| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹17.9 LAdmitted-Finance | -8.50% | ₹17.9 L | L1 | Admitted-Finance |
| 2 | L2₹18.2 LAdmitted-Finance | -7.00% | ₹18.2 L | L2 | Admitted-Finance |
| 3 | L3₹20.0 LAdmitted-Finance | +2.00% | ₹20.0 L | L3 | Admitted-Finance |
Updated dates
Tender Value
₹19.6 L
EMD Value
₹39,180
Closing Date
5 Mar 2026, 6:00 pmClosed
Executive Engineer
S and D Div. West Jammu
Restoration of damaged HDPE Pipes (Special Sewer) laid/fixed on various nallah walls at different spots under Div-A Ph-II of Jammu City executed by JKERA). Contract No SDJ/W/98/2025-26
2026_HAUDD_303556_1
E-NIT No 53 of 2025-26 Dated 16-02-2026
Open Tender
Civil Works
90 days
Jammu
refer PQ terms and conditions
2 documents required · 2 mandatory
₹600
Executive Engineer, SandD Division (West), Jammu
₹39,180
4 Apr 2026
17 Feb 2026
6 Mar 2026
17 Feb 2026
5 Mar 2026
17 Feb 2026
Demolishing cement concrete manually/ mechanical means including disposal of material within 50mt leads as per direction Engineer(1:3:6) or richer mix
Demolishing RCC work manually/ mechanical means including stacking of steel bars and disposal of unsrvicable material within 50mt leads as per direction Engineer or richer mix
Providing, Laying, Jointing, Testing and Commissioning of High Density Polyethylene pipes, (HDPE), PE-80 grade, PN-6, confirming to IS:14333 for sewergae network by way of grouting clamps etc. The work shall include all costs for the supply of pipes, jointing material and other materials, transport, plant, labour and equipment for excavating, shoring, dewatering, formation preparation, bedding, installing to true line and level, fittings and jointing, testing, surrounding, backfilling, compacting, temporary surface reinstatement, disposal of surplus excavated materials within 15 Kms., etc. under the designed sewerage system in conformance with the Technical Specification wherever required.
160 mm dia
200 mm dia
Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. 110 mm dia (outer diameter)
Structural steel in built up sections, trusses and framed works, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete (welded)
Engaging sewer man (02no)
P/L cement concrete in 1:3:6 mix all work upto plinth level (stone aggregate 20mm) nominal size
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
technical_985792.pdf
techsummary_985792.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.31 MB
BOQ_985792.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid