Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.4 LAccepted-AOC 8 28 BIJOYGARH P O JADAVPUR KOLKATA 700 032 | KOLKATA | WEST BENGAL | 700032 | ₹35.4 L Quoted ₹36.1 L | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹36.7 L+₹60,934 (1.69%)Rejected-Finance 63 47 49 1ST FLOOR BAKRAHAT ROAD THAKURPUKUR KOLKATA 700063 | KOLKATA | WEST BENGAL | 700063 | ₹36.7 L+₹60,934 (1.69%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹37.1 L+₹96,164 (2.66%)Rejected-Finance 8 27 BEJOYGARH JADAVPUR KOLKATA 700 032 | KOLKATA | WEST BENGAL | 700032 | ₹37.1 L+₹96,164 (2.66%) | L3 | Rejected-Finance Other than lowest |
| 4 | L4₹39.2 L+₹3.1 L (8.49%)Rejected-Finance TIORKHALI MAHESHGANJ NADIA | NADIA | NADIA | WEST BENGAL | 790804 | ₹39.2 L+₹3.1 L (8.49%) | L4 | Rejected-Finance Other than lowest |
| 5 | L5₹39.9 L+₹3.8 L (10.5%)Rejected-Finance 6 NALAPUKUR LANE FLAT 2C SENHATI COLONY KOLKATA 700034 WEST BENGAL | KOLKATA | WEST BENGAL | 700034 | ₹39.9 L+₹3.8 L (10.5%) | L5 | Rejected-Finance Other than lowest |
Tender Value
₹32.5 L
EMD Value
₹65,000
Closing Date
24 Sept 2021, 6:00 pmClosed
GE(FW) KOLKATA
D9 COMMISSARIAT ROAD HASTINGS KOLKATA 700022
REPAIR/MAINTENANCE OF SUB MAIN WIRING, POINT WIRING AND REPAIR/MAINTENANCE OF CEILING FANS, EXHAUST FANS, PEDESTAL FANS AND ALLIED WORKS INSIDE FORT WILLIAM UNDER GE (FW) KOLKATA
2021_MES_454406_3
GE(FW)/8739/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
FORT WILLIAM KOLKATA
AS PER NIT
6 documents required · 6 mandatory
₹500
Yes
GE(FW) KOLKATA
₹65,000
Yes
11 Oct 2021
18 Sept 2021
25 Sept 2021
18 Sept 2021
24 Sept 2021
18 Sept 2021
Amount
SCHEDULE 'A PART-I (INT ELECTRIFICATION) Taking down copper/ aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceilling roses, pendants, regulators, sockets etc excluding light fitting for taking credit removing from site and making good disturbed surface of walls, floors etc.complete all as specified and directed.
Materials and Labour for surface type point wiring with 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC casing capping medium duty complete with all fittings and accessories, fixed to walls/ceiling, including mild steel terminal boxes 1.25 mm thick conforming to IS-5133 (Part-I) with 3.0 mm thick plastic laminated sheet top cover (ISI Marked) for mounting switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly, for one light point /bell point/ceiling fan/exhaust fan point controlled by one way switch complete all as specified and directed.
All as per item No. 02 above but for one 5 amps switch socket outlet on same board controlled by another switch, complete all as specified and directed (surface type point wiring with terminal box).
All as per item No. 02 above but for one 5 amps switch socket combination on independent board, complete all as specified and directed (surface type point wiring with terminal box).
All as per item No. 02 above but using 2.5 sqmm single core multi stranded copper conductor FRLS-H PVC insulated and unsheathed, cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with and incl 2.5 sqmm green FRLS PVC insulated and unsheathed, copper conductor as continuous earth wire with lugs complete all as specified and directed (surface type point wiring with terminal box).
Materials and Labour for concealed type point wiring with 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC conduit complete with all fittings and accessories, fixed to walls/ceiling, including mild steel terminal boxes 1.25 mm thick conforming to IS-5133 (Part-I) with 3.0 mm thick plastic laminated sheet top cover (ISI Marked) for mounting switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly, for one light point /bell point/ ceiling fan/exhaust fan point controlled by one way switch complete all as specified and directed. (NOTES: - (i) Where tube light fitting is to be fitted/suspended, CI Circular boxes shall be provided with the PVC Pipes in the ceiling & the unit rate shall be deemed to be included for the same. (ii) Cost of cutting chases for concealed wiring shall be deemed to be inclusive in the quoted rates. No claim in this regard shall be entertained at a later stage)
All as per item No. 06 above but for one 5 amps switch socket outlet on same board controlled by another switch, complete all as specified and directed (concealed type point wiring with terminal box).
All as per item No. 06 above but for one 5 amps switch socket combination on independent board, complete all as specified and directed (concealed type point wiring with terminal box).
All as per item No. 06 above but using 2.5 sqmm single core multi stranded copper conductor FRLS-H PVC insulated and unsheathed, cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with and incl 2.5 sqmm green FRLS-H PVC insulated and unsheathed, copper conductor as continuous earth wire with lugs complete all as specified and directed (concealed type point wiring with terminal box).
Materials and Labour for surface type point wiring with 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC casing capping complete with all fittings and accessories, (except terminal box and laminate cover), fixed to walls/ceiling, for mounting MODULAR TYPE switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly for One light point or one fan point or bell point controlled by one switch or bell push complete all as specified and directed. (NOTE :- Quoted rate shall be exclusive of the cost of terminal box & laminate cover which shall be measured seperately.
All as per item No. 10 above but for one 5 amps switch socket outlet on same board controlled by another switch, complete all as specified and directed (surface type point wiring without terminal box).
All as per item No. 10 above but for one 5 amps switch socket combination on independent board, complete all as specified and directed (surface type point wiring without terminal box).
All as per item No 10 above but using 2.50 Sq. mm (nominal area) FRLS PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core for line conductor and 2.50 Sq. mm (nominal area) FRLS PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core for earth continuty wire for one 15/16 amp multi socket out let independent (surface type point wiring without terminal box).
M&L for concealed type point wiring with 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and incl PVC conduit complete with all fittings and accessories (except terminal box and laminate cover), fixed to walls/ceiling, for mounting MODULAR TYPE switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly for One light point or one fan point or bell point controlled by one switch or bell push complete all as specified and directed. (NOTE :- (i) Where tube light fitting is to be fitted/ suspended, CI Circular boxes shall be provided with the PVC Pipes in the ceiling & the unit rate shall be deemed to be included for the same. (ii) Quoted rate shall be exclusive of the cost of terminal box & laminate cover which shall be measured seperately. (iii) Cost of cutting chases for concealed wiring shall be deemed to be inclusive in the quoted rates. No claim in this regard shall be entertained at a later stage)
All as per item No 14 here-in-before but for one 5 pin 5/6 amps multisocket outlet point in independent board (concealed wiring) (except terminal box and laminate cover), fixed to walls/ceiling, for mounting MODULAR TYPE switches
All as per item No 14 here-in-before but for one 5 pin 5/6 amp socket out let point in the same switch board of light points (except terminal box and laminate cover), fixed to walls/ceiling, for mounting MODULAR TYPE switches
All as per item No 14 above but using 2.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core for line conductor and 2.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core for earth continuty wire for one 15/16 amp multi socket out let independent. (concealed wiring) (except terminal box and laminate cover), fixed to walls/ceiling, for mounting MODULAR TYPE switches
Materials and Labour for concealed type point wiring with 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in existing PVC conduit complete with all fittings and accessories, fixed to walls/ceiling, including mild steel terminal boxes 1.25 mm thick conforming to IS-5133 (Part-I) with 3.0 mm thick plastic laminated sheet top cover (ISI Marked) for mounting switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly, for one light point /bell point/ ceiling fan/exhaust fan point controlled by one way switch complete all as specified and directed. (NOTE: Wiring shall be done in existing conduit. Quoted rate shall be excusive of the cost of conduit)
All as per item No. 18 above but for one 5 amps switch socket combination on independent board, complete all as specified and directed (concealed type point wiring with terminal box in existing conduit).
All as per item No. 18 above but using 2.5 sqmm single core multi stranded copper conductor FRLS-H PVC insulated and unsheathed, cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with and incl 2.5 sqmm green FRLS-H PVC insulated and unsheathed, copper conductor as continuous earth wire with lugs complete all as specified and directed (concealed type point wiring with terminal box in existing conduit).
Materials and Labour for concealed type point wiring with 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in existing PVC conduit complete with all fittings and accessories (except terminal box and laminate cover), fixed to walls/ceiling, for mounting MODULAR TYPE switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly for One light point or one fan point or bell point controlled by one switch or bell push complete all as specified and directed. (NOTE: Wiring shall be done in existing conduit. Quoted rate shall be excusive of the cost of conduit)
All as per item No 21 here-in-before but for one 5 pin 5/6 amps multisocket outlet point in independent board (concealed wiring in existing conduit) (except terminal box and laminate cover), fixed to walls/ceiling, for mounting MODULAR TYPE switches
All as per item No 21 above but using 2.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core for line conductor and 2.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core for earth continuty wire for one 15/16 amp multi socket out let independent. (concealed wiring in existing conduit) (except terminal box and laminate cover), fixed to walls/ceiling, for mounting MODULAR TYPE switches
PIANO SWITCH, 5/6 AMPS, SINGLE POLE, ONE WAY
S & F new Switch piano, flush type
Re-fixing of switch piano, any type (retrieved from taking down of point wiring)
PIANO SWITCH, 15/16 AMPS, SINGLE POLE, ONE WAY
S & F new Switch piano, flush type
Re-fixing of switch piano, any type (retrieved from taking down of point wiring)
SOCKET OUTLET, 6 IN 1, 3 PIN, 6/16 AMPS,
S & F new socket outlet, flush type
Re-fixing of socket outlet, 6/16 Amps any type (retrieved from taking down of point wiring)
SWITCH SOCKET COMBINATION OUTLET, 6 IN 1, 3 PIN, 6/16 AMPS,
S & F new switch socket combination outlet, flush type with indicator lamp
Re-fixing of switch socket combination outlet, 6/16 Amps any type (retrieved from taking down of point wiring)
SOCKET OUTLET, 5 PIN, 5/6 AMPS,
S & F new socket outlet, flush type
Re-fixing of socket outlet, 5/6 Amps any type (retrieved from taking down of point wiring)
SWITCH SOCKET COMBINATION OUTLET, 3/5 PIN, 5/6 AMPS,
S&F new switch socket combination outlet, flush type
Re-fixing of switch socket combination outlet, any type (retrieved from taking down of point wiring)
BELL PUSH, 5/6 AMPS, 240 VOLTS
S&F new Bell push, flush type
Re-fixing of bell push, any type (retrieved from taking down of point wiring)
CALL BELL/BUZZER, AC 230/240 VOLTS, SINGLE POLE
S&F new Call bell, musical type
S&F new Call bell, ding dong type
Re-fixing of Call bell, any type (retrieved from taking down of point wiring)
Re-fixing of electric call bell, ding donmg type (retrieved from taking down of point wiring)
CEILING ROSE, THREE TERMINALS, 240 VOLTS
S&F new Ceiling rose, surface type
Re-fixing of ceiling rose, any type (retrieved from taking down of point wiring)
FAN REGULATOR, STEPPED TYPE, 5 SPEED CONTROL, 230/240 VOLTS
S&F stepped type electronic fan regulator, flush type
Re-fixing of fan regulator, any type (retrieved from taking down of point wiring)
LAMP HOLDER, PVC/POLYCARBONATE BODY
S&F lamp holder with back plate suitable for batten/pendant fittings or to be mounted on walls
Re-fixing of lamp holder, any type (retrieved from taking down of point wiring)
MODULAR SWITCH, 5/6 AMPS, 1 MODULE, ONE WAY
S & F Modular Switch 1 way 6 A, 1 module
Re-fixing of modular switch, 5/6 Amps, 1 module (retrieved from taking down of point wiring)
MODULAR SWITCH, 16 AMPS, 1 MODULE, ONE WAY
S & F Modular Switch 1 way 16 A, 1 module
Re-fixing of modular switch, 16 Amps, 1 module (retrieved from taking down of point wiring)
MODULAR SOCKET, 6 AMPS, 2 MODULE
S & F Modular Socket 6 A, 2/3 pin combined 2 module
Re-fixing of modular socket, 6 Amps, 2 module (retrieved from taking down of point wiring)
MODULAR SOCKET, 16 AMPS, 2 MODULE
S & F Modular Socket 6 A/ 16 A, 2/3 pin combined 2 module
Re-fixing of modular socket, 6 A/ 16 A, 2/3 pin combined 2 module (retrieved from taking down of point wiring)
MODULAR FAN REGULATOR
S & F Modular Fan step regulator, 120 watt, 2 module
Re-fixing of modular Fan step regulator, 120 watt, 2 module (retrieved from taking down of point wiring)
MODULAR BELL PUSH
S & F Modular Bell push 6A, 1 module
Re-fixing of modular Bell push 6A, 1 module (retrieved from taking down of point wiring)
MODULAR BLANKING PLATE
S & F Modular Blank plate, 1 module
Re-fixing of modular Blank plate, 1 module (retrieved from taking down of point wiring)
MODULAR TYPE COVER PLATE WITH FRAME
S&F Modular White cover plate with frame 1 module
S&F Modular White cover plate with frame 2 module
S&F Modular White cover plate with frame 3 module
S&F Modular White cover plate with frame 4 module
S&F Modular White cover plate with frame 6 module
S&F Modular White cover plate with frame 8 module
S&F Modular White cover plate with frame 12 module
MODULAR TYPE METAL FLUSH BOX
S & F Modular type Metal Flush box 1/2 module
S & F Modular type Metal Flush box 3 module
S & F Modular type Metal Flush box 4 module
S & F Modular type Metal Flush box 6 module
S & F Modular type Metal Flush box 8 module
S & F Modular type Metal Flush box 12 module
S & F in repair Modular fittings/accessories in existing location complete all as specified & directed for the following types :-.
Modular Switch 1 way 6 A, 1 module, 240 Volts AC
Modular Switch 1 way 16 A, 1 module 240 Volts AC
Modular Socket 6 A, 2/3 pin combined 2 module, shuttered, 240 Volts AC
Modular Socket 6 / 16 A, 2/3 pin combined 2 module, shuttered, 240 Volts AC
Modular Fan step regulator, 120 watt, 2 module, 100W, 4 step, 240 Volts AC
Supply and fixing in repairs Skirting light with LED - 230 V - 3 module with necessary electrical connection with suitable size copper wire complete all as specified and directed. (Make : ANCHOR (WOODS), Cat No: 60253 / LEGRAND, Cat No; 675597 or equivalent model in HONEYWELL MK / ABB / SCHNEIDER / CRABTREE)
S&F in repairs surface mounted LED luminaire, 1 X 20 Watt in aluminium housing, operating voltage 180-270 V, with acrylic/polycarbonate difuser & integrated constant current electronic driver complete with all other accessories internally prewired and including connecting up with three core flexible copper wire of suitable size incl taking down existing fitting complete all as specified and directed. complying with the following specifications:- (a) minimum efficacy 110 lumen/watt (b) CRI not less than 80, (c) THD < 20% (c) having in built short circuit and surge protection (d) colour temperature not less than 5700 degree K (e) life not less than 25000 hours of operation
-ditto- as per Item No. 46 but of 1 X 9/10 Watt capacity in polycarbonate housing with lumen output not less than 105 lumen per watt
Supply and Fix in repairs recess mounted LED luminaire suitable for 600 x 600 mm snap grid ceiling, in powder coated CRCA housing , having glare free diffuser, operating voltage 180-270V, with constant current electronic driver complete with all accessories with and including 30 Watt LED and including all accessories, mounting frame etc and connecting up with three core flexible copper conductor wire of adequate size complete all as specified and directed and complying with the following specifications:- (a) minimum efficacy 110 lumen/watt (b) CRI not less than 80, (c) THD < 20% (c) having in built short circuit and surge protection (d) colour temperature not less than 5700 degree K (e) life not less than 25000 hours of operation (f) Weather protection: IP20
Supply and Fix in repairs surface mounted LED luminaire, of size 600 mm x 600 mm, in powder coated CRCA housing , having glare free diffuser, operating voltage 180-270V, with constant current electronic driver complete with all accessories with and including 36 Watt LED and including all accessories, mounting frame etc and connecting up with three core flexible copper conductor wire of adequate size complete all as specified and directed and complying with the following specifications:- (a) minimum efficacy 110 lumen/watt (b) CRI not less than 80, (c) THD < 20% (c) having in built short circuit and surge protection (d) colour temperature not less than 5700 degree K (e) life not less than 25000 hours of operation (f) Weather protection: IP20
Supply and Fix in repairs recess mounted LED luminaire, of size 600 mm x 600 mm, in powder coated CRCA housing , having glare free diffuser, operating voltage 180-270V, with constant current electronic driver complete with all accessories with and including 36 Watt LED and including all accessories, mounting frame etc and connecting up with three core flexible copper conductor wire of adequate size complete all as specified and directed and complying with the following specifications:- (a) minimum efficacy 110 lumen/watt (b) CRI not less than 80, (c) THD < 20% (c) having in built short circuit and surge protection (d) colour temperature not less than 5700 degree K (e) life not less than 25000 hours of operation (f) Weather protection: IP20
Supply and fixing in repairs suspended LED light fitting, 1X36 Watts, in aluminium extruded housing with and including LED tube rod 4 feet long suitable for single phase 230 Volts, 50 Hz AC supply complete with all accessories internally prewired and including connecting up with three core flexible copper conductor cable of size 1.5 sqmm (nominal area) and OEM suspension system complete all as specified and directed and complying with the following specifications:- (a) minimum efficacy 110 lumen/watt (b) CRI not less than 80, (c) THD < 10% (c) having in built short circuit and surge protection (d) colour temperature not less than 5700 degree K (e) life not less than 25000 hours of operation (f) Weather protection: IP20 (MAKE : HAVELLS, Model: SABER/ SURYA, Model: AURORA-I or equivalent model in other makes specified in tender)
Supply and Fix in repairs recess mounted LED flat panel luminaire, suitable for 300 mm x 300 mm snap grid ceiling, , in powder coated CRCA housing , having glare free diffuser, operating voltage 180-270V, with constant current electronic driver complete with all accessories with and including 15 Watt LED and including all accessories, mounting frame etc and connecting up with three core flexible copper conductor wire of adequate size complete all as specified and directed and complying with the following specifications:- (a) minimum efficacy 105 lumen/watt (b) CRI not less than 80, (c) THD < 20% (c) having in built short circuit and surge protection (d) colour temperature not less than 5700 degree K (e) life not less than 25000 hours of operation (f) Weather protection: IP20
-ditto- as per Item No. 52 but surface mounted LED flat panel type of capacity 15 Watt
Supply and Fix in repairs recess mounted slim-fit downlighter, round or square, having glare free frosted diffuser, operating voltage 180-270V, with constant current electronic driver complete with all accessories with and including 15 Watt LED and including all accessories, mounting frame etc and connecting up with three core flexible copper conductor wire of adequate size complete all as specified and directed and complying with the following specifications:- (a) minimum efficacy 105 lumen/watt (b) CRI not less than 80, (c) THD < 20% (c) having in built short circuit and surge protection (d) colour temperature not less than 5700 degree K (e) life not less than 25000 hours of operation (f) Weather protection: IP20
-ditto- as per Item No. 54 but surface mounted LED downlighter of capacity 15 Watt
S&F in repair thread type E-27 cool day LED bulb, 09 Watt, with aluminium heat sink powder coated white with PC diffuser, minimum colour temperature 5700K complete all as specified and directed.
S&F in repair thread type E-27 cool day LED bulb, 05 Watt, with aluminium heat sink powder coated white with PC diffuser, minimum colour temperature 5700K complete all as specified and directed.
S&F in repair thread type E-14 cool day LED bulb, 09 Watt, with aluminium heat sink powder coated white with PC diffuser, minimum colour temperature 5700K complete all as specified and directed.
S&F in repair thread type E-14 cool day LED bulb, 05 Watt, with aluminium heat sink powder coated white with PC diffuser, minimum colour temperature 5700K complete all as specified and directed.
Supply and fixing in repairs adjustable bed side LED lamp with clear lens, 3 watt, colour temperature 3000K incl electronic driver and other accessories and necessary electrical connection with suitable size copper wire complete all as specified and directed. (Make : PHILIPS, Cat No: 48042/30/31 or equivalent model in other makes specified in tender)
S&F in repair picture LED lights with colour temperature 3000K suitable for 10 watt metal and synthetic material lumen 500 Im incl driver and necessary electric connection with suitable size copper wire complete all as per specified and directed. (Make : PHILIPS, Cat No: 48043/30/86 or equivalent model in other makes specified in tender)
S & F in repair LED wall mounted spot focusing light fitting 3 watt, colour temperature 2700K, mounted on wall / ceiling connected with insulated unsheathed flexible copper wire of suitable size (length not exceeding 0.5 m) from ceiling rose complete all as specified and directed. (Make : Philips, Cat No. 56240/31 or equivalent model in other makes specified in tender)
S&F decorative wall mounted LED luminaire, with 2 X 4 watt E-27 lamps, clear glass gold finish with crystal duly connected with insulated unsheathed flexible copper wire of suitable size complete all as specified and directed (Make: JAQUAR, Cat No: JES-WHT-WL00002TAE14 -CHR-MB160275211A or equivalent model in other makes specified in tender)
Supply & fixing in repair decorative LED luminaire, opal glass with chrome finish with 1 x 4 watt, E-14 lamp mounted on wall duly connected with insulated unsheathed flexible copper wire of suitable size (length not more than 0.50 m) from ceiling rose complete all as specified and directed (Make: JAQUAR, Cat No: KCH-CHR-MB160275212A or equivalent model in other makes specified in tender)
S&F in repair LED Bulkhead fitting 10 watt, with IP65 degree of protection and with impact resistance of IK-08, mounted on wall /ceiling connected with insulated unsheathed flexible copper wire of suitable size including taking down existing fitting complete all as specified and directed.
S&F in repairs LED Bldg Security Light fitting 25W, in pressure die cast aluminium housing with PMMA lens and toughened glass/PC cover having TOP opening seperate driver compartmnent, with integrated constant current electronic driver, incl providing new GI pipe bracket as per existing size including necessary electrical connection with stuiable size copper wire complete all as specified and directed and complying with the following specifications:-. (a) minimum efficacy 110 lumen/watt (b) CRI not less than 70, (c) THD < 30% (c) having in built short circuit & surge protection upto 5 kV (d) colour temperature not less than 5700 degree K (e) life not less than 25000 hours of operation (f) Weather protection grade: IP66
NOTE FOR ITEM NO. 46 to 66 :- (1) List of approved makes has been provided in particular specifications. Contractor shall ensure that luminaire provided comply with the aforesaid specifications. No claim shall be entertained during currency of work. (2) Contractor has to furnish a replacement warranty of 02 years for LED light fittings complete incl lamps from the date of completion of work. The product will be replaced free of cost in following cases :- (a) Manufacturing Defects. (b) Failure due to mechanical and electrical impact. (c) Drop in lumen (or lux at 1 metre) below 90% of claimed value of lumen (or lux at 1 metre) of the LED/luminaire. (d) Decision of GE in this regard shall be final and binding. (3) All LED/luminaire shall meet the provision laid down in IS-16101, 16102 Part-I/II, 16103 Part-I, 16104, 16105, 16106, 16108/2012 and 15885 Part-II/Section 13. (4) The contractor shall submit the LM-80 and LM-79 test report (except decorative fitttings) as specified in Particular Specifications.
Repair/maintanance of ceiling fan of any sweep and any height by replacing unserviceable capacitor/ tightening the loose connections if any including testing complete all as directed by Engr-in-Charge (Note: Capacitor of required capacity will be measured & paid under relavent item here-in-after)
Taking down of AC ceiling fan of any sweep & any height and opening the fan and oiling, greasing, rewinding coil and replacement of unserviceable accessories and servicing, complete overhauling and re-assembling and testing complete by hanging in position as directed by the Engr-in-Charge.
Repair/maintanance of exhaust fan (of any sweep) and opening the fan and oiling, greasing, rewinding coil and replacement of unserviceable accessories and servicing, complete overhauling and re-assembling and testing complete by hanging in position as directed by the Engr-in-Charge.
Repair/maintanance of wall mounted fan (of any sweep) and opening the fan and oiling, greasing, rewinding coil and replacement of unserviceable accessories and servicing, complete overhauling and re-assembling and testing complete by hanging in position as directed by the Engr-in-Charge.
Repair/maintanance of pedestal fan (of any sweep) and opening the fan and oiling, greasing, rewinding coil and replacement of unserviceable accessories and servicing, complete overhauling and re-assembling and testing complete by hanging in position as directed by the Engr-in-Charge.
Painting of ceiling fan of 1200mm to 1400mm sweep of any size, with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc complete all as specified and as directed. (NOTE: Cost of taking down of serviceable fan for painting, if any, shall be deemed to be inclusive in the quoted rates)
Supply only capacitor (PVC body) of capacity 2.5 mfd
Supply only capacitor (PVC body) of capacity 3.15 mfd
Supply only capacitor (PVC body) of capacity 4/6 mfd
Supply only bearing for fans, any type or capacity complete all as specified and directed.
Supply only clamp with buckle for hanging ceiling fan including nuts and bolts and other accessories, suitable for any type of ceiling fan complete all as specified and directed.
S&F GI tubing medium grade of size 15 mm dia incl painting and making hole for extention of fan hook in high roof ceiling complete all as specified and directed.
Taking down of old Submain wiring any type including batten/ conduit/ casing at any indicated situation complete all as specified and directed.
M&L for sub main wiring with 4 run of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10.0 sqmm alongwith one run of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10.0 sqmm as earth continuity conductor drawn through and including PVC casing-caping of suitable size, surface type complete all as specified and directed. (NOTE : Five runs of single core 10.0 sqmm cable & one run of PVC casing capping shall be measured as one unit)
All as per Srl. Item No. 80 above but with two runs of 6.0 Sqmm cable and one run of 6.0 Sqmm as earth continuity conductor in PVC casing capping (NOTE : Three runs of single core 6.0 sqmm cable & one run of PVC casing capping shall be measured as one unit)
All as per Srl. Item No. 80 above but with two runs of 4.0 Sqmm cable and one run of 4.0 Sqmm as earth continuity conductor in PVC casing capping (NOTE : Three runs of single core 4.0 sqmm cable & one run of PVC casing capping shall be measured as one unit)
All as per Srl. Item No. 80 above but with two runs of 2.5 Sqmm cable and one run of 2.5 Sqmm as earth continuity conductor in PVC casing capping (NOTE : Three runs of single core 2.5 sqmm cable & one run of PVC casing capping shall be measured as one unit)
Material and labour for cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landing, steps, cills, sunshades, shelves, lintels etc and cutting chases for concealed water tubing or concealed water tubing or concealed conduit wiring etc and making good, cutting not exc 10 cm girth complete all as specified and directed.
Taking down of Old MCB DB any type any size including MCCB/RCCB/MCBs and disconnecting the serviceable MCBs and keeping in safe custody for reuse at site.
Supply and fixing TPN DB, IP 43 protection, double door (premium quality), 415 volts, 4 way (8+12), with 100 Amps copper bus bar for each phase complete all as specified and directed. (MAKE : L&T, Cat No. DBTPN004DD / LEGRAND, Cat No: 507670 / SCHNEIDER, Cat No. A9HTND04 / ABB, Cat No: E-SHDB M4 / PANASONIC, Cat No: BQS 304H / HAGER, Cat No: VYT04DH)
All as per Item No. 86 above 4 Way (8+12) TPN DB (normal quality) complete all as specified and directed. (MAKE : C&S, Cat No: CSDBTPNHPDD04 /BCH, Cat No: BCHHTPNDD04W / INDO ASIAN, Cat No: 811841 / HAVELLS, Cat No: DHDPTHODRW04 / HPL, Cat No: MDBTDD04)
S&F SPN DB, IP 43 protection, double door (Premium Quality), 240 volts, 4 way, with 100 Amps copper Bus Bar complete all as specified and directed. (MAKE : L&T, Cat No. DBSPN004DD / LEGRAND, Cat No: 507610 / ABB, Cat No. E-SHC M4 / SCHNEIDER, Cat No. NBKRENSNDD04 / HAGER, Cat No: VYS04D)
All as per Item No. 88 above 4 Way SPN DB (normal quality) complete all as specified and directed. (MAKE : C&S, Cat No; CSDBSPNPDD04 / BCH, Cat No: BCHSPNDD04W / HPL, Cat No: MDBDD04 / HAVELLS, Cat No: DHDPSHODRW04 / INDO ASIAN, Cat No: 811824)
Supply and Fix, Double Door, Sheet Metal Enclosure for DBs (Premium Quality), for mounting of MCB for 240 Volts, 8 way, with 100 Amps rated copper bus bar, Single Pole & Neutral, complete all as specified and directed. (MAKE : L&T, Cat No. DBSPN008DD / LEGRAND, Cat No: 507611 /ABB, Cat No. E-SHC M 8 / SCHNEIDER, Cat No. A9HSND08 / HAGER, Cat No: VYS08D)
All as per Item No. 90 above 8 Way SPN DB (normal quality) complete all as specified and directed. (MAKE : C&S, Cat No: CSDBSPNPDD08 / BCH, Cat No: BCHSPNDD08W / HPL, Cat No: MDBDD08 / HAVELLS, Cat No: DHDPSHODRW08 / INDO ASIAN, Cat No: 811807)
Refixing of MCB DB any type or any size and necessary electrical connections as directed by Engr-in-Charge.
NOTE FOR ITEM NO. 86 to 92 :- (1) Incoming MCCB/RCCB/MCB and outgoing MCBs shall be measured and paid seperately as "Supply Only". (2) Quoted rate is deemed to be inclusive of blanking plate for slots remaining blank after fixing of MCBs. (3) DB, MCCB, RCCB & MCB shall be of the same manufacturer.
S&F MCB (premium quality), 'C' series, TPN, 415 volts, 63 Amps, breaking capacity 10KA complete all as specified and directed. (MAKE : L&T / LEGRAND / SCHNEIDER / ABB / PANASONIC / HAGER)
S&F MCB (ordinary quality), 'C' series, TPN, 415 volts, 63 Amps, breaking capacity 10KA complete all as specified and directed. (MAKE : C&S / BCH / HPL / HAVELLS / INDO ASIAN)
S&F MCB (premium quality), 'C' series, SPN, 32 Amps, breaking capacity 10KA complete all as specified and directed. (MAKE : L&T / LEGRAND / SCHNEIDER / ABB / PANASONIC / HAGER)
S&F MCB (ordinary quality), 'C' series, SPN, 32 Amps, breaking capacity 10KA complete all as specified and directed. (MAKE : C&S / BCH / HPL / HAVELLS / INDO ASIAN)
S&F MCB (Premium Quality), 'C' series, single pole, 6 to 32 Amps, breaking capacity 10KA complete all as specified and directed. (MAKE : L&T / LEGRAND / SCHNEIDER / ABB / PANASONIC / HAGER)
S&F MCB (ordinary quality), 'C' series, single pole, 6 to 32 Amps, breaking capacity 10KA complete all as specified and directed. (MAKE : C&S / BCH / HPL / HAVELLS / INDO ASIAN)
Labour only for taking down and fixing of new/serviceable Isolator /RCCBs / MCBs any size or any type including electrical connections in existing DBs complete all as specified and directed by Engr-in-Charge. (NOTE :- RCCB/MCB shall be measured and paid seperately as "Supply Only").
S&F in repairs PVC casing/caping of size 25 mm with all accessories all as directed by Engr-in- charge .
S&F in repairs PVC casing/caping of size 20 mm with all accessories all as directed by Engr-in- charge .
S&F in repair LED driver for 2'x2' LED ceiling light fitting 230 Volt 30 watt - 40 watt complete all as specified and as directed.
S&F in repair LED driver for LED ceiling light fitting 230 Volt 18 watt - 28 watt complete all as specified and as directed.
S&F in repair LED driver for LED ceiling light fitting 230 Volt 05 watt - 15 watt complete all as specified and as directed.
S&F in repair LED driver for LED strip light, 230 Volt 5 W complete all as specified and as directed.
S&F in repair MODULAR MCB protected power unit with one 25 Amps socket with 3 pin plug top and including 01 No MCB, DP, and starter 25 Amps ratings with six module plate and flush metal GI box and electrically connected complete all as specified and directed. (MAKE : HAVELLS, Cat No. DHDUCDP0253025 / NORTH WEST, Cat No: ACPU6M-BT or equivalent model in ABB / CRABTREE / HAGER / SCHNEIDER / LEGRAND)
Supply and fixing in repairs single pole enclosure with two pin and earth plug and socket complete with one SP MCB, 20 Amps, 'C' Curve, 10 KA including all accesories complete all as specified and directed. (MAKE OF ENCLOSURE: LEGRAND, Cat No. 5078 10 / L&T, Cat No. DBMPS120SD / SCHNEIDER, Cat No: A9HMS220 / ABB, Cat No. NSYN8690SGKSP20 / C&S, Cat No: CSDBPSSPN020 / BCH, Cat No: BCHPSDBSPN20 / HPL, Cat No: MDBSP20 / HAGER, Cat No: VYA220Cor equivalent model in Havells / Indo Asian ) (NOTE : Enclosure & MCB shall be same manufacturer)
Taking down, refixing & connecting electric meters up to 40 amps 3 phase including tightening of all contact points complete all as specified and directed. (NOTE: New meters, if required shall be issued under Schedule 'B' as free for fixing. Old unserviceable meters shall be deposited in MES store & quoted rates shall be deemed to inclusive of the fact)
Hanging and fixing Ceiling fan of size1200/1400 mm sweep all connecting the electric supply with celing rose or connector to fan including of connection flexible wire length complete all as specified and directed by Engineer-In_Charge. (NOTE: Ceiling fan will be issued under Sch 'B' free for fixing)
Materials and Labour for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge earth plate at a depth not less than 1.5M below normal ground level connected to galvanized steel earth wire 4 mm dia (upto 7.5 metres) by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 45 cm x 45 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm centre to centre both ways, with one handle for lifting made out of 8 mm dia MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 40 mm bore galvanized steel tubing medium grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown in Figure 15A of IS 3043 :1987, complete all as specified and directed.
M/S SHRI P K ACHARJEE
MAZUMDER ENTERPRISE
SHEIKH ENTERPRISE
SOMANI BUILDERS
ARJUN DAS VALECHA
GHOSH ENTERPRISE
MS JYOTI INDUSTRIES
MS HORIZEN
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .