| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹75.2 LAccepted-AOC | L1 | Accepted-AOC LOWEST QUOTED HENCE ADMITTED | |
| 2 | L2₹76.3 L+₹1.1 L (1.41%)Rejected-AOC NO 49 MSN NILAYAM 3RD CROSS HILL VIEW GARDEN TUNAHALLI SUBRAMANYAPURA POST BANGALORE 560061 | BANGALORE | BANGALORE | KARNATAKA | 560061 | L2 | Rejected-AOC NOT LOWEST QUOTED HENCE NOT ADMITTED | |
| 3 | L3₹79.9 L+₹4.6 L (6.17%)Rejected-AOC 6 A FIRST MAIN NEAR JAMIYA MASJID ISLAMPUR ANNASANDRAPALAYA HAL VIMANAPURA POST BANGALORE 560 017 | BANGALORE | BENGALURU URBAN | KARNATAKA | 560017 | L3 | Rejected-AOC NOT LOWEST QUOTED HENCE NOT ADMITTED | |
| 4 | L4₹81.5 L+₹6.3 L (8.38%)Rejected-AOC SITE NO 29 30 1ST CROSS NAGAPPA REDDY LAYOUT KAGGADASAPURA CV RAMAN NAGAR PO BANGALORE 560 093 | BANGALORE | BANGALORE | KARNATAKA | 560093 | L4 | Rejected-AOC NOT LOWEST QUOTED HENCE NOT ADMITTED | |
| 5 | L5₹82.0 L+₹6.7 L (8.92%)Rejected-AOC | L5 | Rejected-AOC NOT LOWEST QUOTED HENCE NOT ADMITTED |
Tender Value
Refer Docs
EMD Value
₹1.5 L
Closing Date
31 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
COL MANOJ NEGI
CWE AF North Bangalore Bellary Road JC Nagar Post Bangalore 560006
IMPROVEMENT TO BUILDING NO P-393/2 AT 26ED AF UNDER GE (AF) MARATHAHALLI
2023_MES_633666_1
87535CWEAFNMAR
Open Tender
Civil Works
Item Rate
240 days
GE (AF) MARATHAHALLI
AS PER NIT
7 documents required · 7 mandatory
₹1,000
GE (AF) MARATHAHALLI
₹1.5 L
Yes
23 Feb 2024
20 Dec 2023
7 Feb 2024
20 Dec 2023
31 Jan 2024
24 Jan 2024
21 Dec 2023 - 1 Jan 2024
Amount
Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness (below or above GL) complete all as specified and directed.
Taking down PVC pipes of 150mm dia (pipes for valley gutter) complete all as specified and directed.
Dismantling of Plain or corrugated galvalume/ carbonate sheet in roof covering /steel sheeting of any guage fixed on valley gutters including securing MS flat and screws etc complete all as specified and directed.
Taking down cement plaster on brick work or stone wall etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
M& L for rendering 10mm thick cement plaster in CM 1:6 on fair faces of brick work or concrete surfaces including finished even and smooth complete all as specified and directed.
M& L for rendering 15mm thick cement plaster in CM 1:4 on fair faces of brick work on concrete surfaces including finished even and smooth using water proofing compound complete all as specified and directed. Note: Supply of water proofing compound shall be measured and paid seperately
Supply only integral waterproofing compound.
M& L for preparation of new decorated plastered surfaces of walls and applying three coats of white wash complete all as specified and directed.
M& L for preparing new plastered surfaces of walls and applying two coats of cement base paint complete all as specified and directed.
S & F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls of bore 150mm (pipes for valley gutter) complete all as specified and directed.
Removing building materials etc, (other than spoil) to a distance of 10 km or above, beyond the lead included in the rates, including loading, unloading and stacking at the destination complete all as specified and directed.
S & F pre-painted galvalume sheet sandwiched with PUF sheet of 50mm thickness and bottom of plain galvalume sheet, Prepainted galvalume sheel shall be aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa sandwiched with PUF sheet of 50mm thickness and bottom of plain Galvalume sheet as in roof covering/ridges cladding to wall, fixed with self tapping screws complete all as specified and directed.
S & F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/ridges cladding to wall, fixed with self tapping screws complete all as specified and directed.
M & L for PCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in roof kerbs / PCC gola etc complete all as specified and directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. and brushing neat cement slurry with 3.0 kg of cement per sqm complete all as specified and directed.
M & L for preparation of old steel surface and applying one coat of aluminium paint on steel surfaces complete all as specified and directed.
S&F plain galvanised mild steel sheeting 2 mm thick in ridges hips valley gutters, drip and straight flashing (length and girth as fixed) with grade of zinc coating 275. including welded or soldered joints and mouth pieces of rain water pipe etc complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips complete all as specified and directed.
M&L 4 mm thick sheet glass ordinary quality and glazing with oil putty in square n.exc. 0.5 Sqm in each pane complete all as specified and directed.
M&L 5.5 mm thick sheet glass ordinary quality and glazing with oil putty in square exc. 0.5 Sqm in each pane complete all as specified and directed.
M & L for preparation of old decorated wall surfaces including brooming down or steel wire brushing, scraping down smoke soot, module, moss and efflorescence salt, oil and greasy spots etc and applying two coats of white wash on wall complete all as specified and directed.
M & L for preparation of old decorated wall surfaces including brooming down or steel wire brushing, scraping down smokes soot, module, moss and effloroscent salts, oil and greasy spots and applying one coat of cement based paint on walls complete all as specified and directed.
M&L for preparation of old decorated surfaces of walls including washing, rubbing down and stopping of distempered surfaces and applying one coat of oil bound distemper complete all as specified and directed.
M&L for preparing old treated wooden surface over 10 cm width or girth with a filler coat of thin varnish or lacquer or shellac varnish and finishing coat with synthetic varnish complete all as specified and directed.
S&F mild steel works in Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed.
M&L two coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces over 10cm width or girth after preparation of new surfaces complete all as specified and directed.
S&F in repair stainless steel self contained wind power design industrial turbo ventilator 60cm dia including ball bearing etc complete all as specified and directed.
M&L powder coated anodized aluminium frame for doors, windows, ventilators with one or more rebates including jointing cleat for fixing etc. in repairs complete all as specified and directed.
M&L for 12mm thick particle board, extension grade, medium density, flat pressed, single layer type or three layer type with BWR type adhesive, fixed with screws to aluminium frame work complete all as specified and directed.
M & L in repairs anodized aluminium snap grid frame work for false ceiling including provn of hangers 6 mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3 mm size 60 mm long and expansion hold fasteners 12.5 mm dia 40 mm long complete all as specified and directed.
M & L 12mm thick perforated particle board/ tiles for insulation & accoustic purposes, 60X60cm in size, fixed with nails to timber frame work or with staples on snap grid complete all as specified and directed.
S&F for ball bearing for rolling shutters in repairs complete all as specified and directed.
S & F rolled mild steel Fe-410-W(Gde- E-250) quality- B in plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment for ramp to withstand 5 ton bearing load capacity of vehicle complete all as specified and directed.
S & F 3mm thick Fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc complete all as specified and directed.
S&F for Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates conforming to Fe 410 - W (Grade - 250) quality 'A'
M&L for 75mm thick cement concrete type B-2, 1:2:4 (using 40mm graded stone aggregate) as in flooring finished even and fair without using extra cement complete all as specified and directed.
M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed bed laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including 20mm thick screed bed layer in CM 1:6 including rubbing and polishing by machine including treating the surface with beeswax polish complete all as specified and directed.
Taking down sliding door shutter of size exc. 7 sqm and n. exc. 9 sqm each shutter and refixing in position after cleaning of sliding path and necessary greasing complete all as specified and directed.
Taking down old point wiring for light/ fan/ 5A/15A switch socket complete with switches/ switch sockets/ ceiling roses/ resistance type fan regulator/ light fitting etc including with all accessories complete all as specified and directed.
Taking down submain wiring of any size and making good the disturbed surface of wall, floors, ceiling etc complete all as specified and directed.
Taking down ceiling fan / Exhaust fan, sealing cable end dismantling the fan blade to be kept in safe custody complete all as specified and directed.
Taking down unserviceble MCB DB, SPN, TPN with MCBs Main switch any rating complete all as specified and directed.
Point wiring with cable of FRLS copper multistranded conductor 2.5 sqmm 1100 volts grade drawn through in PVC conduit with all accessories fixing arrangements and all conduit accessories in concealed wiring fixed on ceiling / fixed to roof/ truss /columns etc including provision of branded modular inner and outer modular plate with frame and PVC surface type box of suitable size conceiled in wall, surface for housing switches / sockets / regulators etc with 2.5 sqmm PVC insulated multistranded copper earth continuity conductor connecting to common earth dolly for one light point controlled by one switch 5/6 amps complete all as specified and directed. Note:- Conduit pipes shall run on surface wall where ever its required.
All as per item No 44 here in before but for one ceiling fan/ exhaust fan point controlled by one switch and a regulator.
All as per item No 44 here in before but for one 5 amps socket point on independent board.
All as per item No 44 here in before but for one 5 amps socket point on the same board with other switches.
Point wiring with cable of FRLS copper multistranded conductor 2.5 sqmm 1100 volts grade drawn through in PVC conduit with all accessories fixing arrangements and all conduit accessories in concealed wiring fixed on ceiling / fixed to roof/ truss /columns etc including provision of branded modular inner and outer modular plate with frame and PVC surface type box of suitable size conceiled in wall, surface for housing switches / sockets / regulators etc with 2.5 sqmm PVC insulated multistranded copper earth continuity conductor connecting to common earth dolly for power points 15 amps complete all as specified and directed. Note:- Conduit pipes shall run on surface wall where ever its required.
S&F Switch modular type single pole and one way 230 volts 5/ 6 Amps complete all as specified and directed.
S&F bakelite ceiling rose two to three plate surface and jumpo type complete all as specified and directed.
S&F socket out let 3 /5 Pin, 5 / 6A modular type single pole and one way 230 volts 5 Amps complete all as specified and directed.
S&F switch modular type 16A modular type single pole and one way 230 volts complete all as specified and directed.
S&F socket out let 3/5 Pin, 15 /1 6A modular type single pole and one way 230 volts complete all as specified and directed.
S&F for sub main wiring complete with two runs of 1.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including PVC rigid conduit of 20mm dia alongwith accessories on surface of wall, roofs etc., complete all as specified and directed.Note : 2 runs of PVC FRLS cable, one run of earth continuity conductor cable and one run of PVC conduit shall be measured as one length/running metre.
S&F sub main wiring complete with two runs of 2.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 2.5 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including PVC rigid conuit of 20 mm dia alongwith accessories on surface of wall , roofs etc., all as specified and as directed. NOTE :- 2 runs of PVC FRLS cable, one run of earth continuity conductor cable and one run of PVC conduit shall be measured as one length/ running metre.
S&F sub main wiring complete with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including PVC rigid conduit of 20 mm dia alongwith accessories on surface of wall, roofs etc., complete all as specified and directed. NOTE :- 2 runs of PVC FRLS cable, one run of earth continuity conductor cable and one run of PVC conduit shall be measured as one length/ running metre.
S&F sub main wiring complete with two runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 6 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including PVC rigid conuit of 20 mm dia alongwith accessories on surface of wall , roofs etc., all as specified and as directed. NOTE :- 2 runs of PVC FRLS cable, one run of earth continuity conductor cable and one run of PVC conduit shall be measured as one length/running metre.
S&F sub main wiring complete with four runs 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 6 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including PVC rigid codnuit of 25 mm dia alongwith accessories on surface of wall , roofs etc., complete all as specified and directed. Note :- 4 runs of PVC FRLS cable, one run of earth continuity conductor cable and one run of PVC conduit shall be measured as one length/ running metre.
S&F in repairs LED light fitting 2 x 20 W, surface mounted, industrial box type luminaire with CRCA body, pre-coated in white and pre-wired for LED tube, bipin holders, connector block etc., including 20W - 2 Nos LED T8 tubular lamp with in built driver with all accessories and connecting up with 3 core 0.5sqmm copper wire between ceiling rose and fitting terminal complete all as specified and directed. Make :Crompton/ Bajaj/ Havells
S&F 36 W LED, high efficacy 2 x 2 recess LED flat panel with high brightness LED for glare free homogenous illumination including LED driver complete all as specifiedand directed. Make : Crompton/ Bajaj/ Havells
S&F double stiff pendent, comprising of galvanised steel or chromium plated brass bell mouth connectors 02 Nos with back plate and 2x1.5 m long paralleled 20mm dia galvanised or stove enamelled screwed steel conduit with two check nuts for fixing tube light fitting and 1.5 m long twin core 0.5 Sqmm copper conductor flexible wire complete all as specified and directed.
Material and labour for additional length for adjustment of conduit and flexible wire above length mentioned in item No. 61 above complete all as specified and directed.
Material and labour for deduction of length for adjustment of conduit and flexible wire above length mentioned in item No. 61 above complete all as specified and directed.
S&F MCCB DB TPN 4 way (Vertical), double door, 415 V, AC, 50 Hz, IP-43 protection conforming to IS-13032 universal mounting with copper bus bar, neutral link, earth link, earthing studs, detachable gland plates with knock outs on both sides complete all as specified and directed.
S&F sheet metal enclosure MCB DB SPN 8 way double door type with suitable bus bar complete. Note :- (i) MCB TP / SP as required will be measured & paid separately in relevant item. (ii) Rate deemed to be inclusive of connecting the cables with incoming /outgoing MCCB/ MCBs with suitable lugs and cable gland complete all as specified and directed.
S&F sheet metal enclosure MCB DB SPN 4 way double door type with suitable bus bar complete. Note :- (i) MCB TPN as required will be measured & paid separately in relevant item. (ii) Rate deemed to be inclusive of connecting the cables with incoming/ outgoing MCCB/ MCBs with suitable lugs and cable gland complete all as specified and directed.
S&F Triple pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole MCB of cap 32 Amps complete all as specified and directed.
S&F MCB SP 6 to 32 Amps, 10KA, breaking capacity, 240Volts, 50 Hz AC supply complete all as specified and directed.
S&F MCB SPN 6 to 32 Amps, 10KA, breaking capacity, 240Volts, 50 Hz AC supply complete all as specified and directed.
S&F MCB TPN 63 Amps rating 'C' series 10KA, breaking capacity, 415 Volts, 50 Hz AC complete all as specified and directed. Make;-Havells/ Legrand/ Standard/ L&T
S&F MCCB, 4 pole, 100 Amps, 25 KA, breaking capacity, 415 volts, 50Hz complete all as specified and directed.
M&L for servicing, painting of ceiling fan / exhaust fan complete in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc complete all as specified and directed.
S&F Entry / Exit display board, 3w single side display with 2 hours battery back up complete all as specified and directed. Make: Bajaj or equivalent to the makes specified in list of manufacturer here in after.
S&F ceiling fan complete with blades, down rods, electronic regulator and accessories, 230 V, 1200mm sweep, Min air delivery 210 CFM with service value 6.00 BEE, five star rated complete all as specified and directed.
S&F exhaust fan, steel body AC single phase, 230V of size 380mm sweep with blades, frame and louvers complete all as specified and directed.
Taking down carefully 30 cm long air termination rods with base plates and aluminium roof conductor including FRP insulators, after unscrewing nuts and bolts with washers, keeping in safe custody and M&L for proper refixing the same with aluminium conductor with new epoxy insulators for one metre on the roof sheets and on wall complete all as specified and directed by Eng - in -Charge Note: The items shall be reused after repair work completed.
S&F aluminium strip 25 x 3.15mm with saddles and fixing screws etc, for roof conductors and down conductors above ground complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 600X600X6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level connected to GI 32x6mm strip through 40 mm GI pipe as earthing lead protection and 20mm GI pipe is connected water pouring funnel up to earth plate as earthing lead means of nuts, bolts, check nuts and washer of GI steel and connecting to testing point including provision of test point and all as shown in electrical plate No. 3 of SSR Pt I. The work is inclusive of necessary earth work and PCC chamber in type C1 (1:2:4) with 8mm CTD bar reinforcement both ways at 140 mm bent to centre complete all as specified and directed. (for lightning arrester) Note:- GI earth strip beyond 7.5m shall be measured and paid separately
M&L for earthing complete with galvanized steel earth plate electrode 600X600X6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level connected to 4.0 mm GI wire through 40 mm GI pipe as earthing lead protection and 20mm GI pipe is connected water pouring funnel up to earth plate means of nuts, bolts, check nuts and washer of GI steel and connecting to testing point including provision of test point and all as shown in electrical plate No. 3 of SSR Pt I. The work is inclusive of necessary earth work and PCC chamber in type C1 (1:2:4) with 8mm CTD bar reinforcement both ways at 140 mm bent to centre complete all as specified and directed by Engr-in-Charge. Note:- GI earth wire beyond 7.5m shall be measured and paid separately
M&L for maintenance free earthing, each pit consisting of copper coated steel rod of size 17.2mm dia 3 mtrs long 250 Microns molecularly bonded, joined with connecting clamps filled with maintenance free earth enhancing compounds curec+ 6 kgs & curecon 10 kgs, compounds strictly be eco friendly and must comply to IEEE 80:2000 clause 14.5 (d), IEEE 80:2000 clause 14.5 (b) and this compound should be electrically & thermally conducive, must be tested for long term in CPRI for at least 2 year to display its stability & compound must be ISO certified and the earth pit should be closed with high density polymer HDPE inspection pit of 308 X 308 X 214 mm depth complete all as specified and directed. Note: (i) Earth pit is required to be identified by the specific marker, colour codes (a) Maint free earthing pits- Red colour and write proper earthing details all as directed by Engr-in-charge. (ii) The ring main earth resistance value shall be 1.0 Ohms. (iii) Rate deemed to be inclusive of one PCC inspection chamber of size 30cm x 30 cm x 30 cm depth and CI cover placed on main pit. (iv) 25 mm x 5 mm x 300 mm copper bus bar - 1 No. (v) 25 mm x 25 mm x 150 mm bus bar - 1No (vi) Earth conductor beyond 7.5m shall be measured and paid separately under relevant items of this schedule.
M&L for test point terminal block made of gun metal or phosphoros bronze size 75 x 75 x 25mm drilled and screwed including 3 Nos 8 mm dia 25mm long hexagonal head screw including suitable enclosure complete all as specified and directed.
M&L for cutting chases in brick walls for concealed conduit wiring, not exc 10 cm girth, pinning in making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and making good complete all as specified and directed.
M&L for G.I. tubing light grade of size 50mm bore for protection of cables to be laid under roads, crossings/culverts including taking down/up old unserviceable GI tubing complete all as specified and directed.
PRAGATHI BUILDERS
MAA ENGINEERING SERVICERS
B5BUILDING SOLUTIONS
J R CONSTRUCTIONS
G K CONSTRUCTIONS
Shanthi Construction
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .