| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.2 LAccepted-AOC | L1 | Accepted-AOC 1ST LOWEST | |
| 2 | L2₹37.4 L+₹22,756.70 (0.61%)Rejected-Finance AKULA STREET BHAPUR BAZAR BERHAMPUR DISTT GANJAM ODISHA 760001 | GANJAM | ODISHA | 760001 | L2 | Rejected-Finance 2ND LOWEST | |
| 3 | L3₹38.3 L+₹1.1 L (2.87%)Rejected-Finance | L3 | Rejected-Finance 3RD LOWEST | |
| 4 | L4₹38.8 L+₹1.6 L (4.31%)Rejected-Finance | L4 | Rejected-Finance 4TH LOWEST | |
| 5 | L5₹39.5 L+₹2.3 L (6.16%)Rejected-Finance | L5 | Rejected-Finance 5TH LOWEST |
Tender Value
₹36 L
EMD Value
₹72,000
Closing Date
2 Mar 2022, 6:00 pmClosed
GARRISON ENGINEER I GOS
GARRISON ENGINEER I GOPALPUR MILITARY STATION PO GOLABANDHA DIST GANJAM ODISHA 761052
PROVN OF GUARD ROOM WITH TOILET FACILITY AT NEW DOI INCLUDING SPECIAL REPAIR TO ROAD FROM SHOPPING COMPLEX TO IG CIRCLE AND FROM RXN CELL TO TCP 05 AND PATCH NEAR GOLF COURSE AT GMS UNDER GE I GOS
2022_MES_506835_1
8000/98/21-22/0997/E8
Open Tender
Civil Works
Item Rate
180 days
GOPALPUR-ON-SEA
PLEASE REFER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER I GOS
₹72,000
Yes
29 Mar 2022
9 Feb 2022
4 Mar 2022
9 Feb 2022
2 Mar 2022
24 Feb 2022
Amount
Surface excavation n.exc 30 cm deep and getting out in soft/lose soil Complete all as specified & directed.
Excavation in trenches not exceeding 1.5m wide and not exc1.5m in depth; for foundation, etc. or for shafts, wells, cess pits, manholes, pier holes, etc. not exceeding 10 Sqm on plan and not exceeding 1.5 m in depth and getting out in soft/losse soil complete all as specified and directed.
M & L Plain cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
M&L reinforced cement concrete (nominal mix) 1:2:4 type B1 using 20 mm graded stone aggregate as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed
Formwork to flat sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed.
M&L reinforced cement concrete (nominal mix) 1:2:4 type B1 using 20 mm graded stone aggregate as inColumns, pillars, piers, posts and struts complete all as specified and directed
Formwork to Square,rectangular or polygonal rough surface of concrete of sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed.
M&L reinforced cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) Complete all as specified & directed.
S&F rolled mild steel section as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connected plates of grade Fe 410-W (Gde E-250) quality A complete all as specified and directed
M&L for preparation of new or previously untreated surfaces of steel of any description, over 10cm in width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
M&L reinforced cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed
Returning, filling including spreading, levelling, watering and well ramming in layers not exc 25 cm in getting out soft/loose soil Complete all as specified & directed.
Removing surplus excavated earth (soil) to a distance n. exc 50 m & depositing where directed at a level n. exc 1.5 m above the starting point complete all as specified and directed.
S&F Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
S&F Mild steel TMT bars 8mm dia and over, cut to length, spacers and binders and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M & L brick work with sub class B bricks straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and directed.
M & L 40mm thick PCC 1:2:4 damp proof course to horizontal or vertical surfaces including necessary formwork complete all as specified and directed.
M&L for 15 mm thick rendering in CM 1:4 on brick or concrete surface, finishing even and smooth without using extra cement but using water proofing compound complete all as specified and directed.
M&L for 10 mm thick rendering in CM 1:6 on brick or concrete surface, finishing even and smooth without using extra cement complete all as specified and directed.
M&L moorum / Red bajri filling in floors or pavings, laid in layers n.exc15 cm thick spread levelled and rammed incl watering etc complete all as specified and directed.
M&L Hard core of gauge n.exc 63 mm, deposited, spread, levelled in layers not exc 15 cm thick, watered and well rammed to a true surface Complete all as specified & directed.
M&L 100 mm thick PCC 1:4:8, type D2 using 40 mm graded stone aggregate as in sub base, sub floors, including use of formwork / screed strips to divided the area in panels Complete all as specified & directed.
M&L 25 mm thick PCC 1:2:4 type B0 using 12.5 mm graded stone aggregate as in floors finished even surface Complete all as specified & directed.
M&L 75 mm thick PCC 1:3:6, type C-1 using 20 mm graded stone aggregate as in plinth protection, surfaces finished even and smooth with out using extra cement complete all as specified and directed.
S&F glazed ceramic colored tiles (Premium quality) 200x300x6 to 7mm thick coloured on vertical surface such as dado/skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match tile including rendering 15 mm thick on brick or stone masonry surfaces finished fair and even to recieve tile in CM 1 : 4 complete all as specified and directed.
M&L for Non Skid ceramic tiles 7 to 8 mm thick(square/ rectagular) area of each tile exceeding 0.11 sq m but not exceeding 0.18 sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match , including 20mm thick screed bed in CM 1 :6 complete all as specified and directed.
M&L for perparation of new plastered surface of wall and applying two coats of cement based paint over a coat of white wash Complete all as specified & directed.
M&L preparation of newly plastered surface of walls and applying two coats colour wash over one coat of white wash complete all as specified and directed.
Supply only water proofing compound of approved make.
S&F Water closet vitreous china squatting pan, orissa pattern 580x440mm white with integral foot rests including flushing cistern and flush pipe including provision of lime concrete bedding complete all as specified and directed.
M&L for vitreous china wash basin, white,flat back, size 550 x 400 mm with brackets, including supply & fixing pillar cock 15 mm bore CP fancy type, PVC connection of 450 mm long, PVC (HDPE) 32 mm bore waste pipe, brass couplings 32 mm CP etc complete all as sapecified and directed.
M&L brick work with subclass 'B' bricks straight or curved on plan to any radius half brick thick wall built in CM 1:4
S&F 20mm dia GI tubing medium grade galvanised with all fittings and fixed complete to walls and ceilings or laid in floors Complete all as specified & directed.
S&F 15mm dia GI tubing medium grade galvanised with all fittings and fixed complete to walls and ceilings or laid in floors Complete all as specified & directed.
S&F 15 mm fancy type pillar taps chromium plated cast copper alloy with capstan heads screwed down high pressure with or without lettered ‘Hot’ or ‘cold’ with long screwed shanks and fly nuts complete all as specified and directed.
S&F 15 mm fancy type stop valve cast copper alloy chromium plated screwed down high pressure with crutch or butter fly handle screwed both ends for iron or union and fixed to 15 mm GI tube complete all as specified and directed.
S&F 15mm bore bib tap cast copper alloy chromium plated with crutch or butterfly handle fixed to 15 mm dia GI tube complete all as specified and directed.
S&F 500 ltr capacity Rotational moulded polyethylene water storage tanks (cylin-drical vertical with closed top) hoisted and fixed in position complete all as specified and directed in SSR Part I
S&F 25mm dia ball Brass valves, high pressure, with polythene float and fly nut complete, screwed for iron pipes or brass ferrule and fixed as in PVC Service tanks complete all as specified and directed.
S&F 20mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed to 20mm dia GI tube Complete all as specified & directed.
All as per Item No. 42 above but 25 mm dia.
S&F PVC(SWR)75mm borepipes single socketed in any length with rubber ring joints fixed to walls/floor Complete all as specified & directed.
All as per item No 44 above but 110mm bore
S&F 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement Complete all as specified & directed.
PVC (SWR)bend 110mm bore
PVC (SWR)bend 75mm bore
PVC(SWR) bend 110mm bore with access door
All as per item No 48 above but 75mm bore
S&F PVC (SWR) vent cowl, 100mm dia
S&F PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement Complete all as specified & directed.
S&F PTMT waste coupling of 32mm dia for wash basin/urinal complete all as specified and directed.
S&F PVC LDPE waste pipe of pressure rating 6kg/cm2 of 32mm dia pipes Complete all as specified & directed.
S&F PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and directed.
M&L PCC 1:3:6 type C2 concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested for 200mm dia pipe complete all as specified and directed.
M&L 200mm dia salt galzed stoneware drain pipes laid in trenches and jointed complete all as specified and directed.
M&L cutting in to existing manholes for connecting new drains, making good to pipe & rendering cutting out existing benching for and forming branch channel in cement concrete1:2:4 type B-1 smooth finished and reforming benching as required for 200 mm bore drain pipe Complete all as specified & directed.
S&F factory made UPVC white colour fixed window/ventilator made of extruded profile with wall thickness of 2.3mm (+-2mm). Window profile with hollow section with multi chamber. Frame (60mm X58mm). T profile (one vertical length in between two shutters) (60mm X 74mm). Glazed bead (35mm X 20mm) will be mitered cut and fusion selded at all corners including drilling of holes for fixing hardware and drainage of water etc, making arrangement for fixing of hardware, EPDM gasket 1.2 +-0.2mm thick glavanised steel frame (28mm X 21.5mm), T profile (27mm X 17mm) to be inserted in repair profile. Frame will be fixed to the wall with 8mm X 100mm long fasteners. 5.5 mm thick glazing with ordinary quality glass and gauge as required at site. (Note : The unit rate includes the cost of glass, gauge and all other connected accessories) area n.exc 1.00sqm each.
S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, suppling & fixing in opening as per specification & drawing.
S &F Factroy made solid panel PVC door shutter 30 mm thick (Style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with het moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuch inside with solvent cement for stiles and plan colour PVC sheets for top rail, lock rail & bottom rail on either side & as fap insert for top rial & bottom rail, Penelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement suppling & fixing in the frame at site as per specification & drawing.
M&L butt hinges extruded aluminium alloy with galvanised mild steel hinge pin anodised type B-21 for 100 mm long complete all as specified and directed.
S&F extruded aluminium alloy handles fabricated type anodised of 150 mm size complete all as specified and directed.
S&F aluminium, anodised, barrel tower bolts of extruded section 150 mm long complete all as specified and directed.
Supply and fixing LED bldg security light fitting 25 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. Make Havells, Cat No enduraPearlsl25Wled757sasYtoPCmP or equivalent of higher cost.
M&L point wiring complete with PVC insulated and unsheathed, flame retardant low smoke 1100 volt grade electric cable of 1.5 Sqmm (nominal area) with multi stranded copper conductor single core in and including rigid PVC concealed conduit not less than 19mm dia, and wall thickness 2mm, with suitable GI flush metal boxes (not less than 1.00mm thick) of suitable sizes including earth dolly with 3mm thick plastic laminated sheet top cover of approved colours including 1.50 Sqmm PVC insulated & unsheathed copper cable as continuous earth wire with all accessories including lugs required, complete all as specified and directed for the following :- (a) One light/fan point controlled by one way switch 5 Amps
(b) One 5 pin socket outlet, 5 Amps, Independent board.
S&F LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S&F Switch piano flush button single pole one way 6 Amps, complete all as specified and directed.
M&L for Switch socket combination 2 in 1, 5 A flush type complete all as specified and directed.
S&F Sheet metal enclosure factory made single door for mounting MCBs with 200A rated bus bar capacity SPN 4 way AC 230 volts with IP-43 protection, complete all as specified and directed.
S&F Ceiling rose 3 terminals of PVC/ polycarbonate, as per relevant IS code, ISI marked isolated body complete all as specified and directed.
M&L earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, burried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less'than 1.5 meters below normal ground level, connected to galvanised iron earth lead wire of 4 mm dia GI pipe mediam grade 15 mm dia upto 7.5 mtr including provn of conrete pit in PCC (1:2:4) type B-1 using 20 mm graded stone aggregates with 40 mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 kg/sqm) and frame of angle iron 25x25x3 mm with lugs 02 Nos and with 6.0 mm dia MS bar handle made to shape, GI light grade 20 mm bore pipe for earth plate, common sald and charcoal filing, test point made out of Bronze/ Gun metal with fixing arrangement, funnel, wire mess and excavation/ earthwork in hard/ dense soil, to a distance not exceeding 50 mtr all as per electrical plate No 3 of SSR 2010 Part I and connecting to earth test point all as specified or indicated incl testing on completion.
S&F 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning
S&F amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of 40 to 63 Amp current carrying capacity in the MCB DB complete with connection testing and commissioning.
M&L for street light fitting bracket made out of 32mm bore GI pipe, light grade, tubing bend to shape, 1.2 metre long, fixed to pole/wall, painting with two coats of aluminium paint over a coat of red oxide primer complete, all as specified and directed.
S&F exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300mm complete all as specified and directed
Supply dry sand for cushioning to underground cables 8cm thick before laying cable and 15cm thick after lying and streching the cable, complete all as specified and directed. Note :- For payment purpose punned thickness shall be measured.
S&F Sub class ‘B brick, old size, as cable protection cover, laid dry, flat, transversally along the length of cable, on sand cushioning, with width equal to the length of the brick, complete all as specified and directed
Supply, laying and testing LT cable XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade cross section area 10 sqmm 2 core complete laid in trenchers, duct, passing through pipe, fixed to poles complete all as specified and directed
Supply and laying for 3- layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches of size 25 mm complete all as specified and directed.
Supply and fixing PP-R Gate valves (brass insert) of size 25 mm dia complete as per requirement of the site
Making connection of PP-R distribution branch with PP-R main of following sizes by providing and fixing tee including cutting and making fusion joint etc Complete all as specified & directed.
M&L for Repair to pot holes any depth, not exc 1 sqm each including sweeping free from dust and mud or water, scoring sunken surfaces in roads, paths, etc cutting around edges to at least 25mm in depth, and making good by applying tack coat @ 5 Kgs per 10 Sqm and laying premixed bituminious macadam well rammed and sealed with paving bitumen 60/70 or VG-30 grade@ 9.8 Kgs per 10 Sqm, blinded with 0.09 Cum of stone chipping of size 6.3mm and again well rolled with 8 to 10 tonne power roller (Iincluding supply of pre-mixed macadam, binder and chipping) depth of pot holes exc 30mm complete all as specified and directed.
M&L for Preparing existing black top surface or bituminous macadam surfaces by brushing with brushes for removing caked mud etc sweeping with brooms and finally fanning the cleaned surfaces with gunny bags to remove all loose dirt etc on back top/concrete surfaces than applying evenly priming tack coat with paving bitumen 60/70 or VG-30 penetration over the prepared surface by mechanical sprayer @ 5 Kgs/10 Sqm of surface area complete all as specified and directed.
M&L for applying bituminous premixed semi dense asphaltic concrete 30mm thick (consolidated thickness) with 5.5% binder content of paving bitumen 60/70 or VG-30 grade by weight of total mix including cement filler, on surfaces rolled & compacted with using 8 to 10 tonne capacity power roller to achieve the required compactness, camber and gradient mixed in hot mix plant using design mix and laid by mechanical paver finished complete all as specified and directed.
M&L for premixed bituminous macadam laid, rolled and compacted to required gradient and camber n.exc 75mm thickness (consolidated thickness) with 4% binder content of VG -30 by weight of total mix, mixed in hot mix plant and laid by mechnical paver finished complete all as specified and directed.
M&L for preparation of existing bituminous surfaces, removing, dust, dirt grease and other foreign matters etc to receive the marking and M&L for thermo plastic (Reflective) line marking having 1.0 mm thickness (average) of uniform surface finish conforming to BS 3262 (Part 1) 1989 read in conjunction with the MOST specification 803 clause 4.2.2 on bituminous surfaces in white/yelow clour and super imposed with glass beads confirming to BS 6088 read in conjuction with and MOST specification 803 clause 4.3.3 complete all as specified and directed. Note - MOST specification 803 shall be followed strictly for execution of work & suitable machine shall be used for the marking as approved by the GE. Shape & size/ patterns of marking shall be as approved by the GE.
S&F in repair cat eyes/road studs for roadways sign permanent surface mounted type having tough poly carbonate micro replicated corner cube reflector lenses with a protective abrssion resistant ceramor coating having body of weather proof and impact resistant thermoplastic complete as per manufacturer,s instruction complete all as specified and directed. (Colour :- Yellow/Red/Amber) Make: Series 290 of 3M or Road Star or Equivalent of higher cost
S&F in repair solar cat eyes/road studs size (mm) 125L x 125B x 25H including stem height 53mm approx housing dia cast aluminium (grade LM-6) fully water proof and weather proof and weatherproof coating visible distance upto 400mtr LED-6 super bright amber led (3 Nos each side) yellow charged, flush frequency 1.2 Hz-1.8Hz including solar panel 3.5V/110MA & battery one PC sub ‘C’ type Ni-Cd rechargeable battery 1.2V/2.5AH temp range 20C to 70C fixed on road for roadway sign complete as per manufacturer’s instruction complete all as specified and directed. Make: 3M/Avery Dennision/Dark Eye/Green/Greenlite/Road Star Cat Part No. GSR-909 or Equivalent of higher cost.
S&F in repair ABS Body, 100 cm outdoor convex mirror good quality as approved by GE fixed in road/ground portion complete including hanging/fixing arrangement with adequate mounting arrangement at suitable height, having unbreakable Polycarbonate Convex Lens with hoods as the traffic safety mirror for eliminating blind spots & increase visibility at a broader angle, including excavation for post holes, PCC Type C-2 1:3:6 (using 40 mm graded stone aggregate) in post hole & removal of surplus excavated material to a distance not exceeding 50 metre & depositing where directed at a level not exceeding 1.5 metre above the starting point. Complete all as specified & directed. Make: Frontier 100 cm outdoor Convex Mirror, FMCO-100, Road Star, Real reflectors, Alexix, ACE polymers (India) or Equivalent of higher cost.
Likitha Enterprises
MM ENGINEERING SYSTEMS
M/s J. P. ASSOCIATES
M/s MAA BHAIRABI ENTERPRISES
HARAGOURI SUPPLIERS
DHABALESWAR ENGINEERING WORKS
M/S JAGANNATH SASMAL
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .