Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
Refer Docs
EMD Value
₹24,000
Closing Date
3 Jul 2020, 11:30 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE EnM WnS S II
Apollo Booster Pumping Station Mathura Road New Delhi
Press NIT No.07 EE EnM WnS S II 2020 -21 item No 01
2020_DJB_191925_1
Press NIT No.07 EE EnM WnS S II 2020-21
Open Tender
Miscellaneous Works
Works
60 days
Work
Please refer tender documents
3 documents required · 3 mandatory
₹500
ON LINE
₹24,000
Yes
6 Jul 2020
22 Jun 2020
3 Jul 2020
22 Jun 2020
3 Jul 2020
22 Jun 2020
120 days
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C (1.10.3)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required a) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire(1.14.2)
b) 4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire (1.14.7)
c) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire(1.14.3)
d) 4 X 4 sq. mm + 2 X 4 sq. mm earth wire (1.14.8)
d) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire(1.14.4)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. (1.31)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required 1.32
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) a) 8 way (4 + 24), Double door (2.5.2)
b) 12 way (4 + 36), Double door (2.5.3)
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Single pole 2.10.1)
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 100 A (2.13.3)
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. (5.2)
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. (5.7)vvvv
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. (1.25)
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. (1.33)
Supplying and fixing PVC batten/ angle holder including connections etc. as required. (1.58)
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. (1.38)
Supply of 18/20 watt LED regal batten light fitting with tube. (Make: - Bajaj/ Phillips/ Crompton/ Havells/ Panosonic /DJB approved).
Supply of 70 watt LED flood light fitting (Make :- Bajaj /Crompton /Havells /DJB approved)
Supply of 1200mm Sweep Ceiling fan Make :- ( Bajaj / Khaitan / Crompton/ Usha /DJB approved ).
Supply of 300mm Exhaust fan heavy duty Make :- ( Bajaj / Khaitan / Crompton/ Usha /DJB approved).
Supply of 600 mm Aircirculator heavy duty ( Make: - Bajaj / Khaitan / Crompton/ Usha / Almonard /DJB approved).
Supply of 2 x 16 sq mm Alumunium conductor armourd cable (Make: - Polycab/ Havells/ Kalinga/ Grandlay /DJB approved)
Suplly of 200 Amp FP Changover switch (Make: - L&T/ ABB/ Havells /DJB approved)
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. (1.41)
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. (1.44)
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep (1.50.1)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 35 sq mm (7.1.1)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle) (7.7.1)
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. (5.18)
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 amps “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.(2.18)
Fabrication, Supplying and Installation of cubical compartmentalised panel wall mounted/floor mounted with necessary support, front openable of suitable size, upto minimum 300 mm deep, made out of M.S. Sheet of 2mm Thick (14 SWG) duly having 4 strip Al. busbar of 400Amp (50mm x 6mm) capacity with door, locking arrangement, and having the provision of following accessories mounted inside the cubical panel i/c connection, inter connection with aluminum thimbles, earthing with two nos. earth studs duly powder coated/painted with 07 tank process complete as reqd i/c control wiring. a) 200 Amp FP Changeover – 1 No. b) 400 Amp FP 50 KA MCCB – 1 No. c) 125 Amp 25 KA TP MCCB – 3 No. d) VAF Meter – 1 No. e) LED Indicator lamp – 1 Set. (Accessoris Make : - L&T/ ABB/ Havells /DJB approved)
Dismantling of old defective / burnt batten wiring. Unusable MS box, changeover switch. Including Fixing of flood light with providing SMC Pole Box with MCB, aircirculator & changeover switch etc., PVC insulated copper wire installation with the help of accessories and testing commissioning completed etc. reqd. site.
GOGIA BROTHERS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .