Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹29.0 LAccepted-AOC 275 2 AJIT NAGAR UPPER GADIGARH AIRPORT ROAD JAMMU 181101 | JAMMU | JAMMU | JAMMU AND KASHMIR | 181101 | L-1 | Accepted-AOC Lowest bidder | |
| 2 | L-2₹29.7 L+₹59,944 (2.06%)Rejected-AOC | L-2 | Rejected-AOC other than lowest bidder | |
| 3 | L-3₹33.8 L+₹4.7 L (16.3%)Rejected-AOC 5 A LANE 1 GREATER KAILASH JAMMU J K 180011 | JAMMU | JAMMU AND KASHMIR | 180011 | L-3 | Rejected-AOC other than lowest bidder | |
| 4 | L-4₹33.9 L+₹4.9 L (16.7%)Rejected-AOC | L-4 | Rejected-AOC other than lowest bidder | |
| 5 | L-5₹35.6 L+₹6.5 L (22.4%)Rejected-AOC | L-5 | Rejected-AOC other than lowest bidder |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
22 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sh Tanuj Bagla, EE
GE kaluchak Pin-900673 C/O 56 APO
SPL REPAIR TO FALSE CEILING AND EXTERNAL FLOORING TO BLDG NO P-261 MECH INF AND PROVN OF PAVER BLOCK HARDSTANDING NEAR BDE HQ BLDG NO T-5 AND PROV OF DEFICIENT CEILING AND EXHAUST FANS IN MD ACCN AT MIL STN RATNUCHAK UNDER GE KALUCHAK
2024_MES_639170_1
GE/KC/NIT-78/2023-24
Open Tender
Civil Works
Item Rate
120 days
Kaluchak
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE Kaluchak
₹94,000
Yes
27 May 2024
25 Jan 2024
24 Feb 2024
25 Jan 2024
22 Feb 2024
8 Feb 2024
25 Jan 2024 - 1 Feb 2024
Amount
Demolition of brick work or stone / boulder masonry including all quoins, arches, pillars, etc. built in cement mortar or cement lime mortar complete all as specified and directed.
Demolition of Concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed.
Taking down cement or cement lime plaster from brick or stone walls etc. including raking out joints, hacking for keys, scrubbing down with water etc. complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) including removing the rubbish off the premises complete all as specified and directed.
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft / loose soil complete all as specified and directed.
Removing surplus excavated material (SOIL) to distance not exc. 50 m and depositing where directed at a level not exc. 1.50 m above the starting point complete all as specified and directed.
M & L for hard core of gauge not exc. 63 mm, deposited, spread and leveled in layers not exc. 15 cm thick, watered and rammed to a true surface using broken stone or boulders complete all as specified and directed
M & L for providing plain cement concrete type B-1, 1:2:4, (using 20 mm graded stone aggregate), as in copings, bed block for embedding hold fasts, kneelers, apex stones, bed plates, water throughs and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed.
M & L for brick work with sub class ‘B’ old size bricks straight or curved on plan exc. 6.00 m mean radius built in cement mortar 1:6 complete all as specified and directed.
M & L for 100 mm thick cement concrete 1:4:8 type D-2, using 40 mm graded stone aggregate as in sub base floor complete all as specified and directed.
M & L for 50 mm thick cement concrete type B-0, 1:2:4 (using 12.50 mm graded stone aggregate) as in sub floor of floor finishes, finished even and rough complete all as specified and directed.
S & F for Vitrified light shade Ceramic tiles 9-10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. NOTE: - SCREED SHALL BE MEASURED AND PAID SEPARATELY.
S & F for Vitrified light shade Ceramic tiles 9-10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, as on vertical surface of wall such as skirting, dado, riser etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. NOTE: - RENDERING SHALL BE MEASURED AND PAID SEPARATELY.
M & L for precast designer coloured heavy duty full body paving tiles (factory made) of size 300mmx300mm x 20 mm, top layer glazed made in any type of cement and pigment, in required patterns as approved by GE in floor etc set & jointed in neat cement slury & pointed in white or coloured cement mixed with pigment to match over and including 15 mm thick screed layer in cement mortar 1:4, complete all as specified & directed.
Providing and laying 80 mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete. complete all as specified and directed.
M & L for 15 mm thick rendering on fair faces of brick work or concrete surfaces with cement mortar 1:6 finished even and smooth (without using extra cement)complete all as specified and directed.
M & L for 15 mm thick rendering on fair faces of brick work or concrete surfaces with cement mortar 1:4 finished even and smooth without using extra cement using integral water proofing compound as per manufacturer,s instructions , complete all as specified & directed. NOTE:- Integral water proofing compound shall be measured & paid seprately.
Supply only water proofing compound ( (Liquid) complete all as specified.
M & L for 15 mm thick screed bed or bedding layer in cement mortar 1:4 for laying floor finishes finished even and rough complete all as specified and directed.
M & L for 10 mm thick cement plaster on fair faces of brick work or concrete surfaces in cement mortar 1:4 on vertical surfaces of wall finished even and rough suitable for laying wall tiles complete all as specified and directed.
M & L for preparing newly plastered or previously untreated wall surfaces and applying two coat of oil bound distemper over a coat of chalk whiting complete all as specified and directed.
M & L for complete removal of old finishes from walls by scrapping, rubbing down, with sand paper to have even and smooth surfaces and applying two coats of oil bound distemper over a coat of 1 mm thick birla wall care putty complete all as specified and directed.
M & L for complete removal of old finishes from walls by scrapping, rubbing down, with sand paper to have even and smooth surfaces and and applying two coats of ‘Apex’ of Asian paint or ‘Weather coat’ of Berger Paints over one coat of primer complete all as specified and directed.
M&L for preparing newly plastered or previously untreated wall surfaces. and applying two coats of ‘Apex’ of Asian paint or ‘Weather coat’ of Berger Paints over one coat of primer complete all as specified and directed.
Suspended false ceiling system using 4mm thick high pressure steam cured fibre cement pre-primed textured varient E-board (classic), ISI marked, conforming to IS:14982-2000 over and including GI snap grid frame work for false ceiling, grid size 605 x 605 mm with GI angle of size 24x24mm, main runner ‘T’ of size 24x38mm, secondary runner ‘T’ of size 24x28mm with 6mm GI wire with butterfly clips as hangers for leveling, fastners, supports, plugs to walls/joists etc , hangers to be fixed with approved rawl plug, level adjusters and screwsa etc, last hanger at the end of each runner shall not be greater than 450mm from adjacent wall all as per manufacturer’s Instructions including making holes, cutting chasis and making good existing walls in cement mortar 1:3 or PCC 1:2:4 type B1, complete all as specified and directed. Note : All steel members shall be hot dipped galvanised with zinc coating not less than 120 gm/sqm.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.complete all as specified and directed.
Taking down carefully existing sub main wiring complete of any size and capacity complete all as specified and directed.
Taking down carefully unserviceable main switches, DBs including MCBs etc. complete of any size and capacity complete all as specified and directed.
M&L for point wiring one light / fan/Exhaust fan point controlled by one way switch(concealed type) complete with multi stranded copper conductor flame retardant low smoke (FRLS) 1.5 Sqmm size PVC insulated unsheathed cable 1100 volts grade drawn through with and incl medium grade duty concealed PVC conduit ISI marked not less than 20mm dia including conduit fittings and accessories such as socket,elbow,junction box, bell mouth,bend, reducer etc complete incl cutting chases in existing walls of any description built in cement mortar and making good the disturbed surfaces in cement mortar (1:4) and finishing the surfaces to match with existing surfaces and finish with using sunken type pressed steel terminal boxes of required sizes of not less than 1.6 mm thick factory made and factory painted with top cover of 3 mm thick plastic laminated sheet fixed with brass screws washers with all accessories including single core multi stranded copper conductor 1.5 Sqmm size PVC insulated unsheathed cable green in colour as earth wire to common earth and connected to earth dolly drawn in same conduit complete all as specified . NOTE :-Wire/Cable colour coding Shall be maintained properly as per IE rule.
All as per item No 31 but for one 3/5 pin socket outlet 5 Amps on the same board with other switches.
All as per item No 31 above here in before but with 4.0 Sqmm (nominal area) cable PVC insulated but unsheathed for the 15 Amp 3/5 pin socket power point including 2.5 Sqmm copper conductor green in colour for earth continuity on independent board complete all as specified and directed.
S&F switch piano flush type polycarbonate single pole one way 5 Amps complete all as specified and directed.
S&F socket outlet polycarbonate 2 in 1, 3 pin 5 Amps flush type complete all as specified and directed.
S&F Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal complete all as specified and directed.
S&F Ceiling rose three teminal /PVC/ polycarbonate, insulated body complete all as specified and directed.
S&F of fully diffused recessed mounted luminaire 2'X2' LED 36 Watt suitable for POP/Gypsum false ceiling complete with all accessories pre-wired and making connection with three core PVC insulated overall sheathed flexiable copper cable of size 0.75sqmm from ceiling rose to light fitting, complete all as specified & directed.
Supply and fixing factory made epoxy powder coated distribution board, SPN, 8 ways with metal door (IP-43 protection), confirming to IS : 8623 fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall, suitable for universal mounting including 200 Amp copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with knockouts, suitable for one SPN/DP MCB as incomer and SP MCB outgoing, complete all as specified & directed .
Supply and fixing factory made epoxy powder coated distribution board, SPN, 4 ways with metal door (IP-43 protection), confirming to IS : 8623 fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall, suitable for universal mounting including 200 Amp copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with knockouts, suitable for one SPN/DP MCB as incomer and SP MCB outgoing, complete all as specified & directed .
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified & directed.
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of SPN and current carrying capacity 40 to 63 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified & directed.
M&L for sub main wiring with 2 Single core PVC insulated unsheathed FRLScable 1100 Volts grade heavy duty copper conductor multistranded of size 6 Sqmm (nominal area) drawing in and including 25 mm dia or higher medium duty PVC concealed conduit and conduit accessories and fittings. including one single core green colour PVC Insulated unsheathed FRLS cable copper conductor multistranded of size 4.0 Sq mm as earth wire upto common earth and connected to earth dolly complete all as specified & directed.
Supply, hanging and testing of BEE 5 Star rated energy efficient brushless direct current motor (BLDC) ceiling fan, 1200mm (48 inch) sweep, having 3 blades made of aluminium alloy, down rod, canopies, shackles, 240 volt, single phase suitable for input voltage range 140-285 volts, AC, 50Hz, power factor not less than 0.99, service value minimum 8 cubic metre / min/ watt or higher, air delivery minimum 230 cu metre/ min or more, power consumption maximum 28 watt or lower, top speed minimum 340 RPM or higher, THD not more than 10% including 5 step electronic regulator marked on rotating knob, two module, 100W, 240 volts with 3 years on site warranty for speed control, copper winding, complete as per IS:374-1979 or latest IE rule & site requirement, colour white complete and taking down old unserviceable fan of any type/ size from existing location and depositing in MES storeyard, complete all as specified & directed.
Supply & fixing metallic exhaust fan, 300mm (12") sweep, single phase, 230 volts, 50 Hz AC, 1400 RPM, energy saving, heavy duty totally enclosed, heavy duty motor with die-cast aluminiun rotor mounted on two ball bearings, complete with louvers and shutters, connecting electrically using 3 core 0.75 Sq mm PVC insulated flexible copper conductor cable including cutting holes in existing brick walls for making opening for fixing of exhaust fan of 300mm sweep including grounting bolts/nuts ,MS Jali made of 3 mm dia MS wire 50 mm apreature fixed with and including proper wooden frame at outer surface of wall and making good disturbed surface of walls using cement sand mortar 1:4, complete all as specified & directed.
M&L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel and connecting to main switch or switch board complete and incl PCC masonry pit of 300x300x300mm interior dimensions in PCC 1:2:4 type B-1 RCC cover with GI frame, charcoal and common salt 15cm in layers all round the earth plate, 15mm dia GI watering pipe, a funnel with wire mesh should be provided on top of watering pipe complete all as specified as per electric plate No 3 of SSR 2009 including testing after completion complete all as specified and directed.
M/S SUDAGAR MAL
NARESH KUMAR AND COMPANY
VEE ESS ENGINEERS
JK BUILDERS AND DEVELOPERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .