Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 CrAccepted-AOC C 9 KUMAR ELIXIR BANER ROAD BANER PUNE MAHARASHTRA 411045 | PUNE | MAHARASHTRA | 411045 | ₹2.0 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹2.3 Cr+₹28.2 L (14.3%)Rejected-AOC | ₹2.3 Cr+₹28.2 L (14.3%) | L2 | Rejected-AOC L2 |
| 3 | Rejected-Technical 8 BECK BAGAN ROW SUCCESS CENTRE 8 BECK BAGAN ROW BECK BAGAN KOLKATA WEST BENGAL 700017 | KOLKATA | WEST BENGAL | 700017 | - | - | Rejected-Technical Terms not fulfill |
Tender Value
Refer Docs
Closing Date
8 Dec 2023, 5:00 pmClosed
DMO
Collector office chandrapur
D3_BMS/01-2023
2023_CHDPR_957403_1
D3_BMS/01-2023
Open Tender
Civil Works - Others
Item Rate
84 days
Chandrapur Cancer Care Foundation, New Government
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
Exempted
Chandrapur Cancer Care Foundation, New Government
5 Mar 2024
26 Oct 2023
22 Dec 2023
26 Oct 2023
8 Dec 2023
26 Oct 2023
1 Nov 2023
Amount
D3-BMS BOQ
BMS Machine: Intel Quad Core processor (Latest Technology), Windows® 2010 SP2 or above operating System, 1 TB HDD, 8 GB RAM, Enhanced graphic Card, DVD Combo Drive, Ethernet Port with 32" color monitor flat screen LED display, multimedia keyboard & optical mouse and microsoft office 2013 and anti virus as per Specification.
A4 B/W laser Printer
Software: Supplying, Installing, Testing & Commissioning of following Web Based Graphical interface software. The system should be accessible from anywhere on LAN or WAN or Ethernet without additional licenses. The Communication protocol shall be one of the Industry Standard Open Protocols such as BACNet, LON etc. System should be scalable and software should be integrable with Access Control, CCTV VMS seamlessly to generate a holistic view. Software shall have 3 simultaneous user license.Note: The offered software has to support a min of 4000 data points or the data points required by this project whichever is higher.
Third Party Integartion: Supplying, Installing, Testing & Commissioning of following UL & BTL listed Gateway/ Open Protocol Software for integrating the foll third party system communicating on one of the Standard Open Protocols such as BACNet, MODBUS, M-Bus, J Bus etc - Vendor to consider required No. of Integrators for qty's mentioned in IO summary. Integrator/ Gateway/ supervisory controller shall be of the same OEM as field controllers & software. Integration of following services should be considered: Chillers AHU, Pump VFDs DG Sets Access Control system CCTV System Fire Alarm & Detection System Lift/ Elevators UPS MFM/KWH Meters
IP Based Controllers with I/O modules etc as per I/O summary. The controller shall be UL/BTL Listed capable of networked operations to exchange data with other controllers and workstations. The DDC Controllers shall be web enabled, RAM of min 3 GB and Processor speed of min. 1.2 Ghz. DDC controller shall have battery backup for atleast 10 days.All DDC Controllers shall be provided with hinged doors with locking facility. Apart from the controllers, the enclosers shall house the terminal blocks, load relays and associaetd equipment. The internal wiring in the enclosure shall be factory wired. The packaging shall be such that complete installation of the field equipment and field wiring can be done prior to the installation of the electronics. The controller shall be independent in operation and the failure of any other device / controller or the operator workstations, shall not cause any disruption to the function of the rest of the system. The DDC controllers shall have the facility to implement user modifiable time schedules as daily, weekly, monthly annual temporary schedules. The DDC controllers would 'reboot' automatically on resumption of power. Controllers shall not require manual intervention for the reboot of the controller software. The DDC Controllers Shall have integration facility with atleast 2 ports of integration.note - should have suitable volt power provision for HVAC field device like- PICV, mbfv, modulatining bfv, othe bms field device DDC for Chiller plant
IP Based Controllers with I/O modules etc as per I/O summary. The controller shall be UL/BTL Listed capable of networked operations to exchange data with other controllers and workstations. The DDC Controllers shall be web enabled, RAM of min 3 GB and Processor speed of min. 1.2 Ghz. DDC controller shall have battery backup for atleast 10 days.All DDC Controllers shall be provided with hinged doors with locking facility. Apart from the controllers, the enclosers shall house the terminal blocks, load relays and associaetd equipment. The internal wiring in the enclosure shall be factory wired. The packaging shall be such that complete installation of the field equipment and field wiring can be done prior to the installation of the electronics. The controller shall be independent in operation and the failure of any other device / controller or the operator workstations, shall not cause any disruption to the function of the rest of the system. The DDC controllers shall have the facility to implement user modifiable time schedules as daily, weekly, monthly annual temporary schedules. The DDC controllers would 'reboot' automatically on resumption of power. Controllers shall not require manual intervention for the reboot of the controller software. The DDC Controllers Shall have integration facility with atleast 2 ports of integration.note - should have suitable volt power provision for HVAC field device like- PICV, mbfv, modulatining bfv, othe bms field device DDC for Air Handling Units (FM, CS) (2 Units/DDC Panel)
IP Based Controllers with I/O modules etc as per I/O summary. The controller shall be UL/BTL Listed capable of networked operations to exchange data with other controllers and workstations. The DDC Controllers shall be web enabled, RAM of min 3 GB and Processor speed of min. 1.2 Ghz. DDC controller shall have battery backup for atleast 10 days.All DDC Controllers shall be provided with hinged doors with locking facility. Apart from the controllers, the enclosers shall house the terminal blocks, load relays and associaetd equipment. The internal wiring in the enclosure shall be factory wired. The packaging shall be such that complete installation of the field equipment and field wiring can be done prior to the installation of the electronics. The controller shall be independent in operation and the failure of any other device / controller or the operator workstations, shall not cause any disruption to the function of the rest of the system. The DDC controllers shall have the facility to implement user modifiable time schedules as daily, weekly, monthly annual temporary schedules. The DDC controllers would 'reboot' automatically on resumption of power. Controllers shall not require manual intervention for the reboot of the controller software. The DDC Controllers Shall have integration facility with atleast 2 ports of integration.note - should have suitable volt power provision for HVAC field device like- PICV, mbfv, modulatining bfv, othe bms field device DDC for FCUs (2 units/DDC Panel)
IP Based Controllers with I/O modules etc as per I/O summary. The controller shall be UL/BTL Listed capable of networked operations to exchange data with other controllers and workstations. The DDC Controllers shall be web enabled, RAM of min 3 GB and Processor speed of min. 1.2 Ghz. DDC controller shall have battery backup for atleast 10 days.All DDC Controllers shall be provided with hinged doors with locking facility. Apart from the controllers, the enclosers shall house the terminal blocks, load relays and associaetd equipment. The internal wiring in the enclosure shall be factory wired. The packaging shall be such that complete installation of the field equipment and field wiring can be done prior to the installation of the electronics. The controller shall be independent in operation and the failure of any other device / controller or the operator workstations, shall not cause any disruption to the function of the rest of the system. The DDC controllers shall have the facility to implement user modifiable time schedules as daily, weekly, monthly annual temporary schedules. The DDC controllers would 'reboot' automatically on resumption of power. Controllers shall not require manual intervention for the reboot of the controller software. The DDC Controllers Shall have integration facility with atleast 2 ports of integration.note - should have suitable volt power provision for HVAC field device like- PICV, mbfv, modulatining bfv, othe bms field device DDC for Treated Fresh Air Units (2 Units/DDC Panel)
IP Based Controllers with I/O modules etc as per I/O summary. The controller shall be UL/BTL Listed capable of networked operations to exchange data with other controllers and workstations. The DDC Controllers shall be web enabled, RAM of min 3 GB and Processor speed of min. 1.2 Ghz. DDC controller shall have battery backup for atleast 10 days.All DDC Controllers shall be provided with hinged doors with locking facility. Apart from the controllers, the enclosers shall house the terminal blocks, load relays and associaetd equipment. The internal wiring in the enclosure shall be factory wired. The packaging shall be such that complete installation of the field equipment and field wiring can be done prior to the installation of the electronics. The controller shall be independent in operation and the failure of any other device / controller or the operator workstations, shall not cause any disruption to the function of the rest of the system. The DDC controllers shall have the facility to implement user modifiable time schedules as daily, weekly, monthly annual temporary schedules. The DDC controllers would 'reboot' automatically on resumption of power. Controllers shall not require manual intervention for the reboot of the controller software. The DDC Controllers Shall have integration facility with atleast 2 ports of integration.note - should have suitable volt power provision for HVAC field device like- PICV, mbfv, modulatining bfv, othe bms field device DDC for Toilet Exhaust Fans
IP Based Controllers with I/O modules etc as per I/O summary. The controller shall be UL/BTL Listed capable of networked operations to exchange data with other controllers and workstations. The DDC Controllers shall be web enabled, RAM of min 3 GB and Processor speed of min. 1.2 Ghz. DDC controller shall have battery backup for atleast 10 days.All DDC Controllers shall be provided with hinged doors with locking facility. Apart from the controllers, the enclosers shall house the terminal blocks, load relays and associaetd equipment. The internal wiring in the enclosure shall be factory wired. The packaging shall be such that complete installation of the field equipment and field wiring can be done prior to the installation of the electronics. The controller shall be independent in operation and the failure of any other device / controller or the operator workstations, shall not cause any disruption to the function of the rest of the system. The DDC controllers shall have the facility to implement user modifiable time schedules as daily, weekly, monthly annual temporary schedules. The DDC controllers would 'reboot' automatically on resumption of power. Controllers shall not require manual intervention for the reboot of the controller software. The DDC Controllers Shall have integration facility with atleast 2 ports of integration.note - should have suitable volt power provision for HVAC field device like- PICV, mbfv, modulatining bfv, othe bms field device DDC for Pressurisation Fans (4 fans/DDC Panel)
IP Based Controllers with I/O modules etc as per I/O summary. The controller shall be UL/BTL Listed capable of networked operations to exchange data with other controllers and workstations. The DDC Controllers shall be web enabled, RAM of min 3 GB and Processor speed of min. 1.2 Ghz. DDC controller shall have battery backup for atleast 10 days.All DDC Controllers shall be provided with hinged doors with locking facility. Apart from the controllers, the enclosers shall house the terminal blocks, load relays and associaetd equipment. The internal wiring in the enclosure shall be factory wired. The packaging shall be such that complete installation of the field equipment and field wiring can be done prior to the installation of the electronics. The controller shall be independent in operation and the failure of any other device / controller or the operator workstations, shall not cause any disruption to the function of the rest of the system. The DDC controllers shall have the facility to implement user modifiable time schedules as daily, weekly, monthly annual temporary schedules. The DDC controllers would 'reboot' automatically on resumption of power. Controllers shall not require manual intervention for the reboot of the controller software. The DDC Controllers Shall have integration facility with atleast 2 ports of integration.note - should have suitable volt power provision for HVAC field device like- PICV, mbfv, modulatining bfv, othe bms field device DDC for Plant room Ventilation (4 fans/DDC Panel)
IP Based Controllers with I/O modules etc as per I/O summary. The controller shall be UL/BTL Listed capable of networked operations to exchange data with other controllers and workstations. The DDC Controllers shall be web enabled, RAM of min 3 GB and Processor speed of min. 1.2 Ghz. DDC controller shall have battery backup for atleast 10 days.All DDC Controllers shall be provided with hinged doors with locking facility. Apart from the controllers, the enclosers shall house the terminal blocks, load relays and associaetd equipment. The internal wiring in the enclosure shall be factory wired. The packaging shall be such that complete installation of the field equipment and field wiring can be done prior to the installation of the electronics. The controller shall be independent in operation and the failure of any other device / controller or the operator workstations, shall not cause any disruption to the function of the rest of the system. The DDC controllers shall have the facility to implement user modifiable time schedules as daily, weekly, monthly annual temporary schedules. The DDC controllers would 'reboot' automatically on resumption of power. Controllers shall not require manual intervention for the reboot of the controller software. The DDC Controllers Shall have integration facility with atleast 2 ports of integration.note - should have suitable volt power provision for HVAC field device like- PICV, mbfv, modulatining bfv, othe bms field device DDC for Fire Fighting/ Plumbing
IP Based Controllers with I/O modules etc as per I/O summary. The controller shall be UL/BTL Listed capable of networked operations to exchange data with other controllers and workstations. The DDC Controllers shall be web enabled, RAM of min 3 GB and Processor speed of min. 1.2 Ghz. DDC controller shall have battery backup for atleast 10 days.All DDC Controllers shall be provided with hinged doors with locking facility. Apart from the controllers, the enclosers shall house the terminal blocks, load relays and associaetd equipment. The internal wiring in the enclosure shall be factory wired. The packaging shall be such that complete installation of the field equipment and field wiring can be done prior to the installation of the electronics. The controller shall be independent in operation and the failure of any other device / controller or the operator workstations, shall not cause any disruption to the function of the rest of the system. The DDC controllers shall have the facility to implement user modifiable time schedules as daily, weekly, monthly annual temporary schedules. The DDC controllers would 'reboot' automatically on resumption of power. Controllers shall not require manual intervention for the reboot of the controller software. The DDC Controllers Shall have integration facility with atleast 2 ports of integration.note - should have suitable volt power provision for HVAC field device like- PICV, mbfv, modulatining bfv, othe bms field device DDC for Smoke Extraction Fans
IP Based Controllers with I/O modules etc as per I/O summary. The controller shall be UL/BTL Listed capable of networked operations to exchange data with other controllers and workstations. The DDC Controllers shall be web enabled, RAM of min 3 GB and Processor speed of min. 1.2 Ghz. DDC controller shall have battery backup for atleast 10 days.All DDC Controllers shall be provided with hinged doors with locking facility. Apart from the controllers, the enclosers shall house the terminal blocks, load relays and associaetd equipment. The internal wiring in the enclosure shall be factory wired. The packaging shall be such that complete installation of the field equipment and field wiring can be done prior to the installation of the electronics. The controller shall be independent in operation and the failure of any other device / controller or the operator workstations, shall not cause any disruption to the function of the rest of the system. The DDC controllers shall have the facility to implement user modifiable time schedules as daily, weekly, monthly annual temporary schedules. The DDC controllers would 'reboot' automatically on resumption of power. Controllers shall not require manual intervention for the reboot of the controller software. The DDC Controllers Shall have integration facility with atleast 2 ports of integration.note - should have suitable volt power provision for HVAC field device like- PICV, mbfv, modulatining bfv, othe bms field device DDC for HT Panels
IP Based Controllers with I/O modules etc as per I/O summary. The controller shall be UL/BTL Listed capable of networked operations to exchange data with other controllers and workstations. The DDC Controllers shall be web enabled, RAM of min 3 GB and Processor speed of min. 1.2 Ghz. DDC controller shall have battery backup for atleast 10 days.All DDC Controllers shall be provided with hinged doors with locking facility. Apart from the controllers, the enclosers shall house the terminal blocks, load relays and associaetd equipment. The internal wiring in the enclosure shall be factory wired. The packaging shall be such that complete installation of the field equipment and field wiring can be done prior to the installation of the electronics. The controller shall be independent in operation and the failure of any other device / controller or the operator workstations, shall not cause any disruption to the function of the rest of the system. The DDC controllers shall have the facility to implement user modifiable time schedules as daily, weekly, monthly annual temporary schedules. The DDC controllers would 'reboot' automatically on resumption of power. Controllers shall not require manual intervention for the reboot of the controller software. The DDC Controllers Shall have integration facility with atleast 2 ports of integration.note - should have suitable volt power provision for HVAC field device like- PICV, mbfv, modulatining bfv, othe bms field device DDC for LT Panels, Transformers, DG Panels
IP Based Controllers with I/O modules etc as per I/O summary. The controller shall be UL/BTL Listed capable of networked operations to exchange data with other controllers and workstations. The DDC Controllers shall be web enabled, RAM of min 3 GB and Processor speed of min. 1.2 Ghz. DDC controller shall have battery backup for atleast 10 days.All DDC Controllers shall be provided with hinged doors with locking facility. Apart from the controllers, the enclosers shall house the terminal blocks, load relays and associaetd equipment. The internal wiring in the enclosure shall be factory wired. The packaging shall be such that complete installation of the field equipment and field wiring can be done prior to the installation of the electronics. The controller shall be independent in operation and the failure of any other device / controller or the operator workstations, shall not cause any disruption to the function of the rest of the system. The DDC controllers shall have the facility to implement user modifiable time schedules as daily, weekly, monthly annual temporary schedules. The DDC controllers would 'reboot' automatically on resumption of power. Controllers shall not require manual intervention for the reboot of the controller software. The DDC Controllers Shall have integration facility with atleast 2 ports of integration.note - should have suitable volt power provision for HVAC field device like- PICV, mbfv, modulatining bfv, othe bms field device DDC for Server room, Hub room monitoring, Field Devices
Differential Pressure transmitters for measuring pressure in Duct as per technical specification.
Differential pressure switches for indicating the Blower & Filter status in Air as per technical specification.
Differential pressure switches for pump status as per technical specification
Duct mount Temperature sensor as per technical specification
Duct mount Temperature & Humidity Sensor as per technical specification
Outside Air Temperature & Humidity Sensor as per technical specification
Duct mount CO2 sensors
Outside CO2 sensors
Wall mounted temperature + rh sensor
Immersion type temperature sensor for Chilled Water temperature
Bi-level switch for Hi-Lo level monitoring
Flameproof Level Transmitter
Water pressure Transmitter
ph sensor
TDS sensor
Current relay
Networking Devices & Accessories Supply, installation, testing and commissioning of Layer 2 unmanaged 10/100 switch. The switch shall have work with CAT6 armourded UTP cable within the building complete as per specifications and as required for BMS DDC Panel Networking. 16 Port Switch
Supply, Installation, Testing & Commissioning of 12 ports full loaded LIU Box with all the required SFP Module with accessories complete in all respect asapproved by Engineer in charge of works.
Cables & Cable Trays, 2 x 1.5 sq.mm Annealed Tinned Copper Shielded armoured cable for signal and power as per specification. (for I/O points hard wired to DDC).
Cables & Cable Trays, 4 x 1.0 sq.mm Annealed Tinned Copper Shielded armoured cable for signal and power as per specification. (for I/O points hard wired to DDC).
Cables & Cable Trays, CAT 6 A unarmoured cables with required accessories like RJ45 connector etc.
Cables & Cable Trays, 3 x 1.5 sq.mm Annealed Tinned Copper Shielded armoured cable for signal and power as per specification. (power Cable).
Cables & Cable Trays, Supply, installation, testing and commissioning of networking devices including 6 Core multimode armored OFC
1.6 mm thick GI cable tray with of the following sizes complete with angle iron supports/hanging arrangement etc. and Cable tray supports shall at every 1 meter. 300 x 50 x 2 mm
1.6 mm thick GI cable tray with of the following sizes complete with angle iron supports/hanging arrangement etc. and Cable tray supports shall at every 1 meter. 150 x 50 x 2 mm
1.6 mm thick GI cable tray with of the following sizes complete with angle iron supports/hanging arrangement etc. and Cable tray supports shall at every 1 meter. 100 x 50 x 2 mm
Magnahelic Gauges for ot and isolation room SITC,Magnahelic gauge housed in a SS304 front cover (10-0-10 Pa) complete with 300mm length pvc tubing and SS perforated nozzle for OTs / Isolation Room / Transplant Room. ( as per client requirement make list-dwyer)
PVC TRUNKING - FOR INTERIOR CONDUITS Supply and installation of PVC trunking with cover between BMS room false ceiling and BMS components. 175 mm wide
20mm dia hm frls PVC Conduit. (2 cables of 2C or 1 cables of 4C shall be limited to this conduit) Note : Cables running inside the conduit shall not be run in cable trays.
Stellar Eco Energy Solutions
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .