Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.1 LAccepted-AOC | ₹31.1 L Quoted ₹32.0 L | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹32.4 L+₹37,922 (1.19%)Rejected-Finance VILL JAMALPUR P O NAYA MAHMMADPUR DISTT BHOJPUR ARA PIN 802163 | ARA | BHOJPUR | BIHAR | 802163 | ₹32.4 L+₹37,922 (1.19%) | L2 | Rejected-Finance Other than Lowest Bidder |
| 3 | L3₹34.4 L+₹2.4 L (7.46%)Rejected-Finance NO 3 WD BUILDING JP AGARWALLA ROAD BHARALUMUKH KAMRUP ASSAM 781009 UDYAM AS 03 0009483 | KAMRUP METRO | ASSAM | 781009 | ₹34.4 L+₹2.4 L (7.46%) | L3 | Rejected-Finance Other than Lowest Bidder |
Tender Value
₹33 L
EMD Value
₹66,000
Closing Date
29 Oct 2022, 6:00 pmClosed
GE Narangi
GE Narangi C/o 99 APO
REPAIR REPLACEMENT OF UNSV LT UG CABLE AND DISTRIBUTION SYSTEM CAPACITOR BANKS APFC PANEL LT CONTROL PANEL AND OTHER ALLIED WORKS IN PH II UNDER GE NARANGI
2022_MES_555835_1
8787/B/E8
Open Tender
Civil Works
Item Rate
180 days
GE Narangi
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE Narangi
₹66,000
Yes
28 Nov 2022
3 Oct 2022
31 Oct 2022
3 Oct 2022
29 Oct 2022
16 Oct 2022
Amount
Excavation in trenches, n.exc 1.5 m wide and n.exc 1.5 m in depth for laying of cable , etc. n.exc 10 Sqm on plan and getting out in soft/loose soil complete all as specified and as directed.
Returning filling in including spreading, levelling watering and well ramming in layers not exc 25 cm thick in soft /loose soil complete all as specified and as directed.
Removing surplus soil to a distance not exc 50m and depositing at level not exc 1.5m above the starting point complete all as specified and as directed.
M&L for cutting the faulty/damaged/burnt end portion of the UG cable of cross sectional area 16 sqmm to 35 sqmm 3.5 core and making good end termination with and including suitable size of aluminium thimble/lugs duly crimped with crimping tool and refixing in existing position including insulation tape, nuts, bolts etc. as required in distribution boards/LT panel boards/ Change over switch complete all as specified and as directed.
M&L for cutting the faulty/damaged/burnt end portion of the UG cable of cross sectional area 50 sqmm 3.5 core and making good end termination with and including suitable size of aluminium thimble/lugs duly crimped with crimping tool and refixing in existing position including insulation tape, nuts, bolts etc. as required in distribution boards/LT panel boards/ Change over switch complete all as specified and as directed.
M&L for cutting the faulty/damaged/burnt end portion of the UG cable of cross sectional area 70 sqmm to 120 sqmm 3.5 core and making good end termination with and including suitable size of aluminium thimble/lugs duly crimped with crimping tool and refixing in existing position including insulation tape, nuts, bolts etc. as required in distribution boards/LT panel boards/ Change over switch complete all as specified and as directed.
M&L for cutting the faulty/damaged/burnt end portion of the UG cable of cross sectional area 240 sqmm to 300 sqmm 3.5 core and making good end termination with and including suitable size of aluminium thimble/lugs duly crimped with crimping tool and refixing in existing position including insulation tape, nuts, bolts etc. as required in distribution boards/LT panel boards/ Change over switch complete all as specified and as directed.
Taking out old unserviceable UG cable of any size/ type from trenches / wall / roof etc. for necessary repair/ replacement / re-laying works complete all as specified and as directed.
M&L for relaying old serviceable UG cable of any size/ type alongwith brick protection, sand cushioning etc as obtained from taking up/down old cable here in before in trenches/ wall/ roof etc. after necessary repair/ rerouting if directed complete all as specified and as directed.
M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 185 sqmm 3.5 core laid in trenches /floor or fixed on wall /pole including brass compression cable glands, terminal lugs etc, complete all as specified and as directed.
M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 120 sqmm 3.5 core laid in trenches /floor or fixed on wall /pole including brass compression cable glands, terminal lugs etc, complete all as specified and as directed.
M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 95 sqmm 3.5 core laid in trenches /floor or fixed on wall /pole including brass compression cable glands, terminal lugs etc, complete all as specified and as directed.
M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 50 sqmm 3.5 core laid in trenches /floor or fixed on wall /pole including brass compression cable glands, terminal lugs etc, complete all as specified and as directed.
M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 25 sqmm 3.5 core laid in trenches /floor or fixed on wall /pole including brass compression cable glands, terminal lugs etc, complete all as specified and as directed.
M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 16 sqmm 4 core laid in trenches /floor or fixed on wall /pole including brass compression cable glands, terminal lugs etc, complete all as specified and as directed.
M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with solid aluminium conductor, 1100 Volts grade of size 10 sqmm 2 core laid in trenches /floor or fixed on wall /pole including brass compression cable glands, terminal lugs etc, complete all as specified and as directed.
M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with solid aluminium conductor, 1100 Volts grade of size 6 sqmm 2 core laid in trenches /floor or fixed on wall /pole including brass compression cable glands, terminal lugs etc, complete all as specified and as directed.
Supply and spreading clean dry river sand in cable trenches as in cable cushioning complete all as specified and as directed. (Note: Punned thickness shall be measured and paid)
M&L for Sub class ‘B’ old size well burnt brick laid flat in trenches over the cable for protection of LT cable complete all as specified and as directed.
M& L for Manual boring under roads / hard standing by required T&P without disturbing the top surface of the road for passing the cable in GI Pipe of 40 mm to 80mm dia complete all as specified and as directed.
M&L for GI pipe light grade 40mm bore with all fittings laid in trenches or in floors, including taking up/ down old pipe complete all as speciffied and as directed
M&L for GI pipe light grade 80mm bore with all fittings laid in trenches or in floors, including taking up/ down old pipe complete all as speciffied and as directed
S&F in repair cable jointing kit for LT (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for aluminium Conductor cable of size 25-50 Sqmm 3.5 core complete all as specified and as directed.
S&F in repair cable jointing kit for LT (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for aluminium Conductor cable of size 70-120 Sqmm 3.5 core complete all as specified and as directed.
S&F in repair cable jointing kit for LT (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for aluminium Conductor cable of size 150-185 Sqmm 3.5 core complete all as specified and as directed.
S&F in repair cable jointing kit for LT (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for aluminium Conductor cable of size 240-300 Sqmm 3.5 core complete all as specified and as directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
M&L for cement concrete 1:3:6 type C-2 using 40 mm graded crushed stone aggregate as in foundation filling and mass concrete complete all as specified and as directed.
M & L for preparation of old painted surfaces of LT steel tubular pole 9.00 m long, cross arms, bracings, supports, clamps, back plate with nut bolts washers and providing one coat of aluminium paint including numbering and making strips in circular shape of diameter 150 mm black colour letter of hight 50 mm complete all as directed by Engr in Charge upto 1.5 mtr above ground level with alternate layer of white and black paint complete all as specified & as directed.
S &F street light fitting of 60 Watt LED made of pressure die cast aluminium housing with toughned glass and LEDs with secondary optics and IP 66 protection and lens embedded PC Cover having top opening seperate driver compartment ,should have luminaire efficacy ≥110 lumens/watt,CRI>70 ,PF > 0.95,CCT≥5500,IP66,impact resistance IK 07 ,inbuilt protection against lightning , over voltage , short circuit and surge/spike protection device upto 10 kV complete also tested for 440 Volt for 8 hour Phase to phase without any damage including taking down old unserviceable light fittings complete all as specified and as directed. ( NOTE :(i) PVC insulated PVC sheathed, multistranded aluminium or copper conductor cable of size 1.5 sqmmX 3 core from light fitting to Street light feeder (max 2.0 mtr ) deemed to be included in quoted rate. (ii) Manufacturer’s test certificate of LED light fitting in respect to LM 79 and LM 80 shall be submitted by the contractor.)
S &F street light fitting o f 45 Watt LED made of pressure die cast aluminium housing with toughned glass and LEDs with secondary optics and IP 66 protection and lens embedded PC Cover having top opening seperate driver compartment ,should have luminaire efficacy ≥110 lumens/watt,CRI>70 ,PF > 0.95,CCT≥5500,IP66,impact resistance IK 07 ,inbuilt protection against lightning , over voltage , short circuit and surge/spike protection device upto 10 kV complete also tested for 440 Volt for 8 hour Phase to phase without any damage including taking down old unserviceable light fittings complete all as specified and as directed. ( NOTE :(i) PVC insulated PVC sheathed, multistranded aluminium or copper conductor cable of size 1.5 sqmmX 3 core from light fitting to Street light feeder (max 2.0 mtr ) deemed to be included in quoted rate. (ii) Manufacturer’s test certificate of LED light fitting in respect to LM 79 and LM 80 shall be submitted by the contractor.)
S &F in repair Post Top LED light of capacity 40 Watt, housing made of aluminium alloy with polycarbonate diffuser having anti-aging spray treatment complete all as specified and as directed.
S &F in repair LED Bollard light having dicast aluminium housing with high corrosion resistance surface finish IP 65, operates on AC 120-300 V, 50 Hz upto 10 Watt with and including provision of foundation of size 300X300mm in PCC 1:3:6 type C-2 complete all as specified and as directed.
S&F in repair MCCB with Thermal - magnetic release of 80-100 Amps, 4 Pole, 415V, 25 kA, Ics=100%Icu with adjustable over load setting and adjustable short circuit setting including all accessories complete all as specified and as directed.
S&F in repair MCCB with Thermal - magnetic release of 125-160 Amps, 4 Pole, 415V, 25 kA, Ics=100%Icu with adjustable over load setting and adjustable short circuit setting including all accessories complete all as specified and as directed.
S&F in repair MCCB with Thermal - magnetic release of 200-250 Amps, 4 Pole, 415V, 36 kA, Ics=100%Icu with adjustable over load setting and adjustable short circuit setting including all accessories complete all as specified and as directed.
S&F in repair MCCB with Thermal - magnetic release of 320-400 Amps, 4 Pole, 415V,50 kA, Ics=100%Icu with adjustable over load setting and adjustable short circuit setting including all accessories complete all as specified and as directed.
S&F in repair MCCB with Thermal - magnetic release of 500-630 Amps, 4 Pole, 415V,70 kA, Ics=100%Icu with adjustable over load setting and adjustable short circuit setting including all accessories complete all as specified and as directed.
S&F in repair SS enclosure for MCCB of rating 250 Amps in built neutral link for TPN system 1 IK08 and IP 30 protection having louvers for better heat dissipation suitable to accommodate upto 185 Sqmm 3.5 core Aluminium armoured cable including taking down and refixing serviceable/ new MCCB in enclodsure and conecting existing IC/OG cable with proper dimension lugs complete all as specified and as directed. ( Note : The cost of New MCCB if provided under the item shall be measured and paid seperately).
M&L for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried in ground (Earth pit not less than 2.25 m deep below ground level ) with top edge of the plate not less than 1.5 m below normal ground level , connected to galvanised iron earth strip 25 mm x 4 mm as earth lead by means of nut, bolts check nut and wahser of galvanised iron or steel etc all as shown in electrical plate No.3 of SSR part I- 2009 connected to earth test point all as specified or indicated including PCC pit in PCC (1:3:6) type C-1 cast iron MS frame, 50 mm thick pre cast RCC (1:1 1/2:3) type nominal mixed cover slab rainforced with 8 mm dia MS deformed bar 15 C/C and suitable for handle cast including necessary exavation earth work in soft/loose soil and disposal of soil to adistance n exc 50 m and charcoal 120Kg, salt 105 kg, funnel with water pipe ,wire mesh, copper logs etc GI protection pipe of size 15 mm bore dia including tetsing complete including dismantling of old unservicable earthing & earth pit all as specified and directed by Engr-in-charge.
Taking down old unsv / corroded LT feeder pillar box / DB Box / Busbar Chamber of any sizes or types and disconnection of all electrical connections complete for replacement with new one, complete all as specified and as directed.
Supply, installation, testing and commissioning of factory made powder coated (CPRI approved) outdoor type, dust & vermin proof feeder pillar box made out of 3.15mm CRCA steel sheet of suitable size and angle iron 40 mm x 40mm x 6 mm , factory made duly fixed on the ground by PCC foundation (1:2:4 Type B-1) of size 300mm x300mm x600mm on the adjacent pairs of leg & net cementing the same. The feeder pillar box shall be duly painted with two coats of epoxy based powder coated over a coat of red oxide primer (internally & externally) on the surface all as specified and directed by Engr-in-Charge. The feeder pillar box is cubicle shaped, roof canopy type, with special type of heavy duty industrial door hinges and totally enclosed dust proof and vermin proof front and back opening with locking arrangements. The box shall have the provision/accommodation of the following electrical items:- INCOMING: (i) Aluminium bus bar 4 strips (covered with colour coded insulated PVC sleeves) 200 Amps capacity of suitable length including connection etc complete – 01 Set (ii) Indicator lamp for RYB phase (iii) Moulded case circuit breaker 80-100 Amps 415 Volts, Thermal Magnetic release with adjustable over load setting and adjustble short circuit setting,4 pole, ,Ics=100% Icu,25 kA breaking capacity.= 01 Nos.
Supply, installation, testing and commissioning of factory made powder coated (CPRI approved) outdoor type, dust & vermin proof feeder pillar box made out of 3.15mm CRCA steel sheet of suitable size and angle iron 40 mm x 40mm x 6 mm , factory made duly fixed on the ground by PCC foundation (1:2:4 Type B-1) of size700mm x300mm x600mm on the adjacent pairs of leg & net cementing the same. The feeder pillar box shall be duly painted with two coats of epoxy based powder quoted paint over a coat of red oxide primer (internally & externally) on the surface all as specified and directed by Engr-in-Charge. The feeder pillar box is cubicle shaped, roof canopy type, with special type of heavy duty industrial door hinges and totally enclosed dust proof and vermin proof front and back opening with locking arrangements. The box shall have provision/accommodation of the following electrical items:- INCOMING: (i) Aluminium bus bar 4 strips (covered with colour coded insulated PVC sleeves) of rating 1.5 times currrent carrying capacity of incoming switch gear or not less than 200 Amps whichever is higher of suitable length including connection etc complete – 01 Set (ii) Indicator lamp for RYB phase (iii) Moulded case circuit breaker 80-100 Amps 415 Volts, Thermal Magnetic release with adjustable over load setting and adjustble short circuit setting,4 pole, ,Ics=100% Icu,25 kA breaking capacity.= 01 Nos. (iv) VAF+PF multifunction meter CI flush mounting 96x96mm CT/PT site programmable including CTs.
OUTGOING: (i) Moulded case circuit breaker 63-80 Amps 415 Volts, Thermal Magnetic release with adjustable over load setting and adjustble short circuit setting,4 pole, ,Ics=100% Icu,25 kA breaking capacity.= 01 No. (ii) MCB Four pole of capacity 32 Amps, C curve of breaking capasity 10 Ka- 02 Nos. (iii) Astronomical timer ( Astro mini) 110-240 V AC , 1 phase. (iv) 3 pole contactor of current rating AC 1 50 Amps with inbuilt surge suppressor (v) MCB 2Amps SP 10 KA - 01 No. Note : All cables in the feeder pillar box shall be properly thimbled as directed and specified.
Repairs/maintenance of APFC LT Panel board/box upto 100 KVAR capacity including disconnecting all incoming and outgoing connection after taking necessary shut down, cleaning the carbon/rust from bus-bar, re-thimbling with new lugs/thimble of existing size, removing old burn out wiring and re-wiring with new cable of exising size, including replacement of unserviceable parts complete all as specified & directed :- Note :- (i) New spares shall be measured and paid separately under relevants items as supply only. (ii) Cost of unsheathed multistranded copper conductor of size upto 2.5 Sqmm for internal wiring like connection of CTs deemed to be included in quoted rate. (iii) All calibration of meters and APFC controller shall be done by the contractor after fixing in position. (iv) Suitable size of copper/aluminium cable lugs shall be provided by contractor for fixing/jointing the cable in bus bar etc.
Supply only Switch disconnector-fuse unit of current rating 100 Amp having terminal shrouds on both sides including phase barrier open execution type suitable for DIN fuse-link(4P) complete all as specified as directed. Make : L&T Cat Part No. SK90496 or equivalent in Havells/C&S.
Supply only digital 8 step APFC controller of size 96X96 for contractor switching, operating voltage 415V Volts complete all as specified and as directed. Make : L&T, Cat No CS90902OOOO or equivalent make of Schneider/ABB.
Supply only Indoor tape insulated ring type low tension current transformers of ratio 100/5A accuracy class 1.0 for LT panel board, complet all as specified and directed by Engr-in-Charge.
Supply only Indoor tape insulated ring type low tension current transformers of ratio 200/5A accuracy class 1.0 for LT panel board, complet all as specified and directed by Engr-in-Charge.
Supply only 3 Phase, 415 V power contactor of AC3 rating 25 Amp complete all as specified and as directed. Make : L&T Cat Part No CS94110 or equilvalent in Havells/ABB.
Supply only 3 Phase, 415 V power contactor of AC3 rating 32 Amp complete all as specified and as directed. Make : L&T Cat Part No CS94111 or equilvalent in Havells/ABB.
Supply only 3 Phase, 415 V power contactor of AC3 rating 40 Amp complete all as specified and as directed. Make : L&T Cat Part No CS94190 or equilvalent in Havells/ABB.
Supply only coil for MNX 25-MNX 40 contactor 240 V AC complete all as specified and as directed. Make : L&T Cat Part No CS94105 or equilvalent in Havells/ABB.
Supply only MNX contactor contact kit complete all as specified and as directed. Make : L&T Cat Part No CS94147 or equilvalent in Havells/ABB.
Supply only heavy duty cylindrical type capacitor of capacity 5 k VAR, suitable for operating on 440 Volts 3 Phase complete all as specified and as directed. Make : L&T or equivalent in Havells/ABB.
Supply only heavy duty cylindrical type capacitor of capacity 10 k VAR, suitable for operating on 440 Volts 3 Phase complete all as specified and as directed.
Supply only heavy duty cylindrical type capacitor of capacity 12.5 k VAR, suitable for operating on 440 Volts 3 Phase complete all as specified and as directed. Make : L&T or equivalent in Havells/ABB.
Supply only heavy duty cylindrical type gas filled capacitor of capacity 20 k VAR, suitable for operating on 440 Volts 3 Phase complete all as specified and as directed.
Supply only heavy duty cylindrical type capacitor of capacity 25 k VAR, suitable for operating on 440 Volts 3 Phase complete all as specified and as directed. Make : L&T or equivalent in Havells/ABB.
M&L for Cross arms, bracings, supports, clamps, eye hook and back plates fabricated from structural steel sections including pole clamps, stay clamps, D clamps nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed including painting with two coats of aluminium paint over a coat of red oxide primer including taking down the old unserviceable cross arms, clamps etc complete all as specified and as directed.
M&L for ACSR conductors (weasel type) for LT OH lines on poles including stringing, binding with aluminium wire 14 SWG or aluminium tape including jumpers complete connecting of disconnected cable, service cable and street light connection including dismantling of unserviceable ACSR conductor of any size from any position complete all as specified and as directed.
M & L for Prunning / trimming the branches of trees if any along overhead line, 3 m on all side below/ above/ sides of overhead line and removing the same upto a distance of 150m, each span not exceeding 45 m complete all as specified and as directed.
M & L cutting grasses, shrubs/herbs surrounding LT poles, feeder pillar box installations by mechanical or manual T&P, removing the debris at a distance not exceeding 50m and depositing where directed complete all as specified and as directed.
M & L for Stringing / stretching, including jointing in situ of each span not more than 45 m between two electric poles having 4 Nos of ACSR conductors of any size including GI earth continuity wire, with/ without guarding wires on electric poles of any size at different locations all as directed to the extent of permissible sag or tension by removing jumpers or bindings from insulators and making fresh binding with aluminium tapes after stringing complete all as specified and as directed. (Note :- One span measured as 4 Nos wire of LT over head line and 2 Nos of earth wire.)
M & L for Stringing / stretching, including jointing in situ of each span not more than 45 m between two electric poles having 2 Nos of ACSR conductors of any size including GI earth continuity wire, with/ without guarding wires on electric poles of any size at different locations all as ordered to the extent of permissible sag or tension by removing jumpers or bindings from insulators and making fresh binding with aluminium tapes after stringing complete all as specified and as directed. (Note :- One span measured as 2 Nos wire of LT over head line and 1 Nos of earth wire.)
M&L for cement concrete 1:4:8 type D-2 using 40 mm graded crushed stone aggregate as in foundation filling and mass concrete complete all as specified and as directed.
M&L for PCC 1: 3 : 6 type C-1 using 20 mm graded stone aggregate for coping to the new/ existing Steel Poles including necessary form work complete all as specified and as directed.
M&L for erection and fixing of steel tubular swaged pole type 410 SP - 31 (9.00 metres long) confirming to IS- 2713 Part I to III 1980 with and including cast iron base plate, finial taper plug, nuts, bolts and washers etc. fixed in PCC foundation duly painted painted with two coats of Aluminium paint over a coat of red oxide primer including preparation of surface and including dismsntling of old pole of any size and description with foundation, PCC coping etc. complete all as specified and as directed.
M&L for stay assembly comprising 14mm dia iron stay bow, stay strand wire of size 7/3.15mm with stay rod of diameter 16mm complete with all accessories as shown in electrical plate no. 1 of SSR part-I 2009 including dismsntling of old stay assembly of any description with foundation, etc. complete all as specified and as directed.
M&L for loop type insulator, vitreous porcelain, white, brown or green with overall dimension 90mmX140mm, clearence of hole 25.5mm suitable for 1100 Volts complete all as specified and as directed.
M&L in repair for Air termination, single pointed, aluminium rod 12 mm dia and 300mm long to be fixed on horizontal lightning conductor with suitable fixing arrangement all as specified and directed.
M&L in repair for Air termination, single pointed, copper rod 12 mm dia and 300mm long to be fixed on horizontal lightning conductor with suitable fixing arrangement all as specified and directed.
Taking out old GI/aluminium strip of any size and type in any height and any location as directed by Enginner-in-Charge.
Refixing of serviceable aluminium strip/GI strip obtained form taking out old GI/Aluminium strip on top of "V" type procelain insulator of sutitable size, GI nuts and bolt, screws cleats etc. (Cost of procelain insulator deemed to be included in quoted rate) duly straightened properly as directed by Enginner-in-Charge. Note : The distance between two porcelain insulator shall be one metre.
M&L for aluminium strip 25 x 3.15 mm with "V" type porcelain insulator or DMC insulator of suitbale size and fixing with GI screws etc. for roof conductors and down conductors above ground complete all as specified and directed.
M&L for copper strip 20 x 3.15 mm with "V" type porcelain insulator or DMC insulator of suitbale size and fixing with GI screws etc. for roof conductors and down conductors above ground complete all as specified and directed.
M&L in repair for test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 03 Nos 8mm dia 25mm long hexagonal head screws for fixing strips to test point including necessary fixing arrangement to fix test point terminal block to test point junction box all as specified and directed. complete all as specified and directed.
J K CONSTRUCTION
PURBANCHAL BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .