Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.8 LAccepted-AOC SAMBA LINE JUNGLIGHAT POST SRI VIJAYA PURAM 744103 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L1 | Accepted-AOC L1 | |
| 2 | L2₹49.9 L+₹1.2 L (2.40%)Rejected-Finance NEAR SATSANG GARACHARMA BASTI GARACHARMA PORT BLAIR 744 105 | PORT BLAIR | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744105 | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹50.3 L+₹1.5 L (3.15%)Rejected-Finance 290 NEW PLOT JAWAHAR NAGAR JAMMU JAMMU JAMMU KASHMIR 180005 | JAMMU | JAMMU AND KASHMIR | 180005 | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹52.4 L+₹3.7 L (7.55%)Rejected-Finance | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹54.5 L+₹5.7 L (11.7%)Rejected-Finance | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
26 Jan 2024, 6:00 pmClosed
GE Minniebay
GE Minniebay Juglighat Post Minniebay Port Blair 744103
PROVN OF ALL WEATHER TRAINING SHED AT MARCOS TEYLERABAD AND PROVN OF WALL FROM GUARD ROOM TO ANTENNA PLATFORM AT PORT MOUT UNDER GE MINNIE BAY
2023_MES_634434_1
8288/E8
Open Tender
Civil Works
Item Rate
180 days
Minniebay Port Blair
As per tender documents
10 documents required · 10 mandatory
₹500
GE Minniebay
₹96,000
Yes
21 Mar 2024
26 Dec 2023
29 Jan 2024
27 Dec 2023
26 Jan 2024
13 Jan 2024
Amount
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m depth for foundations, shafts, wells, cesspits manhole, pier holes etc n.exc 10 Sqm on plan and getting out in soft / loose soil complete all as specified and directed by Engineer-in-Charge.
M&L for Plain Cement Concrete Type D2 1:4:8 (using 40 mm graded stone aggregate) in foundations, filling and mass concrete including formwork complete all as specified and directed by Engineer-in-Charge.
M&L for Reinforced cement concrete M-30 (Design Mix) using 20mm graded stone aggregate as in foundations including rafts, footings, foundation beams, plinth beams, bases for columns etc basement slabs, under-reamed piles and mass concrete including formwork complete all as specified and directed by Engineer-in-Charge.
M&L for Reinforced cement concrete M-30 (Design Mix) using 20mm graded stone aggregate as in Column, Pillars, piers, posts and struts etc including formwork complete all as specified and directed by Engineer-in-Charge.
S&F for mild steel TMT bars of 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips or welded complete all as specified and directed by Engineer-in-Charge.
S&F for mild steel TMT bars of 10mm dia and over, stirrups, spacers and binders ends and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips or welded complete all as specified and directed by Engineer-in-Charge.
S&F for Mild steel Rolled section as in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to Fe.410-W.Gde-E-250 quality-A complete all as specified and directed by Engineer-in-Charge.
S&F Mild steel plates (Plain or chequered) channels, square cut or notched (Ordinary and counter sunk) forming holes, without any attachments Fe-410-W Gde - E - 250 quality - A complete all as specified and directed by Engineer-in-Charge.
S&F Mild steel rag or lewis bolts, dia of necks is 12mm screwed one end, with hexagonal or square nuts and washers, the other end enlarged and jagged or lewised, n exc 15cm long complete all as specified and directed by Engineer-in-Charge.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa trapezoidal profile as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed by Engineer-in-Charge.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, ridges, hips, valley gutter, drip, and straight flashing fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge.
S&F for Aluminium flat , wind ties of any size fixed with self tapping screws of size 40/50mm with integral EPDM washer screwed in roof covering, including all necessary drilling, bolting or riveting etc. and similar work complete all as specified and directed by Engineer-in-Charge.
M&L for Preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of yellow zinc chrome primer complete all as specified and directed by Engineer-in-Charge.
Surfaces excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft / loose soil complete all as specified and directed by Engineer-in-Charge.
M&L for Hardcore of Broken stone/boulders gauge n exc. 63mm, deposited, spread & levelled in layers n exc. 15 cm thick, watered & rammed to a true surface complete all as specified and directed by Engineer-in-Charge.
M&L 75mm thick cement concrete 1:4:8 type D-2 using 40mm graded stone aggregates as in sub base of flooring/hard standing including formwork complete all as specified and directed by Engineer-in-Charge.
M&L sand filling under floors or in foundations including watering and consolidation complete all as specified and directed by Engineer-in-Charge.
M&L for 60mm thick interlocking paver block with grey cement and pigment of any size and shape confirming to IS 15658-2006, M - 40 Grade laid in flooring and joints filled/broomed with fine sand complete all as specified and as directed.
M&L for providing cement concrete type B-1, 1:2:4 Nominal mix (using 20mm graded aggregate) as in coping, benching and similar works slightly rounded or chamfered angles and throating including necessary form work complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick of excavated soil complete all as specified and directed by Engineer-in-Charge.
Removal of excavated material [Soil] to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed by Engineer-in-Charge.
S&F Precast cement concrete block for kerbs stone with solid block exc 10cm in width type C-1, 1:3:6 (using 20mm graded stone aggregate) set in CM 1:6 of any shape and size as approved by Garrison Engineer, including necessary excavation and earth work including returning filling in the earth and removal of surplus soil from site if any, kerb stone shall be fixed in true line and level or in curves for edging of road side path including embedding PCC pre cast block in ground to any depth as required and tampering soil around PCC blocks complete all as specified and directed by Engineer-in-Charge.
M&L for Preparation of new or previously untreated concrete surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of primer complete all as specified and directed by Engineer-in-Charge.
M&L for pre-cast cement concrete block masonry with solid blocks,Type C1,1:3:6 (20mm graded aggregate) exc 10 cm in width and setting in CM 1:6 complete all as specified and directed by Engineer-in-Charge.
M & L for rendering 5 mm thick in cement mortar 1:4 over a backing coat of 10mm thick in CM 1:6 (Total 15 mm thick) on concrete or brick masonry surfaces and finishing the top surface even and fair without using extra cement complete all as specified and as directed by Engr-in-Charge.
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed by Engineer-in-Charge.
Material and labour for Plain Cement Concrete Type B2 1:2:4 Nominal mix (using 20 mm graded stone aggregate) in coping of walls, foundations, filling and mass concrete including formwork complete all as specified and as directed by Engr-in-Charge.
Material and labour for chipping out/ cutting holes of depth not exceeding 10cm into or through Plain cement concrete hardstanding/path, etc and clearing off debris from site outside MD land complete all as specified and directed by Engineer-in-Charge.
M & L point wiring with 1.5 Sq.mm (nominal area) PVC unsheathed multi stranded copper conductor PVC insulated 1100 volt FRLSH grade single core cable drawn through concealed/surface and including rigid steel conduit light grade ISI marked minimum 25mm size and its accessories complete along with 1.5 Sqmm PVC unsheathed multi stranded copper conductor cable but in green colour as continuous earthing wire and connecting to common earth dolly completely concealed ,ceiling/roofs with and including 1.2 mm thick MS sheet terminal boxes duly fabricated/Welding mounted on MS post for mounting switches,switch socket combinations fan regulators etc as required with 3 mm thick plastic laminated sheet top cover complete all as specified and directed by Engineer-in-Charge for the following:-
One light /fan point controlled by one switch complete all as specified and directed by Engineer-in-Charge.
All as per item No 29.00 above but with 2.5 Sqmm single core multi stranded unsheathed copper conductor for one three pin socket 15 Amps on independant board including continuous earth wire PVC insulated 2.5 Sqmm copper solid conductor to common earth dolly complete all as specified and directed by Engineer-in-Charge.
S&F Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp box type universal complete all as specified and directed by Engineer-in-Charge.
S&F Switch piano, flush type single pole, one way 5 Amp complete all as specified and directed by Engineer-in-Charge.
M&L for Sub main wiring complete with 2 x 2.5 sqmm, single core, multi stranded copper conductor FRLSH PVC insulated and sheathed cable 1100 volts grade, drawn in 25mm steel conduit on surface/wall/MS truss/ (as required) a etc including 2.5 sqmmm size pvc insulated sheathed FRSLH copper earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed by Engineer-in-Charge. Note (i) All three wire/cable (phase, neutral and earth) should be run through for each individual circuit from the DBs. (ii) Two run/four runs of cable and one run/two runs of earth conductor and PVC Conduit/Casing Caping be measured as one length.
S&F steel metal flexible conduit pipe dia of 16 to 19mm fixed on Mild Steel post trusses complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of DB SPN 6 way with category of protection double door type IP-42 factory made with tinned copper 200 Amps rated bus bar suitable for MCBs all as specified and as directed by Engineer-in-Charge. Note : The DB shall be fixed on structural steel with iron clamp, welding complete .
Supply and fix MCB TPN 63 Amps, 415 volts, 10 KA 'C' Curve complete all as specified and directed by Engineer-in-Charge.
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, complete with connection testing and commissioning complete all as specified and directed by Engineer-in-Charge.
Supply and fixing 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of SPN and current carrying capacity of 40 AMP, in the SPN DB complete all as specified and directed by Engineer-in-Charge.
Supply and lay, testing and commissioning of LT UG cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) 1100Volts grade, with stranded aluminium conductor of size 25 Sqmm x 3.5 Core,Suitable gland ,crimping ,lugging ,Before and after laying of cable insulation test report to be submitted complete all as specified and directed by Engineer-in-Charge.
Supplying and laying GI tubing 40mm bore ISI marked medium grade for cable protection in trenches/duct/fixing to pole/wall or in such similar position complete all as specified and directed by Engineer-in-Charge.
Excavation in hard / dense soil Including road/PQC cutting etc not exceeding 1.5 mtr wide and n exc 1.5m depth and getting out including forming of bottom for laying cable complete all as specified and directed by Engineer-in-Charge.
M&L for earthing complete with GI earth electrode of size 60cmx60cmx6mm buried directly in ground vertically at a depth not less than 2.25 meter below normal ground level with top edge of earth plate at a depth not less than 1.5 meter below normal ground surrounded from all sides by 15 CM thick and packed layer of charcoal dust and common salt filling in alternate layers cleaned connected to and including GI earth plate 32x6mm size upto 7.5 mtr by means of bolts, nuts, check nuts and washers made of galvanised iron and protected light grade 50 mm dia 5 mtr long GI pipe connected to main control board and GI pipe light grade 20 mm bore for watering and including funnel wire mesh, RCC pit cover 50 mm thick with 10 mm dia reinforcement 100mm c/c and PCC chamber pit with PCC 1:2:4 type C-2 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 meter) and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 all as specified and directed by Engineer-in-Charge.
Supply, laying of Telerex DWC (double Wall corrugated) HDPE pipe ISI marked of outer dia of 50 mm and inner dia 38 mm polethylene including couplers, bends, cap etc., with smooth internal and profiled external surface for non pressure under ground cable complete all as specified and directed by Engineer-in-Charge.
Supply & Fix Turbo Force wall mounting fan , 600 mm Sweep 240 volt, Single Phase IP 65 protection with die cast alluminum hosing, jerk free oscillation & smooth running comprising of high performance high speed motor for higher air delivery incl provision of three core flexible PVC cable with stranded copper conductor size 1.5 sqmm connecting up to the metal ceiling rose including all accessories, Welding mounted on MS Trusses, complete all as specified and directed by Engineer-in-Charge. Make: Havells cat Part No FHACPSTSCL24 or equivalent in Bajaj or Crompton
Supply and fix energy saving and environmental friendly longlife LED flood light/High bay 80 Watt, COB type made up of pressure die cast aluminium housing with IP 65 protection including all fixing arrangement, brackets, nut bolt, washer and connected from ceiling rose with tri colour flexible copper cable Welding mounted to MS Trusses ,connection complete all as specified and directed by Engineer-in-Charge.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection completeand accessories complete mounted on 40 mm dia light grade GI pipe bracket 1.0 mtr long bent to shape, painted, Welding mounted to MS Trusses ,connectioncomplete all as specified and directed by Engineer-in-Charge.
M/s Sriya Enterprises
Allied Trading Company
M/s Pooja Enterprises
bansal construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .