Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹83.0 LAdmitted-Finance | -37.89% | ₹83.0 L | L1 | Admitted-Finance |
| 2 | L2₹89.4 L+₹6.4 L (7.68%)Admitted-Finance | -33.12% | ₹89.4 L+₹6.4 L (7.68%) | L2 | Admitted-Finance |
| 3 | L3₹92.5 L+₹9.5 L (11.5%)Admitted-Finance | -30.77% | ₹92.5 L+₹9.5 L (11.5%) | L3 | Admitted-Finance |
| 4 | L4₹1.0 Cr+₹21.4 L (25.8%)Admitted-Finance | -21.88% | ₹1.0 Cr+₹21.4 L (25.8%) | L4 | Admitted-Finance |
| 5 | L5₹1.1 Cr+₹28.8 L (34.7%)Admitted-Finance 245 MOHD YOUNIS BHAT MALIKPORA PULWAMA MALIKPORA PULWAMA JAMMU KASHMIR 192301 | PULWAMA | JAMMU AND KASHMIR | 192301 | -16.33% | ₹1.1 Cr+₹28.8 L (34.7%) | L5 | Admitted-Finance |
Tender Value
₹1.3 Cr
EMD Value
₹2.7 L
Closing Date
19 Jan 2026, 4:30 pmClosed
Dy. General Manager Housing Board Unit-II, Sgr.
Dy. General Manager Housing Board Unit-II, Sgr.
Construction of Primary Health Centre at Nasrullahpora, Budgam. (Balance Work)
2026_HAUDD_299994_1
Fresh e-NIT No. 11 of 01/2025-26, Dated 06-01-2026
Open Tender
Civil Works - Others
Percentage
180 days
Dy. General Manager Housing Board Unit-II, Sgr.
As per NIT
2 documents required · 2 mandatory
₹5,000
Dy. General Manager Housing Board Unit-II, Sgr.
₹2.7 L
31 Jan 2026
7 Jan 2026
20 Jan 2026
7 Jan 2026
19 Jan 2026
7 Jan 2026
Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position Budloo wood :
Providing and fixing 20mm thick wooden planks false ceiling (frame work for base to be paid for separately) with M.S. screws poplar wood.
Providing and fixing 10 mm ply wood , in ceiling with necessary nails etc. complete (frame work to be paid separately) :
Providing and applying Acrylic putty over plywood to prepare the surface even and smooth complete
Providing and fixing wooden moulded corner beading of size 50x50 mm (base and height) of triangular shape to the junction of paneling etc. with iron screws, plugs and priming coat on unexposed surface etc. complete. Second class kail wood
Providing and fixing of 3mm thick sunboard vinyl name plates including all fixtures & carriages upto site complete
Manufacturing supplying and fixing retro reflective overhead signage boards made up of 2mm thick aluminum sheet, face to be fully covered with high intensity and encapsulated lens type heat activated retro reflective sheeting conforming to type-III of ASTM-D-4956-01 as approved by Engineer-in-charge; letters, borders etc. as per IRC : 67-2001 in silver white with blue colour background and with high intensity grade, pasted on substrate by pressure sensitive adhesive backing which shall be activated by applying pressure conforming to class -II of ASTM-D-4956- 01 and fixing the same to the plate of structural frame work by means of suitable sized aluminum alloys, rivets or bolts and nuts @ 300mm c/c all along the periphery as well as in two vertical rows along with theft resistant measures including the cost of painting with two or more coats of epoxy paint in grey colour on the back side of aluminum sheet including appropriate priming coat. The rate includes the cost of rounding off the corners, lowering down the structural frame work from the gantry, fixing and erecting the same in position all complete as per drawing, specification and direction of Engineer-in-charge (Structural frame work including M.S. plate to be provided separately. Rectangular area of the sheet only shall be measured for payment)
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry bricks 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth.
Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6mm, with 40mm dia, steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer,
Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI: 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet & over flow pipes. The base support i/c fittings & fixtures for tank shall be paid separately.
Providing and applying cement based wall putty of required thickness over plastered surface to prepare the surface even and smooth complete in specified areas as per specified patter. (Birla make) (including cost of all material, leads, lifts and carriages etc upto site of work complete).
Wall painting with acryllic emulsion paint of approved brand and manufacutre to give an even shade over smooth surface of approved quality including the cost of carriage etc
Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm
Applying priming coat with ready mix wood primer of approved brand including the cost of carriage etc.
Painting with synthetic enamel paing of approved brand and manufacture to give even shade
P/F of MS grill of required pattern and design in frames of windows etc
Providing and fixing 3.5mm thick panels of plain glass for fixed glazing panels/ shutters (only panel area to be measured) including cost of teak wood beadings of required size complete
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5 km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
Providing and Laying of stone soling hand packed including all carriages upto site complete.
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Centering and shuttering including strutting, propping etc. and removal of form work for Retaining walls, return walls, walls (any thickness) including attached pilasters buttresses, plinth and string course fillets, kerbs andsteps etc.
Applying 12mm Cement plaster of mix 1 : 4 ( 1 cement : 4 fine sand)
Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Welded
Supplying and stacking of good earth at site including royalty (earth measured in stacks will be reduced by 20% for payment)
Spreading of sludge, dump manure or/and good earth in required thickness as per directions of officer in-charge (cost of sludge, dump manure or/and good earth to be paid separately)
Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables, etc (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift up to 1.5m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres, all kinds of soil.
Cast-in-situ of concrete work of nominal mix concrete M7.5 grade (1:4:8) nominal maximum size of stone aggregate 40mm volumetric batching in foundation trenches and ground floor, including curing but excluding formwork costs.
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work,using cement content as per approved design mix,incluyding pumping of concrete to site laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportiond as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. Note: - Cement in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is content considered payable or recoverable seperately.
All works upto plinth level
All works above plinth level upto floor V level
Supplying and filling in plinth with GSB/ Second class sand including, watering, ramming, consolidating and dressing complete.
Steel reinforcement for R.C.C. works including straightening, cutting, bending, placing in position and binding - all complete from foundation to roof level of Thermo-Mechanically Treated bars of grade Fe-500D or higher.
Providing and applying 20mm cement plaster finished with a floating coat of neat cement of mix.
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservoir, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of selfhealing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-incharge. The product performance shall carry guarantee for 10 years against any leakage.
For vertical surface two coats @ 0.70 kg per sqm
For horizontal surface one coat @1.10 kg per sqm.
Providing and fixing Circular shape 560 mm dia precast R.C.C. manhole cover with frame - E.H.D. - 36
SITC 2HP 15 Stage Single Phase Pure Copper Oil filled submersible pump set for underground water storage sump with control panel, 60m safety wire & 50m submersible cable.
Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts,struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchors blocks, plain window sills, fillets etcupto floor V level, including curing but excluding the cost of centring, shuttering and finishing with. 1:1½:3 (1 cement :1½ coarse sand: 3 graded stone aggregate 20 mm nominal size)
15mm Cement plaster on the rough side of single or half brick wall of mix incl all carriages complete: 1 : 6 ( 1 cement : 6 fine sand)
Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
Providing and laying 60mm thick factory made cement concrete interlocking paver block of M-30 grade made by block making machine with strong vibratory compaction and of approved size and design/shape laid in required colour and pattern over and including 50mm thick compacted bed of fine sand, filling the joints with coarse sand etc. all complete as per direction of Engineer-in-charge.
Chequerred precast cement concrete tiles 22mm thick in footpath and courtyard, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing, cleaning and curing complete, on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand) . Medium shade using 50% white cement and 50% ordinary cement.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement in position to the required line, level and curvature jointed with cement mortar 1:3 (1 cement: 3 coarse sand) including making joints with or without grooves (thickness of the joints except at sharp curve shall not to be more than 5mm) including making drainage opening wherever required complete etc. as per direction of Engineer-incharge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z. sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber I neoprene .. gasket felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing I panelling, C.P. brass I stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in- Charge (glazing, panelling and dash fasteners to be paid for separately.) Powder coated aluminium (minimum thckness of powder coated 50 microns) including beading.
For shutters of doors, windows & ventilators including providing and fixing hinges I pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber I neoprene gasket required (Fittings shall be paid for separately.) Powder coated aluminium (minimum thickness of powder coated 50 microns)
Providing and fixing 8mm thick HPL panels in aluminium door , windows, ventilator shutters and partitions etc complete as per architectural drawings and the direction sof engineer in charge
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber I neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item.)With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
Filling the gap in between aluminum frame and adjacent RCC/Brick/Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. Upto 5mm depth and 5mm width
Providing and fixing aluminium door, window, ventilator hardware accessories including cost of all fixtures & carriages upto site, etc. complete as per the directions of engineer-in-charge.
Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.
Tower bolts 100mm
Handle 100mm
Tower bolts 150mm
Handle 125mm
sliding door bolts 250x16 mm
hanging floor door stopper, Single rubber stopper
butt hinges of 100x63x3.2 mm
Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, for all heights and all levels etc. including cost of frame of stainless steel tubular sections & all fixtures and carriages upto site complete.
Electrical Work
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group C
Wiring for Light /Power Plug with 2 x 4 sq.mm FRLS PVC Insulated Copper Conductor single core cable in surface/Recessed medium class PVC Conduit along with 1 No. 4 sq.mm FRLS PVC Insulated copper conductor single core cable for loop earthing as required.
Wiring for Circuit/Submain Wiring along with earth Wire with the following Sizes of FRLSPVC insulated copper conductor,single core Cable in surface/Recessed medium class PVC conduit as required.
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
4 X 16 sq. mm + 2 X 6 sq. mm earth wire
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supply and fixing modular blanking plate on the existing modular plate and switch box excluding modular plate as required
Supplying and Fixing suitable size G.I box with modular plate and cover in front on surface or in recess,including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps modular switch,connection,painting etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required.
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8 way (4 + 24), Double door
6 way (4 + 18), Double door
4 way (4 + 12), Double door
Supplying and fixing following rating, four pole, 415 V, 10 Ka M.C.B in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 5 amps. to 32 amps.rating 240 volts 'C' series, miniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single Pole
Double Pole
Supply and Fixing Single Pole Blanking Plate in the Existing MCB DB complete as Required.
Necessary soil treatment is to be made by the contractor in order to improve the Pit resistance value.
Chemical Earthing with including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. as required.
Earth pit chamber (300mm x 300mm) with CI cover for the above.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Supplying,Installation,Testing and Commissioning of Copper Earthing Electrode of Size 50 x 3000mm with Copper Pipe Outer Dia. 50 mm (+-) 5 %),Length 3000 mm,Inner & and Outer Strip Size 25X6mm (Copper),Terminal Hole Two Nos.,Terminal Hole Dia. 14 mm,Seal Plate Thickness 4 mm,Base Plate Thickness 4 mm,Inner filling Material – Highly Conductive Super Crystalline Mixture,Outer filling material - Highly Hygroscopic, Non corrosive Back Fill Compound 50 Kgs.
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
Supply installation testing and commissioning of Ceiling Fan with Voltage Range 90 V to 300 V,Min. Air Delivery 212 CMM,Service Value 5.3 Cu.m/min/watt,Aluminium Blades ,including wiring the down rods of standard length(Upto 45 cm)with 1.5 sq.mm FR PVC insulated,copper conductor,single core cable including providing and fixing phenolic laminated sheet cover on the Fan Box etc as Required.
Supply,Installation,Testing and Commissioning 486 Cu.m/Hr. AC 220-240 Volts, 50 Hz exhaust fan noise Level not exceeding 37 dB of Following Sizes including connection etc. complete as required .
Supply & Fixing of 36W , 2x2 LED reccesse type Luminaire suitable for operating Voltage range of 150V-270V with inbuilt surge protection of 2KV and Color temprature 5700K ANSI BIN . Minimum system lumens 4320 and system efficacy >120 Lm/watt (Supported by in house NABL approved report of LM79 provided by OEM and duly signed by company manager not below rank of RM) . Luminaire should be suitable for armstrong /grid ceiling mounting with help of 4 Nos clips for suspension. Body made up of CRCA powder coated with Diffused Optics. Luminaire size should not be less than 595x595x60mm and power factor >=0.95, CRI>=80, THD<10%, Max system wattage should be 36 Watt, IP-20 ingress protection. NABL certification and BIS (both luminaire and driver) requried to be provided at the time of sample approval.
Supply installation testing and commissioning of IP20 led downlighter 18 W +/- 1 W LED Recess downlighter round shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Heat Sink and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved Inhouse NABL lab/ government of India authorised lab .
Supply installation testing and commissioning of IP20 led downlighter 15 W-18 W +/- 1 W LED Surface downlighter round shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Heat Sink and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved Inhouse NABL lab/ government of India authorised lab .
Supply installation testing and commissioning of IP65 led Street Light 90 W +/- 5 W complete with M.S/G.I Pipe(Duly Bracket embedded along with Parapet/Wall including complete connections as required .The P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80. The LED with Useful life of 50000 Hrs at L70. The Input voltage range shall be 150V to 265V. The Fixture should have In-built Surge Protection of 2.5kV Certification:- LM79 & LM80 test report should be from govt approved Inhouse NABL lab/ government of India authorised lab .
Supplying,Installation,Testing and Commissioning of Cubical Type Outdoor LT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars etc. as required as per the Following Description.(IP:42)(Main Distribution Panel) .The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A. drawing, wiring diagrams, single line diagram before start of fabrication of LT panel.Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating.The Panel Builder Shall be CPRI /ERDA/ANY NABL ACCREDITED LAB approved.Refer SLD
INCOMER
MCCB 250 A F.P 36 Ka with Adj.T.M.R With Icu=Ics=100%(02 Nos)
OUTGOINGS
D.P M.C.B 16 A 10 Ka with "C" Curve(04 Nos)
D.P M.C.B 40 A 10 Ka with "C" Curve(02 Nos)
F.P M.C.B 63 A 10 Ka with "C" Curve (07 Nos)
F.P M.C.B 40 A 10 Ka with "C" Curve (05 Nos)
Size of wiring for CTS:- 2.5 sqmm
Size of wiring for voltage sensing Metering :-4.0 Sq.mm
Size of wiring of all push buttons, indicating lamps:-1.5 Sq.mm
Types of wires:-PVC insulated 1100V grade ,Multistrand copper conductor Flexible FR-LSH
Hinged Door Earthing:-Device mounted hinged doors connected to cubicles body by means of 2.5 sqmm.green copper flexible wire .
The Complete Panel Shall be Made out of 2.0 mm CRCA sheet including Frame/Partitions/Doors etc.
Gland Plates to be 3.0 mm Thick.
Supplying,Installation,Testing and Commissioning of Cubical Type Outdoor LT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System (X-Ray Room Panel). (2x2)
INCOMER/OUTGOING
MCCB 63 A F.P 16 Ka (1 Nos)
Comprising Indicating Lamps and MCB Strip of suitable size etc. as Required.
The Complete Panel Shall be Made out of 2.0 mm CRCA sheet including Frame/Partitions/Doors etc.
Gland Plates to be 3.0 mm Thick.
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
120 mm dia (OD-120 mm & ID-103 mm nominal)
Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in groundin Existing DWC Pipe including excavation, sand cushioning, protective covering and refilling the trench etc as required.
3.5 C X 95 Sq.mm A2XFY
3.5 C X 50 Sq.mm A2XFY
3.5 C X 35 Sq.mm A2XFY
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
Telephone socket outlet
Computer Socket RJ45 Modular type
TV antenna socket outlet
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
1 or 2 Module (75mmX75mm)
Supplying and Fixing of Following sizes of PVC Conduit along with Accessories in surface/Recess including painting in case of surface conduit,cutting the wall and making good the same in case of recessed conduit as required.
25mm PVC Conduit
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.
1 run of cable
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
Supply, installation, testing and commissioning of Junction Boxes/DB-10 Pairs with Original Krone module and Back Mount Frame and have Lock -n- key, complete in all respect as per specification and desired by EIC
Supply & Erection of lockable 12 U rack with 5A strip and two fan for distribution, mounting of patch panels, hubs, switches etc,, complete as per specification and as desired by EIC.
Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required.
Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required.
Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required
2 x 1.5 sq. mm
Supplying,Installation,Testing and Commissioning of Ceiling Mounted Automated Modular Fire Suppression System (ABC MAP90 Powder Based ) - 10KG suitable for Class A, B, C and Electrically started fires.
SITC of Dry Type Co2 Type Fire Extinguisher 4.5 Kg
SITC of ABC Type Fire Extinguisher IS 15683 4.0 Kg Having Deep drawn and CO2 MIG welded can construction ,Epoxy polyester powder external coating,Epoxy powder internal coating,Body Thickness 1.6 mm(Cease fire)
Supply, transportation,Unloading , installation,testing & Commissioning of Online UPS 5KVA/4 KW (1Ø IN:1Ø OUT) with 15 min backup : True Online Pure Sine wave DSP Controlled online UPS with 1 phase AC input and 1 phase AC output with 15 minutes backup with SMF batteries Bank .The UPS should be Capable of Phase Sequence Correction and should be with SNMP Card and along with Battery Temp. Sensor Kit.
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.38 MB
BOQ_973373.xls
BOQ • 0.52 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .