Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.3 CrAccepted-AOC | ₹2.3 Cr Quoted ₹1.5 Cr | L1 | Accepted-AOC Accepted by TBEC |
| 2 | L2₹1.5 CrRejected-Finance | ₹1.5 Cr | L2 | Rejected-Finance L2 |
| 3 | Rejected-Technical | - | - | Rejected-Technical Disqualified for non submission of Original Affidavit for Correctness |
| Sl No | Description | Qty | Unit | Osman Ali L2 | Rofiqul Islam L1 |
|---|---|---|---|---|---|
| 1.01 | Construction of road from MRL 04- Laharighat to Moritoli including CD works and routine maintenance for 5 years under PMGSY II Package No. AS-17-231 for the year 2019-20 for Balance work | 1 | Nos | 1,52,50,700 ₹1.5 Cr | 1,52,47,000 ₹1.5 Cr |
Tender Value
₹2.3 Cr
EMD Value
₹4.6 L
Closing Date
13 Jan 2026, 2:00 pmClosed
SE Morigaon Road Circle, Morigaon
O/o the SE Morigaon Road Circle, Morigaon
Construction of Road from MRL 04 Lahorighat to Moritoli including CD Works and Routine Maintance for 5years under PMGSY II for the year2019- 20 (Balance Work
2026_CEASM_146087_1
SE/MRC/TB/NIT/O1/2023-24/75
Open Tender
Civil - Roads and Bridges
70 days
SE Morigaon
Please refer Tender documents.
6 documents required · 6 mandatory
₹4,555
₹4.6 L
Yes
26 Mar 2026
8 Jan 2026
13 Jan 2026
8 Jan 2026
13 Jan 2026
8 Jan 2026
8 Jan 2026 - 13 Jan 2026
Construction of road from MRL 04- Laharighat to Moritoli including CD works and routine maintenance for 5 years under PMGSY II Package No. AS-17-231 for the year 2019-20 for Balance work
Item Rate BoQ
BoQ_Ver3.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
Construction of Embankment with Material Obtained from Borrow Pits Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 i) Private land
Construction of Subgrade and Earthen Shoulders Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1. (I) Private Land For Shoulder
Granular Sub-base with Well Graded Material (Table 400.1) By Mix in Place Method:-Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. For Grading Material (Gr - II ) For New Construction Portion
WBM Grading 3 Using stone screening Type-B 11.2 mm for Gr.III Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405......By Manual Means
Providing and laying interlocking concrete block pavement with M40 grade grade of concrete blocks having thickness 80mm as per technical specification clause 1504 complete including carriage.2....(a). Including Edge block/ Edge restraints
Construction of plastic cell filled cement concrete pavement, thickness 100mm (as per design), over a prepared sub base, with 53 grade Ordinary Portland Cement(OPC) or any other type as per Clause 1501.2.4 M30 (Grade), coarse and fine aggregates conforming to IS : 2386, mixing in a concrete mixer of not less than 0.2 cum capacity and appropiate weigh batcher using approved mix design (As per IRC:44-2008), laid in the cells made of high density polythyne sheets of thickness 0.22mm to about 0.25mm,side 150mm and depth 100mm of approximate weight of 1250 kg for a road of 3.75m wide and 1.00km , putting iron spike of 200mm long at the end corners of the cells and using nylon threads passing through the cells 10 mm below the top of the cells, in approved fixed side formwork (steel channe, wedges, steel plates including levelling the formwork as per drawing),maitaining camber of about 3 to3.5%, spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation, curing of concrete slabs for 14- days, curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification of Cell filled Concrete Pavement Published by NRRDA
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 A. With crushed stone. (I) P.C.C grade M 10 Nominal mix 1:3:6
Brick masonry work in cement mortar in foundation complete excluding pointing and plastering as per drawing and technical specifications Clauses 600, 1202 & 1203 (I) Brick masonry in 1:3 cement mortar
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 B. With Natural Gravel (ii) R.C.C M25 (a) Height upto 5M
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
Supplying, fitting and placing TMT bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
Plain/ Reinforced cement concrete in substructure complete as per drawing and technical specification Clauses 802, 804, 805, 806, 807, 1202 & 1204 -B) withCrushed stone V) RCC Grade M-20 Nominal Mix (1:2:4). (Exclusive of reinforcement)
Construction of RCC railing of M-25 Grade cast in situ with 20mm nominal size aggregate true to line and grade toleance of vertical railing post not to exceed 1 in 500 center to center spacing between vertical post not to exceed 2000mm as per drawing and technical specification caluse 800, 900 and 1208.3 withCrushed stone.
Providing and laying cement concrete wearing course M-30 grade including reinforcement complete as per drawing and technical specification clause 800 and 1206.3 with crushed stone
Supplying fitting and placing TMT bar reinforcement (Fe 415) in substrcture complete as per drawing and technical specification clause 1002, 1005, 1010 & 1202.
Providing and laying boulder apron for bed protection with stone boulders of minimum size and weight as per Table 1300.1, no fragment weighing less than 25 kg laid dry complete as per drawing and technical specifications Clause 1301
Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1302. (i)Stone/Boulder
Providing and laying filter material underneath pitching in slopes complete as per drawing and technical specifications Clause 1302
Trafic - Signs B. Semi Reflective Traffic Signs Providing and fixing of semi reflective cautionary, mandatory and informatory sign board as per IRC:67 made of 1.5 mm thick MS Sheet duly stove white colour in front and gray colour on back with red reflective border of 65 mm width and required letters and figures with reflective tape engineering grade as per Clause 1701.3.9 of MORD for Rural Roads of required shade and colour supported and welded on 47mm x 47 mm x 12 SWG sheet tube firmly fixed to the ground by mean of properly designed foundations with M-15 grade cement concrete 450x450x600 mm, 600 mm below ground level as per approved drawing Clause 1701.2.2 90 cm octagon
Trafic - Signs B. Semi Reflective Traffic Signs Providing and fixing of semi reflective cautionary, mandatory and informatory sign board as per IRC:67 made of 1.5 mm thick MS Sheet duly stove white colour in front and gray colour on back with red reflective border of 65 mm width and required letters and figures with reflective tape engineering grade as per Clause 1701.3.9 of MORD for Rural Roads of required shade and colour supported and welded on 47mm x 47 mm x 12 SWG sheet tube firmly fixed to the ground by mean of properly designed foundations with M-15 grade cement concrete 450x450x600 mm, 600 mm below ground level as per approved drawing Clause 1701.2.2 60 cm equilateral triangle
Kilometre Stone Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703 i) 5th Kilometer Stone
Kilometre Stone Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703 ii)Ordinary Kilometer Stone (precast)
Kilometre Stone Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703 iii)200 m Stone (precast)
Construction of RCC guard posts of 250 mm dia M15 grade cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical RCC posts not to exceed 1 in 500 as per drawing and Technical Specification Clause 1608.2 Rate as per the Annexure - II
Providing and Fixing 'Logo' of PMGSY Project Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1
Providing and fixing of typical Citizens Information Board and Maintanance Information Board with Logo as per MORD specifications and drawing. Two nos. 1.6mm thick MS sheet duly welded with 5mm thick steel plate on back on edges. The 4 nos. steel plate will be welded horizontally with 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x 750mm, 750mm below ground level. The 2 nos. steel plate will be welded vertically to 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly welded to vertical tubes. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and coloue. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1
Title Informatory Board with Logo as per MORD specifications and drawing. Two nos. 1.6mm thick MS sheet duly welded with 5mm thick steel plate on back on edges. The 4 nos. steel plate will be welded horizontally with 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x 750mm, 750mm below ground level. The 2 nos. steel plate will be welded vertically to 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly welded to vertical tubes. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and coloue. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1
Plain / Reinforced Cement concrete in substructure complete as per drawing and Technical Specificationas clause 802, 804,805,807,1202 and 1204 . IV) RCC Grade M 25 i) Height upto 5.0m
Supplying, fitting and placing conforming to IS:1786 TMT reinforcement bar Fe-500 from primary producer like TATA/SAIL/SHYAM STEEL/ESSER STEEL/JINDAL STEEL/RINL etc. in Sub-Structure complete as per drawing and technical specifications a) TMT - IS 1786 (Fe-500 D) from Primary Producer like TATA/SAIL/SHYAM STEEL/ESSER STEEL/JINDAL STEEL/RINL etc.
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 i). Granular material
Providing and laying cement concrete wearing coat M 30 gradeincluding reinforcement complete as per drawing and technical specifications clauses 800,1206.3
Painting Two Coats on New Concrete Surfaces..Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered / concrete surfaces as per drawing and Technical Specification Clause 1701
RCC GUIDE POST Construction of RCC guard posts of 250 mm dia M15 grade cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical RCC posts not to exceed 1 in 500 as per drawing and Technical Specification Clause 1608.2
Providing and laying Pitching on slopes laid over prepared filter media for embankment protection complete as per drawing and Technical specifications
Providing and laying Filter material underneath pitching in slopes for embankment protection complete as per drawing and Technical specification
Boulder apron laid in (Providing and laying of boulder apron laid in wire crates with 4mm dia giyr conforming to IS 280 and IS 4826 in 100x100 mesh(oven diagonally including 10% extra for laps and joints laid with stone boulders weighting not less than 25Kg each.)
Earthwork in excavation for foundation of structures upto 3 m depth as per drawing and technical specification Clause 1104 includding setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
Plain Cement Concrete M10 (1:3:6 nominal mix) in levelling course below open foundation of Head walls as per drawings & Technical Specification Clause 1109
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 IV. RCC Grade M 25 i)For height upto 5 m
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 I) R.C.C grade M 25 a)Height upto 5 M
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX or equivalent)) in sub-structure complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar . (Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX or equivalent)) in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202
Plastering with Cement Mortar (1:4), 15 mm thick on brickwork in substructure as per technical specification
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification B)Sandy material
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 3.37 MB
Tendernotice_2.pdf
PDF • 5.34 MB
Tendernotice_3.pdf
PDF • 0.54 MB
Tendernotice_4.pdf
PDF • 0.34 MB
Tendernotice_5.pdf
PDF • 0.34 MB
BOQ_226519.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid