Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.6 CrAccepted-Finance | ₹7.6 Cr | L1 | Accepted-Finance Lowest Rate |
| 2 | L2₹8.3 Cr+₹67.9 L (8.88%)Rejected-Finance A 1 BLOCK A ASTHA APRTMENT BHOJUBEER NEAR CIRCUIT HOUSE VARANASI UTTAR PRADESH 221002 UDYAM UP 75 0008931 | VARANASI | UTTAR PRADESH | 221002 | ₹8.3 Cr+₹67.9 L (8.88%) | L2 | Rejected-Finance Highest Rate |
| 3 | Rejected-Technical | - | - | Rejected-Technical Document found Not ok |
| 4 | Rejected-Technical | - | - | Rejected-Technical Document found Not ok |
Tender Value
₹8.4 Cr
EMD Value
₹8.4 L
Closing Date
3 May 2023, 12:00 pmClosed
Superintending Engineer Electricity Work Circle Mi
Superintending Engineer Electricity Work Circle Mirzapur
The work of undergrounding of electric lines of Maa Vindhyavaisni Dham at New VIP Road , Old VIP Road, Kotwali Gali, Ghat Road and Mandir Parisar in Mirzapur Under the deposit scheme on Turn-key Basis
2023_PVVNV_798126_1
08/EWC(M)/2023-24
Open Tender
Construction Works
Lump-sum
180 days
Superintending Engineer Electricity Work Circle Mi
Please Refer Tender Document
2 documents required · 2 mandatory
₹5,900
Superintending Engineer Electricity Work Circle
₹8.4 L
20 May 2023
20 Apr 2023
4 May 2023
20 Apr 2023
3 May 2023
20 Apr 2023
Amount
Supply of Materials for Under Ground Cabling Work at New VIP Road in Mirzapur
Transformer 400 kva Supply . of 11/0.433 K.V. Copper Wound Transformers with O.L.T.C. & R.T.C.C. Panel at Site as per BEE Latest Specifications Star Rating (Star-1), effective from 1st July 2017, which is same as B.I.S.-1180 (Part-1)-2014, Level-2. and as per latest specification of UP Power Corporations, make prefered Crompton,Schneider or any Equivalent make with all material as per Technical Requirment with 05 years warranty
VCB PANNEL Supply of indoor type 11 kV VCB panel, totally enclosed fully interlocked, metal clad floor mounting, horizontal draw out type with metering arrangement, and 1 Incoming & 2 Outgoing HT Switchgear of Vacuum Circuit Breaker (VCB) including Surge Protection Device (SPD) on incomer & Earth Switch on outgoings, made out of 2 mm thick sheet steel for load bearing member and 1.6mm thick for non-load bearing member with all necessary protections, multi function meters . (Including Materials from 3.01 to 3.20)
A. Extended Busbar/Adoptor for internconnection from busbar of existing HT panel with all allied accessories, adoptors etc for below stated rating
1600 A,11KV,3 P, 50 Hz ,1 MVA Copper Busbar
B. Panel shall be comprising of:
1- Metal Clad housing with track having 1000A TP integral VCB with Electric operated draw out type mechanism (spring charged motor - 230 VAC).
1- Set of air insulated copper bus bar & chamber.
1- Set of isolating plug and receptacle.
1- Set of Automatic safety shutter.
1- Set of breaker control switch (TNC)
2- Sets of CT's
CT- I -630/400/5A class 5P-10(15 VA)
CT- II - 630/400/5A class -1(15 VA)
1 - H.T. Cable box for 3C x 300 sq.mm aluminium conductor XLPE cable (11 KV earthed system).
1 - No. Tripping coil & closing Coil 24V DC/110V A.C.
1 - Set of ON/OFF/Trip & circuit healthy and phase indicating lights.
1- 3 element O/C, EF & SC relay (IDMTL & Hi - set) with required setting.
1- set Auxiliary relay.
1- Master trip relay
1-set Trip circuit supervision
1-Restricted Earth fault relay
Incoming - 1000Amp /415 Volt ACB -1 No.
Bus Bar - 1000 Amp /415 Volt AL -1 No.
Outgoing - 400 Amp FP MCCB - 6 Nos.
Incoming - 400Amp /415 Volt MCCB -1 No.
Bus Bar - 400 Amp /415 Volt AL -1 No.
Outgoing - (1) 100- Amp FP MCCB - 6 Nos. (2) 32 Amp FP MCCB - 1 Nos.
Chemical Earthing Supply of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000mm, outer Dia 50 mm inner Dia 25 mm, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with rystalline conductive mixture (CCM) having anti corrosive & onductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25mm x 3mm G.I. strip, upto switch board (from apron to witch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing.
Supply of 25mmx3mm G.I. Strip
Supply of one number 8 SWG G.I. wire
Supply of 3 core standered aluminium conductor XLPE (Cross linked polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cables
11 KV 3x185 sq. mm XLPE Cable 3 core
Supply of indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :
11 KV Cable Jointing Kit Outdoor 3x185 sq. mm XLPE Cable.
Supply of outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :
11 KV Cable Jointing Kit Indoor 3x185 sq. mm XLPE Cable.
Cables Supply of aluminium conductor PVC insulated armoured served sheathed cable 1100 volts.
size 4 sq mm x 4 core
size 6 sq mm x 4 core
size 10 sq mm x 4 core
size 16 sq mm x 4 core
size 120 sq mm x 3-1/2core
Supply of brass nickle plated compression gland for pvc insulated & armoured served sheaththed ,underground cable including rubber ring etc.
size 4 sq mm x 4 core
size 6 sq mm x 4 core
size 10 sq mm x 4 core
size 16 sq mm x 4 core
size 120 sq mm x 3-1/2core
Supply of plain or pin type copper tin plated cable socket (lug) to cable leads for pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cable
size 4 sq mm
size 6 sq mm
size 10 sq mm
size 16 sq mm
size 120 sq mm
Supply of HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.
200 mm dia (OD-200 mm & ID-175 mm nominal)
Supply of Danger Board fabricated from 10 gauge M.S. Sheet
Supply of shock treatment chart. framed with glass and supported from back with hard board or shoft board.
Supply of 1800*900*12mm thick chequerd rubber matting.
Supply of G.I. Barbed Wire
Supply of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 45 watt to 50 Watt.
Erection of above materials for Under Ground Cabling Work at New VIP Road in Mirzapur
Transformer 400 kva Errection . of 11/0.433 K.V. Copper Wound Transformers with O.L.T.C. & R.T.C.C. Panel at Site as per BEE Latest Specifications Star Rating (Star-1), effective from 1st July 2017, which is same as B.I.S.-1180 (Part-1)-2014, Level-2. and as per latest specification of UP Power Corporations, make prefered Crompton,Schneider or any Equivalent make Including construction of Plinth and earthing etc. with all material as per Technical Requirment with 05 years warranty (Fenching upto 3 mtr)
VCB PANNEL Errection, installation, testing & commissioning indoor type 11 kV VCB panel, totally enclosed fully interlocked, metal clad floor mounting, horizontal draw out type with metering arrangement, and 1 Incoming & 2 Outgoing HT Switchgear of Vacuum Circuit Breaker (VCB) including Surge Protection Device (SPD) on incomer & Earth Switch on outgoings, made out of 2 mm thick sheet steel for load bearing member and 1.6mm thick for non-load bearing member with all necessary protections, multi function meters . (Including Materials from 23.01 to 23.20)
A. Extended Busbar/Adoptor for internconnection from busbar of existing HT panel with all allied accessories, adoptors etc for below stated rating
1600 A,11KV,3 P, 50 Hz ,1 MVA Copper Busbar
B. Panel shall be comprising of:
1- Metal Clad housing with track having 1000A TP integral VCB with Electric operated draw out type mechanism (spring charged motor - 230 VAC).
1- Set of air insulated copper bus bar & chamber.
1- Set of isolating plug and receptacle.
1- Set of Automatic safety shutter.
1- Set of breaker control switch (TNC)
2- Sets of CT's
CT- I -630/400/5A class 5P-10(15 VA)
CT- II - 630/400/5A class -1(15 VA)
1 - H.T. Cable box for 3C x 300 sq.mm aluminium conductor XLPE cable (11 KV earthed system).
1 - No. Tripping coil & closing Coil 24V DC/110V A.C.
1 - Set of ON/OFF/Trip & circuit healthy and phase indicating lights.
1- 3 element O/C, EF & SC relay (IDMTL & Hi - set) with required setting.
1- set Auxiliary relay.
1- Master trip relay
1-set Trip circuit supervision
1-Restricted Earth fault relay
Incoming - 1000Amp /415 Volt ACB -1 No.
Bus Bar - 1000 Amp /415 Volt AL -1 No.
Outgoing - 400 Amp FP MCCB - 6 Nos.
Incoming - 400Amp /415 Volt MCCB -1 No.
Bus Bar - 400 Amp /415 Volt AL -1 No.
Outgoing - (1) 100- Amp FP MCCB - 6 Nos. (2) 32 Amp FP MCCB - 1 Nos.
Chemical Earthing Errection of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000mm, outer Dia 50 mm inner Dia 25 mm, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with rystalline conductive mixture (CCM) having anti corrosive & onductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25mm x 3mm G.I. strip, upto switch board (from apron to witch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing.
Errection of 25mmx3mm G.I. Strip from earth electrode in ground
Errection of one number 8 SWG G.I. wire in 15mm dia G.I. pipe for earthing, laid in ground or in wall duly concealed including the cost of cement, sand, labour, T & P other material required for proper completion of the work
Laying of 3 core standered aluminium conductor XLPE (Cross linked polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cables 11 KV grade at a depth of 900 mm below ground level over a cushion of 100 mm thick fine river sand all around and protected with well burnt bricks on sides and on top put across. The armouring of cable shall be properly connected with earth conductor by clamps etc.
11 KV 3x185 sq. mm XLPE Cable 3 core
Errection / making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :
11 KV Cable Jointing Kit Outdoor 3x185 sq. mm XLPE Cable.
Errection / making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :
11 KV Cable Jointing Kit Indoor 3x185 sq. mm XLPE Cable.
Cables laying of aluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size The armouring of the cable shall be properly connected with the earth conductor by clamps etc.Following size
size 4 sq mm x 4 core
size 6 sq mm x 4 core
size 10 sq mm x 4 core
size 16 sq mm x 4 core
size 120 sq mm x 3-1/2core
Errection/ fixing of brass nickle plated compression gland for pvc insulated & armoured served sheaththed ,underground cable including rubber ring etc. .Following size
size 4 sq mm x 4 core
size 6 sq mm x 4 core
size 10 sq mm x 4 core
size 16 sq mm x 4 core
size 120 sq mm x 3-1/2core
Errection/ fixing of plain or pin type copper tin plated cable socket (lug) to cable leads for pvc insulated & armoured cable insulating with tape and making connection.Following size
size 4 sq mm
size 6 sq mm
size 10 sq mm
size 16 sq mm
size 120 sq mm
laying of following size DWC HDPE pipe along with all accessories like socket, bend, couplers etc. complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc.
200 mm dia (OD-200 mm & ID-175 mm nominal)
Fixing of Danger Board fabricated from 10 gauge M.S. Sheet
Fixing of shock treatment chart. framed with glass and supported from back with hard board or shoft board.
Laying of 1800*900*12mm thick chequerd rubber matting.
Errection of G.I. Barbed Wire
Fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 45 watt to 50 Watt.
EXCAVATION in foundation in ordinary Soil ( Loam clay or sand ) including lift upto 1.5m lead upto 30.0 m & including filling watering and ramming of excavated earth into the space between the building & sides of foundation trenches or into the plinth and removal & disposal surplus earth I/C within a lead of 30 m.from foundation trenches.
CONCRETE Providing and laying Cement concrete 1:4:8 (1cement :4 coarse sand :8 graded stone ballast 20 mm. nominal size) including supply of all materials, labour and T&P etc. required for proper completion of the work and curing complete, also including cost of formwork in foundation.
REINFORCED CEMENT CONCRETE WORK Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately).
TMT BARS OF MINIMUM GRADE FE500 such as in reinforced concreted or reinforced brick work (when not included in overall rates) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage.Bend hooks and authorized overlapping shall be measured.
Supply of Materials for Under Ground Cabling Work at Old VIP Road in Mirzapur
Transformer 400 kva Supply . of 11/0.433 K.V. Copper Wound Transformers with O.L.T.C. & R.T.C.C. Panel at Site as per BEE Latest Specifications Star Rating (Star-1), effective from 1st July 2017, which is same as B.I.S.-1180 (Part-1)-2014, Level-2. and as per latest specification of UP Power Corporations, make prefered Crompton,Schneider or any Equivalent make with all material as per Technical Requirment with 05 years warranty
VCB PANNEL Supply of indoor type 11 kV VCB panel, totally enclosed fully interlocked, metal clad floor mounting, horizontal draw out type with metering arrangement, and 1 Incoming & 2 Outgoing HT Switchgear of Vacuum Circuit Breaker (VCB) including Surge Protection Device (SPD) on incomer & Earth Switch on outgoings, made out of 2 mm thick sheet steel for load bearing member and 1.6mm thick for non-load bearing member with all necessary protections, multi function meters . (Including Materials from 47.01 to 47.20)
A. Extended Busbar/Adoptor for internconnection from busbar of existing HT panel with all allied accessories, adoptors etc for below stated rating
1600 A,11KV,3 P, 50 Hz ,1 MVA Copper Busbar
B. Panel shall be comprising of:
1- Metal Clad housing with track having 1000A TP integral VCB with Electric operated draw out type mechanism (spring charged motor - 230 VAC).
1- Set of air insulated copper bus bar & chamber.
1- Set of isolating plug and receptacle.
1- Set of Automatic safety shutter.
1- Set of breaker control switch (TNC)
2- Sets of CT's
CT- I -630/400/5A class 5P-10(15 VA)
CT- II - 630/400/5A class -1(15 VA)
1 - H.T. Cable box for 3C x 300 sq.mm aluminium conductor XLPE cable (11 KV earthed system).
1 - No. Tripping coil & closing Coil 24V DC/110V A.C.
1 - Set of ON/OFF/Trip & circuit healthy and phase indicating lights.
1- 3 element O/C, EF & SC relay (IDMTL & Hi - set) with required setting.
1- set Auxiliary relay.
1- Master trip relay
1-set Trip circuit supervision
1-Restricted Earth fault relay
Incoming - 1000Amp /415 Volt ACB -1 No.
Bus Bar - 1000 Amp /415 Volt AL -1 No.
Outgoing - (1) 630 Amp FP ACB -2 Nos. (2) 400 Amp FP MCCB - 1 Nos. (3) 200 Amp FP MCCB - 2 Nos.
Incoming - 400Amp /415 Volt MCCB -1 No.
Bus Bar - 400 Amp /415 Volt AL -1 No.
Outgoing - (1) 100- Amp FP MCCB - 2 Nos. (2) 32 Amp FP MCCB - 16 Nos.
Chemical Earthing Supply of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000mm, outer Dia 50 mm inner Dia 25 mm, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with rystalline conductive mixture (CCM) having anti corrosive & onductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25mm x 3mm G.I. strip, upto switch board (from apron to witch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing.
Supply of 25mmx3mm G.I. Strip
Supply of one number 8 SWG G.I. wire
Supply of 3 core standered aluminium conductor XLPE (Cross linked polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cables
11 KV 3x185 sq. mm XLPE Cable 3 core
Supply of indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :
11 KV Cable Jointing Kit Outdoor 3x185 sq. mm XLPE Cable.
Supply of outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :
11 KV Cable Jointing Kit Indoor 3x185 sq. mm XLPE Cable.
Cables Supply of aluminium conductor PVC insulated armoured served sheathed cable 1100 volts.
size 4 sq mm x 4 core
size 6 sq mm x 4 core
size 10 sq mm x 4 core
size 16 sq mm x 4 core
size 120 sq mm x 3-1/2core
Supply of brass nickle plated compression gland for pvc insulated & armoured served sheaththed ,underground cable including rubber ring etc.
size 4 sq mm x 4 core
size 6 sq mm x 4 core
size 10 sq mm x 4 core
size 16 sq mm x 4 core
size 120 sq mm x 3-1/2core
Supply of plain or pin type copper tin plated cable socket (lug) to cable leads for pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cable
size 4 sq mm
size 6 sq mm
size 10 sq mm
size 16 sq mm
size 120 sq mm
Supply of HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.
200 mm dia (OD-200 mm & ID-175 mm nominal)
Supply of Danger Board fabricated from 10 gauge M.S. Sheet
Supply of shock treatment chart. framed with glass and supported from back with hard board or shoft board.
Supply of 1800*900*12mm thick chequerd rubber matting.
Supply of G.I. Barbed Wire
Supply of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 45 watt to 50 Watt.
Erection of above materials for Under Ground Cabling Work at Old VIP Road in Mirzapur
Transformer 400 kva Errection . of 11/0.433 K.V. Copper Wound Transformers with O.L.T.C. & R.T.C.C. Panel at Site as per BEE Latest Specifications Star Rating (Star-1), effective from 1st July 2017, which is same as B.I.S.-1180 (Part-1)-2014, Level-2. and as per latest specification of UP Power Corporations, make prefered Crompton,Schneider or any Equivalent make Including construction of Plinth and earthing etc. with all material as per Technical Requirment with 05 years warranty (Fenching upto 3 mtr)
VCB PANNEL Errection, installation, testing & commissioning indoor type 11 kV VCB panel, totally enclosed fully interlocked, metal clad floor mounting, horizontal draw out type with metering arrangement, and 1 Incoming & 2 Outgoing HT Switchgear of Vacuum Circuit Breaker (VCB) including Surge Protection Device (SPD) on incomer & Earth Switch on outgoings, made out of 2 mm thick sheet steel for load bearing member and 1.6mm thick for non-load bearing member with all necessary protections, multi function meters . (Including Materials from 68.01 to 68.20)
A. Extended Busbar/Adoptor for internconnection from busbar of existing HT panel with all allied accessories, adoptors etc for below stated rating
1600 A,11KV,3 P, 50 Hz ,1 MVA Copper Busbar
B. Panel shall be comprising of:
1- Metal Clad housing with track having 1000A TP integral VCB with Electric operated draw out type mechanism (spring charged motor - 230 VAC).
1- Set of air insulated copper bus bar & chamber.
1- Set of isolating plug and receptacle.
1- Set of Automatic safety shutter.
1- Set of breaker control switch (TNC)
2- Sets of CT's
CT- I -630/400/5A class 5P-10(15 VA)
CT- II - 630/400/5A class -1(15 VA)
1 - H.T. Cable box for 3C x 300 sq.mm aluminium conductor XLPE cable (11 KV earthed system).
1 - No. Tripping coil & closing Coil 24V DC/110V A.C.
1 - Set of ON/OFF/Trip & circuit healthy and phase indicating lights.
1- 3 element O/C, EF & SC relay (IDMTL & Hi - set) with required setting.
1- set Auxiliary relay.
1- Master trip relay
1-set Trip circuit supervision
1-Restricted Earth fault relay
Incoming - 1000Amp /415 Volt ACB -1 No.
Bus Bar - 1000 Amp /415 Volt AL -1 No.
Outgoing - (1) 630 Amp FP ACB -2 Nos. (2) 400 Amp FP MCCB - 1 Nos. (3) 200 Amp FP MCCB - 2 Nos.
Incoming - 400Amp /415 Volt MCCB -1 No.
Bus Bar - 400 Amp /415 Volt AL -1 No.
Outgoing - (1) 100- Amp FP MCCB - 2 Nos. (2) 32 Amp FP MCCB - 16 Nos.
Chemical Earthing Errection of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000mm, outer Dia 50 mm inner Dia 25 mm, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with rystalline conductive mixture (CCM) having anti corrosive & onductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25mm x 3mm G.I. strip, upto switch board (from apron to witch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing.
Errection of 25mmx3mm G.I. Strip from earth electrode in ground
Errection of one number 8 SWG G.I. wire in 15mm dia G.I. pipe for earthing, laid in ground or in wall duly concealed including the cost of cement, sand, labour, T & P other material required for proper completion of the work
Laying of 3 core standered aluminium conductor XLPE (Cross linked polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cables 11 KV grade at a depth of 900 mm below ground level over a cushion of 100 mm thick fine river sand all around and protected with well burnt bricks on sides and on top put across. The armouring of cable shall be properly connected with earth conductor by clamps etc.
11 KV 3x185 sq. mm XLPE Cable 3 core
Errection / making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :
11 KV Cable Jointing Kit Outdoor 3x185 sq. mm XLPE Cable.
Errection / making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :
11 KV Cable Jointing Kit Indoor 3x185 sq. mm XLPE Cable.
Cables laying of aluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size The armouring of the cable shall be properly connected with the earth conductor by clamps etc.Following size
size 4 sq mm x 4 core
size 6 sq mm x 4 core
size 10 sq mm x 4 core
size 16 sq mm x 4 core
size 120 sq mm x 3-1/2core
Errection/ fixing of brass nickle plated compression gland for pvc insulated & armoured served sheaththed ,underground cable including rubber ring etc. .Following size
size 4 sq mm x 4 core
size 6 sq mm x 4 core
size 10 sq mm x 4 core
size 16 sq mm x 4 core
size 120 sq mm x 3-1/2core
Errection/ fixing of plain or pin type copper tin plated cable socket (lug) to cable leads for pvc insulated & armoured cable insulating with tape and making connection.Following size
size 4 sq mm
size 6 sq mm
size 10 sq mm
size 16 sq mm
size 120 sq mm
laying of following size DWC HDPE pipe along with all accessories like socket, bend, couplers etc. complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc.
200 mm dia (OD-200 mm & ID-175 mm nominal)
Fixing of Danger Board fabricated from 10 gauge M.S. Sheet
Fixing of shock treatment chart. framed with glass and supported from back with hard board or shoft board.
Laying of 1800*900*12mm thick chequerd rubber matting.
Errection of G.I. Barbed Wire
Fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 45 watt to 50 Watt.
EXCAVATION in foundation in ordinary Soil ( Loam clay or sand ) including lift upto 1.5m lead upto 30.0 m & including filling watering and ramming of excavated earth into the space between the building & sides of foundation trenches or into the plinth and removal & disposal surplus earth I/C within a lead of 30 m.from foundation trenches.
CONCRETE Providing and laying Cement concrete 1:4:8 (1cement :4 coarse sand :8 graded stone ballast 20 mm. nominal size) including supply of all materials, labour and T&P etc. required for proper completion of the work and curing complete, also including cost of formwork in foundation.
REINFORCED CEMENT CONCRETE WORK Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately).
TMT BARS OF MINIMUM GRADE FE500 such as in reinforced concreted or reinforced brick work (when not included in overall rates) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage.Bend hooks and authorized overlapping shall be measured.
Supply of Materials for Under Ground Cabling Work at Kotwali Gali in Mirzapur
Transformer 400 kva Supply . of 11/0.433 K.V. Copper Wound Transformers with O.L.T.C. & R.T.C.C. Panel at Site as per BEE Latest Specifications Star Rating (Star-1), effective from 1st July 2017, which is same as B.I.S.-1180 (Part-1)-2014, Level-2. and as per latest specification of UP Power Corporations, make prefered Crompton,Schneider or any Equivalent make with all material as per Technical Requirment with 05 years warranty
VCB PANNEL Supply of indoor type 11 kV VCB panel, totally enclosed fully interlocked, metal clad floor mounting, horizontal draw out type with metering arrangement, and 1 Incoming & 3 Outgoing HT Switchgear of Vacuum Circuit Breaker (VCB) including Surge Protection Device (SPD) on incomer & Earth Switch on outgoings, made out of 2 mm thick sheet steel for load bearing member and 1.6mm thick for non-load bearing member with all necessary protections, multi function meters . (Including Materials from 92.01 to 92.20)
A. Extended Busbar/Adoptor for internconnection from busbar of existing HT panel with all allied accessories, adoptors etc for below stated rating
1600 A,11KV,3 P, 50 Hz ,1 MVA Copper Busbar
B. Panel shall be comprising of:
1- Metal Clad housing with track having 1000A TP integral VCB with Electric operated draw out type mechanism (spring charged motor - 230 VAC).
1- Set of air insulated copper bus bar & chamber.
1- Set of isolating plug and receptacle.
1- Set of Automatic safety shutter.
1- Set of breaker control switch (TNC)
2- Sets of CT's
CT- I -630/400/5A class 5P-10(15 VA)
CT- II - 630/400/5A class -1(15 VA)
1 - H.T. Cable box for 3C x 300 sq.mm aluminium conductor XLPE cable (11 KV earthed system).
1 - No. Tripping coil & closing Coil 24V DC/110V A.C.
1 - Set of ON/OFF/Trip & circuit healthy and phase indicating lights.
1- 3 element O/C, EF & SC relay (IDMTL & Hi - set) with required setting.
1- set Auxiliary relay.
1- Master trip relay
1-set Trip circuit supervision
1-Restricted Earth fault relay
Incoming - 1000Amp /415 Volt ACB -1 No.
Bus Bar - 1000 Amp /415 Volt AL -1 No.
Outgoing - (1) 630 Amp FP ACB -2 Nos. (2) 400 Amp FP MCCB - 1 Nos. (3) 200 Amp FP MCCB - 2 Nos.
Incoming - 400Amp /415 Volt MCCB -1 No.
Bus Bar - 400 Amp /415 Volt AL -1 No.
Outgoing - (1) 100- Amp FP MCCB - 10 Nos. (2) 32 Amp FP MCCB - 01 Nos.
Chemical Earthing Supply of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000mm, outer Dia 50 mm inner Dia 25 mm, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with rystalline conductive mixture (CCM) having anti corrosive & onductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25mm x 3mm G.I. strip, upto switch board (from apron to witch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing.
Supply of 25mmx3mm G.I. Strip
Supply of one number 8 SWG G.I. wire
Supply of 3 core standered aluminium conductor XLPE (Cross linked polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cables
11 KV 3x185 sq. mm XLPE Cable 3 core
Supply of indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :
11 KV Cable Jointing Kit Outdoor 3x185 sq. mm XLPE Cable.
Supply of outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :
11 KV Cable Jointing Kit Indoor 3x185 sq. mm XLPE Cable.
Cables Supply of aluminium conductor PVC insulated armoured served sheathed cable 1100 volts.
size 4 sq mm x 4 core
size 6 sq mm x 4 core
size 10 sq mm x 4 core
size 16 sq mm x 4 core
size 120 sq mm x 3-1/2core
Supply of brass nickle plated compression gland for pvc insulated & armoured served sheaththed ,underground cable including rubber ring etc.
size 4 sq mm x 4 core
size 6 sq mm x 4 core
size 10 sq mm x 4 core
size 16 sq mm x 4 core
size 120 sq mm x 3-1/2core
Supply of plain or pin type copper tin plated cable socket (lug) to cable leads for pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cable
size 4 sq mm
size 6 sq mm
size 10 sq mm
size 16 sq mm
size 120 sq mm
Supply of HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.
200 mm dia (OD-200 mm & ID-175 mm nominal)
Supply of Danger Board fabricated from 10 gauge M.S. Sheet
Supply of shock treatment chart. framed with glass and supported from back with hard board or shoft board.
Supply of 1800*900*12mm thick chequerd rubber matting.
Supply of G.I. Barbed Wire
Supply of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 45 watt to 50 Watt.
Erection of above materials for Under Ground Cabling Work at Kotwali Gali in Mirzapur
Transformer 400 kva Errection . of 11/0.433 K.V. Copper Wound Transformers with O.L.T.C. & R.T.C.C. Panel at Site as per BEE Latest Specifications Star Rating (Star-1), effective from 1st July 2017, which is same as B.I.S.-1180 (Part-1)-2014, Level-2. and as per latest specification of UP Power Corporations, make prefered Crompton,Schneider or any Equivalent make Including construction of Plinth and earthing etc. with all material as per Technical Requirment with 05 years warranty (Fenching upto 3 mtr)
VCB PANNEL Errection, installation, testing & commissioning indoor type 11 kV VCB panel, totally enclosed fully interlocked, metal clad floor mounting, horizontal draw out type with metering arrangement, and 1 Incoming & 3 Outgoing HT Switchgear of Vacuum Circuit Breaker (VCB) including Surge Protection Device (SPD) on incomer & Earth Switch on outgoings, made out of 2 mm thick sheet steel for load bearing member and 1.6mm thick for non-load bearing member with all necessary protections, multi function meters . (Including Materials from 113.01 to 113.20)
A. Extended Busbar/Adoptor for internconnection from busbar of existing HT panel with all allied accessories, adoptors etc for below stated rating
1600 A,11KV,3 P, 50 Hz ,1 MVA Copper Busbar
B. Panel shall be comprising of:
1- Metal Clad housing with track having 1000A TP integral VCB with Electric operated draw out type mechanism (spring charged motor - 230 VAC).
1- Set of air insulated copper bus bar & chamber.
1- Set of isolating plug and receptacle.
1- Set of Automatic safety shutter.
1- Set of breaker control switch (TNC)
2- Sets of CT's
CT- I -630/400/5A class 5P-10(15 VA)
CT- II - 630/400/5A class -1(15 VA)
1 - H.T. Cable box for 3C x 300 sq.mm aluminium conductor XLPE cable (11 KV earthed system).
1 - No. Tripping coil & closing Coil 24V DC/110V A.C.
1 - Set of ON/OFF/Trip & circuit healthy and phase indicating lights.
1- 3 element O/C, EF & SC relay (IDMTL & Hi - set) with required setting.
1- set Auxiliary relay.
1- Master trip relay
1-set Trip circuit supervision
1-Restricted Earth fault relay
Incoming - 1000Amp /415 Volt ACB -1 No.
Bus Bar - 1000 Amp /415 Volt AL -1 No.
Outgoing - (1) 630 Amp FP ACB -2 Nos. (2) 400 Amp FP MCCB - 1 Nos. (3) 200 Amp FP MCCB - 2 Nos.
Incoming - 400Amp /415 Volt MCCB -1 No.
Bus Bar - 400 Amp /415 Volt AL -1 No.
Outgoing - (1) 100- Amp FP MCCB - 10 Nos. (2) 32 Amp FP MCCB - 01 Nos.
Chemical Earthing Errection of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000mm, outer Dia 50 mm inner Dia 25 mm, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with rystalline conductive mixture (CCM) having anti corrosive & onductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25mm x 3mm G.I. strip, upto switch board (from apron to witch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing.
Errection of 25mmx3mm G.I. Strip from earth electrode in ground
Errection of one number 8 SWG G.I. wire in 15mm dia G.I. pipe for earthing, laid in ground or in wall duly concealed including the cost of cement, sand, labour, T & P other material required for proper completion of the work
Laying of 3 core standered aluminium conductor XLPE (Cross linked polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cables 11 KV grade at a depth of 900 mm below ground level over a cushion of 100 mm thick fine river sand all around and protected with well burnt bricks on sides and on top put across. The armouring of cable shall be properly connected with earth conductor by clamps etc.
11 KV 3x185 sq. mm XLPE Cable 3 core
Errection / making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :
11 KV Cable Jointing Kit Outdoor 3x185 sq. mm XLPE Cable.
Errection / making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :
11 KV Cable Jointing Kit Indoor 3x185 sq. mm XLPE Cable.
Cables laying of aluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size The armouring of the cable shall be properly connected with the earth conductor by clamps etc.Following size
size 4 sq mm x 4 core
size 6 sq mm x 4 core
size 10 sq mm x 4 core
size 16 sq mm x 4 core
size 120 sq mm x 3-1/2core
Errection/ fixing of brass nickle plated compression gland for pvc insulated & armoured served sheaththed ,underground cable including rubber ring etc. .Following size
size 4 sq mm x 4 core
size 6 sq mm x 4 core
size 10 sq mm x 4 core
size 16 sq mm x 4 core
size 120 sq mm x 3-1/2core
Errection/ fixing of plain or pin type copper tin plated cable socket (lug) to cable leads for pvc insulated & armoured cable insulating with tape and making connection.Following size
size 4 sq mm
size 6 sq mm
size 10 sq mm
size 16 sq mm
size 120 sq mm
laying of following size DWC HDPE pipe along with all accessories like socket, bend, couplers etc. complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc.
200 mm dia (OD-200 mm & ID-175 mm nominal)
Fixing of Danger Board fabricated from 10 gauge M.S. Sheet
Fixing of shock treatment chart. framed with glass and supported from back with hard board or shoft board.
Laying of 1800*900*12mm thick chequerd rubber matting.
Errection of G.I. Barbed Wire
Fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 45 watt to 50 Watt.
EXCAVATION in foundation in ordinary Soil ( Loam clay or sand ) including lift upto 1.5m lead upto 30.0 m & including filling watering and ramming of excavated earth into the space between the building & sides of foundation trenches or into the plinth and removal & disposal surplus earth I/C within a lead of 30 m.from foundation trenches.
CONCRETE Providing and laying Cement concrete 1:4:8 (1cement :4 coarse sand :8 graded stone ballast 20 mm. nominal size) including supply of all materials, labour and T&P etc. required for proper completion of the work and curing complete, also including cost of formwork in foundation.
REINFORCED CEMENT CONCRETE WORK Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately).
TMT BARS OF MINIMUM GRADE FE500 such as in reinforced concreted or reinforced brick work (when not included in overall rates) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage.Bend hooks and authorized overlapping shall be measured.
Supply of Materials for Under Ground Cabling Work at Ghat Road in Mirzapur
Transformer 400 kva Supply . of 11/0.433 K.V. Copper Wound Transformers with O.L.T.C. & R.T.C.C. Panel at Site as per BEE Latest Specifications Star Rating (Star-1), effective from 1st July 2017, which is same as B.I.S.-1180 (Part-1)-2014, Level-2. and as per latest specification of UP Power Corporations, make prefered Crompton,Schneider or any Equivalent make with all material as per Technical Requirment with 05 years warranty
VCB PANNEL Supply of indoor type 11 kV VCB panel, totally enclosed fully interlocked, metal clad floor mounting, horizontal draw out type with metering arrangement, and 1 Incoming & 2 Outgoing HT Switchgear of Vacuum Circuit Breaker (VCB) including Surge Protection Device (SPD) on incomer & Earth Switch on outgoings, made out of 2 mm thick sheet steel for load bearing member and 1.6mm thick for non-load bearing member with all necessary protections, multi function meters . (Including Materials from 137.01 to 137.20)
A. Extended Busbar/Adoptor for internconnection from busbar of existing HT panel with all allied accessories, adoptors etc for below stated rating
1600 A,11KV,3 P, 50 Hz ,1 MVA Copper Busbar
B. Panel shall be comprising of:
1- Metal Clad housing with track having 1000A TP integral VCB with Electric operated draw out type mechanism (spring charged motor - 230 VAC).
1- Set of air insulated copper bus bar & chamber.
1- Set of isolating plug and receptacle.
1- Set of Automatic safety shutter.
1- Set of breaker control switch (TNC)
2- Sets of CT's
CT- I -630/400/5A class 5P-10(15 VA)
CT- II - 630/400/5A class -1(15 VA)
1 - H.T. Cable box for 3C x 300 sq.mm aluminium conductor XLPE cable (11 KV earthed system).
1 - No. Tripping coil & closing Coil 24V DC/110V A.C.
1 - Set of ON/OFF/Trip & circuit healthy and phase indicating lights.
1- 3 element O/C, EF & SC relay (IDMTL & Hi - set) with required setting.
1- set Auxiliary relay.
1- Master trip relay
1-set Trip circuit supervision
1-Restricted Earth fault relay
Incoming - 1000Amp /415 Volt ACB -1 No.
Bus Bar - 1000 Amp /415 Volt AL -1 No.
Outgoing - (1) 630 Amp FP ACB -2 Nos. (2) 400 Amp FP MCCB - 1 Nos. (3) 200 Amp FP MCCB - 2 Nos.
Incoming - 400Amp /415 Volt MCCB -1 No.
Bus Bar - 400 Amp /415 Volt AL -1 No.
Outgoing - (1) 100- Amp FP MCCB - 6 Nos. (2) 32 Amp FP MCCB - 01 Nos.
Chemical Earthing Supply of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000mm, outer Dia 50 mm inner Dia 25 mm, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with rystalline conductive mixture (CCM) having anti corrosive & onductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25mm x 3mm G.I. strip, upto switch board (from apron to witch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing.
Supply of 25mmx3mm G.I. Strip
Supply of one number 8 SWG G.I. wire
Supply of 3 core standered aluminium conductor XLPE (Cross linked polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cables
11 KV 3x185 sq. mm XLPE Cable 3 core
Supply of indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :
11 KV Cable Jointing Kit Outdoor 3x185 sq. mm XLPE Cable.
Supply of outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :
11 KV Cable Jointing Kit Indoor 3x185 sq. mm XLPE Cable.
Cables Supply of aluminium conductor PVC insulated armoured served sheathed cable 1100 volts.
size 4 sq mm x 4 core
size 6 sq mm x 4 core
size 10 sq mm x 4 core
size 16 sq mm x 4 core
size 120 sq mm x 3-1/2core
Supply of brass nickle plated compression gland for pvc insulated & armoured served sheaththed ,underground cable including rubber ring etc.
size 4 sq mm x 4 core
size 6 sq mm x 4 core
size 10 sq mm x 4 core
size 16 sq mm x 4 core
size 120 sq mm x 3-1/2core
Supply of plain or pin type copper tin plated cable socket (lug) to cable leads for pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cable
size 4 sq mm
size 6 sq mm
size 10 sq mm
size 16 sq mm
size 120 sq mm
Supply of HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.
200 mm dia (OD-200 mm & ID-175 mm nominal)
Supply of Danger Board fabricated from 10 gauge M.S. Sheet
Supply of shock treatment chart. framed with glass and supported from back with hard board or shoft board.
Supply of 1800*900*12mm thick chequerd rubber matting.
Supply of G.I. Barbed Wire
Supply of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 45 watt to 50 Watt.
Erection of above materials for Under Ground Cabling Work at Ghat Road in Mirzapur
Transformer 400 kva Errection . of 11/0.433 K.V. Copper Wound Transformers with O.L.T.C. & R.T.C.C. Panel at Site as per BEE Latest Specifications Star Rating (Star-1), effective from 1st July 2017, which is same as B.I.S.-1180 (Part-1)-2014, Level-2. and as per latest specification of UP Power Corporations, make prefered Crompton,Schneider or any Equivalent make Including construction of Plinth and earthing etc. with all material as per Technical Requirment with 05 years warranty (Fenching upto 3 mtr)
VCB PANNEL Errection, installation, testing & commissioning indoor type 11 kV VCB panel, totally enclosed fully interlocked, metal clad floor mounting, horizontal draw out type with metering arrangement, and 1 Incoming & 3 Outgoing HT Switchgear of Vacuum Circuit Breaker (VCB) including Surge Protection Device (SPD) on incomer & Earth Switch on outgoings, made out of 2 mm thick sheet steel for load bearing member and 1.6mm thick for non-load bearing member with all necessary protections, multi function meters . (Including Materials from 157.01 to 157.20)
A. Extended Busbar/Adoptor for internconnection from busbar of existing HT panel with all allied accessories, adoptors etc for below stated rating
1600 A,11KV,3 P, 50 Hz ,1 MVA Copper Busbar
B. Panel shall be comprising of:
1- Metal Clad housing with track having 1000A TP integral VCB with Electric operated draw out type mechanism (spring charged motor - 230 VAC).
1- Set of air insulated copper bus bar & chamber.
1- Set of isolating plug and receptacle.
1- Set of Automatic safety shutter.
1- Set of breaker control switch (TNC)
2- Sets of CT's
CT- I -630/400/5A class 5P-10(15 VA)
CT- II - 630/400/5A class -1(15 VA)
1 - H.T. Cable box for 3C x 300 sq.mm aluminium conductor XLPE cable (11 KV earthed system).
1 - No. Tripping coil & closing Coil 24V DC/110V A.C.
1 - Set of ON/OFF/Trip & circuit healthy and phase indicating lights.
1- 3 element O/C, EF & SC relay (IDMTL & Hi - set) with required setting.
1- set Auxiliary relay.
1- Master trip relay
1-set Trip circuit supervision
1-Restricted Earth fault relay
Incoming - 1000Amp /415 Volt ACB -1 No.
Bus Bar - 1000 Amp /415 Volt AL -1 No.
Outgoing - (1) 630 Amp FP ACB -2 Nos. (2) 400 Amp FP MCCB - 1 Nos. (3) 200 Amp FP MCCB - 2 Nos.
Incoming - 400Amp /415 Volt MCCB -1 No.
Bus Bar - 400 Amp /415 Volt AL -1 No.
Outgoing - (1) 100- Amp FP MCCB - 06 Nos. (2) 32 Amp FP MCCB - 01 Nos.
Chemical Earthing Errection of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000mm, outer Dia 50 mm inner Dia 25 mm, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with rystalline conductive mixture (CCM) having anti corrosive & onductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25mm x 3mm G.I. strip, upto switch board (from apron to witch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing.
Errection of 25mmx3mm G.I. Strip from earth electrode in ground
Errection of one number 8 SWG G.I. wire in 15mm dia G.I. pipe for earthing, laid in ground or in wall duly concealed including the cost of cement, sand, labour, T & P other material required for proper completion of the work
Laying of 3 core standered aluminium conductor XLPE (Cross linked polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cables 11 KV grade at a depth of 900 mm below ground level over a cushion of 100 mm thick fine river sand all around and protected with well burnt bricks on sides and on top put across. The armouring of cable shall be properly connected with earth conductor by clamps etc.
11 KV 3x185 sq. mm XLPE Cable 3 core
Errection / making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :
11 KV Cable Jointing Kit Outdoor 3x185 sq. mm XLPE Cable.
Errection / making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :
11 KV Cable Jointing Kit Indoor 3x185 sq. mm XLPE Cable.
Cables laying of aluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size The armouring of the cable shall be properly connected with the earth conductor by clamps etc.Following size
size 4 sq mm x 4 core
size 6 sq mm x 4 core
size 10 sq mm x 4 core
size 16 sq mm x 4 core
size 120 sq mm x 3-1/2core
Errection/ fixing of brass nickle plated compression gland for pvc insulated & armoured served sheaththed ,underground cable including rubber ring etc. .Following size
size 4 sq mm x 4 core
size 6 sq mm x 4 core
size 10 sq mm x 4 core
size 16 sq mm x 4 core
size 120 sq mm x 3-1/2core
Errection/ fixing of plain or pin type copper tin plated cable socket (lug) to cable leads for pvc insulated & armoured cable insulating with tape and making connection.Following size
size 4 sq mm
size 6 sq mm
size 10 sq mm
size 16 sq mm
size 120 sq mm
laying of following size DWC HDPE pipe along with all accessories like socket, bend, couplers etc. complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc.
200 mm dia (OD-200 mm & ID-175 mm nominal)
Fixing of Danger Board fabricated from 10 gauge M.S. Sheet
Fixing of shock treatment chart. framed with glass and supported from back with hard board or shoft board.
Laying of 1800*900*12mm thick chequerd rubber matting.
Errection of G.I. Barbed Wire
Fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 45 watt to 50 Watt.
EXCAVATION in foundation in ordinary Soil ( Loam clay or sand ) including lift upto 1.5m lead upto 30.0 m & including filling watering and ramming of excavated earth into the space between the building & sides of foundation trenches or into the plinth and removal & disposal surplus earth I/C within a lead of 30 m.from foundation trenches.
CONCRETE Providing and laying Cement concrete 1:4:8 (1cement :4 coarse sand :8 graded stone ballast 20 mm. nominal size) including supply of all materials, labour and T&P etc. required for proper completion of the work and curing complete, also including cost of formwork in foundation.
REINFORCED CEMENT CONCRETE WORK Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately).
TMT BARS OF MINIMUM GRADE FE500 such as in reinforced concreted or reinforced brick work (when not included in overall rates) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage.Bend hooks and authorized overlapping shall be measured.
Supply of Materials for Under Ground Cabling Work at Mandir Parisar in Mirzapur
Transformer 250 kva Supply . of 11/0.433 K.V. Copper Wound Transformers with O.L.T.C. & R.T.C.C. Panel at Site as per BEE Latest Specifications Star Rating (Star-1), effective from 1st July 2017, which is same as B.I.S.-1180 (Part-1)-2014, Level-2. and as per latest specification of UP Power Corporations, make prefered Crompton,Schneider or any Equivalent make with all material as per Technical Requirment with 05 years warranty
VCB PANNEL Supply of indoor type 11 kV VCB panel, totally enclosed fully interlocked, metal clad floor mounting, horizontal draw out type with metering arrangement, and 1 Incoming & 2 Outgoing HT Switchgear of Vacuum Circuit Breaker (VCB) including Surge Protection Device (SPD) on incomer & Earth Switch on outgoings, made out of 2 mm thick sheet steel for load bearing member and 1.6mm thick for non-load bearing member with all necessary protections, multi function meters . (Including Materials from 184.01 to 184.20)
A. Extended Busbar/Adoptor for internconnection from busbar of existing HT panel with all allied accessories, adoptors etc for below stated rating
1600 A,11KV,3 P, 50 Hz ,1 MVA Copper Busbar
B. Panel shall be comprising of:
1- Metal Clad housing with track having 1000A TP integral VCB with Electric operated draw out type mechanism (spring charged motor - 230 VAC).
1- Set of air insulated copper bus bar & chamber.
1- Set of isolating plug and receptacle.
1- Set of Automatic safety shutter.
1- Set of breaker control switch (TNC)
2- Sets of CT's
CT- I -630/400/5A class 5P-10(15 VA)
CT- II - 630/400/5A class -1(15 VA)
1 - H.T. Cable box for 3C x 300 sq.mm aluminium conductor XLPE cable (11 KV earthed system).
1 - No. Tripping coil & closing Coil 24V DC/110V A.C.
1 - Set of ON/OFF/Trip & circuit healthy and phase indicating lights.
1- 3 element O/C, EF & SC relay (IDMTL & Hi - set) with required setting.
1- set Auxiliary relay.
1- Master trip relay
1-set Trip circuit supervision
1-Restricted Earth fault relay
Chemical Earthing Supply of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000mm, outer Dia 50 mm inner Dia 25 mm, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with rystalline conductive mixture (CCM) having anti corrosive & onductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25mm x 3mm G.I. strip, upto switch board (from apron to witch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing.
Supply of 25mmx3mm G.I. Strip
Supply of one number 8 SWG G.I. wire
Supply of 3 core standered aluminium conductor XLPE (Cross linked polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cables
11 KV 3x185 sq. mm XLPE Cable 3 core
Supply of indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :
11 KV Cable Jointing Kit Outdoor 3x185 sq. mm XLPE Cable.
Supply of outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :
11 KV Cable Jointing Kit Indoor 3x185 sq. mm XLPE Cable.
Supply of HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.
200 mm dia (OD-200 mm & ID-175 mm nominal)
Supply of Danger Board fabricated from 10 gauge M.S. Sheet
Supply of shock treatment chart. framed with glass and supported from back with hard board or shoft board.
Supply of 1800*900*12mm thick chequerd rubber matting.
Supply of G.I. Barbed Wire
Supply of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 45 watt to 50 Watt.
Erection of above materials for Under Ground Cabling Work at Mandir Parisar in Mirzapur
Transformer 250 kva Errection . of 11/0.433 K.V. Copper Wound Transformers with O.L.T.C. & R.T.C.C. Panel at Site as per BEE Latest Specifications Star Rating (Star-1), effective from 1st July 2017, which is same as B.I.S.-1180 (Part-1)-2014, Level-2. and as per latest specification of UP Power Corporations, make prefered Crompton,Schneider or any Equivalent make Including construction of Plinth and earthing etc. with all material as per Technical Requirment with 05 years warranty (Fenching upto 3 mtr)
VCB PANNEL Errection, installation, testing & commissioning indoor type 11 kV VCB panel, totally enclosed fully interlocked, metal clad floor mounting, horizontal draw out type with metering arrangement, and 1 Incoming & 3 Outgoing HT Switchgear of Vacuum Circuit Breaker (VCB) including Surge Protection Device (SPD) on incomer & Earth Switch on outgoings, made out of 2 mm thick sheet steel for load bearing member and 1.6mm thick for non-load bearing member with all necessary protections, multi function meters . (Including Materials from 199.01 to 199.20)
A. Extended Busbar/Adoptor for internconnection from busbar of existing HT panel with all allied accessories, adoptors etc for below stated rating
1600 A,11KV,3 P, 50 Hz ,1 MVA Copper Busbar
B. Panel shall be comprising of:
1- Metal Clad housing with track having 1000A TP integral VCB with Electric operated draw out type mechanism (spring charged motor - 230 VAC).
1- Set of air insulated copper bus bar & chamber.
1- Set of isolating plug and receptacle.
1- Set of Automatic safety shutter.
1- Set of breaker control switch (TNC)
2- Sets of CT's
CT- I -630/400/5A class 5P-10(15 VA)
CT- II - 630/400/5A class -1(15 VA)
1 - H.T. Cable box for 3C x 300 sq.mm aluminium conductor XLPE cable (11 KV earthed system).
1 - No. Tripping coil & closing Coil 24V DC/110V A.C.
1 - Set of ON/OFF/Trip & circuit healthy and phase indicating lights.
1- 3 element O/C, EF & SC relay (IDMTL & Hi - set) with required setting.
1- set Auxiliary relay.
1- Master trip relay
1-set Trip circuit supervision
1-Restricted Earth fault relay
Chemical Earthing Errection of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000mm, outer Dia 50 mm inner Dia 25 mm, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with rystalline conductive mixture (CCM) having anti corrosive & onductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25mm x 3mm G.I. strip, upto switch board (from apron to witch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing.
Errection of 25mmx3mm G.I. Strip from earth electrode in ground
Errection of one number 8 SWG G.I. wire in 15mm dia G.I. pipe for earthing, laid in ground or in wall duly concealed including the cost of cement, sand, labour, T & P other material required for proper completion of the work
Laying of 3 core standered aluminium conductor XLPE (Cross linked polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cables 11 KV grade at a depth of 900 mm below ground level over a cushion of 100 mm thick fine river sand all around and protected with well burnt bricks on sides and on top put across. The armouring of cable shall be properly connected with earth conductor by clamps etc.
11 KV 3x185 sq. mm XLPE Cable 3 core
Errection / making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :
11 KV Cable Jointing Kit Outdoor 3x185 sq. mm XLPE Cable.
Errection / making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :
11 KV Cable Jointing Kit Indoor 3x185 sq. mm XLPE Cable.
laying of following size DWC HDPE pipe along with all accessories like socket, bend, couplers etc. complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc.
200 mm dia (OD-200 mm & ID-175 mm nominal)
Fixing of Danger Board fabricated from 10 gauge M.S. Sheet
Fixing of shock treatment chart. framed with glass and supported from back with hard board or shoft board.
Laying of 1800*900*12mm thick chequerd rubber matting.
Errection of G.I. Barbed Wire
Fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 45 watt to 50 Watt.
EXCAVATION in foundation in ordinary Soil ( Loam clay or sand ) including lift upto 1.5m lead upto 30.0 m & including filling watering and ramming of excavated earth into the space between the building & sides of foundation trenches or into the plinth and removal & disposal surplus earth I/C within a lead of 30 m.from foundation trenches.
CONCRETE Providing and laying Cement concrete 1:4:8 (1cement :4 coarse sand :8 graded stone ballast 20 mm. nominal size) including supply of all materials, labour and T&P etc. required for proper completion of the work and curing complete, also including cost of formwork in foundation.
REINFORCED CEMENT CONCRETE WORK Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately).
TMT BARS OF MINIMUM GRADE FE500 such as in reinforced concreted or reinforced brick work (when not included in overall rates) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage.Bend hooks and authorized overlapping shall be measured.
M/S Grid Power Systems
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .