Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance JAMMU KASHMIR HORTICULTURAL PRODUCE MARKETING PROCESSING CORPORATION JKHPMC LTD HORTICULTURE DEPARTMENT JAMMU KASHMIR GOVERNMENT OPPOSITE PRESENTATION CONVENT SCHOOL RAJBAGH J K190008 | SRINAGAR | JAMMU AND KASHMIR | 190008 | Admitted-Finance |
Tender Value
₹12 L
EMD Value
₹24,000
Closing Date
6 Jul 2020, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Er Pawan Tickoo
Executive Engineer PWD RandB Electric Div Jammu
please refer to BOQ
2020_PWDJK_98858_1
Fresh e-NIT No. EDJ/22 of 2020-21 Dated 20-06-2020
Open Tender
Electrical Works
Item Rate
30 days
Govt Model Girls Hr School Rajouri
please refer to NIT
2 documents required · 2 mandatory
₹600
Yes
Executive Engineer PWD RandB Electric Div Jammu
₹24,000
Yes
8 Dec 2020
24 Jun 2020
7 Jul 2020
25 Jun 2020
6 Jul 2020
25 Jun 2020
120 days
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Supplying and drawing following sizes of FRLS PVC insulated copper condcutor, Single core cable in the existing surface/PVC conduit as required.
1 x 1.5 Sq.mm
2x10+1x6 Sq.mm
2 X 2.5 Sq.mm 1 x 2.5 Sq.mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface /recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 modular switch, connections etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
12 way , Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single Pole
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 8 Module (125mmX125mm)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 amps switch
3 pin 5/6 amp socket outlet
15 Amps. Switch
6 pin 15/16 A socket outlet
Bell push
Supplying and fixing of following electrical items.
MCB SPN 63 Amp.
MCB SPN 40 Amp.
Fan Regulator
Aluminium Cable 16 Sq.mm twin core
Supplying & fixing of 20/22 watt LED 4 feet tube light fitting/fixture CRCA housing with 2000 Lumens and min lumens efficiency 100 Lumens/watt P.F 70.95 THD < 16% & voltage input range 140-270 V with Shot circuit & overloading protection circuit off
Supplying of bulk head fitting, water proof and suitable for outdoor use. The fitting shall complete with one No. 8 watt compact fluorescent lamp. The work involves assembly, fixing , connecting commissioning & testing of the fixture.
Supplying and fixing of Ceiling Fans 1200 mm Sweep along with fan rod upto 1'-6" long (5 Star).
Supplying & fixing 45 watt LED street light fittinghaving aluminium housing with heat resistant toughtened glass IP 65 protection complete with the suitable size GI pipe bracket duly embedded/ fixed in the wall/parapet & wiring with 2x1.5 sq. mm + 1x1.5 sq. mm FRLS PVC insulated copper conductor single core cable.
Supplying & fixing of 1650 VA Power invertors with 150 AH Batteries 48 months warranty complete with trolley (Tubular Batteries).
Supply of 100 kVA continous rating, 11kV/ 433V, 3 phase , 50Hz,Dyn-11 vector group, step down, out door type, copper wound, ONAN type transformers complete with with all accessories, fittings and conforming to specifications. Transformer shall have cable end box for 11 kV XPLE cable on HT side and Cable chamber on medium voltage side. The tap changing range shall be from + 5% to- 5% in step of 1.25%.
Supply, erection and commissioning of 2 pole structure for terminating 11 kV O.H supply from SEB as per specifications and drawing. The two pole structures hall comprise of :- . MS tubular Swaged pole 9 mtrs high (410 SP 24 as per latest IS:2713) ,in cement concrete foundation 1:3:6 (1 cement: 3 coarse sand: 6 graded aggregate 40 mm nominal size) including excavation and refilling etc as required. The rate shall be inclusive of painting with 2 coats of red oxide primer and 2 coats of aluminium paint. The portion of pole under the ground shall be provided with 2 coats of bituminous paint.- Nos 2 Steel sections, channels angles, flats, clamps, GI nuts, bolts and required hardware etc of different sizes for cross arms, bracings, supports etc for pole, GOD etc including anticlimbing barbed wires (conforming to IS: 278) having 4 points barbs spaced 75±12 mm apart. All steel structure shall be given 2 coats of re doxide primer and 2 finishing coats of Aluminium paint as required as per drgs and direction of Engineer- in-Charge. - Lot Supply, installation, testing and commissioning of 11kV class disc / pin/ support insulators complete with clamps and fixing hardware set complete as required as per drgs and direction of Engineer- in-Charge - Lot Supply, installation, testing and commissioning of 11 kV station class thyrite type lightning arrestors complete with mounting arrangement (on all phases) -3 nos.
Supply, installation, testing and commissioning of drop out– lock out (DOLO) fuse, gang operating device (Air Break Switch) with pad locking arrangement (operating rod to be supported properly), complete with operating handle and locking arrangement – Set 1 Supply, installation, testing and commissioning of GI stay set complete with 20mm dia 1.8M long stay rod with 450 x 450 x 7.5 mm anchor plate with thimbles, stay clamps, 7/4.00mm dia GI stay wire, turn buckle (20mmx600mm) strain insulator bow tightner in cement concrete 1:3:6 foundation as excavation and refilling etc.– Set 2. Two Pole Structure as above.
Providing & fixing 11 KV CT & PT for above metering outdoor unit in existing two pole structure and getting them calibrated amd Jammu state electricity board before fixing
Supplying and Laying of XLPE insulated and PVC sheathed aluminium conductor armoured Power Cable Heavy duty as perIS 7098 part -1 with latest ammendments up to date of following rating direct on surface or in ground including excavation and refiling the trench etc as required.
70 Sq.mm x 3.5 Core Armoured
120 Sq.mm x 3.5 Core Armoured
185 Sq.mm x 3.5 Core Armoured
abdul qayoom
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .