| 1 | L1₹4.7 LAccepted-AOC 2 2 BLOCK B MAYUR RESIDENCY MISRAPUR KURSI ROAD LUCKNOW 226026 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226026 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹5.4 L+₹60,630 (12.7%)Rejected-Finance 145 SAINIK NAGAR RAIBARELLI ROAD TELIBAGH LUCKNOW | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹5.7 L+₹94,155 (19.7%)Rejected-Finance | L3 | Rejected-Finance Being other than L1 | |
| 4 | L4₹6.0 L+₹1.2 L (25.7%)Rejected-Finance | L4 | Rejected-Finance Being other than L1 |
Tender Value
₹7 L
EMD Value
₹14,000
Closing Date
6 Jul 2023, 6:00 pmClosed
AGE (I) AF Memaura
AGE (I) AF Memaura
REPAIR MAINT AND REPLACEMENT OF INTERNAL ELECTRICAL WIRING FITTING AND FIXTURES IN SMQ AND OMQ AT AF STN MEMAURA
2023_MES_602218_1
8310/E8
Open Tender
Civil Works
Works
183 days
AGE (I) AF Memaura
As per NIT
8 documents required · 8 mandatory
₹500
AGE (I) AF Memaura
₹14,000
Yes
8 Aug 2023
9 Jun 2023
8 Jul 2023
9 Jun 2023
6 Jul 2023
22 Jun 2023
Amount
Taking down carefully copper/Aluminium point wiring (light/fan/socket power) complete of any size, type and including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good to the disturbed surfaces of walls, floors, etc to match with the existing surfaces complete all as directed.
Material and labour for point wiring concealed type with 1.5sq mm PVC insulated unsheathed single core multistranded FRLSH copper conductor cable 1100 volts grade incl. 1.5 Sq mm PVC insulated unsheathed copper conductor cable as earth continuity conductor drawn through and incl. medium grade PVC rigid conduit not less than 20 mm dia with its accessories, galvanized pressed steel terminal boxes of thickness 1.0 mm covered including 3mm thick laminated sheet cover for fixing switches/ socket/regulators etc for the following: - Note:- (i) On RCC ceiling/column, false ceilling, AC/Metallic Sheet ceilling wiring done on surface with conduit/PVC Casing caping and its accessories. (ii) The quoted rete is deemed to be included for the chases cutting. (iii) Cutting chases for concealed shall be made good using CM 1:4 and surface finished to match the existing surface & colour.
One light/fan/exhaust fan/ Bldg security light point controlled by one switch.
One socket outlet 6 amp controlled by one switch on the same board.
One socket outlet 6 amp controlled by one switch on indepdendent board.
One bell point controlled by one bell push.
One light point controlled by two, two way switches.
All as per item No.2 here-in-before but by using 2.5 Sqmm FRLS copper conductor cable with continuous earth wire of 2.5 Sqmm FR copper conductor for one 3 pin 15 Amp socket outlet point controlled by one switch.
Material and labour for point wiring in PVC casing and caping type with 1.5sq mm PVC insulated unsheathed single core multistranded FRLSH copper conductor cable 1100 volts grade incl. 1.5 Sq mm PVC insulated unsheathed copper conductor cable as earth continuity conductor drawn through and incl. ISI mark suitable size PVC casing and caping with its accessories, PVC terminal boxes of thickness 1.0 mm covered including 1mm or more thick PVC cover for fixing switches/ socket/regulators etc for the following: -
One light/fan point controlled by one switch.
One socket outlet 6 amp controlled by one switch on the same board.
One socket outlet 6 amp controlled by one switch on indepdendent board.
One bell point controlled by one bell push.
All as per item No. 09 here-in-before but by using 2.5 Sqmm FRLS copper conductor cable with continuous earth wire of 2.5 Sqmm FR copper conductor for one 3 pin 15 Amp socket outlet point controlled by one switch.
S&F in replacement of 5 Amp switch socket combination flush type 240 Volt complete.
S&F in replacement of 15 Amp switch socket combination flush type 240 Volt complete.
S&F bell push, flush type, 6 amp 240 volts complete.
S&F switch flush type, 6 amp, single pole, two way complete.
S&F ceiling rose three terminals complete.
S&F door bell, ding dong/ multi music, AC, 240 volts, single pole complete.
S&F angle holder, insulated polycabonate body with back plate complete.
S&F in renewal LED bulk head luminaire, internally prewired with and including premium quality diffuser for glare free light, 10 watt, Ingress protection IP 65, colour temp - 6500K, surge protection 2.5 KV, 50000 burning hrs (min) as per L70 criteria and connecting the same in electric source with and using PVC sheathed and insulated 3 core copper conductor cable of size 0.50 Sqmm and fixing arrangement for fixing the light fitting complete all as specified and directed.
S&F square slim surface mounted LED down lighter of capacity 15 watts, 240 volts, white powder coated pressure die cast aluminium housing and bottom frame with high transmitive LGP technology, high efficiency non yellowing PMMA diffuser, complete with LEDs driver and accessories pre-wired upto terminal block lumens wattage not less than 15 watts, luminaire lumen output >1500 Lm, ingress protection IP-20, ambient temperature 0-450 C driver efficiency more than 85% power factor above 0.95, Surge protection 3 KV multi stage isolated constant current and variable working votlage 15-0270 Volts complete all as specified and directed.
Supply and fixing 10 SQMM 2 Core PVC insulated PVC sheathed Aluminium, flame resistant flat cable all as specified and directed.
Supply and fix in replacement of decorative wall mounting type LED light fitting, 1 x 9 Watt, 230 Volt made up of Polycarbonate including shade, lamp holder, 9 Watts LED lamp B22 CDL etc and all accessories pre-wired including connecting up complete all as specified and directed.
Material and labour for sub main wiring with 10 Sq mm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, ISI marked, unsheathed, FRLSH copper conductor cable with and including continuous earth wire of size 10 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade, ISI marked complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing including taking out the unserviceable sub main wiring complete all as specified & directed.
All as Item NO 26 above with 06 Sqmm nominal cross section area
All as Item NO 26 above with 04 Sqmm nominal cross section area
Supplying and fixing in replacement SPN Distribution Board 4 Way,metal double door, neutral busbar, earth bar, din bar, blanking plates in unused spaces etc as required complete all as specified and directed.
All as Item NO 29 above but SPN DB, 240 volts, 8 ways
All as Item NO 29 above but SPN DB, 240 volts, 12 ways
All as Item NO 29 above but TPN DB, 415 volts, 04 ways
Supplying and fixing in replacement VTPN distribution board suitable for MCCB incomer upto 125 amp, 4 way, 415 volts, degree of protection IP 43 with metal double door, having 200 amp insulated bus bar, blanking plates in unused spaces etc as required complete all as specified and directed.
S&F in replacement metal clad plug & socket DB with plug top including one MCB single pole 32 Amps 240 volts 50 HZ complete all as specified & directed.
Supplying and fixing MCBs Single pole 6 to 32 Amp of breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size complete all as specified and directed.
All as Item NO 35 above but SPN 06 to 32 Amp
All as Item NO 35 above but SPN 40 to 63 Amp
All as Item NO 35 above but TPN 25 to 63 Amp
Note for MCBs & MCB DBs:- MCBs & MCB DBs shall be of the same make. MCB DBs shall be fixed on wall in flush pattern by cutting the wall and making good disturbed surfaces.
Supply and fix in replacement of MCCB, 100 Amp, 04 Pole, AC, 415 volt of 16 KA breaking capacity and making connections by using suitable copper lugs complete all as specified & directed.
Supplying and fixing MCCB four pole, 125 amps, 16 KA thermally adjustable between 70 to 100% including 4 spreader link set of same make as that of MCCB for connection, required lugs etc complete.
S & F Wall/surface mounted type LED light fitting batten type complete with LED 1x 20 watt (4 feet long), extruded aluminium body with heat sink provided for efficient heat dissipation and integrate electronic drive complete with all accessories internally pre-wired and including connecting up with 3 core twisted flexible copper conductor cable complete all as specified and as directed.
S & F Wall / surface mounted type LED light fitting batten type complete with LED lamp 10- watt (2 feet long), poly carbonate body and integrate electronic drive complete with all accessories internally pre-wired and including connecting up with twine core twisted flexible copper conductor cable complete all as specified and as directed.
Material and labour for earthing complete with galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanised earth lead wire 4 mm dia by means of steel bolts, nuts, check nuts and washers all as shown in electrical plate no 5 of MES Schedule Part-I connected to earthing point and testing on completion with and including 15 mm bore medium grade G.I. protection pipe (upto 7.5 metre beyond outer edge of earth pit) PCC pit in mix 1:3:6 type C1 with RCC 1:2:4 type B-1 40 mm thick cover reinforced with 6 mm dia M.S bars 3 nos both ways with lifting hook made out of 6 mm dia bar, watering arrangement with funnel and wire mesh and 20 mm bore light grade G.I. watering pipe, common salt and charcoal filling, necessary excavation and earth work complete after dismantling unserviceable earthing (above GL only) complete all as specified and directed.
Supply and lay, jointing & testing of cable 10 Sqmm 2 Core XLPE armoured LT 1100 volt grade heavy duty with Stranded aluminium conductor passing through ducts/pipes and run on poles/walls including fixing with proper size of alluminium lugs/saddles and taking down old cable complete all as specified and directed.
All as Item NO 45 above with 06 Sqmm 2 Core
M/S KAUSHIK CONSTRUCTION
VIDYA TRADERS
m/s pal associates
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .