| 1 | L1₹42.5 LAccepted-Finance 894 NEAR 132 KV POWER HOUSE SINDHARI ROAD BALDEV NAGAR BARMER RAJ 344001 | BARMER | RAJASTHAN | 344001 | L1 | Accepted-Finance LOWEST | |
| 2 | L2₹43.6 L+₹1.2 L (2.74%)Rejected-Finance 205 IIND PHASE INDUSTRIAL AREA BARMER 344001 | BARMER | BARMER | RAJASTHAN | 344001 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹48.5 L+₹6.0 L (14.1%)Rejected-Finance NO 28 KUMHARON KI BASTI DHOONDHA BARMER RAJASTHAN 344035 | BARMER | RAJASTHAN | 344035 | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹50.7 L+₹8.2 L (19.4%)Rejected-Finance | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹63.3 L+₹20.9 L (49.2%)Rejected-Finance 2 EVEREST VIHAR PT T N MISHRA MARG NIRMAN NAGAR JAIPUR 302019 | JAIPUR | RAJASTHAN | 302019 | L5 | Rejected-Finance NOT LOWEST |
| Sl No | Description | Qty | Unit | Rasam Engg Co. L5 | National Rewinding Works L2 | Devi Engineeing L4 | DEVARAM CONSTRUCTION COMPANY L3 | GITANSH ENGINEERS AND COMPANY L1 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling of depriciated cross arms (Clamp, nut bolts )/ channels/ supports etc care fully from site and setting aside for reuse or for taking credit all as specified and directed. | 0.7 | Qtl | 400 ₹280 | 100 ₹70 Lowest | 600 ₹420 | 395 ₹276.5 | 100 ₹70 Lowest |
| 2.00 | Material and labour for steel structure, cross arms, bracing supports ,clamps, back plates febricated from structrual steel sections incl. nuts, bolts, washers, welding ,bending cold or hot drilling holes for bolts in any size and shape all as directed Including one primer coat, one under coat and one finishing coat of synthetic enamel steel paints incl preparation of surface all as directed. | 0.5 | Qtl | 800 ₹400 | 100 ₹50 Lowest | 6,500 ₹3,250 | 6,990 ₹3,495 | 8,000 ₹4,000 |
| 3.00 | Restringing/Tightening only of ACSR conductor of any type and size of street / security light feeder including straightening properly on insulators and binding with aluminum taps /binding wire /conductor jumper etc complete of any size all as directed. Note : - Single conductor shall be measured for length re-stringing. | 400 | RM | 10 ₹4,000 | 10 ₹4,000 | 10 ₹4,000 | 5 ₹2,000 | 3 ₹1,200 Lowest |
| 4.00 | Dismantling of ACSR conductor of any type and size from existing PCC/Steel poles at various locations all as directed by Engr - in - charge at site. | 6.52 | Qtl | 200 ₹1,304 | 100 ₹652 Lowest | 500 ₹3,260 | 180 ₹1,173.6 | 150 ₹978 |
| 5.00 | Material and labour in replacement of ACSR conductor straightening properly on insulators and binding with aluminum taps /binding wire /conductor jumper etc complete all as directed by Engr- In- Charge. | 0.5 | Qtl | 20,000 ₹10,000 | 8,000 ₹4,000 | 6,500 ₹3,250 Lowest | 8,000 ₹4,000 | 10,000 ₹5,000 |
| 6.00 | Dismantling of insulators of any size/type from existing PCC/Steel poles all as directed by Engr - in - charge at site. | 45 | Each | 5 ₹225 | 50 ₹2,250 | 25 ₹1,125 | 98 ₹4,410 | 2 ₹90 Lowest |
| 7.00 | Supply and fix pin type porcelain insulator, vitreous brown insulator including one galvanised mild steel spindle with two GI washer and one GI Nuts 100 mm height 65 mm dia for 1100 volts grade incl taking down old unsv insulator from PCC/Steel pole complete all as specified and directed by Engr-in-Charge. . | 10 | Each | 100 ₹1,000 | 100 ₹1,000 | 150 ₹1,500 | 100 ₹1,000 | 65 ₹650 Lowest |
| 8.00 | Supply and fix shackle type porcelain vitreous Brown insulator 1100 volt grade 75 mm in height and 90 mm dia including galvanised mild steel strap of size 31mm x 3mm , 12 mm dia insulators bolts, washers and nuts complete all as specified. | 10 | Each | 150 ₹1,500 | 100 ₹1,000 | 200 ₹2,000 | 90 ₹900 | 65 ₹650 Lowest |
| 9.00 | Excavation in trenches n.exc 1.5 m wide and n.exc 1.5m depth for taking out, laying of cables etc and getting out in soft/loose soil incl connected items complete all as specified and directed by Engr-in-Charge. | 553 | Cum | 150 ₹82,950 | 150 ₹82,950 | 140 ₹77,420 | 108 ₹59,724 Lowest | 140 ₹77,420 |
| 10.00 | Returning, filling in, including spreading levelling, watering and well ramming in layers not exc 25 cm in depth (soil) all as specified and directed by Engr-in-Charge. | 275 | Cum | 50 ₹13,750 | 50 ₹13,750 | 50 ₹13,750 | 50 ₹13,750 | 41 ₹11,275 Lowest |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
3 Nov 2025, 6:00 pmClosed
GE (A) BARMER
JALIPA CANTT GE (A) BARMER
MAINT REPAIRS REPLACEMENT OF LT OVER HEAD LINE LT UG CABLE OF LT DISTRIBUTION SYSTEM INCLUDING ALLIED WORKS IN POCKET B AND LT CONTROL PANEL BOARDS AT DIFFERENT MES INSTALLATION INCLUDING ALLIED WORKS AT JASAI MIL STN UNDER GE A BARMER
2025_MES_733571_1
8862/E8
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
BARMER
Please refer Tender documents
8 documents required · 8 mandatory
₹500
Yes
₹90,000
Yes
21 Jan 2026
2 Oct 2025
5 Nov 2025
2 Oct 2025
3 Nov 2025
16 Oct 2025
Amount
Dismantling of depriciated cross arms (Clamp, nut bolts )/ channels/ supports etc care fully from site and setting aside for reuse or for taking credit all as specified and directed.
Material and labour for steel structure, cross arms, bracing supports ,clamps, back plates febricated from structrual steel sections incl. nuts, bolts, washers, welding ,bending cold or hot drilling holes for bolts in any size and shape all as directed Including one primer coat, one under coat and one finishing coat of synthetic enamel steel paints incl preparation of surface all as directed.
Restringing/Tightening only of ACSR conductor of any type and size of street / security light feeder including straightening properly on insulators and binding with aluminum taps /binding wire /conductor jumper etc complete of any size all as directed. Note : - Single conductor shall be measured for length re-stringing.
Dismantling of ACSR conductor of any type and size from existing PCC/Steel poles at various locations all as directed by Engr - in - charge at site.
Material and labour in replacement of ACSR conductor straightening properly on insulators and binding with aluminum taps /binding wire /conductor jumper etc complete all as directed by Engr- In- Charge.
Dismantling of insulators of any size/type from existing PCC/Steel poles all as directed by Engr - in - charge at site.
Supply and fix pin type porcelain insulator, vitreous brown insulator including one galvanised mild steel spindle with two GI washer and one GI Nuts 100 mm height 65 mm dia for 1100 volts grade incl taking down old unsv insulator from PCC/Steel pole complete all as specified and directed by Engr-in-Charge. .
Supply and fix shackle type porcelain vitreous Brown insulator 1100 volt grade 75 mm in height and 90 mm dia including galvanised mild steel strap of size 31mm x 3mm , 12 mm dia insulators bolts, washers and nuts complete all as specified.
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5m depth for taking out, laying of cables etc and getting out in soft/loose soil incl connected items complete all as specified and directed by Engr-in-Charge.
Returning, filling in, including spreading levelling, watering and well ramming in layers not exc 25 cm in depth (soil) all as specified and directed by Engr-in-Charge.
Removing excavated material (soil) to a distance not exc 50 m and depositing where directed at a level not exc 1.5m above the starting point all as specified and directed by Engr-in-Charge.
Supply and spreading clean dry (Tibba) Sand including watering and consolidation in trenches for cushioning/cable protection all as specified and directed by Engr-in-Charge. Note : Punned thickness shall be measured and paid
Supply and laying un-reinforced precast concrete cable cover, class LV, type 1, flat size 250 mm x 150 mm x 40 mm and abutting each other with gap between adjacent precast concrete cable cover not exceeding 10 mm over underground cables in trenches for cable protection of U/G cables with width equal to length of bricks complete all as specified and directed
M&L for PCC (1:2:4) type B1, using (20mm graded stone aggregate) for coping of poles including necessary form work etc complete all as specified and directed by Engr-in-Charge.
M&L for providing PCC 1:3:6 type C2, Using 40mm graded aggregate for Cement concrete in foundations, filling and mass concrete including necessary form work etc complete all as specified and directed.
M&L for GI pipe of bore 100 mm, light grade with all running fittings (ISI Marked), laid in trenches, under road or fixing on wall/pole/crossing drain/nallah etc., complete all as specified and directed. Make : TATA/JINDAL/PRAKASH. Note : Wherever GI Protection pipes are to be placed/fitted above earths surface, cost of necessary clamping/fixing arrangements to the entire satisfaction of Engr-In-Charge is deemed to be included in the unit quoted rates.
All as per Item No. 16.00 here-in-above, but 80 mm bore GI pipe.
All as per Item No. 16.00 here-in-above, but 50 mm bore GI pipe.
All as per Item No. 16.00 here-in-above, but 40 mm bore GI pipe.
M&L for boring under road manually with labour suitable for inserting upto 100 mm bore pipe at a depth 0.75 to 1.0 mtr complete.
Supply and laying High density Polyethelene pipe (HDPE) of dia 50mm for cable protection in trenches/ducts/floors or fixed on walls / roof etc including suitable fixing accessories complete all as specified and directed by Engr-in-Charge. Note :- Wherever the protection pipes are to be laid/fixed on poles/walls/other surface the cost of clamping using appropriate size/type of MS clamps,nuts both etc is deemed to be included in the unit quoted rates.
M&L for cutting the existing hardstanding/PCC/WBM road at a depth of not less than 60 cm & 30 cm in width for passing of HT cables through GI pipes, returning filling in, complete incl finishing the surfaces by providing cement concrete type B1 (1:2:4) with 20 mm graded aggregate upto 20 cm, finishing to a uniform smooth surface complete all as specified and as directed.
NOTE for item 1.00 to 22.00 :- Any damages made to the existing services of MES/PHED/Defence nits/Other Depts like HT/LT UG cables, Water Supply/Sewage Pipe lines, OFC/BSNL/Signal communication cables etc. during the excavation/boring/road cuting etc. progress of the work shall be made good with proper jointing kits etc. as per original to the entire satisfaction of Engr-In-Charge & GE & the cost of the same is deemed to be included in the unit quoted rates. Decision of the AO shall be final & binding.
Taking out old unserviceable, burnt, punctured aluminium conductor cable LT, PVC/XLPE, 1100 volts grade, of cross sectional area upto 240 Sqmm all as specified and directed by Engr-in-Charge.
Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2.0 core in trenches / through GI pipe / fixed along with pole structure etc with all fixing & connecting accessories like Clamps,Lugs and Glands complete all as specified & as directed.
All as per Item No. 24.00here-in-above, but cable size is 6 Sqmm 2.0 core.
All as per Item No. 24.00here-in-above, but cable size is 10 Sqmm 4.0 core.
All as per Item No. 24.00here-in-above, but cable size is 16 Sqmm 4.0 core.
All as per Item No. 24.00here-in-above, but cable size is 25 Sqmm 4.0 core.
All as per Item No. 24.00here-in-above, but cable size is 35 Sqmm 3.5 core.
All as per Item No. 24.00here-in-above, but cable size is 50 Sqmm 3.5 core.
All as per Item No. 24.00here-in-above, but cable size is 70 Sqmm 3.5 core.
All as per Item No. 24.00here-in-above, but cable size is 95 Sqmm 3.5 core.
All as per Item No. 24.00here-in-above, but cable size is 120 Sqmm 3.5 core.
All as per Item No. 24.00here-in-above, but cable size is 150 Sqmm 3.5 core.
All as per Item No. 24.00here-in-above, but cable size is 185 Sqmm 3.5 core.
M&L for earthing complete with Copper earth plate electrode 600 x 600 x 3.15 mm thick buried directly in ground (in vertical position) earth pit not less than 2.25 mtr below normal ground level with the top edge of the earth plate not less than 1.5 mtr (B.G.L.) and connected to copper earth strip 20 x 3 mm by means of bolts, nuts, check nuts, and washers of galvanized iron including PCC pit & cover with suitable handle, including necessary excavation and earth work in any type of soil, 20 mm dia med grade galvanized steel tube for watering with one end fixed with suitable funnel and wire mesh, 40 mm bore medium grade galvanized steel tubing for drawing earth lead GI strip protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 Incl Taking down old Existing Unserviceable Earthing of any type alongwith Connected items complete all as specified and as directed and testing on completion complete.
M&L for earthing complete with Galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (in vertical position) earth pit not less than 2.25 mtr below normal ground level with the top edge of the earth plate not less than 1.5 mtr (B.G.L.) and connected to GI earth strip 32 x 6 mm by means of bolts, nuts, check nuts, and washers of galvanized iron including PCC pit & cover with suitable handle, including necessary excavation and earth work in any type of soil, 20 mm dia med grade galvanized steel tube for watering with one end fixed with suitable funnel and wire mesh, 40 mm bore medium grade galvanized steel tubing for drawing earth lead GI strip protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1Incl Taking down old Existing Unserviceable Earthing of any type alongwith Connected items complete all as specified and as directed and testing on completion complete.
NOTE : for item No. 36 & 37 1) On completion of the complete work/job the Contr is to perform earth resistance tests for each earthing job in the presence of the Engr-In-Charge or his rep. If the test results are not satisfactory or not within the permissible limits of relevant Standards/IS then the job is to be redone without any extra cost to the Dept till the results are satisfactory.
M&L for River-Sand filling, levelling, watering & consolidation in 15 cm layers on the level ground surface in Sub-Stns complete all as specified & as directed by the Engr-In-Charge.
M&L for spreading & leveling of stone aggregates of size 20 to 25 mm on sand filling in the Sub-Stns complete all as specified & as directed by the Engr-In-Charge.
M&L for cutting grass, bushes, creapers, weeds, unwanted plants/growths, area cleaning etc in and arround Electric Supply Installations, LT Panels, Feeder Pillar Boxes or any other locations as decided by Engr-In-Charge/GE and removing rubbish off the premises complete all as specified and to the entire satisfaction of the Engr-in-charge.
M&L for preparation of old painted steel surfaces of outdoor/indoor type LT/HT Panels, Feeder Pillar/Junction boxes etc. of any size/type etc. after cleaning of oils, wax, lubricants, grease, rusty scales, spider webs, dusts etc. complete & applying one coat of synthetic enamel paint of approved colour & grade using spray gun & neatly writing distribution details (if applicable) complete all as specified & as directed by the Engr-In-Charge.
M&L for straight through joint, heat shrink type for LT UG Cable incl joint kits suitable for Aluminium conductor cable of size 25 to 50 Sqmm 4/3.5 core incl earthwork, taking down, preparation of damaged cable incl testing complete all as specified & as directed by the Engr-In-Charge. Make : DENSON/3M/YAMUNA/RAYCHEM.
All as per Item No. 42.00 here-in-above, but suitable for Aluminium conductor cable of size 70 to 150 Sqmm 3.5 core.
M&L for outdoor jointing kit suitable for XLPE/ PVC Cable 1100 volts grade, heat shrinkable type for indoor/ outdoor applications complete including preparing ends of cable all as directed and specified as under :- (a) 25 to 50 sqmm 3.5 /4 core Make : DENSON/3M/YAMUNA/RAYCHEM.
All as per Item No. 44.00 here-in-above, but suitable for 70 to 150 sqmm 3.5 core cable size
All as per Item No. 44.00 here-in-above, but suitable for 185 to 300 sqmm 3.5 core cable size
M&L for preparation of old painted steel surfaces of LT/HT/Security/Street light steel tubular poles incl MS Clamps, cross arms, GI Pipe brackets etc. of any size/type etc. after cleaning/removal of oils, wax, lubricants, grease, rusty scales, spider webs, dusts etc. & applying one coat of Aluminium paint above Coping/GL incl painting of pole coping with Black colour and writing pole No. all as specified and directed by Engr-in-charge
Material and Labour for preparation of old painted surfaces for ZEBRA painting of PCC/steel poles 9/11 m long alongwith road/Perimiter wall with one coat of enamel synthetic paints using yellow and Black colour in alternate layer of 30 cm upto 1.5 mtr above Coping/GL incl painting of pole coping with Black colour and writing pole No. all as specified and directed by Engr-in-charge
S & F in replacement of Steel tubular swaged poles, 9 meters long complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 inclusive of one primer coat of red oxide zinc chrome primer and two coats of aluminium paint including preparation of surfaces and writing Pole No complete incl Dismantling of old existing PCC Pole alongwith PCC Coping and removing from site complete all as specified and directed by Engr-in-Charge.Make:IndiaTube&Co/India Electric Poles/National Tubing Co./Sankhla Udyog Note : (i) Design/Drawing/BOM of pole is to be obtained from the Maufacturer/Authorised supplier and the same is to be got approved from Engr-in-Charge prior to making order to the Manufacturer/Supplier. (ii) Earth work and PCC shall be measured & paid separately.
Regular maintenance of existing APFC panel with cleaning of dust inside by blower and cleaning of moving parts / contacts from CT cleaner, tightening of loose parts/ electrical wires, cleaning of contactors, relays and capacitors, junction point,servicing, oiling to cooling fan including testing of APFC relay with necessary setting with CTs / load adjustments to match with the APFC load management system complete with replacement of worn out unserviceable components / burnt wires/ timbles/ lugs of capacity 10 KVAR to 60 KVAR complete all as specified and as directed. NOTE :- (i) There are 15 Nos of APFC panel installed at different locations in Mil stn jassai and all the panels are to be maintained for the complete contract period . (ii) The power factor (PF) for all the 17 Nos APFC panel should be in between 0.95 to 0.99 , in case the PF is less than the power factor maintain above due to any reason, then the contractor shall liable to pay compenssation equivalent to JVVNL tarrif . (iii) The spare parts shall be of same make and capacity of existing one and shall be measured and paid separately. (iv) Replacement of bolt / nut / screws etc. shall deemed to be included in ther rate quoted. (v) Interval of maintenance shall be according to Engr-In-Charge at site
Material and labour for repair to outdoor type double door LT panels/Feeder pillar box by repairing/replacing hinges at site by replacing unserviceable pedestal locks, replacing unserviceable bow handle and connected accessories of front, rear and inner doors by welding, cutting, drilling etc and incl fixing with MS nuts and bolts and repair/ replacing of copper bus bar of various rating suitable along with RYB insulation including cable end terminal aluminium lugs and including spray painting with two coats of approved grade & color synthetic enamel paint after scrapping incl preparation of old painted surfaces over entire LT panel surfeces (Internal and external) of MS sheets and angles complete all as specified and directed at site. (Note : Copper bus bar and porcelain insulators, Meter to be measured and paid under separate Sch 'A' item)
Supply and fix in replacement of old unserviceable voltmeter/ammeter/Multi-function meter with panel mounted multi function three phase digital meter of accuracy Cl-1.0 for measuring V, A,F,PF,KW,Kva, KWh duly painted complete all as specified and directed. Make: Legrand/Schneider/Siemens/ABB/L&T
Supply and fix in replacement of old unserviceable indicators any type with LED based indicating lamps of RYB or any colour in APFC Panel/LT/Bus Bar panel incl disconnecting and connecting of the same complete all as specified and directed.
Supply and fix in replacement of epoxy cast/polymer glass1100V grade insulators on the bus bars/panel complete all as specified and directed.
Supply and fixing in replacement of 200 Amp, 36 KA, 4 pole, thermal magnetic unserviceable MCCB etc suitable for 415 Volts 3 Phase 4 wire system complete all as specified and directed. Make of MCCB : Legrand/ABB/Indoasian/L&T Note : MCCBs shall be lcu=lcs=100%
All as per srl item no 55 above but MCCB, AC, 415 volts, 160 Amp, 36 KA, 4 pole, thermal magnetic
All as per srl item no 55 above but MCCB, 125 Amp, 415 volts, 16 KA, 4 pole, thermal magnetic
All as per srl item no 55 above but MCCB, 100 Amp, 415 volts, 16 KA, 4 pole, thermal magnetic
All as per srl item no 55 above but MCCB, 63 Amp, 415 volts, 16 KA, 4 pole, thermal magnetic
S & F Sheet metal enclosure , IP-30. IK-08 where MCCBs to be used, 4 Pole, 415 Volt, Single Door with Suitable louvers for heat dissipation and inbuilt neutral link for TPN sustem ISI marked, cable to be cconnected through suitable lugs and gland complete all as specified and as directed by Engr-in-charge. Make : LK, Cat No CM91003OOOO or techno-commercially equiv in Legrand/Havells.
Supply only in replacement of MCB TPN 415 Volts 10KA, C curve 06-32 Amps in existing panel of the same make in existing MCB to match with existing holes/surface complete all as specified and directed.
Supply only in replacement of MCB TPN 415 Volts 10KA, C curve 40-63 Amps in existing panel of the same make in existing MCB to match with existing holes/surface complete all as specified and directed.
Supply only in replacement of MCB TP 415 Volts 10KA, C curve 06-32 Amps in existing panel of the same make in existing MCB to match with existing holes/surface complete all as specified and directed.
Supply only in replacement of MCB TP 415 Volts 10KA, C curve 40-63 Amps in existing panel of the same make in existing MCB to match with existing holes/surface complete all as specified and directed.
Supply only in replacement of 3 Pole power contactor (capacitor duty type) 415 V of capacity 9 Amps Confirming to IS/IEC 60947-4-1 complete all as specified and directed.
Supply only in replacement of 3 Pole power contactor (capacitor duty type) 415 V of capacity 12 Amps Confirming to IS/IEC 60947-4-1 complete all as specified and directed.
Supply only in replacement of 3 Pole power contactor (capacitor duty type) 415 V of capacity 18-22 Amps Confirming to IS/IEC 60947-4-1 complete all as specified and directed.
Supply only in replacement of 3 Pole power contactor (capacitor duty type) 415 V of capacity 32 Amps Confirming to IS/IEC 60947-4-1 complete all as specified and directed.
Supply only in replacement of capacitor 440 volts 50 HZ APP type electric conforming to IS: 13340/13441 & IEC-831-1 of capacity 1 KVAR complete all as specified and directed.
Supply only in replacement of capacitor 440 volts 50 HZ APP type electric conforming to IS: 13340/13441 & IEC-831-1 of capacity 2 KVAR complete all as specified and directed.
Supply only in replacement of capacitor 440 volts 50 HZ APP type electric conforming to IS: 13340/13441 & IEC-831-1 of capacity 3 KVAR complete all as specified and directed.
Supply only in replacement of capacitor 440 volts 50 HZ APP type electric conforming to IS: 13340/13441 & IEC-831-1 of capacity 4 KVAR complete all as specified and directed.
Supply only in replacement of capacitor 440 volts 50 HZ APP type electric conforming to IS: 13340/13441 & IEC-831-1 of capacity 5 KVAR complete all as specified and directed.
Supply only in replacement of capacitor 440 volts 50 HZ APP type electric conforming to IS: 13340/13441 & IEC-831-1 of capacity 8 KVAR complete all as specified and directed.
Supply only in replacement of capacitor 440 volts 50 HZ APP type electric conforming to IS: 13340/13441 & IEC-831-1 of capacity 10 KVAR complete all as specified and directed.
Supply only in replacement of capacitor 440 volts 50 HZ APP type electric conforming to IS: 13340/13441 & IEC-831-1 of capacity 15 KVAR complete all as specified and directed.
Supply only in replacement of capacitor 440 volts 50 HZ APP type electric conforming to IS: 13340/13441 & IEC-831-1 of capacity 20 KVAR complete all as specified and directed.
Supply only in replacement of capacitor 440 volts 50 HZ APP type electric conforming to IS: 13340/13441 & IEC-831-1 of capacity 25 KVAR complete all as specified and directed.
Supply only in replacement of APFC Controller suitable for measuring 3 phase current and voltage, Displaying PF upto 3 digit after decimal, having dual PF setting for Mains & DG Application including necessary Connection and communication with existing system complete all as specified and directed.
Supply only in replacement of Ampere meter digital type 0 to 100 amps capacity complete all as specified and directed.
Supply only in replacement of CTs suitable for ampere meter 100/5 Amps Rating complete all as specified and directed.
Supply only in replacement of CTs suitable for 200/5 Amps Rating complete all as specified and directed.
Supply only in replacement of CTs suitable for 60/5 Amps Rating complete all as specified and directed.
Supply only in replacement of APFC relay square flush type with protective device intelligent automatic processor based on electronic controller 6 stages for APFC panel complete all as specified and directed.
Supply only in replacement of APFC relay square flush type with protective device intelligent automatic processor based on electronic controller 8 to 14 stages for APFC panel complete all as specified and directed.
M&L in replacement for stay assembly complete with 230x230x 6 mm thick plate and 16 mm dia stay rod all as shown in elect plate No-1 of SSR-part-1 including stay wire of size 7/4mm dia and suitable loop insulator of appropriate size incl taking down old unsv stay wire of any type complete all as specified & as directed. Note : Rate quoted is deemed to be included of excavation in any type of soil, PCC for stay and dismantling of old stay assy.
S&F in repair name board acrylic type (280mm x 400mm) of incoming or outgoing feeders,caution board etc with radium glow sign reflector type on acrylic board incl clamp of suitable size, nut, bolt etc complete all as specified and directed.
Material and labour for writing pole number of minimum size 10 cm height with black paint over base of yellow paint on PCC/steel poles of LT/HT supply complete all as specified and directed.
Supply, install, testing & commissioning of LT busbar junction box "out-door type" of size 750 mm (height) x 750 mm (breadth) x 300 mm (depth) (minimum dimensions), factory fabricated CPRI approved (type-tested) with suitable neoprene rubber gasket to make it completely dust & vermin proof & degree of protection not less than IP-55 & general construction confirming to IS-13947, double door, front & back openable. The box shall be provided with ventilation facility in the form of louvers for better heat dissipation & high grade Copper bus-bar of rating 250A of length 550mm, min spacing of 80mm between the busbars & wrapped with coloured PVC tape /sleeves of rating in conformity to the Incoming cable rating. The panel board shall be fabricated out of 3.15 mm thick (for outer portions) & 2.00 mm thick (for inner portions) CRCA sheet duly pre-treated & powder coated, supporting angle iron frame of height 60cm from GL & MC channel base suitable for 3 Phase, 4 wire system 415 /440 volts grade including I/C & O/G cable opening on bottom & at both sides including cable glands of suitable sizes with suitable PCC (1:3:6) type C-2 foundation , necessary earthwork (if any) incl taking down old unsv box of any size/type complete all as specified & as directed.
Supply, install, testing & commissioning of LT control panel board "out-door type" of size 1500 mm (height) x 1200 mm (breadth) x 500 mm (depth) (minimum dimensions), factory fabricated CPRI approved (type-tested) with suitable neoprene rubber gasket to make it completely dust & vermin proof & degree of protection not less than IP-55 & general construction confirming to IS-13947, double door, front & back openable. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation & high grade Copper bus-bar wrapped with coloured PVC tape /sleeves of rating in conformity to the Incoming ACB/MCCB rating. The panel board shall be fabricated out of 3.00 mm thick (for outer portions) & 2.00 mm thick (for inner portions) CRCA sheet duly pre-treated & powder coated, supporting angle iron frame of size 50X50X6mm fixed at 75 cm height from groud level & MC channel base suitable for 3 Phase, 4 wire system 415 /440 volts grade including complete internal wiring with not less than 2.5 Sqmm copper wire including cable glands and lugs of suitable sizes with suitable PCC (1:3:6) type C-2 foundation , necessary earthwork (if any) incl taking down old unsv box/Panel of any size/type complete all as specified & as directed. with & including the following accessories :
(i) BUS-BAR & INTERNAL CONNECTIONS : The bus-bars shall be made up of 04 Nos high grade Copper with rating should be suitable as per incoming Breaker, duly insulated with 1100 Volts grade standard colour coded PVC sleeves & rigidly mounted on suitable sized "F" class insulators of non-hygroscopic, non-combustible, all internal connections from main bus-bars to switch gears etc. PROVISION FOR CABLE ENTRY : The provision for cable entry /exit shall be provided in the bottom for both incoming & out-going cables with the help of glands matching the existing LT cable sizes. INCOMING : (a) MCCB 4 Pole (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting, suitable for isolation, having breaking capacity 25 KA & of rating 160-200 A - 01 Nos. Make : L & T, Cat No : CM90642OONO or techno-commercially equivalent of Legrand /Siemens
OUTGOINGS : (a) MCCB 4 Pole (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting, suitable for isolation, having breaking capacity 25 KA & of rating 125-160 A - 01 Nos. Make : L & T, Cat No : CM90642OOMO or techno-commercially equivalent of Legrand /Siemens (b) MCCB 4 Pole (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting, suitable for isolation, having breaking capacity 25 KA & of rating 80 to 100 A - 02 No. Make : L & T, Cat No : CM91712OOKOOG or techno-commercially equivalent of Legrand /Siemens (c) MCCB 4 Pole (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting, suitable for isolation, having breaking capacity 25 KA & of rating 63 to 80 A - 02 Nos. Make : L & T, Cat No : CM91712OOJOOG or techno-commercially equivalent of Legrand /Siemens. (d) MCB TPN "C" series having breaking capacity 10 KA of rating 40 to 63 Amps - 03 No. Make : L&T/Legrand /Siemens. (e) MCB SPN "C" series having breaking capacity 10 KA of rating 06 to 32 Amps - 04 No. Make : L&T /Legrand /Siemens.
Supply, install, testing & commissioning of LT control panel board "out-door type" of size 1800 mm (height) x 1500 mm (breadth) x 500 mm (depth) (minimum dimensions), factory fabricated CPRI approved (type-tested) with suitable neoprene rubber gasket to make it completely dust & vermin proof & degree of protection not less than IP-55 & general construction confirming to IS-13947, double door, front & back openable. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation & high grade Copper bus-bar wrapped with coloured PVC tape /sleeves of rating in conformity to the Incoming ACB/MCCB rating. The panel board shall be fabricated out of 3.00 mm thick (for outer portions) & 2.00 mm thick (for inner portions) CRCA sheet duly pre-treated & powder coated, supporting angle iron frame of size 50X50X6mm fixed at 75 cm height from ground level & MC channel base suitable for 3 Phase, 4 wire system 415 /440 volts grade including complete internal wiring with not less than 2.5 Sqmm copper wire including cable glands and lugs of suitable sizes with suitable PCC (1:3:6) type C-2 foundation , necessary earthwork (if any) including taking down old unsv LT Panel/fidder pilar boX complete all as specified & as directed with & including the following accessories :
(25 Amn Main Gate Panel) (i) BUS-BAR & INTERNAL CONNECTIONS : The bus-bars shall be made up of 04 Nos high grade Copper with rating should be suitable as per incoming Breaker, duly insulated with 1100 Volts grade standard colour coded PVC sleeves & rigidly mounted on suitable sized "F" class insulators of non-hygroscopic, non-combustible, all internal connections from main bus-bars to switch gears etc. PROVISION FOR CABLE ENTRY : The provision for cable entry /exit shall be provided in the bottom for both incoming & out-going cables with the help of glands matching the existing/New LT cable sizes. INCOMING : (a) MCCB 4 Pole (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting, suitable for isolation, having breaking capacity 36 KA & of rating 250 to 320 A - 01 Nos. Make : L & T, Cat No : CM98403OOQOOG or techno-commercially equivalent of Legrand /Siemens.
OUTGOINGS : (a) MCCB 4 Pole (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting, suitable for isolation, having breaking capacity 25 KA & of rating 200 to 250 Amps - 01 Nos. Make : L & T, Cat No : CM90642OOPO or techno-commercially equivalent of Legrand /Siemens. (b) MCCB 4 Pole (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting, suitable for isolation, having breaking capacity 25 KA & of rating 160-200 A - 01 Nos (c) MCCB 4 Pole (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting, suitable for isolation, having breaking capacity 25 KA & of rating 80 to 100 A - 02 No. Make : L & T, Cat No : CM91712OOKOOG or techno-commercially equivalent of Legrand /Siemens. (d) MCCB 4 Pole (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting, suitable for isolation, having breaking capacity 25 KA & of rating 63 to 80 A - 02 Nos. Make : L & T, Cat No : CM91712OOJOOG or techno-commercially equivalent of Legrand /Siemens. (e) MCB SPN "C" series having breaking capacity 10 KA of rating 06 to 32 Amps - 02 No. Make : L&T/Legrand /Siemens. (f) MCB TPN "C" series having breaking capacity 10 KA of rating 40 to 63 Amps - 02 No. Make : L&T /Legrand /Siemens.
All as per item 93 here in before but cable size is 1500 mm (height) x 1200 mm (breadth) x 300 mm (depth) (minimum dimensions) with & including the following accessories: (FOL Depot & Signal Det) (i) BUS-BAR & INTERNAL CONNECTIONS : The bus-bars shall be made up of 04 Nos high grade Copper with rating should be suitable as per incoming Breaker, duly insulated with 1100 Volts grade standard colour coded PVC sleeves & rigidly mounted on suitable sized "F" class insulators of non-hygroscopic, non-combustible, all internal connections from main bus-bars to switch gears etc. PROVISION FOR CABLE ENTRY : The provision for cable entry /exit shall be provided in the bottom for both incoming & out-going cables with the help of glands matching the existing LT cable sizes. INCOMING : (a) MCCB 4 Pole (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting, suitable for isolation, having breaking capacity 25 KA & of rating 125 to 160 Amps - 01 . Make : L & T, Cat No : CM90642OOMO or techno-commercially equivalent of Legrand /Siemens. (b) Onload changeover switch, open-execution modular construction type, confirming to IS/IEC 60947-3, rated current 100 Amps, 415 Volts, 4 Pole, AC - 01 No. Make : L & T, Cat No : CO11000OOOO or techno-commercially equivalent in ABB/ Siemens.
OUTGOINGS : (a) MCCB 4 Pole (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting, suitable for isolation, having breaking capacity 25 KA & of rating 80 to 100 A - 02 No. Make : L & T, Cat No : CM91712OOKOOG or techno-commercially equivalent of Legrand /Siemens (b) MCCB 4 Pole (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting, suitable for isolation, having breaking capacity 25 KA & of rating 63 to 80 A - 02 Nos. Make : L & T, Cat No : CM91712OOJOOG or techno-commercially equivalent of Legrand /Siemens. (c) MCB TPN "C" series having breaking capacity 10 KA of rating 40 to 63 Amps - 02 No. Make : L&T/Legrand /Siemens. (d) MCB TPN "C" series having breaking capacity 10 KA of rating 06 to 32 Amps - 01 No. Make : L&T /Legrand /Siemens.
All as per item 93 here in before but cable size is 1500 mm (height) x 1200 mm (breadth) x 500 mm (depth) (minimum dimensions) with & including the following accessories: (100 KVA DG Set Panel at 25 Amn Pump House, Soud pump house) (i) BUS-BAR & INTERNAL CONNECTIONS : The bus-bars shall be made up of 04 Nos high grade Copper with rating should be suitable as per incoming Breaker, duly insulated with 1100 Volts grade standard colour coded PVC sleeves & rigidly mounted on suitable sized "F" class insulators of non-hygroscopic, non-combustible, all internal connections from main bus-bars to switch gears etc. PROVISION FOR CABLE ENTRY : The provision for cable entry /exit shall be provided in the bottom for both incoming & out-going cables with the help of glands matching the existing LT cable sizes. INCOMING : (a)MCCB 4 Pole (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting, suitable for isolation, having breaking capacity 25 KA & of rating 160-200 A - 01 Nos. Make : L & T, Cat No : CM90642OONO or techno-commercially equivalent of Legrand /Siemens (b) Onload changeover switch, open-execution modular construction type, confirming to IS/IEC 60947-3, rated current 160 Amps, 415 Volts, 4 Pole, AC - 01 No. Make : L & T, Cat No : CO21600OOOO or techno-commercially equivalent in ABB/ Siemens.
OUTGOINGS : (a) MCCB 4 Pole (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting, suitable for isolation, having breaking capacity 25 KA & of rating 125 to 160 Amps - 01 . Make : L & T, Cat No : CM90642OOMO or techno-commercially equivalent of Legrand /Siemens. (b) MCCB 4 Pole (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting, suitable for isolation, having breaking capacity 25 KA & of rating 80 to 100 A - 02 No. Make : L & T, Cat No : CM91712OOKOOG or techno-commercially equivalent of Legrand /Siemens. (c) MCCB 4 Pole (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting, suitable for isolation, having breaking capacity 25 KA & of rating 63 to 80 A - 01 Nos. Make : L & T, Cat No : CM91712OOJOOG or techno-commercially equivalent of Legrand /Siemens. (d) MCB TPN "C" series having breaking capacity 10 KA of rating 63 Amps - 02 No. Make : L&T /Legrand /Siemens.
All as per item 93 here in before but cable size is 1500 mm (height) x 1200 mm (breadth) x 300 mm (depth) (minimum dimensions) with & including the following accessories:- (25 Amn Gate SS No-01 & Methadi Pump House X-mer Panel, MES Colony RO Room panel ) (i) BUS-BAR & INTERNAL CONNECTIONS : The bus-bars shall be made up of 04 Nos high grade Copper with rating should be suitable as per incoming Breaker, duly insulated with 1100 Volts grade standard colour coded PVC sleeves & rigidly mounted on suitable sized "F" class insulators of non-hygroscopic, non-combustible, all internal connections from main bus-bars to switch gears etc. PROVISION FOR CABLE ENTRY : The provision for cable entry/exit shall be provided in the bottom for both incoming & out-going cables with the help of glands matching the existing LT cable sizes. INCOMING : (a) MCCB 4 Pole (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting, suitable for isolation, having breaking capacity 25 KA & of rating 160-200 A - 01 Nos. Make : L & T, Cat No : CM90642OONO or techno-commercially equivalent of Legrand /Siemens.
OUTGOINGS : (a) MCCB 4 Pole (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting, suitable for isolation, having breaking capacity 25 KA & of rating 125 to 160 Amps - 02 . Make : L & T, Cat No : CM90642OOMO or techno-commercially equivalent of Legrand /Siemens. (b) MCCB 4 Pole (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting, suitable for isolation, having breaking capacity 25 KA & of rating 80 to 100 A - 02 No. Make : L & T, Cat No : CM91712OOKOOG or techno-commercially equivalent of Legrand /Siemens. (c) MCCB 4 Pole (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting, suitable for isolation, having breaking capacity 25 KA & of rating 63 to 80 A - 01 Nos. Make : L & T, Cat No : CM91712OOJOOG or techno-commercially equivalent of Legrand /Siemens. (d) MCB TPN "C" series having breaking capacity 10 KA of rating 63 Amps - 03 No. Make : L&T /Legrand /Siemens.
All as per item 93 here in before but cable size is 1800 mm (height) x 1800 mm (breadth) x 500 mm (depth) (minimum dimensions) with & including the following accessories:- (MES Colony Pump Panel & Methadi Pump House Pump Panel ) (i) BUS-BAR & INTERNAL CONNECTIONS : The bus-bars shall be made up of 04 Nos high grade Copper with rating should be suitable as per incoming Breaker, duly insulated with 1100 Volts grade standard colour coded PVC sleeves & rigidly mounted on suitable sized "F" class insulators of non-hygroscopic, non-combustible, all internal connections from main bus-bars to switch gears etc. PROVISION FOR CABLE ENTRY : The provision for cable entry /exit shall be provided in the bottom for both incoming & out-going cables with the help of glands matching the existing LT cable sizes. INCOMING : (a) MCCB 4 Pole (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting, suitable for isolation, having breaking capacity 25 KA & of rating 160-200 A - 01 Nos
OUTGOINGS : (a) MCCB 4 Pole (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting, suitable for isolation, having breaking capacity 25 KA & of rating 125 to 160 Amps - 02 . Make : L & T, Cat No : CM90642OOMO or techno-commercially equivalent of Legrand /Siemens. (b) MCCB 4 Pole (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting, suitable for isolation, having breaking capacity 25 KA & of rating 80 to 100 A - 02 No. Make : L & T, Cat No : CM91712OOKOOG or techno-commercially equivalent of Legrand /Siemens. (c) Smart controller with in built short circuit protection ( In built MCB with K-Curve & MCCB,Voltage and current based protection for all faults with in built hour based and real time clock based timer, in built multi function meter for measuring voltage, current, power factor and power consumption suitable for Pump/ motor 3-phase,415 V, 50 HZ for 40HP Motor. Make- L&T Cat No. CS91652LNTO-01No or techno-commercially equivalent of Legrand /ABB/Siemens. (d) Smart controller with in built short circuit protection ( In built MCB with K-Curve & MCCB,Voltage and current based protection for all faults with in built hour based and real time clock based timer, in built multi function meter for measuring voltage, current, power factor and power consumption suitable for Pump/ motor 3-phase,415 V, 50 HZ for 20HP Motor. Make- L&T Cat No. CS91532DNFO-01No or techno-commercially equivalent of Legrand /ABB/Siemens. (e) MCB TPN "C" series having breaking capacity 10 KA of rating 06 to 32 Amps - 02 No. Make : L&T/Legrand /Siemens. (f) MCB TPN "C" series having breaking capacity 10 KA of rating 40 to 63 Amps - 02 No. Make : L&T /Legrand /Siemens.
All as per item 93 here in before but cable size is 1200 mm (height) x 1200 mm (breadth) x 300 mm (depth) (minimum dimensions) with & including the following accessories:- (Engr park-02 & Jalal Khan Well,Tatra, MES Colony Shallow well) (i) BUS-BAR & INTERNAL CONNECTIONS : The bus-bars shall be made up of 04 Nos high grade Copper with rating should be suitable as per incoming Breaker, duly insulated with 1100 Volts grade standard colour coded PVC sleeves & rigidly mounted on suitable sized "F" class insulators of non-hygroscopic, non-combustible, all internal connections from main bus-bars to switch gears etc. PROVISION FOR CABLE ENTRY : The provision for cable entry /exit shall be provided in the bottom for both incoming & out-going cables with the help of glands matching the existing LT cable sizes. INCOMING : (a) MCCB 4 Pole (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting, suitable for isolation, having breaking capacity 25 KA & of rating 125 to 160 Amps - 01 . Make : L & T, Cat No : CM90642OOMO or techno-commercially equivalent of Legrand /Siemens.
OUTGOINGS : (a) MCCB 4 Pole (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting, suitable for isolation, having breaking capacity 25 KA & of rating 63 to 80 A - 03 Nos. Make : L & T, Cat No : CM91712OOJOOG or techno-commercially equivalent of Legrand /Siemens. (d) MCB TPN "C" series having breaking capacity 10 KA of rating 06 to 32 Amps - 02 No. Make : L&T/Legrand /Siemens. (e) MCB TPN "C" series having breaking capacity 10 KA of rating 40 to 63 Amps - 02 No. Make : L&T /Legrand /Siemens.
Notes for Item Nos 93.00 to 98.03:- (i) Design / drawing / BOM of the Panel Board showing the dimensions is to be obtained from the Manufacturer / Supplier & is to be got approved from the Engr-in-Charge & GE before placing final order to the manufacturer. (ii) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates. (iii)- Make of Panel :- M/s Bafna Electric Company / M/s Shreeji Enterprises Pratap Nagar (Jodhpur)/ Osian / M/s Ustav Electricals Pvt. Ltd. Jodhpur
M&L for shifting the existing panel/Changeover boxes alongwith MC Channel ang angle iron frame, to a place directed by Engr-in-Charge incl making suitable fixing arrangement and isolating the existing cables properly incl making connections of Cables at New Location with suitable Lugs and Glands complete all as specified and directed. The Rate Quoted by contractor is deemed to be inclusive of transportation cost of panel from existing location to New location with in Same military station. Note : The quoted rate is deemed to be inclusive of transportation and other misc charges
Note:- Qty's are clubbed for 2 Nos CPP Job. Qty's details for item No. 9.00 to 13.00, 16.00 to 20.00, 30.00 to 32.00 & 37.00 details as per Annexure-I on Sl. Pg. No. 58 of Tender Document. Rest all items qty's as below mentioned:- (i)- CPP Sl. No. 18 of Jasai Mil Stn:- All qty's for item No. 1.00 to 90.00 excluding items mentioned above Note. (ii)- CPP Sl. No. 19 of Jasai Mil Stn:- All qty's for item No. 90.00 to 99.00.
National Rewinding Works (BID ID -3461642)
DEVARAM CONSTRUCTION COMPANY (BID ID -3457809)
Devi Engineeing (BID ID -3465600)
Rasam Engg Co. (BID ID -3457901)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.50 MB
BOQ_821380.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .