Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 LAccepted-AOC CHALITIA BERHAMPORE MURSHIDABAD | BERHAMPORE | MURSHIDABAD | WEST BENGAL | L1 | Accepted-AOC Quoting Lowest rate | |
| 2 | L2₹1.9 L+₹959.64 (0.50%)Rejected-Finance 159B M G ROAD HARIDEVPUR KOLKATA WEST BENGAL 700082 UDYAM WB 10 0018308 | KOLKATA | WEST BENGAL | 700082 | L2 | Rejected-Finance Quoting Higher rate | |
| 3 | L3₹1.9 L+₹2,889.64 (1.52%)Rejected-Finance | L3 | Rejected-Finance Quoting Higher rate |
Tender Value
Refer Docs
EMD Value
₹4,000
Closing Date
28 Feb 2024, 3:00 pmClosed
Office of the Superintending Engineer, Western Ele
Office of the Superintending Engineer, Western Electrical Circle , PWD, Purta Bhavan, 1st floor, Burdwan-713103
Electrical Installation work for proposed Level II Trauma Center at Anamoy SSWH Second Campus of BMCH in the Dist. of Purba Bardhaman (Electrical Work) 6. SITC of Fire Alarm System.
2024_WBPWD_671310_1
WBPWD/SEWEC /BED /NIQ-151/2023-24-2nd Call
Open Tender
ELECTRICAL WORKS ORG
Item Rate
90 days
Bardhaman
Please refer Tender documents.
5 documents required · 5 mandatory
₹4,000
Office of the Superintending Engineer, Western Ele
13 Dec 2024
21 Feb 2024
1 Mar 2024
21 Feb 2024
28 Feb 2024
23 Feb 2024
21 Feb 2024 - 22 Feb 2024
22 Feb 2024
Amount
Cleaning, servicing and checking of all existing Intelligent multisensor Fire Detectors inbuilt with optical smoke sensor as well as additional heat detector sensor as per direction of EIC.
Supply, Installation,Testing & Commisioning of Micropresssor controlled Addressable Multisensor detector IP 42 ( VDS / UL /ERTL/ LPCB / FM approved ) with inbuilt optical smoke sensors and heat detector sensor with inbuilt short circuit fault isolator as per NFPA style 7 wiring complete with base (Note : Detectors without built-in fault isolator is also acceptable provided one independent short circuit fault isolator per detector is to be provided extra without extra cost) the detectors should have built in response indicator with LED indicator. The detector should have 360 degree optical view with single / multiple LED that blinks on actuation of detector. Reverse polarity or faulty zone wiring shall not damage the detectors. (Approved Make : Cerberus Pro / Honeywell/Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton / GST )
Supply, Installation,Testing & Commisioning of Addressable Manual Call Point ( VDS / UL /ERTL/ LPCB / FM approved ) with in built short circuit fault isolator as per NFPA style 7 wiring complete as required. (Approved Make : Cerberus Pro / Honeywell/Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton / GST )
Supply & Laying of 2 Core 1.5 sq.mm FRLS shielded copper Cable (For Loop) (Make. Finolex/Gloster/ RR Kable/Polycab ) through 19 mm dia PVC 'FR' type Rigid Conduit pipe with necessary arrangement as per G.S. (Make : Precision/ AKG/ Universal/ Polycab) on the surface of the wall.
Supply, Installation, Testing & Commissioning of IP Addressable Loop Powered Hooter ( sound output of minimum 90 db ) cum strobe (strength of light 10 cd) complete with inbuilt short circuit fault isolator. Degree of protection IP65 ( VDS / UL /ERTL/ LPCB / FM approved) approved. (Approved Make: Cerberus Pro/Honeywell/ Johnson Controls / Edward /Secutron/ Securiton/ Apollo / Morley / Eaton/ GST )
Testing, rectification and rechecking of Loop line connected with the existing 1 no. Microprocessor based Intelligent Addressable Fire Alarm Control Panel ( VDS / UL / LPCB & FM approved ), and total system healthy with all detector and hooter (Approx-500)incl. Detectors and other Devices for addressing the entire fire detection system as per direction of EIC. of Anamoy SSW Hospital. The rate is incl. of 12V, 9AH, SMF Maintenance Battery (Mk. Exide / Amra Raze) incl. all accessories.
Making necessary drawing of total new & existing repairing installation and submitted to the office as per direction of EIC.
Supply, Installation, Testing & Commissioning of Intelligent signal processing unit having Voltage free NO contact which would be connected in series with magnetic coil of AHU power supply unit. In case of Fire, the voltage free contact would close the circuit to isolate the power supply of AHU. (Approved Make: Siemens Cerberus Pro/ Securiton / Bosch)
Labour charges for dismaintaling the existing fire detection system same such as PVC pipe,wire,dector,device and other accessories etc.[ 4 nos. labour for 3 days]
MONDAL ENTERPRISE
DAS TRADING CO
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .