, all
as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary
S.S screws shall be paid separately)
TOTAL WOOD AND P. V. C. WORK AMOUNT 8873105.18
VII 10.0 STEEL WORK
Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard
with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred,
46 10.15 welded and grinded finish, with profiles of required size, including fixing of necessary butt
hinges and screws and applying a priming coat of approved steel primer.
Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm
46.1 10.15.1 of C.C. 1:3:6 (1 Cement : 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) kg 7206.55 208.92 1505610.87
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc.,
including cutting, hoisting, fixing in position and applyinga priming coat of approved steel
primer, including welding and bolted with special shaped washers etc. complete.
47.1 10.16.2 Hot finished seamless type tubes kg 41612.00 220.86 9190276.72
Digitally signed by DIWAKAR
Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener
of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head,
48 10.27 comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame ,
concrete/ masonry, etc. as per direction of Engineer-in-charge.
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels,
plates etc., including welding, grinding, buffing, polishing and making curvature (wherever
required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c
fixing the railing with necessary accessories & stainless steel dash fasteners , stainless
steel bolts etc., of required size, on the top of the floor or the side of waist slab with
suitable arrangement as per approval of Engineer-incharge, (for payment purpose only
weight of stainless steel members shall be considered excluding fixing accessories such
as nuts, bolts, fasteners etc.).
TOTAL STEEL WORK AMOUNT 14030734.55
VIII 11.0 FLOORING WORK
52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm
thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20
mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1
50 11.4 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, sqm 127.11 1047.24 133119.07
hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's
specifications. This includes cost of cement slurry, but excluding the cost of nosing of
steps etc. complete.
Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement :3 coarse
sand), finished with a floating coat of neat cement.
Providing and laying matt finished vitrified tile of size 300x300x9.8 mm having with water
absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours
and shades in for outdoor floors such as footpath, court yard, multi modals location etc.,
laid on 20 mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes &
patterns including grouting the joints with white cement mixed with matching pigments etc.
complete as per direction of Engineer-in-Charge.
53 11.24 Extra for pre finished nosing to treads of steps of marble/granite stone. metre 792.65 770.51 610743.94
Extra for marble/granite stone flooring in treads of steps and risers using single length
up to 2.00 metre.
Kata stone slab flooring over 20 mm (average) thick base laid over and jointed with grey
cement slurry mixed with pigment to match the shade of the slab, including rubbing and
polishing complete with base of cement mortar 1 :4 (1 cement: 4 coarse sand):
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm
(average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey
cement slurry mixed with pigment to match the shade of the slabs, including rubbing and
polishing complete.
Digitally signed by DIWAKAR
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be
specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make
in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement
mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm
including pointing the joints with white cement and matching pigment etc., complete.
Providing and laying double charge vitrified floor tiles in different sizes (thickness to be
specified by the manufacturer) with water absorption less than 0.08% and conforming to
IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement
mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm
including grouting the joints with white cement and matching pigments etc., complete.
58.1 11.41A.1 Double charge vitrified tile polished finish of size
58.2 11.41A.3 Glazed Vitrified tiles Matt/Antiskid finish of size
Providing and laying double charge vitrified tiles in different sizes (thickness to be
specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S.
15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm
thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry
@ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc.
Providing and laying Polished Granite stone flooring in required design and patterns, in
linear as well as curvilinear portions of the building all complete as per the architectural
drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar
60 11.56 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white
cement slurry admixed with pigment of matching shade including rubbing, curing and
polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
60.1 11.56.1 Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent sqm 3481.81 4796.34 16699922.29
TOTAL FLOORING WORK AMOUNT 12600.27 31690419.13
IX 12.0 ROOFING WORK
Providing corrugated G.S. sheet roofing including vertical I curved surface fixed with
polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet
washers or with G.I. limpet washers filled with white lead, including a coat of approved
61 12.1 steel primer and two coats of approved paint on overlapping of sheets complete (up to
any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters
and trusses and including cutting to size and shape wherever required.
61.1 12.1.1 1.00 mm thick with zinc coating not less than 275 gm/m2 sqm 974.45 1559.59 1519737.06
Providing and fixing 15 cm wide, 45 cm overall semi-circular plain G.S. sheet gutter with
62 12.7 iron brackets 40x3 mm size, bolts, nuts and washers etc., including making necessary
connections with rain water pipes complete.
62.1 12.7.1 0.80 mm thick with zinc coating not less than 275 gm/m2 metre 121.00 1102.03 133346.16
Digitally signed by DIWAKAR
Providing and fixing precoated galvanised steel sheet roofing accessories of total coated
thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating
63 12.51 thickness of 0.05 mm) with Zinc coating 120 gram per sqm as per IS: 277, in 240 mpa
steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-
18 microns using self drilling/ self tapping screws complete :
63.1 12.51.2 Flashings/ Aprons.( Upto 600 mm) metre 121.00 519.74 62888.26
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone
64 12.21 aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement
: 3 fine sand) as per standard design :
Providing and fixing false ceiling at all height including providing and fixing of frame work
made of special sections, power pressed from M.S. sheets and galvanized with zinc
coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle
cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm
centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm
long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50
mm of required length with nuts & bolts of required size and other end of angle hanger
fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm
centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with
tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall
be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips
made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing
65 12.45 perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long,
the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre,
with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to
ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm
at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square
edges of the board with recommended jointing compound , jointing tapes , finishing with
jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats
of primer suitable for board, all as per manufacturer's specification and also including the
cost of making openings for light fittings, grills, diffusers, cutouts made with frame of
perimeter channels suitably fixed, all complete as per drawings, specification and
direction of the Engineer in Charge but excluding the cost of painting with :
12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011
(Board with BIS certification marks)
65.2 12.45.3 12.5 mm thick tapered edge gypsum moisture resistant board sqm 58.12 1636.60 95117.05
Digitally signed by DIWAKAR
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true
horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel
sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main 'T
runner with suitably spaced joints to get required length and of size 24x38 mm made from
0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ·r of size
24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main
"T" at 600 mm center to center to fonn a grid of 1200x600 mm and secondary cross "T" of
length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be
interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall
66 12.52 angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid
including, required cutting/making, opening for services like diffusers, grills, light fittings,
fixtures, smoke detectors etc. Main " runners to be suspended from ceiling using GI
slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm
long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size
85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed
width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for
all heights as per specifications, drawings and as directed by Engineer-in-charge.
12.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass
fibre conforming to IS: 2095 part I, of size 595x595 mm, having perforation of 9.7x9.7 mm
66.1 12.52.4 at 19.4 mm c/c with center borders of 48 mm and the side borders of 30 mm, backed with sqm 507.60 1635.42 830138.12
non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.79,
with 50 mm resin bonded glass wool backing.
Providing and Fixing 15mmthick densified tegular edged eco friendly light weight calcium
silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level,
suspended on inter locking metal grid of hot dipped galvanised steel sections
(galvanising@ 120 grams per sqm including both side) consisting of main 'T runner
suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm
thick (minimum) sheet, spaced 1200 mm centre to centre, and cross "T" of size 24x28
mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main'T' at
600 mm centre to centre to form a grid of 1200x600 mm and secondary cross 'T' of length
600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked
at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on
periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000
66 12.53 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre
to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick
densified edges calicum silicate ceiling tiles of approved texture in the grid, including,
cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke
detectors etc., wherever required. Main 'T' runners to be suspended from ceiling using
G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long
dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30
x 0.8 mm, spaced at 1200 mm centre to centre along main 'T. Bottom exposed with 24
mm of all T-sections shall be pre-painted with polyster baked paint, for all heights, as per
specifications, drawings and as directed by Engineer-in-Charge..
Digitally signed by DIWAKAR
Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No
deduction shall be made for exposed frames/opening (cut outs) having area less than
0.30 sqm.The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light sqm 232.48 2309.87 536987.38
eflection > 85%, non- combustible as per B.S. 476 part IV, 100% humidity resistance and
also having thermal conductivity <0.043 w/mK.
Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI
(solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on
waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the
67 12.55 ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & sqm 2709.91 1823.74 4942160.43
marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts
complete, including providing skirting upto 150 mm height along the parapet walls in the
TOTAL ROOFING WORK AMOUNT 6776010.21
X 13.0 FINISHING WORK
68 13.4 12 mm cement plaster of mix :
69 13.5 15 mm cement plaster on rough side of single or half brick wall of mix:
70 13.16 6 mm cement plaster of mix :
Extra for plastering exterior walls of height more than 10 m from ground level for every
additional height of 3 m or part thereof.
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to
prepare the surface even and smooth complete.
Painting with synthetic enamel paint of approved brand and manufacture to give an even
73.1 13.62.1 Two or more coats on new work sqm 166.45 242.16 40306.28
74 13.46 Finishing walls with Acrylic Smooth exterior paint of required shade :
New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of
exterior primer applied @ 0.90 litre/10 sqm)
Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound )
75 13.82 content less than 50 grams/ litre, of approved brand and manufacture, including applying
additional coats wherever required, to achieve even shade and colour.
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less
76 13.41 than 50 gram/litre, of approved manufacturer and of required shade and colour all
complete to achieve even shade and colour :
New work (two or more coats) over and including water thinnable priming coat with
cement primer having VOC content less than 50 gram/litre
TOTAL FINISHING WORK AMOUNT 25281000.26
XI 15.0 DISMANTLING AND DEMOLISHING WORK
Demolishing cement concrete manually/ by mechanical means including disposal of
material within 50 metres lead as per direction of Engineer - in - charge.
77.1 15.2.2 Nominal concrete 1:4:8 or leaner mix (including equivalent design mix) cum 25.29 1609.30 40699.27
Digitally signed by DIWAKAR
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars
78 15.3 and disposal of unserviceable material within 50 metres lead as per direction of Engineer - cum 25.29 3800.90 96124.83
Demolishing brick work manually/ by mechanical means including stacking of serviceable
79 15.7 material and disposal of unserviceable material within 50 metres lead as per direction of
Engineer-in-charge.
Dismantling manually/ by mechanical means including stacking of serviceable material
80 15.4 and disposal of unserviceable material within 50 metres lead as per direction of Engineer-
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste
materials by mechanical means, including loading, transporting, unloading to approved
municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial
lead, for all leads including all lifts involved.
Carriage of materials by Mechanical Transport including loading, unloading and stacking
of Building Rubbish
TOTAL DISMANTLING AND DEMOLISHING WORK AMOUNT 361147.48
XII 21.0 ALUMINIUM WORK
Providing and fixing double action hydraulic floor spring of approved brand and
manufacture conforming to IS : 6315, having brand logo embossed on the body / plate
with double spring mechanism and door weight upto 125 kg, for doors, including cost of
83 21.4 cutting floors, embedding in floors as required and making good the same matching to
the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet
outer box with slide plate etc. complete as per the direction of Engineerin- charge.
83.1 21.4.1 With stainless steel cover plate minimum 1.25 mm thickness each 2.00 3022.37 6044.73
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved
brand and manufacture, including providing and fixing top & bottom pivot & double acting
84 21.18 hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing sqm 4.10 5700.31 23371.27
required door fittings, all complete as per direction of Engineer-in-charge (Door handle,
lock and stopper etc.to be paid separately).
Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/Brick/ Stone/
wood/ Ceramic/ Gypsum work by providing weather/ structural non sag elastomeric PU
85 21.19 sealant over backer rod of approved quality as per architectural drawings and direction of
Engineer-in-charge complete, complying to ASTM C920, DIN 18540-F & ISO 11600
85.1 21.19.1 Upto 5 mm depth and 5 mm width metre 3490.30 158.51 553252.44
TOTAL ALUMINIUM WORK AMOUNT 582668.45
XIII 22.0 WATER PROOFING WORK
Digitally signed by DIWAKAR
Providing and laying water proofing treatment to vertical and horizontal surfaces of
depressed portions of W.C., kitchen and the like consisting of:
(i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing
compound conforming to IS : 2645 in recommended proportions including rounding off
junction of vertical and horizontal surface.
(ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water
86 22.3 proofing compound in recommended proportion including rounding off junction of vertical sqm 198.23 823.70 163285.71
and horizontal surface.
(iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of
(iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should
be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm).
Providing and spray applying two component hybrid polyuria polyurethane waterproofing
87 22.27 system at all levels for podium garden waterproofing by the manufacturer or his approved
applicator consistin of following operations -
(a) Brushing and vacuum cleaning the surface to make free from any loose material, oil,
grease, burr, dirt, dust etc.
(b) Repairing the surface if required, as per recommendation of manufacturer or his
approved applicator to make it water tight for which nothing extra shall be paid.
(c) Providing and applying by spray or brush, two component solvent free resin/ epoxy
primer mixed in proportion of volume / weight as recommended by manufacturer over
cement concrete surface in dry condition, having consumptionvaries from 0.20 to 0.40
kg/sqm depending on the porosity and undulations in the surface.
(d) Providing and sprinkling washed coarse sand, as recommended by manufacturer,
overfreshly laid primed tacky surface @ 0.25 to 0.40 kg/sqm as directed by Engineer-in-
(e) Over primed sandy surface, providing and spray applying two component hyrbrid
polyurea polyurathane coating system, which shall be solvent free, mixed in proportion by
volume / by weight as recommended by manufacturer having elongation > 400%, shore a
hardness > 75 (after 28 days), tensile strength of minimum of 10MPa as per DIN / ASTM
and tear strength minimum 30 N/mm as per DIN 53515 or minimum 45 N/mm as per
ASTM D624 and 20 maximum gel time / reaction time with minimum 1.5 mm dry film
thickness of two coats.
Digitally signed by DIWAKAR
(f) A layer of non woven polypropleyne geotextile of minimum mass / unit area of 120 gsm
with an overlap of 50 mm shall be laid over the polyurea/ polyurethane coatin surface,
having minimum tensile strength 2.40 KN/m as per ASTM D 4595.
(g) Providing and laying screed of cement concrete 1:1.5:3 ( 1 Cement : 1.5 Coarse Sand
: 3 Graded stone aggregate 20 mm nominal size) of minimum thickness 50 mm at
khurrah with a slope of 1:100 towards khurra to ridge of roof (screed shall be paid for
(h) Providing and laying dimple drain boards with inbuilt geo textile drainage membrane
on top having dimple height of 20-25 mm, average number of dimples 400 per sqm,
compressive strength not less than 180 KN/sqm and geotextile member having mass of
120 gsm, laid with minimum overlap of 50 mm.
Note : If HDPE drain cells / Drainmats along with a layer of geotextile having weight of
120 gsm and tensile strength not less than 2.4 KN/m as per ASTM D 4595 is provided in
place of dimple drain board with inbuilt geotextile, it shall not be paid exttra.
22.27.1 New work on horizontal surfaces sqm 2709.91 2891.90 7836773.60
TOTAL WATER PROOFING WORK AMOUNT 8000059.31
XIV 25.0 STRUCTURAL GLAZING WORK
Providing and supplying aluminium extruded tubular and other aluminium sections as per
the architectural drawings and approved shop drawings , the aluminium quality as per
grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80
microns conforming to AAMA 2604 of required colour and shade as approved by the
Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws
etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be
paid on this account). The weight of aluminium extruded section shall be taken for
purpose of payment.
Designing, fabricating, testing, protection, installing and fixing in position semi (grid)
unitized system of structural glazing (with open joints) for linear as well as curvilinear
portions of the building for all heights and all levels, including:
(a) Structural analysis & design and preparation of shop drawings for the specified design
loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times
89 25.2 design wind pressure without any failure), including functional design of the aluminum
sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and
splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather
silicone sealants, flashings, fire stop (barrier)- cum-smoke seals, microwave cured EPDM
gaskets for water tightness, pressure equalisation & drainage and protection against fire
hazard including:
Digitally signed by DIWAKAR
(b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005
T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional
movement for achieving perfect verticality and fixing structural glazing system rigidly to
the RCC/ masonry/structural steel framework of building structure using stainless steel
anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and
washers etc. of stainless steel grade 316, of the required capacity and in required
(c) Providing and filling, two part pump filled, structural silicone sealant and one part
weather silicone sealant compatible with the structural silicone sealant of required bite
size in a clean and controlled factory / work shop environment, including double sided
spacer tape, setting blocks and backer rod, all of approved grade, brand and
manufacture, as per the approved sealant design, within and all around the perimeter for
(d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of
sizes, shapes and profiles, as required as per the site conditions, to seal the gap between
the building structure and all its interfaces with curtain glazing to make it watertight.
(e) Making provision for drainage of moisture/ water that enters the curtain glazing system
to make it watertight, by incorporating principles of pressure equalization, providing
suitable gutter profiles at bottom (if required), making necessary holes of required sizes
and of required numbers etc. complete. This item includes cost of all inputs of designing,
labour for fabricating and installation of aluminium grid, installation of glazed units, T&P,
scaffolding and other incidental charges including wastages etc., enabling temporary
structures and services, cranes or cradles etc. as described above and as specified.
Digitally signed by DIWAKAR
The item includes the cost of getting all the structural and functional design including
shop drawings checked by a structural designer, dully approved by Engineer-in-charge.
The item also includes the cost of all mock ups at site, cost of all samples of the individual
components for testing in an approved laboratory, field tests on the assembled working
structural glazing as specified, cleaning and protection till the handing over of the building
for occupation. In the end, the Contractor shall provide a water tight structural glazing
having all the performance characteristics etc. all complete as required, as per the
Architectural drawings, as per item description, as specified, as per the approved shop
drawings and as directed by the Engineer- in-Charge.
Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded
aluminium section capping for fixing in the grooves of the curtain glazing and vermin
proof stainless steel wire mesh shall be paid for separately under relevant items under
this sub- head. However, for the purpose of payment, only the actual area of structural
glazing (including width of grooves) on the external face shall be measured in sqm. up to
two decimal places. Note:-2. The following performance test are to be conducted on
structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified
laboratories accreditated by NABL(National Accreditation Board for Testing and
Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is
payable separately. The NIT approving authority will decide the necessity of testing on
the basis of cost of the work, cost of the test and importance of the work. Performance
Testing of Structural glazing system Tests to be conducted in the NABL accredited lab or
any other accreditation body which operates in accordance with ISO/IEC 17011 and
accredits labs as per ISO/IEC 17025 1. Performance Laboratory Test for Air Leakage
Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a
testing limit 1 to 200 mVhr
2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing
method for a range up to 2000 ml.
3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method
for a range upto 2000 ml
4. Structural Performance Deflection and deformation by static air pressure test (1.5 times
design wind pressure without any failure) as per ASTME-330-10 testing method for a sqm 12.48 3757.29 46872.17
range upto 50 mm
5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for
Qualitative test, Tests to be conducted on site.
6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto
Digitally signed by DIWAKAR
Providing, assembling and supplying vision glass panels (IGUs) comprising of
hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size
and shape as required and specified, comprising of an outer heat strengthened float
glass 6 mm thick, of approved colour and shade with reflective soft coating on surface # 2
of approved colour and shade, an inner Heat strengthned clear float glass 6 mm thick,
spacer tube 12 mm wide, dessicants, including primary seal and secondary seal
(structural silicone sealant) etc. all complete for the required performances, as per the
Architectural drawings, as per the approved shop drawings, as specified and as directed
by the Engineerin- Charge. The IGUs shall be assembled in the factory/ workshop of the
glass processor.
TOTAL STRUCTURAL GLAZING WORK AMOUNT 4683299.56
XV MISCELLANEOUS WORK
Supply & Fixing 5 Knuckle, 2 bearing butt hinges size 4" x 3" x 3mm, in SS 304 and in
91 MR-1 satin stainless steel. As per EN 1935, CE Marked. Suitable for door weights upto 120kgs. each 108.00 491.00 53028.00
as per direction of engineer-in-charge
Supply & Fixing rack and pinion door closer EN size 3-6, with standard arm and two
independent closing valves and latching speed adjustable by arm. All adjustment screws
face fixed with slide plate. For Door width upto 1400mm Silver finish. As per EN 1154 and
CE marked. as per direction of engineer-in-charge
Supply & Fixing Automatic door bottom RP8si seal from Raven,extruded silicon sealing
component, spring loaded to lift clear of the floor. Concealed mounted in a 15mm x 34mm
groove. Max gap 13mm. Finish: Anadoised satin clear. L=920mm as per direction of
engineer-in-charge
Supply & Fixing Surface mounted door coordinator for double doors SR 390, zinc plated
94 MR-4 for steel doors, non-Handed as per EN 1158 and CE marked. as per direction of engineer- each 36.00 14163.00 509868.00
Supply & Fixing Delta Seal for acoustic, fire and smoke protection, suitable for wooden
95 MR-5 and steel frames, self adhesive, Finish = Black, Length = 1 x 2000mm, Height- 2 x each 36.00 7180.00 258480.00
2750mm as per direction of engineer-in-charge
Providing and fixing G.I. chicken wire mesh having wire of thickness 22 SWG and
minimum aperture of 20mmx20mm of approved quality over the junction of R.C.C
96 MR-6 member and brick/AAC wall including fixing with U nails/screws 150 mm centre to centre Sqm 3278.57 238.00 780299.97
in both direction before plastering etc. all complete as per the direction of Engineer-in-
TOTAL MISCELLANEOUS WORK AMOUNT 2997287.97
Digitally signed by DIWAKAR
Name of Project : CONSTRUCTION OF INTEGRATED TOWNSHIP AT CHANDRAPURA, JHARKHAND
Name of Work : Plumbing Works
DE NOBILI SCHOOL
S. No. Description PLUMBING
DSR NSR Total
1 Internal Plumbing Works. 34,57,587.16 3,02,323.00 37,59,910.16
Grand Total 37.60 Lakh
Grand Total 37.60 Lakh
Digitally signed by DIWAKAR
Name of Project : CONSTRUCTION OF INTEGRATED TOWNSHIP AT CHANDRAPURA, JHARKHAND
Name of Work : Plumbing Works
DE NOBILI SCHOOL
Ref. DSR- DSR Rate
S. No. Description of Item Unit Qty
2023/MR DSR NSR
1.0 Internal Plumbing Works.
1 17.10 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as
per IS 13983 with C.I. brackets and stainless steel plug 40 mm
including painting of fittings and brackets, cutting and making
good the walls wherever required :
a 17.10.1.3 Kitchen sink with drain board 510x1040 mm bowl depth 200 mm
2 17.31 Providing and fixing mirror of superior glass (of approved quality)
complete with 6 mm thick hard board ground fixed to wooden
cleats with C.P. brass screws and washers complete.
3 17.28 Providing and fixing P.V.C. Waste pipe for sink or wash basin
including P.V.C. waste fittings complete.
a 17.28.1 Semi rigid pipe
4 DSR-17.22A Providing and fixing CP Brass 32mm size Bottle Trap of approved
quality & make and as per the direction of Engineer-in-charge.
5 DSR-17.34 Providing and fixing toilet paper holder :
Digitally signed by DIWAKAR
17.2 Providing and fixing white vitreous china pedestal type water
closet (European type W.C. pan) with seat and lid, 10 litre low
level white P.V.C. flushing cistern, including flush pipe, with
manually controlled device (handle lever), conforming to IS :
7231, with all fittings and fixtures complete, including cutting and
making good the walls and
floors wherever required :
6 17.2.1 W.C. pan with ISI marked white solid plastic seat and lid Each 48.00 6973.59 334732.47 0.00
6a 17.1 Providing and fixing water closet squatting pan (Indian type W.C.
pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level
white P.V.C. flushing cistern, including flush pipe, with manually
controlled device (handle lever) conforming to IS : 7231, with all
fittings and fixtures complete, including cutting and making good
the walls and floors wherever required
17.1.1 White Vitreous china Orissa pattern W.C. pan of size 580x440
mm with integral type foot rests Each 6.00 7243.14822 43458.89 0.00
7.00 ,18.49 Providing and fixing C.P. brass bib cock of approved quality
conforming to IS:8931 :
8.00 ,18.53 Providing and fixing C.P. brass angle valve for basin mixer and
geyser points of approved quality conforming to IS:8931
Digitally signed by DIWAKAR
9.00 17.7 Providing and fixing wash basin with C.I. brackets, 15 mm C.P.
brass pillar taps, 32 mm C.P. brass waste of standard pattern,
including painting of fittings and brackets, cutting and making
good the walls wherever require:
17.7.1 White Vitreous China Wash basin size 630x450 mm with a pair of
15 mm C.P. brass pillar taps] Each 46.00 2835.06 130412.95 0.00
10.00 18.21 Providing and fixing uplasticised PVC connection pipe with brass
18.21.2 45 cm length
11.00 18.22 Providing and fixing C.P. brass shower rose with 15 or 20 mm
12.00 17.22B Providing and fixing CP Brass Single lever telephonic wall mixer of
quality & make as approved by Engineer in charge.
NS-12 Providing & Fixing CP Brass Shower Spout Each 3.00 2952.00 0.00 8,856.00
13.00 NS-2 Providing and fixing C.P. cast brass twin coat hooks fixed to PVC
rawl plug with SS screws. Each 59.00 1315.00 0.00 77,585.00
14.00 NS-3 Providing and fixing of ABS health spary which can tolerate water
pressure up to 6 bar flow pressure with metal hose and holder in
Polished Chrome. Each 59.00 1613.00 95,167.00
15.00 NS-4 Providing, fixing, testing and commissioning of CP brass swan
neck wall mounted sink mixer with wall flange and swinging
casted spout complete as required and making good the walls
wherever required. [Make :Euronics, Model:FLO-3012A or
equivalent/as per approved make list].
Digitally signed by DIWAKAR
16.00 17.72 Providing and fixing PTMT towel ring trapezoidal shape 215 mm
long, 200 mm wide with minimum distances of 37 mm from wall
face with concealed fittings arrangement of approved quality and
colour,weighing not less than 88 gms. Each 46.00 248.26 11419.78 -
17.00 18.65 Providing and fixing PTMT soap Dish Holder having length of
138mm,breadth 102mm, height of 75mm with concealed fitting
arrangements,weighing not less than 106 gms.
19.00 17.5 Providing and fixing white vitreous china flat back half stall urinal
of size 580x380x350 mm with white PVC automatic flushing
cistern, with fittings, standard size C.P. brass flush pipe, spreaders
with unions and clamps (all in C.P. brass) with waste fitting as per
IS : 2556, C.I. trap with outlet grating and other couplings in C.P.
brass, including painting of fittings and cutting and making good
the walls and floors wherever required :
17.5.1 Single half stall urinal with 5 litre P.V.C. automatic flushing cistern
20.00 17.73 Providing and fixing PTMT towel rail complete with brackets fixed
to wooden cleats with CP brass screws with concealed fittings
arrangement of approved quality and colour.
17.73.1 450mm long towel rail with total length of 495mm. 78mm wide
and effective height of 88mm, weighing not less than 170 gms
21.00 NS-5 Supply, installation, testing and commissioning of horizontal type
storage hot water heater within-built pressure relief valve, rated
for inlet water pressure upto 6 bar complet in all respects
including inlet, oulet connections, fixing bolts etc. and testing
Digitally signed by DIWAKAR
B Soil, Waste, Vent & Rain Water Pipes
21.00 12.22 Making khurras 45x45 cm with average minimum thickness of 5
cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded
stone aggregate of 20 mm nominal size) over P.V.C. sheet
1mx1mx400micron, finished with 12mm cement plaster 1:3 (1
cement : 3 coarse sand) and a coat of neat cement, rounding the
edges and making and finishing the outlet complete.
22.00 Providing and fixing to the inlet mouth of rain water pipe cast
DSR-12.44 iron grating 15 cm diameter and weighing not less than 440
23.00 17.35 Providing and fixing soil, waste, vent and rain water pipes
Hubless centrifugally cast iron pipes epoxy coated inside &
24.00 Providing and fixing MS holder bat clamps of approved design to
cast iron (spun) pipe embedded in and Including cement concrete
blocks 10 x10 x10cm of 1:2:4 mix (1 cement : 2 coarse sand : 4
17.37 graded stone aggregate 20mm nominal size) including cost of
cutting holes and making good the walls etc.
25.00 Providing and fixing bend of required degree with access door,
17.38 insertion rubber washer 3mm thick, bolts and nuts complete.
Hubless centrifugally cast iron epoxy coated inside & outside IS :
Digitally signed by DIWAKAR
26.00 17.39 Providing and fixing plain bend of required degree.
Hubless centrifugally cast iron epoxy coated inside & outside IS :
27.00 Providing and fixing double equal plain junction of required
Hubless centrifugally cast iron pipes epoxy coated inside &
28.00 Providing and fixing single equal plain junction of required degree
Hubless centrifugally cast iron epoxy coated inside & outside IS :
29.00 Providing and fixing single unequal plain junction of required
Hubless centrifugally cast iron epoxy coated inside & outside IS :
30.00 Providing and fixing Hubless cast iron offsets epoxy coated inside
& outside as per IS : 15905
17.54A.1 130 mm offsets
31.00 17.56 Providing and fixing terminal guard:
Hubless centrifugally cast iron epoxy coated inside & outside IS :
Digitally signed by DIWAKAR
32.00 Providing and fixing shielded coupling for Hubless centrifugally
17.57A.1.1 SS 304 grade coupling with EPDM rubber gasket Each 210.00 462.423115 97,108.85
33.00 Painting with synthetic enamel paint of approved drand and
manufacture to give an even shade
13.61.1 Two more coast on new work sqm 170.00 166.86 28366.16
34.00 4.1 Providing and laying in position cement concrete of specified
grade excluding the cost of centering and shuttering - All work up
to plinth level:
4.1.3 1:2:4 (1 cement :2 coarse sand: 4 hard stone aggregate 20mm
35.00 ,17.60 Providing and fixing trap of self cleansing design with screwed
down or hinged with or without vent arm complete, including
cost of cutting and making good the walls and floors.
a 17.60.1 100 mm inlet and 100 mm outlet
17.60.1.3 Hubless centrifugally cast (spun) iron epoxy coated inside &
outside as per IS:15905 Each 44.00 914.62 40243.49 0.00
b 17.60.2 100 mm inlet and 75 mm outlet
17.60.3 Hubless centrifugally cast (spun) iron epoxy coated inside &
outside as per IS:15905 Each 31.00 632.98 19622.24 0.00
36.00 NS-6 Circular type 125 mm nominal dia [Make :Euronics, Model:
EFG01P-55or equivalent/as per approved make list].
Digitally signed by DIWAKAR
Circular type 125 mm nominal dia [Make :Euronics, Model:
EFG01P-55 or equivalent/as per approved make list].
37.00 Fire DSR 27.8 Providing, laying, testing & commissioning of 'B' class heavy duty
G.I. pipe conforming to IS 1239 including welding, fittings like
elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing
the pipe on the wall/ceiling with suitable clamp/support frame
and painting with two or more coats of synthetic enamel paint of
required shade complete as required :
For WB, Urinal FT & FD and Sink Drain pipe
38.00 12.41 Providing & fixing on wall face unplasticised -Rigid PVC rain water
pipes conforming to IS:13592 Tyape A included jointing with seal
ring conforning to IS:5382 leaving 10 mm gap for thermal
expansion. (i)Single socketed pipes.
39.00 12.42 Providing, fixing on wall face unplasticised - PVC moulded fittings
/accessories for unplasticised - Rigid PVC rain water pipes
conforming to IS ; 13592 Type A including jointing with seal ring
conforming to IS ; 5382 leaving 10 mm gap for thermal
39.00 NS 7 Providing and fixing of 110x75 mm dia uPVC Balcony Drain
Digitally signed by DIWAKAR
C Internal Water Supply
41.00 18.70 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,
having thermal stability for hot & cold water supply including all
CPVC plain & brass threaded fittings i/c fixing the pipe with
clamps at 1.00 m spacing. This includes jointing of pipes & fittings
with one step CPVC solvent cement and testing of joints
complete as per direction of Engineer in Charge.
Internal Work - Exposed on Wall
a 18.7.3 25 mm nominal outer dia .Pipes. Metre 240.00 429.78 103146.95 0.00
a 18.7.4 32 mm nominal outer dia .Pipes. Metre 125.00 555.22 69402.27 0.00
b 18.7.5 40 mm nominal outer dia .Pipes. Metre 55.00 752.37 41380.21 0.00
18.7.6 50 mm nominal outer dia .Pipes. Metre 45.00 999.82 44991.93 0.00
42.00 ,18.8 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,
having thermal stability for hot & cold water supply including all
CPVC plain & brass threaded fittings i/c fixing the pipe with
clamps at 1.00 m spacing. This includes jointing of pipes & fittings
with one step CPVC solvent cement and the cost of cutting chases
and making good the same including testing of joints complete as
per direction of Engineer in Charge.
Concealed work including cutting chases and making good the
a 18.8.2 20 mm nominal outer dia .Pipes. Metre 365.00 575.39 210018.55 0.00
b 18.8.3 25 mm nominal outer dia .Pipes. Metre 185.00 671.35 124198.95 0.00
43.00 ,18.10 Providing and fixing G.I. pipes with two coats of anti-corrosive
bitumastic paint of approved quality : complete with G.I. fittings
and clamps, i/c cutting and making good the walls etc.
Internal work - Exposed on Wall
Digitally signed by DIWAKAR
a 18.10.1 & 15 mm dia nominal bore
b 18.12.2 & 20 mm dia nominal bore
44.00 Fire DSR - 27.8 Providing, laying, testing & commissioning of 'B' class heavy duty
G.I. pipe conforming to IS 1239 including welding, fittings like
elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing
the pipe on the wall/ceiling with suitable clamp/support frame
and painting with two or more coats of synthetic enamel paint of
required shade complete as required :
c DSR Fire-27.8.1 25 mm dia nominal bore
d DSR Fire-27.8.2 32 mm dia nominal bore
e DSR Fire-27.8.3 40 mm dia nominal bore
f DSR Fire-27.8.4 50 mm dia nominal bore
g DSR Fire-27.8.5 65 mm dia nominal bore
h DSR Fire-27.8.6 80 mm dia nominal bore
DSR Fire-27.8.7 100 mm dia nominal bore
Digitally signed by DIWAKAR
45.00 DSR-18.32 Constructing masonry Chamber 30x30x50 cm inside, in brick work
in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock,
with C. I. surface box 100x100 x75 mm (inside) with hinged cover
fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand
: 4 graded stone aggregate 20 mm nominal size), i/c necessary
excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand :
10 graded stone aggregate 40 mm nominal size ) and inside
plastering with cement mortar 1:3 (1 cement : 3 coarse sand)
12mm thick, finished with a floating coat of neat cement
complete as per standard design :
a 18.32.1 With common burnt clay F.P.S.(non modular) bricks of class
46.00 DSR-18.48 Providing and placing on terrace (at all floor levels) polyethylene
water storage tank, IS : 12701 marked, with cover and suitable
locking arrangement and making necessary holes for inlet, outlet
and overflow pipes but without fittings and the base support for
47.00 DSR-18.77 Making core cutting machine up to 15x15 cm in R.C.C. floors and
roofs for passing drain pipe etc. and repairing the hole after
insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement
: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size),
including finishing complete so as to make it leak proof.
48.00 18.17 Providing and fixing gun metal gate valve with C.I. wheel of
approved quality (screwed end) :
Digitally signed by DIWAKAR
49.00 DSR Fire- Supplying, fixing, testing and commissioning of butterfly
27.11.5 valve of PN 1.6 rating with bronze/gunmetal seat duly ISI
marked complete with nuts, bolts, washers, gaskets
conforming to IS 13095 of following sizes as required :
50.00 18.19 Providing and fixing gun metal non- return valve of approved
quality (screwed end) :
51.00 Providing and fixing forged brass ball valve of brass body with
hard chrome plated steel ball inside PTFE (Teflon) seat & ring with
chrome plated centre handle with female BSP threads complete
in all respects.
a NS-8 15 mm nominal bore Each 34.00 368.00 0.00 12512.00
b NS-9 20 mm nominal bore Each 66.00 513.00 0.00 33858.00
52.00 NS 10 Providing and fixing forged brass single acting air release valve
with screwed inlet 25 mm dia. Each 12.00 656.00 0.00 7872.00
53.00 Providing and fixing ball valve (brass) of approved quality, High or
18.18 low pressure, with plastic floats complete :.
Digitally signed by DIWAKAR
Solar Water Heaters
54.00 Supply, erection, testing & commissioning of solar water
NS-11 heating system with following details :
System temperature output : 60 degree C (during clear sunny
System type : Thermo syphon
System : Non Pressurised
Application : Bathing / Washing / Cooking
Type of Solar Collectors : Copper tube Flat Plate Collectors as per
BIS with following specifications -
Size of Collector : 2080 x 1070 x 100 mm
Number of Collector : To suit system requirement.
Absorber area : 2 sq M
Weight : 46 Kg (Dry)
Absorber Coating : Selective - NALSUN
Absorbivity : > 0.95
Emissivity : < 0.2
Frame Material : 16 SWG extruded Aluminium
Glazing : Toughened Glass
Glass beeding : EPDM
Finish : Painted by approved shade
Hot water return pump
Hardware : SS 304
Insulation : PUF
Collector Stand : 35x35x3 mm MS angle
Hot Water Tank : Cylindrical - vertical / horizontal, Stainless steel
304 grade with 100 mm thick Rock Wool insulation including 22
SWG aluminium cladding.
Digitally signed by DIWAKAR
The entire system should be complete with internal piping in
SS(304) with 50 mm rock wool insulation of density 48 kg/m3
with 26 SWG Al cladding, necessary isolation valves, Y type CI
strainer, hardwares, temperature gauge of range 0 - 120oC, water
meter, MS angle iron structure of min thickness 3 mm duly
painted etc as required to complete the system in all respects.
The entire system should be approved by BIS as per IS : 12933
and as per local regulations.
System Capacity : 1500 liters ( storage tank of 2,000 litres ) per
day (LPD) having 15 collectors. Item 0.00 702339.00 - 0.00
Total C/F to Summary 34,57,587.16 3,02,323.00
Digitally signed by DIWAKAR
Summary of Cost
Project - Proposed Construction of Integrated Township at Chandrapura, Jharkhand.
Name of Block - DE Nobili School.
DSR-2025 Market Based
S.No. Description Total Amount
S.No. Description Total Amount
1 Cost of Internal Electrification & UPS Work 1,99,30,328.95 61,07,165.76 2,60,37,494.71
2 Cost of Fire Detection & Alarm Work 2,81,769.00 - 2,81,769.00
3 Cost of CCTV Surveillance Work 3,62,880.00 - 3,62,880.00
6 Cost of AV System Work 10,50,659.85 -
7 Cost of On-Grid Solar Power Backup System Work (50KWp) 27,14,000.00
Digitally signed by DIWAKAR
Detailed Estimate Based On DSR-2022 With Cost Index & Market Rate
Project - Proposed Construction of Integrated Township at Chandrapura, Jharkhand.
Name Of Work -DE Nobili School Internal Electrification Work
Rate as per D.S.R. 2025 (For
without GST DSR rates = MARKET BASED
Sr.N Rate as per
Particulars Sch.No. Qty Unit Amount Rate Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell
point with 1.5 sq.mm FRLS PVC insulated copper conductor
single core cable in surface / recessed medium class PVC
1 conduit, with modular switch, modular plate, suitable GI box 1.10.3 1,212.00 Nos. 1,704.00 20,65,248.00 -
and earthing the point with 1.5 sq.mm FRLS PVC insulated
copper conductor single core cable etc. as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC
insulated copper conductor single core cable in surface/
2 recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC 1.12 10,550.00 Meter 373 39,35,150.00 -
insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the
following sizes of FRLS PVC insulated copper conductor, single core cable
in surface/ recessed medium class PVC conduit as required.
Supplying and drawing following pair 0.5 mm dia FRLS PVC
insulated annealed copper conductor, unarmored telephone
cable in the existing surface/ recessed steel/ PVC conduit as
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper
conductor PE insulated, shielded with fine tinned copper braid and
protected with PVC sheath in the existing surface/ recessed steel/ PVC
conduit as required.
Supplying and fixing of following sizes of medium class PVC
conduit along with accessories in surface/recess including
cutting the wall and making good the same in case of recessed
conduit as required.
Digitally signed by DIWAKAR
Supplying and fixing following modular switch/ socket on the
7 existing modular plate & switch box including connections but 1.24 - -
excluding modular plate etc. as required.
a Telephone socket outlet 1.24.6 27.00 Each 168 4,536.00 -
b TV socket outlet 1.24.7 5.00 Each 168 840.00 -
c RJ45 socket cat 6 with shutter RA-1 156.00 Each - 487.56 76,060.01
Supplying and fixing two module stepped type electronic fan
8 regulator on the existing modular plate switch box including 1.25 423.00 Each 402 1,70,046.00 -
connections but excluding modular plate etc. as required.
Supplying and fixing following size/ modules, GI box alongwith
9 modular base & cover plate for modular switches in recess etc. 1.27 - -
Supplying and fixing suitable size GI box with modular plate and cover in
front on surface or in recess, including providing and fixing 3 pin 5/6 A
modular socket outlet and 5/6 A modular switch, connections etc. as
Supplying and fixing suitable size GI box with modular plate and cover in
front on surface or in recess, including providing and fixing 6 pin 5/6 &
15/16 A modular socket outlet and 15/16 A modular switch, connections
etc. as required.
Installation ,Testing, Commissioning of wall bracket /ceiling
fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps
per fitting, complete with all accessories including connections etc. as
Supplying and fixing call bell/ buzzer suitable for single phase,
230 V, complete as required.
Installation of exhaust fan in the existing opening, including making good
the damage, connection, testing, commissioning etc. as required.
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing
surface/ recessed Steel/ PVC conduit as required.
Wiring for group controlled (looped) light point/fan
point/exhaust fan point/ call bell point ( without independent
switch etc.) with 1.5 sq. mm FRLS PVC insulated copper
conductor single core cable in surface/ recessed PVC conduit,
and earthing the point with 1.5 sq. mm FRLS PVC insulated
copper conductor single core cable etc. as required.
Digitally signed by DIWAKAR
Supplying and fixing suitable size GI box with modular plate and cover in
front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6
17 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. 1.56 197.00 Each 757 1,49,129.00 -
as required. (For light plugs to be used in non residential buildings).
Supplying & fixing suitable size GI box wih modular plate and
cover in front on surface or in recess including providing and
fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve
including connections, painting etc. as required.
Supplying and fixing following way, horizontal type three pole
and neutral, sheet steel, MCB distribution board, 415 V, on
surface/ recess, complete with tinned copper bus bar, neutral
bus bar, earth bar, din bar, interconnections, powder painted
including earthing etc. as required. (But without
MCB/RCCB/Isolator)
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve,
miniature circuit breaker suitable for inductive load of following poles in
the existing MCB DB complete with
connections, testing and commissioning etc. as required.
b Double pole 2.10.3 1.00 Each 696 696.00 -
c Three Phase & Neutral 2.10.5 33.00 Each 1301 42,933.00 -
Supplying and fixing 63Amp, four pole, (three phase
and neutral), 415 volts, residual current circuit breaker (RCCB),
21 having a sensitivity current 300 mA in the existing MCB DB RA-3 1.00 Each - 5,906.79 5,906.79
complete with connections, testing and commissioning etc. as
required. Similar to Legrand or equivalent.
Supplying and fixing 40/63A rating, 415 V, 10 kA, "C" curve, miniature
circuit breaker suitable for inductive load of Four poles in the existing MCB
22 DB complete with connections, testing and commissioning etc. as required. RA-4 34.00 Each - 2,604.69 88,559.31
Similar to Legrand DX3 AC MCBs or equivalent.
Supplying and installing following size of perforated painted
with powder coating M.S. cable trays with perforation not more than
23 17.5%, in convenient sections, joined with connectors, suspended from the 4.1 - -
ceiling with M.S. suspenders including bolts & nuts, painting suspenders
etc as required.
a 100 mm width X 50 mm depth X 1.6 mm thickness 4.1.1 100.00 Each 623 62,300.00 -
Digitally signed by DIWAKAR
b 300 mm width X 50 mm depth X 1.6 mm thickness 4.1.4 70.00 Each 866 60,620.00 -
c 600 mm width X 50 mm depth X 1.6 mm thickness 4.1.7 70.00 Each 1482 1,03,740.00 -
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick
including accessories, and providing masonry enclosure with
cover plate having locking arrangement and watering pipe of
2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre
below ground as strip earth electrode, including connection/
25 terminating with G.I. nut, bolt, spring, washer etc. as required. 5.9 200.00 Meter 160.00 32,000.00 -
(Jointing shall be done by overlapping and with 2 sets of G.I. nut
bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I.
26 pipe from earth electrode including connection with G.I. nut, 5.11 180.00 Meter 755 1,35,900.00 -
bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in
recess for connections etc. as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess
28 for loop earthing along with existing surface/ recessed conduit/ 5.18 200.00 Meter 50 10,000.00 -
submain wiring/ cable as required.
LED Down lighter (SMD Type) (System lumen efficacy >135 lm/Watt)
Supplying, installation, Testing & Commissioning of LED Recessed /
surface Down lighter (Round /square/Rectangular) SMD type of following
body material with PMMA and prismatic diffuser and construction as per
IS : 10322 with driver as per the requirement with Driver efficiency >85%,
Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -
15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short
& Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR
(Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life
time (LED,Driver & electrical circuitry), life time of minimum 50000
Burning Hours with , 70% of initial Lumen maintained till life ends as per
29 LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 8.3
5700°K / 6000°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation
Color Matching) <3, Maximum power consumption should not more than
the specified rating and Fixture shall be of relevant BIS standard and trade
mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/
Embossing/ Screen printing on housing. OEM must have its own in house
NABL lab setup for all testing facilities for LED fixtures. complete in all
respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper
conductor single core cable and earthing etc. as required
Digitally signed by DIWAKAR
with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt
output . LM79 & LM80 Test report from NABL lab for all testing required
for LED fixtures as per BIS shall be submitted. Shape size and CCT shall
be as approved by Engineer-in-Charge as per requirement. (Thermal
management: heat sink of aluminum housing such that LED junction
temperature shall not rise above 90°C).
Powder coated die cast / Extruded aluminum Body including trim.
SITC of 12W Extruded aluminium batten available in 2ft run length with
multiple lumen packages and suitable for surface, wall & conduit ounting
(with accessories). similar to Philips Type HSN Code MRP (INR) BN 021
LED12S 6500 PSU GR or equivalent.
Supply and fixing of water tight oblong 10 Watt LED bulkhead luminaire having
pressure diecast housing with driver set confirming to IP 65 and above Protection,
IK08, High purity / transmisivity UV stablized Non yellowish diffuser/ Reflector
for uniform light distribution, ditachable driver set, suitable for 24hrs continuous
32 operation complete in all respect. MR 5.00 Each - 2367.08 11,835.40
1200 system lumen, >120lm/W, PF>0.95, CRI>70, >300V, over voltage
protection, 4KV internal surge protection with 5 year warrenty. CAT-AAA
Digitally signed by DIWAKAR
LED Batten light (System lumen efficacy >135 lm/Watt)
Supplying, installation, Testing & Commissioning of LED surface mounted
Batten light of following body material and construction as per IS : 10322 with
driver (Replaceable) as per the requirement with Driver efficiency >85%
,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -
15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short &
Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , Flicker
free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry),
of minimum 50000 Burning Hours with , 70% of initial Lumen
maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/
6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching)
<3, Maximum power consumption should not more than the specified rating
and Fixture shall be of relevant BIS standard and trade mark certificate (
T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen
printing on housing. OEM must have its own in house NABL lab setup for
all testing facilities for LED fixtures. complete in all respect i/c
connections with 1.5 sq mm FRLS, PVC insulated copper conductor
single core cable and earthing etc. as required with Minimum 5 year OEM
warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test
report from NABL lab for all testing required for LED fixtures as per BIS
shall be submitted. Shape size and CCT shall be as approved by Engineerin-
Charge as per requirement. (Thermal management: heat sink of
aluminum housing such that LED junction temperature shall not rise above
Powder coated die cast /Extruded aluminum Body (Thickness ≥ 1.20
Digitally signed by DIWAKAR
Supply of 250mm exhuast fan having Built with a durable powder-coated
metal body, this 150 mm exhaust fan brings both style and resilience to
kitchens, bathrooms, or compact spaces.
Equipped with a fast-spinning 1200 RPM motor, it swiftly eliminates
steam, smoke, and odors for a fresher indoor atmosphere.
The compact 250 mm sweep ensures a perfect wall or window installation
without sacrificing airflow.
Precision balanced metal blades deliver steady, powerful airflow while
keeping vibrations and noise minimal.
34 Designed to be energy-efficient, it uses approximately 48 W, offering strong RA-20 51.00 Each - 1,763.37 89,931.66
performance without raising your electricity bill.
Operates quietly around 40–45 dB, making it ideal for use near bedrooms,
studies, or any quiet area.
Comes with a sturdy steel bird guard to prevent insects and debris from
entering, protecting hygiene and motor health.
Featuring a corrosion-resistant finish, it stays looking fresh and functioning
well even in humid conditions.
Maintenance is hassle-free—blades and grill detach easily for quick
cleaning to ensure consistent airflow.
Digitally signed by DIWAKAR
LED Flood Light, powder coated pressure die cast aluminum (System lumen
efficacy ≥120 and <135 lm/Watt)
Supplying, installation, Testing & Commissioning of Flood Light, powder coated
pressure die cast aluminum body with built in or separate driver as per the
requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270
Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade,
internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency
under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for
beam angle 30 deg- 120deg as per the application and the project requirement
deg, suitable tilt able fitting, life time (LED,Driver & electrical circuitry) of
minimum 50000 Burning Hours with 70% of initial Lumen maintained till life
ends as per LM80 extrapolation IES TM-21-11 report , CCT 3000°K / 4000°K /
5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color
Matching) <5, Maximum power consumption should not more than the specified
rating and Fixture shall be of relevant BIS standard complete in all respect i/c
connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core
cable and earthing etc. as required with Minimum 5 year OEM warranty. System
lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report from
NABL lab for all testing required for LED fixtures as per BIS shall be submitted.
Shape size and CCT shall be as approved by Engineer-in-Charge as per
requirement. (Thermal management: heat sink of aluminum housing such that
LED junction temperature shall not rise above 90°C).
Brush Less Direct Current (BLDC) Fan without Remote
Supply, Installation, Testing and Commissioning of ceiling fan with Brush
Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(
Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle
kit, safety rope, copper winding, steel/Al body
Power Factor not less than 0.9, Service Value (CM/M/W) minimum as
below, 350 RPM (tolerance as, per IS : 374-2019), THD (Total Harmonic
Distortion) less than 10%, suitable for operation with regulator for speed
control and all remaining accessories including safety pin, nut bolts,
washers, temperature rise=75 0C (max.), insulation resistance more than 2
mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan
compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm
FRLS/HFFR, PVC insulated copper conductor single core cable and
earthing etc. as required.
1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min
Digitally signed by DIWAKAR
Supply and fixing hexagonal Round G.P.fan box approved make made up
of 1.0 mm thick ISI Marked G.P.sheet spot welded Four to Eight holes for
pipe entry of the box. Holes should be semi-shuttered type with 0.5 mm
37 G.P. Sheet made upper & lower cover duly screwed. Fixing with wiring 423.00 Each 220.65 93,334.95 -
conduit laid in the R.C.C. roof before concreting alongwith supply of all 2023 10.18
material, labour, T&P etc. required for proper completion of the work.
Supply Installation Testing and Commissioning of 400mm sweep
38 1500RPM energy efficient BLDC fan with double ball bearing for longer RA-2 2.00 Each - 6,359.54 12,719.08
life similar to CGE RENESA or equivalent.
SITC of 30W Dali copatible light for Auditorium similar to Philips Green
Space G6 or equivalent.
Lightning Arrestor Work - -
Lightning Arrestor: Supply, installation, testing and commissioning of
External Lightning wide area protection system based on Eaarly Streamer
Emission (ESE) technology. Device shall emit electromagnetic impulse in
the form of a streamer into the air microseconds earlier than naturally
40 formed streamers. Device confirmg to NFC 17-102 and UNE 21186 MR 2.00 Each - 62,304.00 1,24,608.00
Standards. Appropriate non penetrating mounting arrangement. The device
shall be mounted at suitable clear to the highest point on the roof top.
(Model selected shall give coverage of 79 M radius @ min 5M height from
Down conductor:Supply, installation, testing and commissioning of 70
41 Sqmm twisted 19-Strand, bare Cu cable on surface/wall / as per site MR 150.00 Metre - 2,510.92 3,76,638.30
requirement and complete in all respect.
Lightning Counter :Supply and installation of counting the number of
lightning strikes without any power supply.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm
thick including accessories, and providing masonry enclosure
with cover plate having locking arrangement and watering pipe
of 2.7 metre long etc. with charcoal/ coke and salt as required.
44 Test Link :Supply and installation of test link in weather proof IP 65 BOX. MR 6.00 Each - 2,832.00 16,992.00
Supply, installation, testing and commisioning of 2 x 25W LED Aviation
abstruction light medium bay type 62, complete with lamp, lamp holder,
Condenser necessary connecting wire, 1 X 25 AV with all necessary
hardware, accessories as required for complete installation. Rate shall
include the cost of necessary steel structures , fixing arrangements in this
item. Refer drawing.
Digitally signed by DIWAKAR
Online UPS- Input supply: Three Phase, Output supply: Three Phase
Supplying, installation, Testing & Commissioning of of following capacity
at full load (Unity Power Factor) at operating temperature 0 to 40 deg C,
Relative humidity 0 to 95%, Online double conversion true sine wave
Uninterrupted hot swappable (allow for the replacement or addition of
battery modules without shutting down the entire system) modular Power
Supply (UPS) system with N+1 modules (N denotes total number of
46 moduels requird for rated capacity). The UPS shall include a Rectifier, -
inverter, battery bank suitable for 30 minutes back up (Battery VAH
capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour
backup time) on full load (Battery shall be VRLA, SMF in ABS Container)
and Static Bypass switch alongwith provision for manual bypass, suitable
isolation transformer for additional protection against neutral faults etc.
UPS shall have inbuilt
phase sequence correction. The UPS systems offered are to be of the latest
technology with Digital Control Microprocessor based for reliable operation
using Insulated Gate Bipolar Transistor (IGBT)'s both for the rectifier &
inverter (3 Level) with PWM (Pulse Width Modulation). The quality of
design, manufacturing and inspection process should confirm to the relevant
International standards such as IEC/EN/VDE. The operating efficiency of
the UPS systems shall be >96% while operating on battery mode and
delivering quality power to the 100% non-linear loads. Current total
harmonic effect(ITHD) on the input grid shall be < 5% at 50 %load. (The
inductor (L) and a capacitor (C)) filters shall be included in UPS cost),
extreme power factor kit to be included to limit the input power factor (PF)
to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS
shall be kva rating x 1 ), however UPS shall be suitable to take load at 0.7
laging to 0.7 leading power factor loads. UPS shall be suitable for incoming
supply AC : 3Phase 400V +/-20%, 50 Hz +/-5 Hz, AC Output voltage:
3Phase 415 Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins,
Sine wave output. Non condensing, noise level less than 60db at 1 meter
distance, protections: Input Under voltage over voltage, abnormal out
voltage, battery over charging, output over current, short circuit protection,
battery deep discharge protection, 10KV surge. UPS must comply with low
voltage electromagnetic compatibility (EMC) achieved as per EN 6204,
EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent
(VFI)-type UPS. Communication RS232/RS485/SNMP port open protocol
Digitally signed by DIWAKAR
integration, all hardware & software for iOT Communication as per
approved by Engineering in charge. Required battery racks and
interconnecting copper conductor cables of suitable size and connectors and
all required accoseries are inclusive of the cost). This system must provide a
means for logging and alarming of all monitored points plus email
notification. Forced air-cooling with integral inbuilt fans with redundancy
(if one fan fail UPS should be able to handle at least 80% of the load, Noise
Level 65 DB at 1 meter distance. The system shall be in compliance IEC
62040- 1,2 & 3, IS: 16242 and CPWD Specification. Display Panel
(minimum) (In-build 5 inch or more LC Display / LED ) to display : a)
Input: Voltage, current, Frequency. b) Bypass: Voltage, Frequency. c)
Output: Voltage, frequency, Current.
d) Battery: Voltage, Capacity. e) Load: KVA, KW, Percentage.
f)Temperature: STS, Inverter, PFC. g) Event Logging & Statistical Data
LCD/LED): UPS should capture and display up to 3000 events like: Over
temperature / DC Bus Fail / Fan Fail / Fuse Fail / Overload / Short-circuit /
Device Fail / Inverter Fail / Rectifier Fail / Bypass Fail, etc. h) Statistical
Data: No. of power failures / Transfers to Bypass / Total Running time, etc.
i) Mains Mode of Operation /Battery Mode of Operation / Bypass feeding
the load /UPS Fault /Battery charging and discharging, overload, battery
voltage and battery capacity. j) Audible Alarms : Mains Failure, Battery 26.2
Low Alarm, UPS Overload, Fault, Shutdown, Input Over, Under Voltage,
Output Over, Under Voltage, Battery Over, Under Voltage, Over Load and
short circuit, Over Temperature. The UPS should have QR code which
should contain drawing, test report OEM manual,Geo- Tag of
manufacturing location etc
a 100KVA (Each Power module shall be < 25 KVA) 26.2.7 1.00 Set 12,76,967.00 12,76,967.00 -
Digitally signed by DIWAKAR
SITC of LT switchgear panels suitable for 433 V, 3 phase, 4 wire, 50 Hz
power distribution system. The panel shall be Indoor, free standing, floor
mounting, sheet metal clad, cubicle, dead front, dust and vermin proof type
compartmentalised design fabricated out of 14 SWG CRCA sheet steel,
complete with colour coded, heat shrinkable PVC insulated, aluminium bus
bars and separate earth bus bar of adequate cross section through out the
length of the panel. The incoming and outgoing feeders shall be
accommodated in a fully segregated, modular multitier arrangement with - -
adequate size and distinct cable alley, bus bar alley/chamber. The panel
shall be complete with name plate, earthing, numbering, danger plate etc. as
per specifications and drawings as required. The panel shall withstand the
fault level of 50kA as per Single Line Diagram. The Panel shall also be
capable to communicate status like ON/OFF/ Trip through
Modbus/Ethernet for major component like ACB, MCCB, MCB &
Multifunation meters.
The Main LT Panel shall use all draw out type breakers suitable for 415 V
AC, 3 phase, 50 Hz, 3 phase 4 wire supply system. Panel shall have
Buscoupler switching, auto operation of incommer and bus coupler, auto
start of D.G. Sets, auto D.G. running by pre set timing, auto changeover etc
and having following incomming and outgoing Air Circuit - -
Breakers,microprocessor release for overload, short circuit, instantaneous &
earthfault protection with Current & Voltage metering & LCD display.
Air Circuit Breaker with microprocessor release ge metering & LCD display
, with ready to clsoe indicator, should have capability to communicate ON
/OFF/ Trip Status on Modbus/Ethernet and as per the detail specification of
ACB (Icu=Ics=Icw=65 KA (1 sec). MCCB, with microprocessor release
with LSIG protection functionand should not derate upto 50 decree
Centrigrate as per testing guideline as per IEC 60947-2 and all the ACB - -
upto 2500Amp ACB should have same frame size LCD display for fault
trip history, haivng current limiting feature, double break mechanism &
capability to communicate ON /OFF/ Trip Status on Modbus/Ethernet. (65
1 Nos. 630 Amp FP EDO ACB 65KA LSIG having S/C, E/F O/C
protection, LCD Display having specs as per attached annexture From
R,Y,B Phase indication Lamp with control MCB
On, Off, Trip Status Indication with control MCB
Inbuilt Zone Slelective Interlocking function
Multifunction Meter
Digitally signed by DIWAKAR
1 Nos. 250 Amp FP MCCB 50KA LSIG having S/C, E/F O/C protection,
LCD Display having specs as per attached annexture From
R,Y,B Phase indication Lamp with control MCB
On, Off, Trip Status Indication with control MCB
Inbuilt Zone Slelective Interlocking function
Multifunction Meter
1 Nos. 100 Amp FP MCCB 25KA LSIG having S/C, E/F O/C RPR
protection, LCD Display having specs as per attached annexture From
R,Y,B Phase indication Lamp with control MCB
On, Off, Trip Status Indication with control MCB
Inbuilt Zone Slelective Interlocking function
Multifunction Meter
1 Nos. 250 Amp FP ATS - -
1 Nos. 800 Amp FP busbars of aluminium alloy as per SLD. - -
1 Nos. 320 Amp FP busbars of aluminium alloy as per SLD. - -
7 Nos.100 Amp FP MCCB 25 KA, having specs as per attached annexture
R,Y,B Phase indication Lamp with control MCB - -
On, Off, Trip Status Indication with control MCB
METER PANEL+HVAC + Spare
7 Nos. 200 Amp FP MCCB 25 KA, having specs as per attached
annexture having
R,Y,B Phase indication Lamp with control MCB - -
On, Off, Trip Status Indication with control MCB
Officre FF + Spare
3 Nos. 63 Amp FP MCCB 25 KA
On, Off, Trip Status Indication with control MCB - -
Multifunction Meter
Short Circuit Breaking capacity should not less than 50KA. - -
RELAYS AS PER SLD - -
48 UPS Output Panel MR 1.00 Set 2,42,608.00 2,42,608.00
1 Nos. 200 Amp MCCB 25KA LSIG having S/C, E/F O/C protection,
R,Y,B Phase indication Lamp with control MCB
On, Off, Trip Status Indication with control MCB - -
Inbuilt Zone Slelective Interlocking function
Multifunction Meter
Digitally signed by DIWAKAR
1 Nos. 250 Amp FP busbars of aluminium alloy as per SLD. - -
6 Nos. 100 Amp FP MCCB 25 KA
On, Off, Trip Status Indication with control MCB - -
PDB+ACDB +Spare
Short Circuit Breaking capacity should not less than 16KA. - -
RELAYS AS PER SLD - -
49 Floor Power & HVAC Panel MR 4.00 Set 2,19,008.00 8,76,032.00
1 Nos. 200 Amp MCCB 25KA LSIG having S/C, E/F O/C protection,
R,Y,B Phase indication Lamp with control MCB
On, Off, Trip Status Indication with control MCB - -
Inbuilt Zone Slelective Interlocking function
Multifunction Meter
1 Nos. 250 Amp FP busbars of aluminium alloy as per SLD. - -
12 Nos. 63 Amp FP MCB 10 KA
On, Off, Trip Status Indication with control MCB - -
PDB+ACDB +Spare
Short Circuit Breaking capacity should not less than 16KA. - -
RELAYS AS PER SLD - -
50 Floor Light Panel & Floor UPS Panel MR 8.00 Set 1,59,595.00 12,76,760.00
1 Nos. 100 Amp MCCB 25 KA LSIG having S/C, E/F O/C protection,
R,Y,B Phase indication Lamp with control MCB
On, Off, Trip Status Indication with control MCB - -
Inbuilt Zone Slelective Interlocking function
Multifunction Meter
1 Nos. 125 Amp FP busbars of aluminium alloy as per SLD. - -
6 Nos. 32 Amp FP MCB 10 KA
On, Off, Trip Status Indication with control MCB - -
Short Circuit Breaking capacity should not less than 16KA. - -
RELAYS AS PER SLD - -
Digitally signed by DIWAKAR
Supply of aluminium conductor PVC insulated armoured served sheathed
cables 1100 Volts grade on cable tray as directed by engineer incharge
complete in all respect including The armouring of the cable shall be
properly connected with the earth conductor by clamps etc.
Supplying and making end termination with brass compression gland and
aluminium lugs for following size of PVC insulated and PVC sheathed /
XLPE aluminium conductor cable of 1.1 KV grade as required.
Laying and fixing of one number PVC insulated and PVC
53 sheathed / XLPE power cable of 1.1 KV grade of following size 10.8
on cable tray as required.
a Upto 35 sq. mm (clamped with 1mm thick saddle) 10.8.1 250.00 Meter 53.00 13,250.00 -
b Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) 10.8.2 200.00 Meter 109.00 21,800.00 -
Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat
d Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) 10.8.4 250.00 Meter 226.00 56,500.00 -
Providing, laying and fixing following dia RCC pipe NP2 class
(light duty) in ground complete with RCC collars, jointing with
cement mortar 1:2 (1 cement : 2 fine sand) including trenching
(75 cm deep) and refilling etc as required. 300mm Dia
Supplying and laying of following size DWC HDPE pipe ISI marked along
with all accessories like socket, bend, couplers etc.
conforming to IS 14930, Part II complete with fitting and cutting,
jointing etc. in the existing trench, complete as required
Grand Total (DSR+MARKET BASED ITEM) 2,60,37,494.71
Grand Total (DSR+MARKET BASED ITEM) 2,60,37,494.71
Grand Total (DSR+MARKET BASED ITEM) In Lac 260.37
Grand Total (DSR+MARKET BASED ITEM) In Lac 260.37
Digitally signed by DIWAKAR
Detailed Estimate Based On DSR-2025 With Cost Index & Market Rate
Project - Proposed Construction of Integrated Township at Chandrapura, Jharkhand.
Name Of Work -DE Nobili School Fire Detection Alarm & PA System Work
Rate as per D.S.R. 2025 MARKET BASED
Sr.No. Particulars Sch.No. Qty Unit Amount Rate Amount
Fire Alarm System :
Supplying, installation, testing & commissioning of main
control and indicating panel made out of 16 SWG MS sheet
to accommodate the following items duly powder coated in
approved colour with louvers for ventilation, locking
arrangement, audio and visual indication for fire alarm and
public address system, monitoring system including
connections, interconnections etc complete as required.
1 10 Zone panel for fire alarm system 28.1.10 1 NOS 75,339.00 75,339.00
250 Watt amplifier racks suitable for operation on 230V
AC/24V DC supply conforming to IEC-268-3 complete with all
accessories as required - 2 Nos.(one to act as standby)
Talk back master station with LED PTT (press to talk) push
button for operation on 230V AC/24 V DC supply conforming
to IEC-268 for simplex mode of operation/communication
suitable for 20 Nos.talk back unit -1 set.
Digitally signed by DIWAKAR
Annoucement control desk suitable for selection of different
zones selectively and ON ALL CALL switch with visual
indication etc. complete as required -1 set.
Amplifier change over switch for inter changing amplifier -1 No.
Monitor panel for loudspeaker complete with output
selector, ON/OFF switch, fuse, visual indications etc.
complete as required- 1 No.
Gooseneck microphone with stand and ON/OFF switch- 1 No.
Main ON/OFF switch, fuse indication lamps, DC and AC
voltmeters & ammeters, terminal blocks etc. complete as
required -1 set.
Battery charger trickle cum boost to take complete load of
fire alarm & PA system complete with all accessories
including providing & fixing of 2 nos.12 volt, 60 AH each
sealed maintenance free batteries -1 set.
Supplying, installation, testing & commissioning of addressable
fire control module complete as required.
Supplying, installation, testing & commissioning of manual call
boxes of MS construction in surface/recess with stainless steel
chain & hammer assembly complete with glass and push button
etc. as required.
Supplying, installation, testing & commissioning fire alarm
sounder with facility to make announcement, mounted in M.S.
4 box (16 SWG) with hinged cover plate & suitable for operation 28.1.6 12 NOS 600.00 7,200.00 -
with amplifier i/c line matching transformer etc. complete as
Digitally signed by DIWAKAR
Supplying, installation, testing & commissioning of fire fighter
telephone handset complete as required.
Supplying, installation, testing & commissioning talk back slave
station in surface/recess suitable for operation on simplex
6 mode complete with P.T.T. knob & speaker/microphone 28.1.8 2 NOS 963.00 1,926.00 -
enclosed in a M.S.(16 SWG)/ ABS box with break glass in front
etc. complete as required.
Supplying & laying of 2x1.5 sqmm fire survival armoured cable,
600/1000V rated with annealed copper conductor having glass
mica fire barrier tape covered by an extruded layer of Cross
Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH
inner bedding, steel wire armouring & LSZH outer sheath
complete as required.
GRAND TOTAL (PWD+DSR+MARKET BASED ITEM) 2,81,769.00
GRAND TOTAL (PWD+DSR+MARKET BASED ITEM) 2,81,769.00
GRAND TOTAL (PWD+DSR+MARKET BASED ITEM) IN LAC 2.82
GRAND TOTAL (PWD+DSR+MARKET BASED ITEM) IN LAC 2.82
Digitally signed by DIWAKAR
Detailed Estimate Based On DSR-2025 With Cost Index & Market Rate
Project - Proposed Construction of Integrated Township at Chandrapura, Jharkhand.
Name Of Work -DE Nobili CCTV Surveillance System Work
Rate as per D.S.R. 2025
Sr.No. Particulars Sch.No. Qty Unit Amount Rate Amount
Supplying and fixing of following sizes of medium class PVC conduit
along with accessories in surface/recess including cutting the wall and
making good the same in case of recessed conduit as required. 25mm
Grand Total (DSR+MARKET BASED ITEM) 3,62,880.00
Grand Total (DSR+MARKET BASED ITEM) 3,62,880.00
Grand Total (DSR+MARKET BASED ITEM) 3,62,880.00
Grand Total (DSR+MARKET BASED ITEM) 3,62,880.00
Digitally signed by DIWAKAR
Detailed Estimate Based On DSR-2025 With Cost Index & Market Rate
Project - Proposed Construction of Integrated Township at Chandrapura, Jharkhand.
Name Of Work -DE Nobili School Lift Work
Rate as per P.A.R. 2025
Sr.N Rate as per
Particulars Sch.No. Qty Unit Amount Rate Amount
Supply Installation Testing and Commissioning of lift
with power operated doors and AC variable voltage and
variable frequency controls having speed of minimum
1.5m/sec as per CPWD specifications.
Grand Total (DSR+MARKET BASED ITEM) 21,55,000.00
Grand Total (DSR+MARKET BASED ITEM) 21,55,000.00
Grand Total (DSR+MARKET BASED ITEM) 21,55,000.00
Grand Total (DSR+MARKET BASED ITEM) 21,55,000.00
Digitally signed by DIWAKAR
Detailed Estimate Based On DSR-2025 With Cost Index & Market Rate
Project - Proposed Construction of Integrated Township at Chandrapura, Jharkhand.
Name Of Work -DE Nobili School EPABX & AV System Work
Rate as per D.S.R. 2025 MARKET BASED
Sr.No. Particulars Sch.No. Qty Unit Amount Rate Amount
A EPABX SYSTEM
1 S/f of I/O Boxes Krone connectors ,with connection etc. MR -
2 Wiring of Jelly Filled telephone Cable in existing pipe for system with connection. MR -
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories
like socket, bend, couplers etc.
conforming to IS 14930, Part II complete with fitting and cutting,
jointing etc. in the existing trench, complete as required. 100mm Dia
Grand Total (DSR+MARKET BASED ITEM) 1,10,730.00
Grand Total (DSR+MARKET BASED ITEM) 1,10,730.00
Grand Total (DSR+MARKET BASED ITEM) 1,10,730.00
Grand Total (DSR+MARKET BASED ITEM) 1,10,730.00
Digitally signed by DIWAKAR
Detailed Estimate Based On DSR-2025 With Cost Index & Market Rate
Project - Proposed Construction of Integrated Township at Chandrapura, Jharkhand.
Name Of Work -DE Nobili School AV System Work
Rate as per D.S.R. 2025 MARKET BASED
Sr.No. Particulars Sch.No. Qty Unit Amount Rate Amount
A EPABX SYSTEM
Conference hall: supplying, installation, testing and commissioning of audio
visual/conference system (Rate applicable on carpet area of Hall only)
Grand Total (DSR+MARKET BASED ITEM) 10,50,659.85
Grand Total (DSR+MARKET BASED ITEM) 10,50,659.85
Grand Total (DSR+MARKET BASED ITEM) In Lac 10.51
Grand Total (DSR+MARKET BASED ITEM) In Lac 10.51
Digitally signed by DIWAKAR
Detailed Estimate Based On DSR-2025 With Cost Index & Market Rate
Project - Proposed Construction of Integrated Township at Chandrapura, Jharkhand.
Name Of Work -DE Nobili School Lift Work
Rate as per D.S.R. 2025
Sr.N Rate as per
Particulars Sch.No. Qty Unit Amount Rate Amount
Supplying Installation, Testing and Commissioning of
on-grid Solar Photovoltaic Power Plant conforming to
various applicable standards BIS, IEC, MNRE
guidelines, the Central Electricity Authority
Regulations and CPWD Specifications as amended up
to date, consisting of Mono/Poly Crystalline silicon
1 solar cells module, net metering facility, necessary
control, protections, earthing, cabling, mounting
structure, junction boxes, power conditioning units,
Real time online web interfaced Data Monitoring
System, Distribution panels, grid connecting
arrangement, conduits, pipes, cable trays and other
accessories etc. as required.
a) High Energy Efficiency Solar Photovoltaic Module of
capacity 330 Wp or above, manufactured in India,
conforming to IS 14286/IEC 61215, IS/IEC 61730-
Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic
Module conversion efficiency shall not be less than
23% at STC with temperature coefficient of Pmax
better than -0.30% per 0C. PV modules used in solar
power plants/ systems must be warranted for their
output peak watt capacity, which should not be less
than 90% at the end of 10 years and 80% at the end of
25 years. Solar Modules shall be designed to operate
Digitally signed by DIWAKAR
in relative humidity upto 100% with temperature
between -10 0C and +85 0C. Further, each PV module
used in any solar power project must have Radio
frequency identification tag with information such as
name of manufacturer, month and year of
manufacturing, country of origin (separately for Solar
cell and module), I-V curve, Unique Serial No and
Model No of the module, Wattage, Im, Vm and FF,
name of test lab issuing IEC certificate.
b)Power Conditioning Unit (PCU) of 350-800 V DC
Input voltage range and 415 V AC, three phase, 4
wire, 50Hz +/- 2.5 Hz, output voltage suitable to
generate AC with a variation of 10% at nominal
voltage. Power with efficiency not less than 97%, total
harmonic distortion less than 3% and suitable for
ambient temperature from 0 to 50 0C, Minimum IP-65
for outdoor and Minimum IP 21 for indoor, Built-in
meter and data logger, MPPT, switching devices
IGBT/MOSFETs and controller Microprocessor /DSP.
PCU/inverter shall be capable of complete automatic
operation including wake-up, synchronization &
shutdown. The PCU shall be able to withstand
unbalanced load conforming to IEC standard with
shutdown/standby mode. It must be provided with grid
islanding along with manual disconnect pole isolation
switch besides automatic disconnection. Minimum
protections: Mains Under / Over Voltage, Over current,
Over/Under grid frequency, Over temperature, Surge
voltage induced at output due to external source,
Short-circuit, Lightening, Anti Islanding (for grid synch.
Mode) and other protections as per applicable
standards. LCD/LED display of minimum parameters:
DC input voltage, DC current, AC Voltage and current
(all 3 phases, in case of 3 phase), Instantaneous &
cumulative AC output power, Daily DC energy
produced and other parameters applicable standard.
Communication interface RS 485 / RS 232.
Digitally signed by DIWAKAR
c) Module mounting structure: The roof top solar plant
generation units shall be installed by using supporting
Aluminium/Galvanized MS structure (mass of zinc
coating shall be as per IS4759 ) having minimum head
room clearance of 2.4 meter above the terrace level /
ground level. The mounting structure would be
designed to sustain wind load and seismic parameter
of the site of installation. All the structure shall be
design as per applicable BIS code and the material
shall also confirm the applicable BIS Code. Structural
material shall be corrosion resistant and electrolytically
compatible with the materials used in the module
frame, its fasteners, nuts and bolts. The suitable
arrangements for maintenance and cleaning shall be
d) Real time online web interfaced Data Monitoring
System complete with accessories for various
parameters such as Solar Irradiance, temperature, AC
Output Voltage and current, Output Power, Power
factor, DC Input Voltage and Current, Time Active,
Time disabled, Time Idle, Power produced and other
parameters as per standard practices.
e) Array junction box & Main junction box with IP 65
protection and termination arrangement for incoming
and outgoing cable along with glands, lugs and other
accessories etc. as required. Each junction box shall
be made of GRP/FRP/Powder Coated Aluminium /cast
aluminium alloy with full dust, water & vermin proof
arrangement with High quality Suitable capacity Metal
Oxide Varistors(MOVs) (semiconductor diode with
resistant applied voltage)/ surge arrestors and suitable
Reverse Blocking Diodes, isolation switches isolate
the DC input to Inverter, copper bus bar etc.
Digitally signed by DIWAKAR
f) Lightning, surge voltage protection, earthing
protection and grid islanding.
g) Cables: Connections & Interconnections by
required size IR/UV protected XLPE insulated copper
conductor 1.1 kV grade armored power and control
cables(ISI Marked) along with supplying & fixing of
necessary channel/conduit, GI cable trays, supports,
lugs, thimble and other accessories etc. as required.
h) DC Distribution Board And AC Distribution Panel
Board: IP65, free standing, metal cladded, having
copper bus bar, having required protection and control
gears, connection-interconnection, etc. as required.
Grand Total (DSR+MARKET BASED ITEM) 27,14,000.00
Grand Total (DSR+MARKET BASED ITEM) 27,14,000.00
Grand Total (DSR+MARKET BASED ITEM) 27,14,000.00
Grand Total (DSR+MARKET BASED ITEM) 27,14,000.00
Digitally signed by DIWAKAR
Name of Project : CONSTRUCTION OF INTEGRATED TOWNSHIP AT CHANDRAPURA, JHARKHAND
Final Abstract (fire fighting)
Amount as per Amount as per Amount as per
DSR -2023 Items DSR -2025 Items Non -Scheduled
(A) (B) Items (C)
S. No. Description
I. FIRE PUMPS AND HYDRANT WORKS 9,22,954.00 -
II. PIPING FOR FIRE FIGHTING SYSTEM 31,416.78 11,69,212.00 -
III FIRE EXTINGUSHER AND HYDRANT 7,47,162.18
Grand Total A+B 28,70,744.96
Grand Total A+B 28,70,744.96
Digitally signed by DIWAKAR
DETAILED ESTIMATE
S. NO. (FIRE DSR-
2025/NS) DESCRIPTION UNIT QTY RATE AMOUNT (IN RS.)
SUBHEAD-I(A): FIRE PUMPS AND HYDRANT WORKS (NON SCHEDULED ITEMS)
1 27.4 FIRE ROOF PUMPS - ELECTRICAL
Supplying, installation, testing and commissioning of electric driven
terrace pump suitable for automatic operation and consisting of
following, complete in all respects, as required: (Terrace Pump)
Horizontal type, multistage, centrifugal pump of cast of iron body and
bronze impeller with stainless steel shaft, mechanical seal conforming to
Suitable HP squirell cage induction motor TEFC type suitable for
operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of
protection for enclosure, horiziontal foot mounted type with Class-'F'
insulation, conforming to IS-325.
M.S fabricated, common base plate, coupling, coupling guard,
foundation bolts etc. as required.
Suitable cement concrete foundation duly plastered and with anti
vibration pads.
Providing & fixing of pressure switch in M.S. pipe line including
2 27.22 connection etc. as required. Each 1 1,670.00 1,670.00
Digitally signed by DIWAKAR
3 27.20 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS
sheet, 1200 mm in height with air release valve on top and flanged
connection to riser, drain arrangement with 25 mm dia gun metal wheel
valve with required accessories, pressure gauge and paintingwith
synthetic enamel paint of approved shade as required. Each 1 19,402.00 19,402.00
4 Supply, installation, testing, trial run and commissioning of hydrants all
complete as required and as approved
Fire Hose Cabinet
Supplying and fixing single headed internal hydrant valve with
instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast
iron wheel ISI marked conforming to IS 5290 (Type -A) with blank
5 27.9 Gunmetal/Stainless Steel cap and chain as required :
27.9.2 Single headed Stainless steel Each 26 6,632.00 1,72,432.00
Supplying and fixing first-aid Hose Reel with MS construction spray
painted in post office red, conforming to IS 884 complete with the
6 27.17 following asrequired.
20 mm nominal internal dia water hose thermoplastic (Textile
reinforced) type -2 as per IS: 12585
20 mm nominal internal dia gun metal globe valve & nozzle.
Drum and brackets for fixing the equipmets on wall.
Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia
male and female couplings duly bound with GI wire, rivets etc.
7 27.16 conforming to IS 636 (type-A) as required :
27.16.2 Stainless steel (Grade 304) Each 54 4,667.00 2,52,018.00
Digitally signed by DIWAKAR
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm
nominal internal diameter size nozzle conforming to IS 903 suitable for
instantaneous connection to interconnect hose pipe coupling as required
27.18.2 Stainless steel (Grade 304) Each 26 3,402.00 88,452.00
Supplying and fixing orifice plate made out of 6 mm thick stainless steel
(Grade 304) with orifice of required size to be fitted between flange &
landing valve of external and internal hydrants to reduce pressure at the
outlet to the level of 3.5 kg/cm2 complete as required. Each 26 1,436.00 37,336.00
Supplying and fixing of fire brigade connection of cast iron body with gun
metal male instantaneous inlet couplings complete with cap and chain as
reqd. for suitable dia MS pipe connection conforming to IS 904 as
11 27.19 required :
TOTAL C/F TO SUMMARY 9,22,954.00
Digitally signed by DIWAKAR
SUBHEAD-I (B): PIPING FOR FIRE FIGHTING SYSTEM
Excavating trenches of required width for pipes, cables, etc including
excavation for sockets, and dressing of sides, ramming of bottoms, depth
upto 1.5 m including getting out the excavated soil, and then returning
the soil as required, in layers not exceeding 20 cm in depth including
consolidating each deposited layer by ramming, watering, etc. and
12 disposing of surplus excavated soil as directed, within a lead of 50 m :
All kinds of soil
2.10.1.2 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. Cum 1 376.91 376.91
Civil 4.5 Providing and fixing up to floor five level precast cement concrete string
or lacing courses, copings, bed plates, anchor blocks, plain window sills,
shelves, louvers, steps, stair cases, etc. including hoisting and setting in
position with cement mortar 1:3 (1 Cement : 3 coarse sand), cost of
required centering, shuttering and finishing smooth with 6mm thick
cement plaster 1:3 (1 Cement : 3 fine sand) on exposed surfaces
1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm
Civil 4.5.1 nominal size). Cum 1.00 10815.49 10,815.49
Digitally signed by DIWAKAR
Constructing masonary chamber 90 x 90 x100 cm. inside with 75 class
designation brickwork in cement mortar 1:5 ( 1 cement : 5 fine sand) for
sluice valve with CI surface box 100 mm top dia. 180 mm bottom dia.
And 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix ( 1
cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
necessary excavation foundation concrete 1 :5 :10 (1 cement : 5 fine
sand : 10 graded stone aggregate 40 mm nominal size and inside
plastering with 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with
a floating coat of neat cement complete as per standard design with FPS
Providing and fixing C.I. double acting air valves of approved quality with
bolts, nuts, rubber insertions etc. complete ( The tail pieces, tapers etc. if
15.0 Civil 18.59 reqd. will be paid separately)
TOTAL C/F TO SUMMARY 31,416.78
Digitally signed by DIWAKAR
SUBHEAD-II (B):PIPING FOR FIRE FIGHTING SYSTEM
Supplying, fixing, testing & commissioning of double flanged sluice valve
of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI
marked complete with nuts, bolts, washers, gaskets and conforming to IS
16 27.12 780 of following sizes as required :
Providing, installation, testing and commissioning of stainless steel
Ystrainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet
17 27.15 with 3 mm dia holes with stainless steel flange.
Providing, installation, testing and commissioning of non-return valve of
following sizes confirming to IS: 5312 complete with rubber gasket, GI
18 27.14 bolts, nuts, washers etc.as required :
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6
rating with bronze/gunmetal seat duly ISI marked complete with nuts,
bolts, washers, gaskets conforming to IS 13095 of following sizes as
19 27.11 required :
Digitally signed by DIWAKAR
Supplying and fixing of fire brigade connection of cast iron body
with gun metal male instantaneous inlet couplings complete with
20 27.19 cap and chain as reqd. for suitable dia MS pipe connection
conforming to IS 904
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe
conforming to IS 3589/IS:1239 including Welding, fittings like elbows,
tees, flanges,tapers, nuts bolts, gaskets etc. and fixing the pipe on the
wall/ceiling with suitable clamp/support frame and painting with two or
more coats of synthetic enamel paint of required shade complete as
21 27.7 required : (Above Ground)
Threaded joint upto 50mm diameter pipe.
Welded joint above 50mm diameter pipe.
c 27.7.8 150 mm nominal bore (class C) Rm 10 4,299.00 42,990.00
d 27.7.7 100 mm nominal bore (class C) Rm 260 3,077.00 8,00,020.00
e 27.7.6 80 mm nominal bore (class C) Rm 10 2,277.00 22,770.00
g 27.7.4 50 mm nominal bore (class C) Rm 7 1,557.00 10,899.00
J 27.7.1 25 mm nominal bore (class C) Rm 7 920.00 6,440.00
TOTAL C/F TO SUMMARY 11,69,212.00
Digitally signed by DIWAKAR
SUBHEAD- III (B): FIRE EXTINGUSHER AND HYDRANT (NON SCHEDULED ITEMS)
Providing and fixing carbon-di-oxide type fire extinguishers consisting of
welded M.S. cylindrical body, internal discharge tube, discharge nozzle,
suspension bracket, conforming to IS 2878, finished externally with red
enamel paint and fixed to wall with brackets complete with internal
1 NS-1 charges.
Providing & Fixing of stored pressure Fire Extinguisher ABC powder type
(Mono Ammonium Phosphate Powder) Magnetic Pressure Gauge having
the facility to check at site, Discharge Time less than 9 Secs, Controllable
discharge mechanism, Range minimum 4 Meters, applicable on Class
A,B,C and electrically started Fire, A Rating- 21A, B Rating 55B as per BS
EN-3 BIS 15683 marked, Can Construction : Deep drawn & CO2 Mig
welded, Valve Construction : Forging & Machining, Internal Coating of
Can : Epoxy Powder coating, External Coating ofCan : Epoxy Polyster
Powder coating, Sheet metal thickness : 1.60MM, Helium LeakDetection
2 NS-2 Tested, Warranty.
Providing and fixing angle iron (40 mm x 40 mm x 5 mm) MS door frame
900x2100 door capable of accommodating fire hose reel, landing valve,
hose pipes, fittings & accessories. The door shall have a front glass with
lock and key arrangement & shall be painted with post office red colour
(approval shall be taken on the basis of submitted sample before
ordering) Cost of fire extinguishers not included in item rate. (Liasioing
with civil contractor for making 900x600x2100 Recessed type mansoary
3 NS-3 box (by civil contractor). Each 26 13,524.56 3,51,638.47
Digitally signed by DIWAKAR
4 NS-4 Providing and fixing of Fire Axe Each 26 644.03 16,744.69
5 Providing, fixing, testing and commissioning of full way level
operated forged brass ball valve of brass body with forged brass
hard chrome plated steel ball tested to a pressure not lass than 15
kg/sq.cm with threaded/flanged complete with nuts, bolts,
gaskets, washers etc. as required complete as per direction of
NS-5 Engineer incharge.
6 NS-6 ROOF FIRE PANELS:
Supply, installation, testing and commissioning of followingintegrated,
cubicle type,dead front, extensible, sheet steel control panel. The panel
shall be suitable for 440 volts, 50 cycles, 4 wire supply Item 1 55,835.33 55,835.33
The following components and accessories shall be mounted with ineach
One no 100 amps TP incoming MCCB with the following:
0-500 volts 96 x96 square mm voltmeter with slector switch and control
0-100 amps 96 x96 square mm ammeter with CT's and slector switch- 1
Including all elecal works
Phase indicating lamp with toggle switches.
Indication lamps for ON/OFF/TRIP status
Outgoing Feeders / Starters as below:
100 ATP MCCB with star / delta as starter suitable for 30 HP motor for
Downcomer Pump - 1 Set
Provision in control panel to connect flow switch for autmatic operation
of roof fire pumps.
TOTAL C/F TO SUMMARY 7,47,162.18
Digitally signed by DIWAKAR
CONSTRUCTION OF INTEGRATED
No. NSI Description Unit QTY NSI RATE SI Rate NSI AMOUNT
HVAC ESTIMATE FOR DVC SCHOOL BLOCK, JHARKHAND
BILL OF QUANTITIES
1) Sub Head 'A' - Machinery INR 8,13,549 -
2) Sub Head 'C' - Ducting & Grilles INR 6,33,500 2,56,607
3) Sub Head 'D' - HVAC Electric Work INR 3,58,857 1,77,400
Sub Total Estimated Cost INR 18,05,906 4,34,007
Grand Total Estimated Cost INR 22,39,913
Grand Total Estimated Cost INR 22,39,913
PART - I : AIR CONDITIONING SYSTEM
SUB HEAD - "A" : MACHINERY
13 NSI Axial Flow Fan For smoke Exhaust
Supply, installation, testing and commissioning of ceiling mounted Tube Axial flow
fans with adjustable pitch blade, MS / GI long casing (2mm thick up to 800 mm dia
fan, 3 mm thick from 900 to 1250 mm dia & 4 mm thick above 1300 mm dia) , cast
aluminium alloy impeller complete with TEFC (Motor Efficiency IE3) Sq. Cage
Induction motor suitable for 415 volts ± 10%, 50Hz ± 3 %, three phase A.C supply
with support, mountings, vibration isolators, fire retardant flexible canvass
connector 150 mm deep (Inlet & Outlet as required), bird screen (Inlet & Outlet as
required) etc. & of following capacity. The complete fan along with motor shall be
suitable for 250 °C temperature rated for 2 hours. Fan outlet velocity shall be limited
to maximum of 16 m/sec. Fan & Fan motor KW given below are for guideline & actual
Dia / KW shall be as per manufacturer selection based on maximum 16 m/sec outlet
Axial Fan shall be AMCA certified for Air and Sound performance in accordance to
AMCA 210 and AMCA 300. Complete certified model appearing on AMCA web site
shall be accepted. Complete Fan shall be tested and approved by UL in accordance
with "Power Ventilators for
Smoke Control Systems" for Class- H Motor
Digitally signed by DIWAKAR
No. NSI Description Unit QTY NSI RATE SI Rate NSI AMOUNT
Manufacturer shall furnish AMCA Test Certificate for air & sound performance along
with UL fire test certificate (Latest) for each fan sourced from that particular factory.
b) 15,000 CFM (20mm st. pr, 1000 mm Dia Axial Fan, 3.7 KW, 1450 RPM Fan Motor,
14 Axial Flow Fan For PRESSURIZATION & MAKE-UP AIR
Supply, installation, testing and commissioning of ceiling mounted Tube Axial flow
fans with adjustable pitch blade, MS / GI long casing (2mm thick up to 800 mm dia
fan, 3 mm thick from 900 to 1250 mm dia & 4 mm thick above 1300 mm dia) , cast
aluminium alloy impeller complete with TEFC (Motor Efficiency IE3) Sq. Cage
Induction motor suitable for 415 volts ± 10%, 50Hz ± 3 %, three phase A.C supply
with support, mountings, vibration isolators, fire retardant flexible canvass
connector 150 mm deep (Inlet & Outlet as required), bird screen (Inlet & Outlet as
required) etc. & of following capacity. The complete fan along with motor shall be
suitable for 250 °C temperature rated for 2 hours. Fan outlet velocity shall be limited
to maximum of 16 m/sec. Fan & Fan motor KW given below are for guideline & actual
Dia / KW shall be as per manufacturer selection based on maximum 16 m/sec outlet
Axial Fan shall be AMCA certified for Air and Sound performance in accordance to
AMCA 210 and AMCA 300. Complete certified model appearing on AMCA web site
shall be accepted.
Complete Fan shall be tested and approved by UL in accordance with "Power
Ventilators for
Smoke Control Systems" for Class- F Motor.
Manufacturer shall furnish AMCA Test Certificate for air & sound performance along
fire test certificate (Latest) for each fan sourced from that particular factory.
a) 15,000 CFM (25mm st. pr, 900 mm Dia Axial Fan, 3.7 KW, 1450 RPM Fan Motor,
17) NSI Fan Section to for Exhaust / Supply
Digitally signed by DIWAKAR
No. NSI Description Unit QTY NSI RATE SI Rate NSI AMOUNT
Supply, installation, testing and commissioning of factory fabricated Double
Skinned fan section unit floor mounted type fabricated out of extruded
aluminium section with 0.6mm pre-plasticized / pre-coated Galvanised steel sheet
outside & 0.6 mm plain Galvanised steel sheet inside with blower, blower section
and blower motor TEFC (Motor Efficiency IE3) type suitable for operation on 415
volts ± 10%, 50 Hz ± 5% AC supply, belt drive package.
a) 2,500 CFM, 1 x 3750 mm Dia. Fan, 1 x 3.7 Kw Fan Motor, 35 mm St. Pressure, IE-3
motor For Exhaust
4,500 CFM, 1 x 450 mm Dia. Fan, 1 x 3.7 Kw Fan Motor, 35 mm St. Pressure, IE-3
motor For Exhaust
Grand Total of Sub Head ''A'' AC Machinery 8,13,549 -
Grand Total of Sub Head ''A'' AC Machinery 8,13,549 -
SUB HEAD - "B" : PLUMBING
SUB HEAD - "C" : DUCTING , GRILLES & INSULATION
20) DSR-2022 RECTENGULAR / SQUARE DUCTING (FACTORY FABRICATED)
Supplying, installation, balancing and commissioning of factory fabricated GSS
sheet metal rectangular/ round ducting complete with neoprene rubber
gaskets, elbows, splitter dampers, vanes, hangers, supports, bends, transitions,
reducers, end caps, collars etc as required complete in all respect in 227 DELHI
SCHEDULE OF RATES (E&M)-2025confirmation to IS : 655 and approved drawings
and specifications of following sheet thickness complete as required.
a) 30.11.1.1 24 G (Thickness 0.63mm sheet) SMT 75 1,191 - 89,325
c) 30.11.1.3 20 G (Thickness 1.00mm sheet) SMT 0 1,488 - -
d) 30.11.1.4 18 G (Thickness1.25mm sheet) SMT 0 2,013 - -
21) DSR-2025 RECTANGULAR / SQUARE DUCTING (SITE FABRICATED)
Digitally signed by DIWAKAR
No. NSI Description Unit QTY NSI RATE SI Rate NSI AMOUNT
Supplying, installation, balancing and commissioning of fabricated at site GSS
sheet metal rectangular/ round ducting complete with neoprene rubber gaskets,
elbows, splitter dampers, vanes, hangers, supports, bends, transitions, reducers, end
caps, collars etc as required complete in all respect in confirmation with IS : 655 and
approved drawings and specifications of following sheet thickness complete as
required. ncluding nut bolt fastner,sealent (neoprene gasket),access door etc.
a) 30.12.2.1 24 G (Thickness 0.63mm sheet) SMT 0 1,213 - -
b) 30.12.2.2 22 G (Thickness 0.80mm sheet) SMT 0 1,415 - -
c) 30.12.2.3 20 G (Thickness 1.00mm sheet) SMT 0 1,851 - -
d) 30.12.2.4 18 G (Thickness1.25mm sheet) SMT 0 2,063 - -
22) DSR-2025 VOLUME CONTROL DUCT DAMPER
a) 30.13 Supply, installation, testing and commissioning of GI volume control duct damper
complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as SMT 0 7,580 - -
per specifications.
23) DSR-2025 FIRE DAMPER
a) 30.14.1 Supply, installation, testing and commissioning of Motorized (ON-OFF Type) duct
mounted GI volume control damper with enthalpy sensor and necessary control wire
for integration within AHU room complete with neoprene rubber gaskets, nuts, bolts, SMT 0 18,377 - -
screws linkages, flanges etc in confirmation to SMACNA/IS and as per
specifications complete etc. as required.
25) DSR-2025 SUPPLY AIR GRILLES WITH VCD
a) 30.15 Supplying, Fixing, installation, testing and commissioning of powder coated extruded
aluminium Supply Air Grills with aluminium volume control dampers in confirmation SMT 4 9,623 - 38,492
to SMACNA/IS and as per specifications complete etc. as required.
26) DSR-2025 RETURN AIR GRILLES WITHOUT VCD
Digitally signed by DIWAKAR
No. NSI Description Unit QTY NSI RATE SI Rate NSI AMOUNT
a) 30.16 Supply & fixing of powder coated extruded aluminium Return Air Grills with louvers
but without volume control dampers as per specifications.
27) DSR-2025 SUPPLY AIR DIFFUSER WITH VCD
a) 30.17 Supplying, Fixing, installation, testing and commissioning of supply air diffusers of
powder coated aluminium with aluminium volume control dampers with anti smudge
ring & removable core in confirmation to SMACNA/IS and as per specifications
complete etc. as required.
28) DSR-2025 RETURN AIR DIFFUSER WITHOUT VCD
a) 30.18 Supplying, Fixing, installation, testing and commissioning of Return air diffusers of
powder coated aluminium without volume control dampers with anti smudge ring &
removable core in confirmation to SMACNA/IS and as per specifications complete
etc. as required.
29) FRESH / EXHAUST LOUVER WITH BIRD SCREEN
a) NSI Supplying & fixing of 18 G thick Aluminium extruded powder coated Fresh /
Exhaust air weather protected louvers with bird screen type (with Aluminium
frames if required) for ventilation with 12G GI wire mesh as per specification and
sizes will be as per tender drawing mentioned.
30) DSR-2025 FLEXIBLE DUCT
Supply, installation, testing & commissioning of thermal insulated flexible duct of
following sizes duly supported at regular interval as per site requirement etc.
complete as required as per specifications.
INSULATION WORKS
31) 30.23 DUCT INSULATION (NITRILE RUBBER)
Digitally signed by DIWAKAR
No. NSI Description Unit QTY NSI RATE SI Rate NSI AMOUNT
Supplying and fixing of following thickness duly laminated aluminium foil of mat finish
closed cell Nitrile rubber (Class"O") insulation on existing duct after applying suitable
adhesive for Nitrile rubber. Thejoints shall be 50 mm wide and 3 mm thick self
adhesive nitrile rubber tape insulation complete as per specifications and as
30.23.1 19 mm thick for Supply / Return Air Duct SMT 0 810 - -
30.23.2 25 mm thick for Supply Air Duct exposed SMT 0 1,033 - -
32) DSR-2025 DUCT ACOUSTIC INSULATION
30.21 Supplying and fixing of acoustic lining of supply air duct and plenum with 25 mm thick
resin bonded glass wool having density of 32 kg/m³, with 25 mm X 25 mm
GI section of 1.25 mm thick, at 600 mm centre to 229 DELHI SCHEDULE OF RATES
(E&M)-2025centre covered with Reinforced Plastic tissue paper and 0.5 mm thick SMT 0 890 - -
perforated aluminium sheet fixed to inside surface of ducts with cadmium plated nuts,
bolts, stick pins, CPRX compound in confirmation to SMACNA/IS and as per
specifications complete etc. as required.
33) DSR-2025 ACOUSTIC INSULATION OF AHU ROOM
30.22 Supplying, fixing acoustic lining on wall and ceiling of AHU rooms with 50mm thick,
density 32 kg/cu.m resin bonded glass fiber insulation friction fixed in 610mm x
610 mm frame work made of 25X50X50X50X25 mm made out of 0.6mm thick GI
sheet U shaped channel and covered with reinforced fiber glass tissue and
finished with 0.80 mm perforated aluminium sheet etc. complete as required and as
per specifications.
UNDED DECK INSULATION
34) NSI Supplying & fixing of under deck insulation with 75 mm thick XPS with overlapping
edge of R Value per inch as 5.15 with the help of woodscrews, rowl plug & dash
fasteners, washers etc complying with the process and specification as given in
tender specification. It shall conform to DBR & NIIT specification. Note:- Overdeck SMT 700 905 - 6,33,500 -
insulation shall be done by civil agency. If it is partly missed anywhere then
Underdeck insulation shall be considered and applied. The quantity given above is
just for reference.
Digitally signed by DIWAKAR
No. NSI Description Unit QTY NSI RATE SI Rate NSI AMOUNT
Grand Total of Sub Head ''C'' AC AIR DISTRIBUTION 6,33,500 2,56,607
Grand Total of Sub Head ''C'' AC AIR DISTRIBUTION 6,33,500 2,56,607
SUB HEAD - "D" : ELECTRICAL PANEL & DISTRIBUTION
36) NSI Panel-1 (Terrace Floor / pressurization panel)
Incoming(1 Nos):
125 Amp 4-Pole MCCB, 50kA with thermal magnetic based O/L, S/C and E/F
Multifunction meter and 250/5A, CL-1, 10VA CTs and 2A control MCB.
Sets of phase indicating lamps with 2A control MCBs.
400A, TPN Aluminium, colour coded bus bars suitable for 415V, 50Hz. (After
(a) 6 Nos-3 Pole MCBs 25 A
(d) 2 Nos-4 Pole MCCBs 63 A Spare Set 1.00 93,595 - 93,595 -
36a) NSI Supply of Starter panels ((Terrace Ventilation / pressurization panel-2B):
Supply, installation, testing & commissioning of the following starters in a sheet
metal enclosure complete as required and as per site conditions:
Digitally signed by DIWAKAR
No. NSI Description Unit QTY NSI RATE SI Rate NSI AMOUNT
DOL/Star Delta Starter of following rating with Auto/ Manual selector switch,
MPCB/MCCB, over load relay, single phasing preventor, ON/OFF/ Trip indication
lamps, Ammeters with CTs, ON/OFF push Buttons, contractor and suitable No. of
Potential free contacts for remote / local operations, indication, interlocking with
Fire Alarm panel and Building Management system. (Starter shall have
MPCB/MCCB in the incomer as per type -2 coordination for fuseless type feeders.)
upto 3.7 kW DOL Starter Nos. 6.00 25,919 - 1,55,514 -
5.6 kW DOL Starter Nos. 0.00 28,798 - - -
7.5 kW Star Delta Starter Nos. 0.00 43,198 - - -
1) Provision for VFD shall be provided in the starter panels.
37) NSI Power & Control Cabling
A) Supply, laying, testing and commissioning of power and control cabling as per
specification given in the tender. Power cabling of XLPE insulated Aluminium
conductor armoured cables of 1.1 KV Grade including cable end termination with
brass compression glands & aluminium lugs etc as per specification. It shall conform
to DBR & NIIT specification.
a) i) For VRV ODU
1 x 3 C x 25 Sq. mm alluminium cable RMT. 0 1,227 - - -
b) viii) For Fan Motor - Up to 3.70 Kw
c) ix) For Fan Motor - Up to 5.6 Kw
Digitally signed by DIWAKAR
No. NSI Description Unit QTY NSI RATE SI Rate NSI AMOUNT
d) x) For Fan Motor - 7.46 Kw
e) xi) For Fan Motor - 9.33 / 11.19 Kw
f) xii) For AHU Fan Motor - 15.00 / 18.65 Kw
g) xiii) For HRW & Humidifier of 1.50 / 3.00 Kw
h) xiv) For main Building panel to floor Panel
xv) For Single Phase Equipment (Note: All single phase equipment power
o) supply will be catered by AC socket Provided by the electrical contractor)
1 x 3C x 1.5 Sq. mm Copper Flexible Cable RMT. 0 95 - - -
1 x 3C x 4.0 Sq. mm Copper Flexible Cable RMT. 0 279 - - -
B) Control cabling (PVC insulated Copper conductor of 1.1 KV Grade armoured
p) cable). It shall conform to DBR & NIIT specification.
Digitally signed by DIWAKAR
No. NSI Description Unit QTY NSI RATE SI Rate NSI AMOUNT
q) C) Transmission & Control Wiring For VRV / VAV System
Providing & fixing of control cum trans-mission wiring of copper between indoor
and out door unit in 25 mm PVC Conduit. It shall conform to DBR & NIIT
38) DSR-2022 Earthing Strip / Wires as per specs.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections
etc. as required.
iv) Supply & laying of 6 SWG GI wire or in recess for loop earthing as required. It
shall conform to DBR & NIIT specification.
v) Rubber mat 1000 mm. Wide to withstand 1.1 KV dielectric strength as per latest IS
15652-2006. It shall conform to DBR & NIIT specification.
39) DSR-2022 Cable Tray
Supplying and installing following size of perforated Hot Dipped Galvanised Iron
cable tray (Galvanisation thickness not less than 50 microns) with perforation
not more than 17.5%, in convenient sections, joined 26 DELHI SCHEDULE OF
RATES (E&M)-2025 with connectors, suspended from the ceiling with two
numbers GI Suspenders i/c base of suitable size GI angle, GI bolts & nuts, fastner
etc as required.
Digitally signed by DIWAKAR
No. NSI Description Unit QTY NSI RATE SI Rate NSI AMOUNT
4.6.1 100 mm wide x 50 mm depth x 1.6 mm thickness. RMT. 0 - 754 - -
4.6.2 150 mm wide x 50 mm depth x 1.6 mm thickness. RMT. 200 - 803 - 1,60,600
4.6.4 300 mm wide x 50 mm depth x 1.6 mm thickness. RMT. 0 - 1062 - -
4.6.6 450 mm wide x 50 mm depth x 2.0 mm thickness. RMT. 0 - 1439 - -
4.6.7 600 mm wide x 50 mm depth x 2.0 mm thickness. RMT. 0 - 1925 - -
40) DSR-2025 Single Phase MCB for FCU / Fan / VRV IDU
Supply, installation, testing and commissioning of Single Phase MCB of following
capacities. It shall conform to DBR & NIIT specification.
Power supply to the main building HVAC panel shall be scope in the electircal
All single phase Indoor unit power supply will be connected through socket
provided by the electrical power provision
The AC contractor shall provide fire shunt relay contact in his panel wherever
necessary along with auto / manual mode selector switch in the outgoing
feeder to take fire input signal (Potential Free Contact). Cost shall be included
in the panel price quoted by him.
Grand Total of Sub Head ''D'' AC Electrical 3,58,857 1,77,400
Grand Total of Sub Head ''D'' AC Electrical 3,58,857 1,77,400
Digitally signed by DIWAKAR
Sub:- Signages Quotation
PROPOSED CONSTRUCTION OF DE-NONILI SCHOOL BUILDING FOR CTPS TOWNSHIP AT CHANDRAPURA,
S.No. Description Unit Qty RATE Amount
# EXTERNAL SIGNAGES
1 MAIN GATE SIGNAGES
Providing and fixing External Signage's made of SS 304 (brush finish) 1mm thk.sheet for Logo and letters with raising(letter
depth of 50mm). Including all fittings, accessories, fixtures, fabrication.The signage will be front illuminated/hollow
illuminated either back or front of the signage to be made of 3.5 mm thick acrylic. 3M/Avery/LG Cast vinyl 90 micron and 5
7 sq meter Nos. 0 327647 0
years warrenty for desired colour with OSRAM make or equivalent/as per approved make list LEDS and IP 67 Grade
OSRAM powersupply with 5 years warrenty fixed on the wall with necessary fixtures. Height of a letter is not less than 400
mm. (IN HINDI + ENGLISH + LOGO)
2 Entry/ Exit Signage - Wall / Surface Mounted IN/OUT/NO ENTRY/ NO EXIT)
Providing and fixing IN/OUT lit Mounted Exterior Signage sides is to be made of 80 mm width, extruded alloy 6063 of
having no screws visible outside. duly anodized 18-20 microns champagne/ brown/ silver finish with in built in provision to
received the sign face panel in 4.5mm Acrylic on front and having provoison of hold the LED Modules . Sign face is to be
made of graphic plotter cut vinyl 90 micron and 5 year warrenty as per graphic pasted over 4.5mm thick white transluent 600 450 Nos. 2 10868 21736
acrylic. The panel should be made easily openable for maintinace point of view.
Illumination:- The lighting for panel shall be achieved through OSRAM make or equivalent/as per approved make listLEDs
and IP 67 Grade OSRAM powersupply.
3 CAMPUS DIRECTIONAL TOTEM SIGNAGE
Providing and fixing Signage side to be made of 80 mm width modular extrude alloy 6063 of brand 247 sign/cosign/vista
system having no screw visible outside powder coated to 40-50 microns with in built in provision to receive the sign face
panel in acrylic/ACP on both side. Sign face B is to made of 10 thick Acrylic with 2 mm thick laser cut acrylic letters on it.
Internal Frame is to be made of 50x50x3mm MS Section with base plate of thickness 10mm. The panel should be made easily 800 2400 Nos. 0 60920 0
openable for maintaince point of view. 18mm thick grounting bolt for holding base palte of totem.
FOUNDATION WILL BE PROVIDED BY CLIENT.
4 Traffic regulatory Signage ( Drop off/ Speed Limit / No Horn/ BASEMENT Entry/Exit)
Digitally signed by DIWAKAR
Providing and fixing Traffic Regulaotry Non lit Totem Signage, made from Following
A)POST :- Signage is to be made oF 100x100 mm 1800 mm High MS pole, Base Plate of size 250x250mm of thickness
10mm is to be used. Duly powder coated 50 microns in the desired colour.
B) Panel-1 :-Panel size 400X110X1200mm is to be made of 50x50x2mm internal MS frame duly powder coated to 40-50
microns with ACP 4 mm thick, 0.5 mm aluminium foil, 3M / AVERY Prismatic Retro reflective sheet and approved color 600 1900 Nos. 0 41473 0
Overlay film on top having desired text and pictographs on both side post.
C) Panel-2 :- Panel size 600X600 Sq/round with ACP 4 mm thick, 0.5 mm aluminium foil, 3M / AVERY Prismatic Retro
reflective sheet and approved color Overlay film on top having desired text and pictographs.
FOUNDATION WILL BE PROVIDED BY CLIENT.
INTERNAL SIGNAGES
5 BLOCK NAME SIGNAGES (NON - ILLUMINATED)
Providing and fixing External Signage's made of SS 304 (brush finish) 1mm thk.sheet for Logo and letters with raising(letter
depth of 50mm). Including all fittings, accessories, fixtures, fabrication.The signage will be front illuminated/hollow
illuminated either back or front of the signage to be made of 3.5 mm thick acrylic. 3M/Avery/LG Cast vinyl 90 micron and 5
years warrenty for desired colour with OSRAM make or equivalent/as per approved make list LEDS and IP 67 Grade
OSRAM powersupply with 5 years warrenty fixed on the wall with necessary fixtures. Height of a letter is not less than 400
a LAB, MULTIPURPOSE HALL, CLASSROOM 8.5 sq meter Nos. 4 397858 1591432
6 GENERAL INSTRUCTION SIGNAGES
Signage to be made of stainless steel sheet of 1 mm thick 304 grade brush finish including engraving/ etching of letters of
required size filled with colour as desired by engineer,fixing with ss screws on walls. signages to be bilingual/trilingual
b No Littering 300 400 Nos. 4 3064 12256
d Instructional Signages 600 900 Nos. 1 13783 13783
Digitally signed by DIWAKAR
7 AREA IDENTIFICATION SIGNAGES
Supply & installation Signage Made Of Base 3 MM Beton silveri Beton whitel Swiss snow finish ACP panel Box having
6063 Alloy profiles to house the edge of ACP with in groove. Profile size 18X38 mm @edges and to be eprotuded by
5mmx3mm beyond side surface from front side to make teh surface appeared recessed. Powder coated I Anodised as per
approved shade, Fascia 3mm acrylic sheet to be Stuck on base ACP Sheet in staggered manner before fixing of signage then
Content CNC Cut Acrylic 2 mm thick fixed on signage facia. signage to be mounted using clamps at backside of profile. teh
sheets and content to be duly CNC cut with neat and clean polised edges. Profiles make to be 247SIGN/ Tata Elexi / Glo-
lite.or equivalent/as per approved make list
a Room Identification/ Room Name 300 250 Nos. 3 2986 8958
b Room No./Flat No. 150 100 Nos. 3 1005 3015
c Department Name Identification 300 500 Nos. 3 5108 15324
d Washroom Mounted 250 200 Nos. 3 2238 6714
g Floor Level Lift 300 500 Nos. 3 5108 15324
8 AREA IDENTICATION WAYFINDER SIGNAGES
Supply & installation Signage Made Of Frame work of 25 mm x 38 mm 6063 Alloy profiles (PVDF Coated) having (Roman
Ogee) Edge and panel made of 4 MM exterior grade PVDF coated ACP. Frame to house the edge of ACP with in groove.
Content CNC Cut Acrylic 2 mm thick fixed on signage facia. signage to be mounted using clamps at backside of profile, No
screws to be visible. Profiles make to be 247SIGN/ Tata Elexi / Glo-lite.or equivalent/as per approved make list
a Washroom wall projected (Double sided) 300 210 Nos. 4 4317 17268
b Wayfinding signages (Double sided) 1200 250 Nos. 1 16747 16747
c Reception Sign (Single sided) 900 175 Nos. 4 6043 24172
d Waiting area (Single sided) 900 175 Nos. 2 6043 12086
9 Wayfinder sign for basement
Double sided signage will be fabricated using 13+13 mm twin thick ultra slim edge modular aluminium extruded profile with
approved ACP as base duly fixed over on both side and type IV reflective vinyl duly digitally cut and pasted on ACP panels 1050 200 Nos. 4 8738 34952
on both side. Signage will be hanged using SS csble/ SS chain with fastners.
10 Entry Area Identification Signs for Ramp
Single side signage will be fabricated using 13-14 mm thick ultra slim edge modular aluminium extruded profile with
approved ACP as base duly fixed and type IV Avery/3M reflective vinyl duly digitally cut and pasted on ACP panels.
11 FIRE EVACUATION PHOTOLUMINICENT SIGNAGES
Emergency Evacuation Signage :‐ Round Corner signages with radius 8 to 12 mm, made of 2 mm Rigid PVC sheet with
premium photoluminescent of illumination upto minimum 4 hours. With UV printing for Graphic and text. Adhering to latest
NBC Standards. Mounted using SS screws OR 3M VHB tape, as per directions of Engineer-in-charge.
Digitally signed by DIWAKAR
b Stair direction at landing 300 125 Nos. 4 694 2776
c stair floor level Indicator 382 382 Nos. 4 2706 10824
d Fire safety disclaimer 300 300 Nos. 4 1675 6700
e Fire hose cabinet 150 200 Nos. 4 558 2232
f Fire alarm 150 200 Nos. 4 558 2232
g Fire extinguisher 150 200 Nos. 4 558 2232
12 Evacuation Route Identification
Sandwich Acrylic frame work of 5 mm + 5mm thickness. Signages made of premium photo luminescent of illumination upto
minimum 4 hours. With UV printing for Graphic and text. Adhering to latest NBC Standards. Mounted using SS Spacers 18 15 450 Nos. 2 7515 15030
mm x 25 mm, as per directions of engineer incharge. Signages to be bilingual /trilingual language.
13 Poster Frame
Poster frame made of alloy 6063 having copper/bronze anodizing, clip on arrangement for easy change of insert. Use 2mm
clear acrylic as a protection layer in the front. 600 900 Nos. 3 9148 27444
BRAND / MAKE- 247SIGN/ COSIGN/ VISTA System.or equivalent/as per approved make list
G.Total 2276267
Digitally signed by DIWAKAR
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
NITSchool Jharkhand_ CPG.pdf
Tender Document
3 BOQ School.pdf
Tender Document
5 Drawings.pdf
Tender Document
9 Technical specification.pdf
Tender Document
11 SOIL INVESTIGATION .pdf
Tender Document
6 GCC Construction Works 2026 Contractor.pdf
Tender Document
Technical Circulars upd upto 33.pdf
Tender Document
Integrity Pact.pdf
Tender Document
SCC.pdf
Tender Document
Approved Makes.pdf
Tender Document
corrigendum-5672-CORRIGENDUM_03_Price_Bid.pdf
pdf • 0.10 MB
corrigendum-5340-Corr-Adm-02.pdf
pdf • 1.70 MB
corrigendum-5316-Corr01.pdf
pdf • 0.40 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .