Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 01₹40.3 LAccepted-AOC | 01 | Accepted-AOC FOUND LOWEST AND REASONABLE HENCE TENDER ACCEPTED | |
| 2 | 02₹41.4 L+₹10,945.91 (0.27%)Rejected-AOC | 02 | Rejected-AOC NOT LOWEST | |
| 3 | 03₹44.4 L+₹3.1 L (7.59%)Rejected-AOC | 03 | Rejected-AOC NOT LOWEST | |
| 4 | 04₹44.4 L+₹3.2 L (7.71%)Rejected-AOC | 04 | Rejected-AOC NOT LOWEST | |
| 5 | 05₹46.1 L+₹4.8 L (11.6%)Rejected-AOC | 05 | Rejected-AOC NOT LOWEST |
Tender Value
₹46.0 L
EMD Value
₹91,900
Closing Date
27 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SHRI MAHAVIR SINGH, IDSE, GE (SOUTH)
GARRISON ENGINEER (SOUTH), MUDFORT, SECUNDERABAD PIN - 500003
SPL REPAIRS TO MD ACCN BLDG NO P-98/01 TO P-98/08 AT OLD LINE SAFILGUDA OF 654 EME BN INCL CERTAIN MINOR WORKS UNDER GE SOUTH SECUNDERABAD
2022_MES_569185_2
GE(S)/SEC/TOKEN-30 OF 2022-23
Open Tender
Civil Works
Item Wise
270 days
GE SOUTH, MUDFORT, SECUNDERABAD
For Enlisted contractors class D and above category a (i) and b (i) and for unenlisted contractors meeting the eligibility criteria of above class and category for along eligible class with EMD
5 documents required · 5 mandatory
₹500
GE SOUTH, MUDFORT, SECUNDERABAD
₹91,900
Yes
25 Mar 2023
31 Jan 2023
1 Mar 2023
31 Jan 2023
27 Feb 2023
8 Feb 2023
31 Jan 2023 - 7 Feb 2023
Amount
M&L for surface dressing n. exc 15cm deep in soft loose soil including refilling of earth all as specified and as directed.
M&L for surface excavation not excavation 30 cm deep and averageing 15cm deep and getting out soft loose soil for burried of ground earth strip all as specified and as directed.
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5m in depth for foundation on manholes etc, and area n.exc 10 Sqm on plan and getting out in hard/dense soil all as specified and as directed..
Excavation in trenches n.exc. 1.5 m wide and exc. 1.5 m and n. exc. 3.0 m in depth for foundation or manholes etc., and area n.exc. 10 Sq.m on plan and getting out in hard/dense soil all as specified and as directed.
Returning filling in incuding spreading levelling and well ramming in soft/loose soil complete all as specified and as directed.
Removing excavated materials in exc 50 Mtrs an deposited where at a level n. exc 50 mtr where directed n exc 1.50m above the starting point complete all as specified and as directed.
M&L for broken brick bats of 63 mm size deposited spread and levelled in layers n.exc 15 cm complete all as specified and as directed.
M&L PCC 1:4:8 Type D2 using 40mm graded aggregates as in foundations, filling and mass concrete complete all as specified and as directed.
M & L for PCC 1:3;6, type C1 (using 20 mm graded stone aggregate) as in bed blocks for hold fasts etc including necessary form work complete all as specified and as directed.
M & L for PCC 1:2:4 type B0, (12.5mm graded aggregate) as in levelling course including weathering slightly rounded or chamfered angles and throating as directed complete all as specified and as directed.
M&L for PCC type B1 1:2:4 (20mm graded aggregate) as in copings for manholes, plinth courses, bed plates, kerbs incl necessary formwork etc all as specified and directed..
M/L Precast cement concrete block masonry with solid blocks, exc. 10cm in width and setting in mortar,CM 1:4 complete all as specified and as directed.
M&L Precast reinforced cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate ) for manhole cover septic tank covers slabs etc including necessary form work and set in CM (1:4) all as specified and directed. Note:- Reinforcement and form work will be measured and paid seperately.
M/L Reinfored cement concerete M-25 design mix as in in slab supported on wall complete all as specified and as directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan exceeding 6m mean radins built in cement mortar 1:6 complete all as specified and as directed.
M/L brick work with Fly Ash bricks built in CM 1:4 straight or curved exceeding 6m mean radius complete all as specified and as directed.
Cutting chases, for concealed water tubing or concealed conduit wiring, etc.pinning in, making good to facings where required and pointing in cement mortar 1:3 not exc 10cm girth complete all as specified & directed.
M&L Form work to soffits of suspended slab such as roof slab, floor slab, floor etc. n. exc 200mm thick rough fineshed surface of concrete slab complete all as specified and as directed.
M & L plain fillets square, rectangular in section clean sawn secured with nails or brads 2nd class soft wood sectional area n.xc 3 sq cm each complete all as specified and as directed.
M & L second class hard wood Plain, solid, straight, chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed complete all as specified and as directed.
S&F 35mm 2nd class hard wood plain framed factory made panelled shutters (two panel) with lock rail and panel of 9mm BWP commercial plywood or 12mm thick veneered particle board with commercial veneering on both faces, size of rail and tile as per IS 1003 (Part-I0 Kiln seasoned and chemically pressure treated complete all as specified and as directed.
S & F 25mm thick flush shutter solid core construction with block board core and ply wood face panels commercial type on both sides complete all as specified and as directed.
Taking down frames (including grills/wire mesh) with shutters n.exc 1.50 Sqm each (without taking off shutters from the frame) complete all as specified and as directed.
Taking down frames (including grills/wire mesh) with shutters n.exc 1.50 Sqm but n.exc 4.00 Sqm each (without taking off shutters from the frame) complete all as specified and as directed.
Taking down Chowkats with shutters / MS Grills (Without taking off shutters from frame) area exc 1.5 Sqm but not exc 4.00 Sqm complete all as specified and as directed.
Taking down shutters of any description exc 1 Sqm and n.exc 2 Sqm each complete all as specified and as directed.
S & F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC `C' channel heaving a PVC sheet strip of 20mm width suck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S frame wedded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing complete all as specified and as directed.
S & F Solid PVC Door Frame of size 50mm X 47mm made out of 5mm plain colour PVC sheet reinforced with M S Square tube,supplying and fixing in opening as per manufacturers instructions and complete all as specified and as directed.
S&F solid PVC wall lining consisting of 5 mm thick wood grain printed PVC sheet inclusive of solvent cement and fixing at site on PVC frame including beading complete all as specified and as directed.
S&F 5 mm thick PVC sheet fillet of width 35 mm for wall panelling inclusive of fixing on to wall to make PVC frame as per specfication and drawing complete all as specified and as directed.
S&F 200mm long aluminium barrel tower bolt barrel tower bolts of extruded section and fixed complete all as specified and as directed.
S & F in 300mm size aluminium alloy anodised sliding door bolt with hasp and staple (bolt type) and fixing clips of seat cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed.
S&F 250mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and as directed.
S & F 100mm butt hinges medium weight cold rolled mild steel complete all as specified and as directed.
S&F 150mm long aluminium handles cast type anodised complete all as specified and as directed.
S & F 100mm aluminium hasp and staple complete all as specified and as directed.
S & F fancty type power coated 20mm dia curtain rod with fancy type bracket fixed on wall complete all as specified and as directed.
S & F tubular towel rail brass chromium plated 20mm dia D type 60 cm, between the flangers complete all as specified and as directed.
S&F stainless steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm complete all as specified and as directed.
S&F in repairs stainless steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm complete all as specified and as directed.
S & F Framed work such as Grills, gratings, gates etc with ends of bars shouldered and/ or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, frame work of water tanks and similar works Confirming to Fe-290( Gde E - 165) complete all as specified and as directed.
S & F MS hold fases (FI 25X3, 250mm long) conforming to Fe-290, Gde E-165, complete all as specified and as directed.
S/F MS TMT bars 10 mm dia and over for reinforcement etc, cut to length, bent to shape required including cranking, bending sprially for hopping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed.
S & F MS TMT steel bars 5mm dia and over up to and including 10mm dia as in stirrups, spacers cut to length bent shape reqd incl cranking, bending and binding with MS wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
S & F steel window with side hung shutters incluidng projecting type hinges with steel handle and peg stays with glazing bars, devotailed or welded complete all as specified and as directed.
Ditto all as per item no 45 but without glazing bars complete all as specified and as directed.
S & F steel ventilator with top hung shutter including hinges, steel peg stay complete complete all as specified and as directed..
S&F Anodised aluminium frame for door, windows, ventilators with one or more rebates incl joining cleats and other accessories for fixing complete all as specified and as directed.
S & F 18/19mm thick prelaminated particle board exterior grade, prelaminated one side with decorative choke laminated and other side balancing white lamination fixed with screwed and beading complete all as specified and as directed.
M & L for 75mm thick PCC 1:3:6 type C1, (20mm graded aggregate) as in plinth protection laid in panels including finished the surfaces smooth and even without using extra cement complete all as specified and as directed.
M&L for 25 mm thick PCC 1:2:4 type B0 (using 12.5 mm graded stone aggregate) finished fair & even as in Sub base flooring complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement morytar bedding (but not backing), removing rubbish off the premises complete all as specified and as directed.
Takiang down cement plaster/terrazzo finish on brick/RCC/stone wallsof any description including racking out joints hacking for keys scrubbing down with water etc, complete all as specified and as directed.
S&F 4mm thick plane glass pin head type and glazing with oil putty in square panes. Not exc 0.50 sqm in each pane complete all as specified and as directed.
M&L Preparatioin of new wooden surfaces of any description over 10CM width or girth and applying two coats of synthetic enamel paint over a coat pink primer complete all as specified and as directed.
M&L Preparatioin of old wooden surfaces of any description over 10CM width or girth and applying one coats of synthetic enamel paint over a coat pink primer complete all as specified and as directed.
M&L Preparatioin of new steel surfaces of any description over 10CM width or girth and applying two coats of synthetic enamel paint over a coat pink primer complete all as specified and as directed.
S&F in repair rotational moulded polyethylene water storage tanks 1000 ltrs(cylindlerical vertical with closed top) hoisted and fixed in position all as specified in SSR part Icomplete all as specified and as directed.
S & F in repairs 15mm bore stop valves fancy type chromium plated screwed both ends for iron pipe for unions and fixed with long shank and cup (concealed type) complete all as specified and as directed.
S&F Concealed stop cock but fancy type 15mm dia, chromium plated with long shank and cup(Concealed)type all as specified and as directed.
S&F in repairs Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed 20mm bore all as specified and directed.
S&F Ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed (minimum weigth 455gms) 20mm bore complete all as specified & directed.
S&F grating doom 150 mm dia of PTMT in repairs complete all as specified and as directed.
PVC connections 15mm size with PTMT nuts of length 600mm complete all as specified
S&F 600 mm long PVC connections, 15 mm dia with PTMT nuts, complete all as specified and as directed.
S & F 110mm bore PVC (SWR) pipes double socketed in any length with rubber ring joints fixed to walls, complete all as specified and as directed.
S & F 75mm bore PVC (SWR) pipes double socketed in any length with rubber ring joints fixed to walls, complete all as specified and as directed.
S&F 75mm bore PVC SWR bends any radius complete all as specified and as directed.
S&F PVC(SWR) bends 110 mm dia complete all as specified and as directed.
S & F 75mm bore PVC (SWR) branch piece with access door, single 'Y'/'T' equal or un-equal complete all as specified and as directed.
S & F 110mm bore PVC (SWR) vent cowl complete all as specified and as directed.
S & F 110mm aid PVC (SWR) WC connector with lip ring complete all as specified and as directed.
S & F 75mm dia, PVC (SWR) floor trap, plain with grating and jointing to waste pipe with solvent cement and fixed in PCC 1:2;4, type B1, complete all as specified and as directed.
S & F for PVC (SWR) gully trap of 125/110mm dia set and jointing with solvent cement complete all as specified and directed.
M & L concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested in cement concrete 1:3:6 type C-2 for 100mm dia pipe complete all as specified and as directed.
Description all as per item No. 75 above but 150mm dia drain pipe
M & L for SWG drain pipes grade 'A' of 100mm internal dia laid in trenches and jointed in cement mortar 1:1 complete all as specified and as directed.
M&L for SWG drain pipe grade 'A' of 150 mm internal dia laid in trenches and jointed in cement mortar 1:1complete all as specified and as directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting ou existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required for 100 mm dia SWG pipe all as specified and directed.
Description all as per item 79 above but 150mm dia complete all as specified and as directed.
S & F sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes, including waste coupling and waste pipe and including bedding in cement mortar to dwarf wall or including fixing cantillever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and as directed.
Demolition of brick work or stone boulders masonry built in Cement mortar (or) cement lime mortor including all quions, arches, pillars etc complete all as specified and as directed.
Demolition of un reinforced cement concrete in ground floors and paving n.exc 15 cm thickness (below & above ground level) complete all as specified and as directed.
Demolition and breaking up drain pipes (salt glazed ware, AC or reinforced concrete) set in cement mortar 100mm dia complete all as specified and as directed.
Description all as per item No. 85 above but 150mm dia pipe complete all as specified and as directed.
Supply and Laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings of 40 mm dia in trenches complete all as specified and as directed.. Make : Reliance/Finolex/Supreme/Prakash
S & F, 35mm thick, 2nd class hardwood factory made partly panelled and partly glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edge of framing plain, chamfered or rounded, fitted with cut and mitred beds for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8. clause 8.24 complete all as specified and as directed.
M & L for 20 mm thick Granite (of any type) work (table rubbed and polished) for Urinal Partitions fixed to wall including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including 20 mm thick screed bed in cement mortar 1:6 complete all as specified and as directed.
M &L granite 20mm thick (of any type) work table robed & polished cooking platforms and like over 15mm thick screed bed or bedding in layer of CM 1;4 for laying floor finishes incl pointing in white cement 1:2 using marble dust with admixture of pigment to match the shade of granite, and half moulded at one side including demolition of old stone any type complete all as directed and as specified by Egnr-in-Charge.
Roughening surfaces of old concrete floor by picking sweeping cleaning & washingg down with water to remove dust etc applying one coat of neat cement slurry @ 3.00 kg/Sqm complete as directed by Engr-in-charge.
Roughening surfaces of old concrete roof by picking sweeping cleaning & washingg down with water to remove dust etc applying one coat of neat cement slurry @ 3.00 kg/Sqm complete as directed by Engr-in-charge.
M&L for glazed ceramic tiles, coloured, of size 350 x 250 x 7mm , as in vertical surfaces such as skirting, dados etc set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10mm thick backing coat in cement mortar 1:4 complete all as specified & directed
M&L for Non skid ceramic coloured tiles 7-8 mm thick (Square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm in floors surface set and jointed in neat cement slurry and pointed with white or colour cement to match over and including 15mm thick screed bed in cement mortar 1:6 complete all as specified & directed.
M & L Non skid ceramic coloured tiles 7 to 8mm thick (Squared/rectangular) area of each tile exc 0.11 Sqm but n.exc 0.18 Sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bed of 15mm thick in CM 1:6 complete all as specified and as directed.
Material & labour 15mm thick rendering in CM 1:4 on fair faces of bricks wall or concrete surfaces finished even and smooth complete all as specified and as directed.
M & L glazed ceramic coloured tiles in vertical surface 300x200mmx7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete in position laid on over 10mm thick backing coat in CM 1:3 on wall, complete all as directed and as specified by Engr-in-charge.
M & L rendering 15mm thick on concrete or fair faces of brick work in CM 1:6 finished even and smooth without using extra cement complete all as directed and as specified.
M & L rendering 15mm thick on concrete or fair faces of brick work in CM 1:4 finished even and smooth without using extra cement complete all as directed and as specified.
M & L for rendering 10mm thick in CM 1:3 on concrete surface while concrete is green including mixing W.P compound @ 3% by weight including finished the surface smooth and even without using extra cement. Note:- WPC will be measured and paid separately.
Supply only water proofing liquid complete all as specified and as directed.
M & L for rendering 10mm thick in CM 1:4 rendering on cocrete surface such as ceiling chajjas etc finished evena and smooth (without using extra cement) all as specified and as directed.
M/L for applying two coats of white wash on old wall complete all as specified and as directed.
M & L for complete removal existing treatment and applying two coat of distemper oil emulsion on walls over a coat of primer over 3mm thick Birla wall care putty including preparation new wall surfaces complete all as specified and as directed.
M & L for complete removal of existing treatment and applying two coats of cement base paint over a coat of primer including preparation of old plaster surfaces of walls, complete all as specified and directed.
M & L for two coats of cement base paint over a coat of primer including preparation of newly plastered surfaces of wall complete all as specified and directed.
M & L for applying two coat of distemper oil emulsion on walls over a coat of primer over 3mm thick Birla wall care putty including preparation new wall surfaces complete all as specified and directed.
M & L for applying three coats of white wash on wall including preparation of new plastered surfaces complete all as specified and as directed.
M & L for applying one coat of white wash on ceiling including preparation of old plastered surfaces complete all as specified and as directed.
M&L for two coats of white wash over a coat of primer with alkali resistant after preparation of newly plastered surface on wall all as spd and directed.
M&L for applying two coats of OBD over one coats of primer on newly plastered wall incl preparation of newly plastered surface of wall complete all as specified and directed..
S&F of 16 mm bore cpvc pipes SDR 11 pipes & Plain CPVC SDR 11 fittings and fixed complete to walls and ceiling or laid in floors in cluding its taking down complete all as specified & directed. Make : Reliance/Finolex/Supreme/Prakash
S & F 20mm bore tubes medium grade galvanised with all fitting and fixed concealed type complete to walls and ceilings or laid in floors 15mm bore including taking up or down steel tubing and connections, including cleaning for refixing (or) removed to store.
S&F of 16 mm bore CPVC pipes SDR 13.5 pipes & Plain CPVC SDR 11 fittings and fixed complete to walls and ceiling or laid in floors in cluding its taking down complete all as specified & directed. Make : Reliance/Finolex/Supreme/Prakash
S&F of 20 mm bore cpvc pipes SDR 13.5 pipes & Plain CPVC SDR 11 fittings and fixed complete to walls and ceiling or laid in floors in cluding its taking down complete all as specified & directed. Make : Reliance/Finolex/Supreme/Prakash
Demolition of existing tank of any description and S & F 500 ltrs rotational moulded polythylene water storage tanks, cylindrical vertical with closet top hoisted and fixed in position all as specified in SSR Part-I including 20mm dia PVC high pressure float valve complete all as specified and as directed.
S & F in repair bib tap 15mm bore, fancy type, chromium plated, cast copper alloywith crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed.
S & F 75mm bore PVC (SWR) bends any radius with access door complete all as specified and as directed.
S & F 110mm bore PVC (SWR) bends any radius with access door complete all as specified and as directed.
S & F PVC valveless syphonic action type low level flushing cistern 10 Ltr capacity with inlet, ball valve, float and handle incl brackets and flush pipe of polyethylene of low or high density PVC. 32 mm dia all as specified and directed
S & F Soap dish, any type, fixed to plugs with chromium plated brass incl all fitting & fixtures complete all as specified
S&F wash down water closet (pedestal pattern) white with plastic water closet seat cover closed pattern incl P or S trap with flat bottom and mild steel chromium plated or aluminised hinging device and flush pipe of low density PVC 32mm dia for low level flushing cistern complete all as specified and as directed.
S& F in repairs water closet (squatting pan) complete including provision of leam concrete bedding 'Orissa' pattern size 580 x 440mm white, integral foot rests including flushing cistern and flush pipe, PVC connection of size 450mm complete all as specified and as directed by Egnr-in-Charge.
S & F in repair chromium plated swivel shower complete all as specified and as directed.
S & F Toilet paper holder, vitreous China, box type fixed to walls with chromium plated (CP) brass screws complete all as specified and directed
S&F vitreous china wash basin, white with pedestal , flat back size 630 x 450mm including 01 Nos cast copper alloy 15mm CP pillar tap, 01 Nos 32mm waste coupling,waste pipe and pipe, one pair of MS bracket, cutting for and pinning in ends of brackets or erecting stand complete all as specified and as directed.
S & F in repairs vitreous china wash basin, white, flat back, size 550x400mm including cutting for and pinning in ends for brackets, fitting with pillar tap 15mm bore, fancy type cast copper alloy, with capstan heads, chromium plated, screwed down, high pressure, with or with out letter 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe and waste fittings 32mm includkng waste pipe, brass chromium plated with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed complete all as specified and as directed.
S & F health faucet with spray jet (hand shower) cromium plated incl all fitting & fixtures complete all as specified
S & F 2nd class hard wood in fillets, square, rectangular in section wrought, secured with nails sectional area n.exc 13 sq cm and n.exc 25 Sq cm fixed in repairs complete all as specified and as directed.
S & F in repairs 300mm size aluminium alloy anodised sliding door bolt with hasp and staple (bolt type) and fixing clips of seat cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed.
S&F 100mm long SS butt hinges, medium weight cold rolled all as specified and as directed..
M & L for rendering 15mm thick on concrete or fairfaces of brick work in CM 1:4, finished even and smooth without using extra cement but mixing WPC complete,all as directed and as specified (Note:- WPC measured and paid separately).After plastering the sunken surface, sunken portion to be filled with water and tested for 72 hrs (after required period of curing) to observe leakage/seepages, leakages/seapage if any shall be arrested by pressure grouting and re-tested till leakage/seepages completely stopped. After pointing test, the surface shall be dried and bottom and sides of the sunken slabs shall be treated, priming the plastered surface with bituminous primer conforming to IS-3384 @ 0.3 Kg per Sqm and applying a tack coat of industrial bitumen 85/25 @ 1.2 kg per Sqm over which applying using glass fibre base bituminous felt type II and grade 2 (conforming to IS-7193 1994) and applying one coat of hot blown bitumen of grade 85/25 @ 1.5 Kg per Sqm including 450mm long 25mm dia medum grade GI pipe shall be provided at the lowest in case of leakage. The joints in CI/GI/PVc pipes, Nahani traps, WC and P/S trap connection shall be made leak proof. The gap around the pipes in walls/beams shall be properly filled and sealed with water proof joints fillers all as specified and directed by Engineer-in-Charge.
S & F kitchen plate rack(900X600mm) made of stainless steel, complete all as specified and as directed..
S&F two way bib cock/tap 15 mm chromium plated complete fancy type of branded as specified and directed.
S & F of 15mm dia Stop valves/Angle cock, cast copper alloy fancy type, chromium plated screwed both ends for ironpipe or for unions and fixed complete all as specified and as directed.
M&L priming the plastered roof surfaces with bitumenous primer @ 0.30 kg over applying hot bitumen VG-30 ,1.2kg/Sqm and applying APP based polymeric membrane weighing 3 kg per Sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt not less than 150gms/per sqm) and on primed surface by forced torch application over that applying bitumen base alluminium Paint 0.2 Kg/Sqm complete all as spescified all as specified and as directed.
S & F vitreous china bowl urinal full stall type,white with grating and union for discharge pipe including 32 mm (LDPE Pipe)waste pipe, waste pipe 1 m length , complete including providing & fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with screws, pointing around urinal back in cement complete all as specified and as directed
Supply and fixing porcelain insulator with necessary arrangements on the roof/wall for fixing copper strip all as specified and directed.
Taking down existing unserviceable point wiring of any description/type/ size of light/ fan/tube/power/two way/bell point etc on TW batten/conduit including removal of batten / conduit / gutties / wooden boards / switches / sockets / regulators/ light fittings etc and removal of unserviceable material out of site and making good the disturbed surfaces of wall/ceiling so as to match with the existing finishes all as specified.
M & L for Concealed Conduit Point wiring with 1.5 Sq mm copper conductor single core PVC insulated cable FRLS type 1100 V multistranded drawn through conduit and including rigid PVC conduit and conduit accessories of suitable dia medium grade and pressed steel terminal boxes of 1.6 mm thick MS duly painted with red oxide metal primer including fixing/grouting sunken/ surface as per site requirement covered with 3 mm thick laminated hylam sheet including running up of 1.5 Sq mm copper conductor PVC insulated cable as earth continuity conductor along with wiring and connecting to the common earth dolly for fixing the switches/ sockets/ regulators etc all as specified for Note : The rate for cutting chases, plastering, painting with two coats to match the existing colour is demised to be included in the rate quoted. for one light point controlled by one, one way switch 5A, SP
All as per item No. 141 here in before but one ceiling / exhaust fan point controlled by one, one way switch
All as per item No. 141 here in before but one light point controlled by two 2 - way switch 5 amps, SP
All as per item No. 141 here in before but one 2/3 pin 5 Amps switch socket outlet point controlled by one switch on the same board
All as per item No. 141 here in before but one 3 Pin 5 Amps switch socket Independt board
All as per item No. 141 here in before but one bell point controlled by one bell push
All as per item No. 141 here in before but using 4 Sq mm single core copper conductor cable of multistranded PVC insulated FRLS 1100 Volts grade for 5/15 Amps switch socket combination point including running of 4 Sq mm copper conductor PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly complete all as specified and as directed NOTE: For item No. 141 to 147 cover plate with frame and metal flush box will be inclusive of rate quoted..
S & F lamp holder insulated body with back plate for angle/batten fittings fixed with wooden round blocks complete all as specified and as directed.
S & F Switch piano type single pole one way flush type 5 Amps capacity 230 volts complete all as specified and as directed.
S & F Modular Switch 1 way 16 A, 1 Module capacity 230 Volts complete all as specified and as directed.
S&F bell ding dong working on 230 volts AC Supply complete all as specified and as directed.
S & F Modular Socket, 6A- 2/3 combined 2 module of capacity 230 Volts complete all as specified and as directed.
Supply and fix Modular ceiling fan regulator 2 module step type AC 240 volts suitable for 1200/1400 mm sweep. complete all as specified and as directed.
Supply and fix switch socket combination flush type multipurpose 2/3 pin 5 Amps, 230 Volts complete all as specified.
Supply and fix switch socket combination flush type multipurpose 5 in 1, 5/16 Amps, 230 Volts complete all as specified.
S & F single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as specified and directed by Engineer in charge complete all as specified and as directed.
S and F sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 Volts double door with magnetic locking system complete all as specified.
S & F sheet metal enclosure MCB DB SPN 4 way with 200 amps rated bus bar 240 volts double door with locking system complete all as specified
S & F Air termination single pointed, copper rod 12 mm dia and 300 mm long with necessary fixing arrangements on roof of bldg complete all as specified and as directed.
Supply and fixing test point terminal block made of gun metal or phosphorus bronze size 75x75x25 mm drilled and screwed including hex. Head screw 3 Nos 8 mm dia 25 mm long complete all as specified and as directed.
Supply and fixing Copper strip 20 x3.0 mm with saddles and fixing screws etc for roof conductors and down conductors above ground with necessary arrangements on the roof/wall for fixing copper strip complete all as specified and as directed.
Supply and fix copper strip 32 x 6 mm thick as continuity earth lead from Air terminal point to test terminal point complete all as specified and as directed.
S & F ceiling rose three terminal surface bakelite type AC 50 Hz 230 Volts of size 65 x 50 mm complete all as specified and as directed.
Earthing complete with galvanised steel earth plate electrode 60cm x60cm x6mm thick buried directly in ground earth pit not less than 2.25 mtr deep with top edge of plate not less than 1.5m below ground level, connecting to the Galvanised iron earth earth lead 4 mm dia, by means of nuts, bolts, check nuts and washer etc of galvanised iron and earth lead protected by provision of GI pipe med grade 15mm bore from earth elelctrode to test point incl provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone agagregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4Kg/Sqm) and frame of angle iron 25 x 25x6mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, GI pipe med grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, test point with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning in and removal of surplus soil to a distance not exceeding 50mtr, all as per electrical plate No 5 of Part-I and connection to earth test point all as specified incl testing on completion. Note :- Item of Earthing includes cost of 7.5m long galvanised iron earth lead 4 mm size and protection pipe of 15 mm bore GI light grade complete all as specified and as directed.
Earthing complete with copper earth plate electrode 60cmx60cmx3.15mm thick electrode buried directly in ground earth pit not less than 2.25 m deep below normal ground level) with top edge of earth plate not less than 1.5 m below ground level connected to copper earth strip 20x3 mm by means of bolts, nuts, check nuts and washers etc of galvanised iron and earth lead protected by provision of GI pipe 40 mm bore of medium grade from earth electrode to test point incl provn of concrete pit in PCC(1:2:4) type B-1 using 20 mm graded stone aggregate with 40 mm thick cover of RCC (1:2:4) reinforced with XPM (Weight not less than 4 Kg/Sqm) PCC cover with handle and with 6 mm dia MS bar handle made to shape, GI pipe medium grade 20 mm bore pipe for watering perforated at bottom1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling test point made out of Bronze/Gun metal with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning in and removal of surplus soil to a distance not exceeding 50 mtr, all as per Electricalplate No 5 of Part-I and connection to earth test point all as specified incl testing on completion. (Note: Item of Earthing includes cost of 7.5 mtr long copper earth strip 20x3 mm size and protection pipe 40 mm bore GI medium grade.
Supply and fix galvanised strip 32 x 6 mm thick as continuity earth lead from Air terminal point to test terminal point all as directed and specified.
Supply and fix copper strip 20 x 3.15 mm thick as continue earth lead from copper earth plate to test terminal point all as directed and specified.
S & Fix ceiling fan regulator step type AC 240 volt suitable for 1200/1400 mm sweep.
M & L for Submain wiring with two single core 4 Sq mm PVC insulated cable FRLS type copper conductor multistranded 1100 Volts grade drawn through and including rigid PVC conduit and conduit accessories of 25 mm dia medium grade including running up of 4 Sq mm copper conductor multistranded PVC insulated cable as earth continuity conductor along the wiring and connected to the common earth dolly complete including removing the existing unserviceable sub main wiring and making good the disturbed surface to match with the existing all as specified. Note:-two runs of cable, one run of earth contuinity conductor and one run of conduit shall be measured and paid as one unit length complete all as specified and as directed.
M & L for Submain wiring with two runs 6 Sq mm PVC insulated FRLS copper conductor multistranded 1100 Volts grade drawn through and including rigid PVC concealed conduit and conduit accessories of 25 mm dia medium grade including running up of 6 Sq mm copper conductor multistranded PVC insulated cable as earth continuity conductor along the wiring and connected to the common earth dolly complete including removing the existing unserviceable sub main wiring and making good the disturbed surface to match with the existing all as specified. Note:-Two runs of cable, one run of earth contuinity conductor and one run of conduit shall be measured and paid as one unit length complete all as specified and as directed.
M & L for Submain wiring with four runs 10 Sq mm PVC insulated cable FRLS type copper conductor multistranded 1100 Volts grade drawn through and including rigid PVC conduit and conduit accessories of 25 mm dia medium grade including running up of 10 Sq mm copper conductor multistranded PVC insulated cable as earth continuity conductor along the wiring and connected to the common earth dolly complete including removing the existing unserviceable sub main wiring and making good the disturbed surface to match with the existing all as specified. Note:-four runs of cable, one run of earth contuinity conductor and one run of conduit shall be measured and paid as one unit length.
S & F MCB SP 6 to 32 Amps 240 volts for fixing in MCB DB's all as specified.
S & F MCB SPN 40-63 Amps 240 volts for fixing on MCB DB's all as specified
Taking down the existing unserviceable main switch / cut out / DBs of any type / capacity / description as per existing at site including making good the disturbed surfaces to match with the existing finishes all as specified.
Supply and Lay GI tubing medium grade 40 mm dia 1.5 RM length incl PCC 1:2:4 on roof with necessary fixing arrangements all as specified and directed.
S & F Switch piano two way flush type 5 Amps capacity 230 volts complete all as specified and as directed..
S&F sheet metal enclosure vertical type MCB DB TPN 4 way double door with 200 Amps rated bus bar 415 volts suitable for and including 63 Amps TPN MCCB 16 KA as incommer and 12 Outgoing SP MCB's with magnetic locking system complete all as specified. Note: MCB SP Shall be measured and paid seperately, complete all as specified and as directed.
M&L for removing and refixing the ceiling fan of size 1200/1400mm sweep from any height after rewinding with super enamelled new copper wire of suitable gauge and weight as per manufacture's design, varnishing, fixing of new items like capacitor 2.5 mfd, sealed ball bearing, rubber bushes, cotter pins, check nuts flexible wire of suitable size with multistranded copper wire including fillig of cavaties with filler, spray painting with synthetic enamel paint all as specified and as directed. Note : All the items required as deemed to be included in the rate quoted and no items will be measured separately under any other item. The old unserviceable copper scrap wire will be taken by the contractor and will be measured under schedule of credit complete all as specified and as directed.
M&L for cutting of wall in round shape and making hole suitable for mounting of 300mm / 450mm dia exhaust fan and making good disturbed surfaces mactching with existing colour including grouting of nuts and bolts complete all as specified and as directed..
S & F Exhaust fan of metal body 300mm sweep with metallic louver including connecting up of PVC insulated copper conductor multistranded cable of suitable size as recommended by the manufacture form ceiling net 800 GSM, hole size on inch, thickness 3 mm green colour on the outside wall in between the louver and wall complete all as specified and as directed.
S & F Exhaust fan of metal body 450mm sweep with metallic louver including connecting up of PVC insulated copper conductor multistranded cable of suitable size as recommended by the manufacture form ceiling net 800 GSM, hole size on inch, thickness 3 mm green colour on the outside wall in between the louver and wall complete all as specified and as directed.
M & L for bracket made out of GI pipe of suitable dia not less than 1.2 mtr long and fixed on walls with 2 nos MS clamps made out of MS flat of suitable size thick complete with MS nuts, bolts and washers etc bent to required shape for cutting on wall in round shape using machine cutting only and making opening, at any height, fixing of premoulded block of required diameter suitable for mounting 300mm dia exhaust fan including making good the disturbed surface, plastering, matching with existing colour and clearing all debris from work site all as specified and as directed. Note. The contractor should check the site requirement for proper execution of work. The quoted rate includes for all/any number of openings required at any place for proper ventilation of the site complete all as specified and directed by Engg-in-Charge.
S&F of Provn of cable TV socket outlet point including conduit 20mm dia upto 15m long to reach out the intake point complete all as specified and as directed.
S & F down rods of 20mm dia including threads length complete suitable for ceiling fans of size 1200 mm sweep including clamps, nut & bolts as specified and as per site requirement complete all as specified and as directed.
S & F Air termination multi pointed copper lighting arrester 1 metre height with necessary base for fixing arrangements on roof of bldg all as specified and as directed.
Supply and fixing LED lights fitting 1x 18 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
S & F lamp holder insulated body surface bakelite including LED lamp of 7 watt with back platesuitable for angle/batten fittings fixed with wooden round blocks complete all as specified.
S & F wall mounted LED batten of 10 watt with LED Lamp, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver as per havels cat part No ENDURALINEARNEOBS10WLED865SPCW or equivelent make as specified here in after.
S&F LED bed side light fitting with lamp capacity 7W, 6500K adjustable type including all accessories as per havels cat part No HEXAFT10WELD857SSYMBOPC or equivelent make as specifed complete all as specified here in after.
S & F LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size.as per havels cat part NoLHEEGBPGPH1W007 equivelent make as specified here in after.
S & F Security Lights of 1x25 watt LED light with high power LED and unique peanut lens to ensure uniform distribution and including provision of 1.5 sqmm 3 core multistranded copper conductor cable from light fitting to junction box as per havels cat part No ENDURALINEARNEOBS25WLED765PASYBOTGIHD or equivelent make as specifed complete all as specified here in after
S & F wall mounted box type LED of 20 watt with LED Lamp, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver complete with 2 Nos round blocks with necessary fixing arrangements and connecting to the point wiring with necessary flexible copper conductor multistranded three core of suitable length & size from fitting to the ceiling rose as per havels cat part No LUMILINEBS20WLED865SPCWH or equivelent make as specifed complete all as specified here in after
S & F 36 watt recess softline luminaire (2x2) suitable for armstrong/grid ceiling with high brightness white LEDs and PMMA extruded diffuser giving glare free light and good aesthetic appeal and all including taking down as directed by Engg in charge Make : Make : PLAN02X2PLR36WLED865S
S & F Socket outlet flush type multipurpose 2/3 pin 5A, 230 V all as directed and specified.
S & F modualr switch 1 way 6A, 1 module capacity 230 V all as directed and specified.
S & F modular socket 6/16 A, 2/3 combined 2 module of capacity 230 V all as directed and specified.
S & F modular bell push 6A 1 module of capacity 230 V all as directed and specified. NOTE: For item No. 196,197 and 198 Modular cover plate with frame, modular metal flush box and modular switches will be inclusive of rate quoted
M & L for point wiring in concealed conduit complete all as specified with 1100 V grade. 1.5 sqmm PVC wire multistranded copper conductors FRLS conforming to IS : 694:1990 with ISI marking (for Phase. Neutral and Earth) in and including Non metallic PVC rigid conduit medium grad with ISI mark of 20mm dia with all accessories concealed in wall /ceiling/floor/roof etc, for fixing modular switches, sockets fan requlators etc of suitalbe moudles with modular boxes and front plate earth wire to be connected to common earth dolly including fixing/grouting sunken/surface as per site requirement including running up of 1.5 Sqmm copper condutor to the common earth dolly for fixing the switches / sockets requlators etc complete all as specified and as directed for the following:- one light point controlled by one, one way switch 5A, SP
All as per item No. 198, here in before but one ceiling/exhaust fan point controlled by one, one way switch
All as per item No. 198, here in before but one bell point controlled by one bell push
All as per item No. 198, here in before but one 2/3 pin 5 Amps switch socket outlet point controlled by one swtich on the same board
All as per item No. 198, here in before but one 2/3 pin 5 Amps switch socket outlet point controlled by one swtich on the independent board
All as per item No. 198, here in before but using 4 Sq mm single core copper conductor cable of multistranded PVC insulated FRLS 1100 Volts grade for 5/15 Amps switch socket combination point including running of 4 Sq mm copper conductor PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly complete all as specified and as directed. NOTE: For item No. 198 to 203 Modular cover plate with frame modular metal flush box will be inclusive of rate quoted
NEWS CONSTRUCTIONS
G.MADAN MOHAN
VACON INFRASTRUCTURES
BEEGEE DESIGN SYSTEMS
K LAKSHMAN SINGH AND CO
Vara Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .