Executive Engineer, BUILDING CINSTRUCTION DIVISION 1
EE
Executive Engineer, BUILDING CINSTRUCTION DIVISION 1, BCD
Superintending Engineer, Construction Circle PATNA
SE
Additional Work of Block- A, Block-B & Newly Constructed Block - C (With Civil & Electrical Work ) of Bapu Pariksha Parisar at Kumhrar ,Patna.
131397
NIT 1/BCD/CONS DIV 01/2026-27
Open Tender
CIVIL
Patna
• Bid Security Amount in Rupees Unconditional bank guarantee from any scheduled Indian bank issued within the state in the format given. 16.1
Total Bid Security Amount in Rupees 5,97500.00 IFB
• 2 (i) Legal Status of Bidder (select from drop down list) 4.3(a)
(ii) Place of Registration. (select from drop down list)
(iii) write Principal place of Business
(iv) Power of attorney of signatory Bid (select from drop down list) 4.2(iv)
• Total value of civil engineering construction work, in Rupees, Performed in last five years. minimum annual financial turnover (in all classes of civil engineering construction works only) amount of construction work of at least the equal to the 50 % of estimated cost of works for which bid has been invited. The turn over will be indexed at the rate of 8% for a year 4.5(A) (a)
2021 - 2022
2022 - 2023
2023 - 2024
2024 - 2025
2025 - 2026
• Amout in Rupees related to Work Experience of Similar nature Satisfactory completed at least one similar work of value not less than 50% of estimated Cost 4.5(A) (b)
(c) Executed in any one year, the minimum quantities of the following items of work as indicated in Appendix.
Sr. No. NAME OF ITEM UNIT Qty
1 RCC Cum 15
2 Steel work Welded Kg 6349
3 Paver Block Work Sqm 385
4 Tensile Membrance Sqm 350
5 Electrical Work Lakh 56.49
• Electrical License The contractor or his identified sub-contractor should possess required valid electrical license for executing the building electrification works and should have executed similar electrical works for a minimum amount as indicated in Appendix in any one year 4.5A( d)
• (a) Amount of Existing commitments and ongoing works in Rupees Sec 2-1.4(A)
• (b) Amount of Work for which Bid already submitted, in Rupees Sec 2-1.4(B)
• Numbers and Maximum age of Equipments with bidder Type of Equipment Nos. Maxm. Age Sec 2-1.5
Concrete Mixer with Integral weigh Batching facility 5 1
Vibrator (Plate & Niddle) 5 2
Water Tanker 5 1
Steel shuttering 5 2000sft
• Name of the Personnel and Experince in years and Select from drop down list Personnel / Qualification 4.5(B) (b)
Site Engineer B.E. (Civil/ Electrical ) + 03 Years Exp. (3 years in Building Construction) or Diploma in Civil /Electrical+ 7 year Exp. In Building construction or retired A.E. 1 No.
Site Supervisor Fresh Graduate in Civil and Electrical or Diploma Civil/ Electrical + 02 Years Exp. or retired I.T.I Holder. 1 No.
• Evidence of accesses to Financial Resources in Rupees Evidence of access to or availability of creadit facilities (10% of estimated cost), certified by bankers (for work under this bid). 4.2(i)
• Proposed methodology and programme of construction Select from drop down list the proposed methodology and programme of construction, backed with equipment planning and deployment 4.3(l)
• Litigation History. Select from drop down list. Information regarding any litigation, current or during the last five years, in which the Bidder is involved, the parties concerned, and disputed amount. (Attached or not) 4.3(j)
• Affidavit Select from drop down list. Regarding statements made in the required attachments are true and correct. Sec-2, Affidavit
• Undertaking Select from drop down list. Able to invest a minimum of cost upto 25% of contract value of work. During implementation of contract. Sec-2, Undertaking
• Time of Completion in months 3 Months
• Registration No.
IT.& ST Registration & clearance Certificate
• Labour License
• Character Certificate
NOC for Debar (If required)
CIVIL
PERCENTAGE
L1
1
21 documents required · 21 mandatory
₹10,000
Processing Fee: 3540
₹6.0 L
2:- Date 21-05-2026 15.00 hrs at office of S.E., Construction Circle, BCD, Patna.
12 May 2026
12 May 2026
10 Jun 2026
13 May 2026
9 Jun 2026
13 May 2026
18 May 2026
Earth work in excavation in foundation trenches or drains(not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
All kinds of soil
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth: consolidating each deposited layer by ramming and watering lead
Supplying and filling in plinth with local sand under floors,including watering, ramming, consolidating and dressing complete.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:3:6 (1 Cement: 3 coarse sand:6 graded stone aggregate 20 mm cum nominal size
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana /Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate /retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.
All works up to plinth level
Centering and shuttering including strutting, propping etc. and removal of form for :
Foundations, footings, bases of columns etc. for mass concrete.
Steel reinforcement for R.C.C. work including straightening,cutting, bending, placing in position and binding all complete upto plinth level
Thermo-Mechanically Treated bars TMTC-500-8mm dia.
Thermo-Mechanically Treated bars TMTC-500-10mm dia.
Thermo-Mechanically Treated bars TMTC-500-12mm dia
Thermo-Mechanically Treated bars TMT Fe-500-16mrn dia.
Steel work welded in built up sections/framed work including cutting hoisting, rixing in position and applying a priming coat of approved steel primer using structural steel, etc. as required. In gratings, frames, guard bar, ladders, railings, brackts. gates & similar works.
Supply of Galvanised steel birbed wire.
Providing and fixing in position collapsible steel shutters with vertical channes 20x10x2 mm and braced with flat iron diagonals 20x5 mm size with top and bottom rail of T-tron 40x40x6 mm with 40 mm dia steel pulleys complete with bots.nuts locking arrangement stoppers handies including applying a priming coat of approved steel primer.
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge.
Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge.
With material conforming to Grade-III (size range 26.5 mm to 0.075 mm ) having CBR Value-20
Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved s;ze, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.
Providing and fixing on wall face unplastidsed-PVC(working pressure 4 kgf per sqm) rain water pipes conforming to IS :4985 including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion.
Painting with ready mixed paint of approved brand and manufacture in all shades to give an even shade:
Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance ?85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm ) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade:
Providing and fixing retro reflective signboard MS square pipe frame structure ACP sheet pasting Retro reflector fitting and labour cost, size - 20 fit x 1.5 fit
Providing and fixing ACP Retro Reflective Board Gate No Size - 2 fit x 1.5
Making 25cm (10") dia bore upto 4mtr depth below ground with hand auger of approved quality inordinary soil (video classification of soil item A) true to plum band without eccentri city in any stage of operation and disposal of the excavate dearth upto50mtr ,Leadind iluding all lifts,all complete as per approved disign and direction of E/l Details of cost for 4 piles of 4m =16mtrs depth )
Providing and laying autoclaved aerated cement block smasonry with 150mm/230mm/300mm thick AAC blocks in super structure above plinth level upto floorV leve lwith RCC band at sill leveland lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).
1:6(1 cement: 6 coarse sand)
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade:
Providing, Designing, Engineering, Patterning, Fabrication, Supplying and installation of Architectural Membrane, Assembling, Hoisting, Erecting and placing in position MS built-up section/Tubular structure frame work using MS plates of variable thickness confirming to Is 2062 (Grade YST 240) and Tubular structure made from Steel hollow sections, ISl marked confirming IS 1161/4923 (Grade YST 240) in the profile and including necessary foundation bolts & base plates. Fabrication of structural elements shall be done using AW/MAW/MIG welding process. In the profile shape as per drawings with special plate connector, pinion joints, plates, hollow sections etc. with cleaning the surface and including Preparation of detailed rchitectural Membraneation and erection drawings of Structural steel work from design, drawings issued by Engineer-In-Charge and incorporation of Engineer-in-Charge's comment on same, transportation from Architectural Membrane yard, cutting, threading, machining, leads and lifts up to all heights, tools and plants and necessary scaffolding etc. required for all operations involved to make structure of Architectural Membrane shade. All members shall be hot finished welded type tubes.
VRV/VRF outdoor AC unit:- Supply installation testing and commissioning of VRV /VRF /MRV outdoor units with following multiple inverter based scroll type compressors, electronic expansion valve, R 410A/ecofriendly green refrigerant, cooling & heating mode both options, special pre-coated fin type heat exchanger, low noise direct driven propeller condenser fans in each module with top discharge including internal wiring, microprocessor controls, safety. The condensing unit should be capable of providing cooling between +/- 5deg. C. to 48 deg. C & heating within O deg. C to 15 deg. C, COP not less than 3.3. complete as per specification. Outdoor/indoor units should be of same make (brand}. (Single phase/three phase}
VRF/VRV indoor AC unit (high static ductable) :-Supply, installation, testing and commissioning of high static ductable type comprising of copper evaporator, electronic expansion valve, blower, motor, filter pad, with inbuilt drain pump including internal wiring, controls with cordless remote.(Single phase/three phase)
Y joints:- Supply, installation, testing & commissioning of ref nut/Y-joints brass for indoor and outdoor units of suitable size as per requirement,
Outdoor stand fabrication :- Supply, fabrication and erection of angle/channel/flat iron stand, hanging arrangement for air conditioning machines & ducts etc, back /support clamps or other similar work etc. including nut bolts of required size, making holes, fabrication, welding, cutting, etc. and painting with one coat of red oxide paint & two coat of enamel paint as required as per specification.
Drain piping :-· Providing and fixing of CPVC, 6Kg/cm2 drain water piping with fittings, support and insulated with 6 mm thick closed cell elastomeric nitrile rubber insulation complete as per specification.
Meter
Meter
Meter
Copper piping: - Supply, installation, testing and commissioning of interconnecting copper refrigerant pipe work (19mm/13mm thick) duly insulated with elastomeric nitrile rubber type tubular insulation between indoor & outdoor units as per specifications. And exposed piping should be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection.Joints shall be be covered with nitrile rubber tape of 3 mm thick complete as per specification.
Meter
Meter
Meter
Meter
Meter
Control cable: - Supply and laying, testing & commissioning of following sizes of shielded copper conductor Communication cables on existing tray including fixing clamps & proper connections to equipment etc. complete as required.
Refrigerant:Supply and additional refrigerant charge of refrigerant R410/410A & equivalent Eco friendly green gas to compensate the additional piping done at site for all systems including testing commissioning as required.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.
Metre
Metre
Wiring for light/ power plug with 2 X 4 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit along with 1 Nos 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
Supplying and fixing following modula'r switch/ socket on the existing modular plate & switch box including connections but excluding modular plate.etc. as required.
Supply and fixing of following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required.
Supplying and fixing following way, vertical type three pole & neutral, sheet steel, MCB distribution board, 415V, on surface/ recces , complete with tinned copper bus bar, neutral bus bar, earth bar, din bar interconnections, powder painted including earthing etc. as required (But without mccb and incomer) as required' (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
Supplying & fixing following rating 240/415 volts 10 kA, C curve Miniature Circuit Breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying & fixing following rating 240/415 volts 36 kA, C curve MCCB suitable for inductive loads of following poles in the existing MCCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing recess mounted 36 watt LED flat panel (2' X 2') with minimum efficacy 100 lm/w which privides soft light and glare free symmetrical illumination suitable for armstrong/grid ceiling and integrated electronic driver etc directly on false ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required.
Supplyiing, installation, testing and Commissioning of IP at its core with IP switching technology and 100% non blocking communication system with 04 Port Voicemail, 04 Port FXS, 04 Port FXO, 1 PRI Trunk lines (30 Channels) Circuit with CLIP Facility, min 100 IP users License with provision for further additions, 100 analog users, 01 Number IP based Operator Console, 45 Party Conference, Speed Dial, Music on Hold, Internal/ External ring difference, Call Barring, Call Pickup. The system should be redundant which offer 100% duplication of power supply and CPU card and to match the hybrid IP-PBX as per technical specification including supporting accessories etc complete as required. The system should have valid(1pair of 60 set)
Supplying and drawing 20 Pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC Conduit etc. complete as required.
Software for Web based Access Control System Supplying, Installation, Testing and Commissioning of Web based Access Control Enrolment and Device Configuration Software, Should be independent of OS (Windows), Unified Management of Biometric, Card, and Controllers, Import Functionality for bulk user details, Biometric Template Retrieval for Data Recovery, User Management, Logs and Terminal Management, Support for IP-based and USB Biometric Devices, User-specific Access Policies, Different User Policies on the Same Terminal, Assignment of Specific Access Schedules, Pushing Users to Terminals or Groups, Admin Authority Management to define rights of each user to perform, Blacklist User Management, Access Schedule Creation, Real-Time Log Retrieval, Real- Time User Identification, Secure Storage of Biometric/Users Data,Capable to integrate with 3rd party applications overWeb API's, MQTT protocol support
SITC of 24 Port Manageable Distribution Switch with 12 × 10G SFP+ ports; 12× 10G-T RJ-45 Ports / 12× 10G-T RJ-45 line, with 2 Ports Uplink 2 × 10G-T 40G QSFP+ and dual hotswap PSU bays, Premium L3 License for 3 Years, Warranty: 3 year from Day 1. Make: CISCO, Product – C9300X-24Y-A
SITC of 24 Port POE Access Switch 10/100/1000T stackable L2 switch with 4× SFP+ ports and single fixed power supplies, 1 meter SFP+ direct attach Stack cable; 3 year OEM Warranty from Day 1. Make: CISCO, Product – C9200L-24P-4X-E
SITC of Multi Mode 10G-Base-SR SFP+ module; Make: CISCO, Product – SFP-10G-SR=
Providing, fixing, terminating and testing of Modular of 24 port unshielded I/O SC type with required blanking plates. Make: Legrand
Providing, fixing, fitting, connecting and testing of SCLU duplex cords MM OS1/OS2 OM3 50/125um 2 Mtrs Length PC. Make: Legrand
Providing, fixing, fitting, connecting and testing of SCLU duplex cords MM OS1/OS2 OM3 50/125um 2 Mtrs Length PC. Make: Legrand
SITC of CCTV Network Video Management cum Recording Server in N+1 configuration as per Offered Solution with The main servers will be Intel Xeon processor or better, minimum speed of 2.3 GHz with Quad Core, Dual Gigabit Ethernet Port, USB port, Video port.With Server: Recording-Intel Xeon Silver 4210R, 2.4GHz, 32GB, 16TB-05 Nos.The server memory is be 16 GB DDR4 RAM with operation and Video Consumption management Licenses to manage at least 1200 Cameras. With Recording Lisc.+ N+1 Lifetime for 233 Camera. Make- Honeywell & Lenovo , Product- Maxpro NVR & SR650V2
42 U floor mount Rack: Supply of Fully Loaded 42 U 19" floor mount networking cabinet 800*1000 Rack with all required accessories - 4 Nos. of Fan, 16A 10 Plug PDU-2 Nos., Cable Manager-8 Nos., Mounting Screws-200 Pcs. - 42UX800Wx1000D, MCAB BT 42U810 A - Moducab Networking - 42U - 800W - 1000, MCAB GDR BT 42U8 CAM Moducab Front Glass Door - 42U - 800W - Cam Lock - Ventilation - Black Fine Tex. Assembly, 3 INCH CASTOR SET FOR MCAB D3 Inch Castor Set Modu Cab, FOUR Fan For MCAB/Prof -Four Fan For Mcab/ProTek FS, MONITOR TRAY BT 6X700 A- Monitor Tray - Ventilation - 495W - 700D - Black Fine Tex. Assembly, CABLE MNG PLOOP BT 1U A - Metal Cable Manager - 01 U - Plastic Cable Loop's Mountable - Black Fine Tex. Assembly, PDU 16A 10SKT MCB PLG A - Power Distribution Unit - 06/16 Amp Indian-Standard/ Current 16 Amp 3 Pin Plug with Power Cable 2.5 sq.mm 3 meter Length - Mounting Hole / Screw Mountable / 16 Amp MCB / Alternating Hardware Cable 5 Sq. mm Ti meter length PDU 1.6 Mtr Pin Plug with Power Cable 2.5 sq.mm 3 meter Length - Assembly, HARDWARE PKT 20SET - Mounting Hardware Packet ( Containing 10 Nos Each Of 3 ) - 20 Set , Cost of Floor Mount 42U Rack. Make - Legrand
SITC for UTP Cat. 6A patch panels equipped with 24 RJ 45 connectors 19" panel – 1 U Equipped with 4 cassettes of 6 pre-fitted Cat. 6A LCS³ RJ 45 connectors, Automatic cassette removal by simple pressure, Each connector terminates, recommended individually, T568A and B marking with colour codes, Equipped with rear cable guide to hold cables during maintenance, Supplied with coloured labels, Compliant with ISO/IEC 11 801, EN 50173 and ANSI/TIA 568 standards, Flat panels, 24 RJ 45 connectors – 1U. Suitable for UTP. Equipped with new-generation Quick-Fix for automatic (screwless) mounting on enclosure and cabinet uprights, Universal mounting on all cabinets or enclosures, Panels ensure automatic earthing of each connector, equipped with 4 bundles guides fixed at the rear.Make – Legrand
Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range: -5° to +60°C, Bending Radius: < 4 X Cable Diameter at -5°C ± 1°C and Pulling Force : 11.5Kg etc. complete as required
Meter
Description of work
Earth work in excavation in foundation trenches or drains(not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
All kinds of soil
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth: consolidating each deposited layer by ramming and watering lead
Supplying and filling in plinth with local sand under floors,including watering, ramming, consolidating and dressing complete.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:3:6 (1 Cement: 3 coarse sand:6 graded stone aggregate 20 mm cum nominal size
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana /Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate /retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.
All works up to plinth level
Centering and shuttering including strutting, propping etc. and removal of form for :
Foundations, footings, bases of columns etc. for mass concrete.
Steel reinforcement for R.C.C. work including straightening,cutting, bending, placing in position and binding all complete upto plinth level
Thermo-Mechanically Treated bars TMTC-500-8mm dia.
Thermo-Mechanically Treated bars TMTC-500-10mm dia.
Thermo-Mechanically Treated bars TMTC-500-12mm dia
Thermo-Mechanically Treated bars TMT Fe-500-16mrn dia.
Steel work welded in built up sections/framed work including cutting hoisting, rixing in position and applying a priming coat of approved steel primer using structural steel, etc. as required. In gratings, frames, guard bar, ladders, railings, brackts. gates & similar works.
Supply of Galvanised steel birbed wire.
Providing and fixing in position collapsible steel shutters with vertical channes 20x10x2 mm and braced with flat iron diagonals 20x5 mm size with top and bottom rail of T-tron 40x40x6 mm with 40 mm dia steel pulleys complete with bots.nuts locking arrangement stoppers handies including applying a priming coat of approved steel primer.
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge.
Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge.
With material conforming to Grade-III (size range 26.5 mm to 0.075 mm ) having CBR Value-20
Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved s;ze, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.
Providing and fixing on wall face unplastidsed-PVC(working pressure 4 kgf per sqm) rain water pipes conforming to IS :4985 including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion.
Painting with ready mixed paint of approved brand and manufacture in all shades to give an even shade:
Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance ?85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm ) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade:
Providing and fixing retro reflective signboard MS square pipe frame structure ACP sheet pasting Retro reflector fitting and labour cost, size - 20 fit x 1.5 fit
Providing and fixing ACP Retro Reflective Board Gate No Size - 2 fit x 1.5
Making 25cm (10") dia bore upto 4mtr depth below ground with hand auger of approved quality inordinary soil (video classification of soil item A) true to plum band without eccentri city in any stage of operation and disposal of the excavate dearth upto50mtr ,Leadind iluding all lifts,all complete as per approved disign and direction of E/l Details of cost for 4 piles of 4m =16mtrs depth )
Providing and laying autoclaved aerated cement block smasonry with 150mm/230mm/300mm thick AAC blocks in super structure above plinth level upto floorV leve lwith RCC band at sill leveland lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).
1:6(1 cement: 6 coarse sand)
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade:
Providing, Designing, Engineering, Patterning, Fabrication, Supplying and installation of Architectural Membrane, Assembling, Hoisting, Erecting and placing in position MS built-up section/Tubular structure frame work using MS plates of variable thickness confirming to Is 2062 (Grade YST 240) and Tubular structure made from Steel hollow sections, ISl marked confirming IS 1161/4923 (Grade YST 240) in the profile and including necessary foundation bolts & base plates. Fabrication of structural elements shall be done using AW/MAW/MIG welding process. In the profile shape as per drawings with special plate connector, pinion joints, plates, hollow sections etc. with cleaning the surface and including Preparation of detailed rchitectural Membraneation and erection drawings of Structural steel work from design, drawings issued by Engineer-In-Charge and incorporation of Engineer-in-Charge's comment on same, transportation from Architectural Membrane yard, cutting, threading, machining, leads and lifts up to all heights, tools and plants and necessary scaffolding etc. required for all operations involved to make structure of Architectural Membrane shade. All members shall be hot finished welded type tubes.
VRV/VRF outdoor AC unit:- Supply installation testing and commissioning of VRV /VRF /MRV outdoor units with following multiple inverter based scroll type compressors, electronic expansion valve, R 410A/ecofriendly green refrigerant, cooling & heating mode both options, special pre-coated fin type heat exchanger, low noise direct driven propeller condenser fans in each module with top discharge including internal wiring, microprocessor controls, safety. The condensing unit should be capable of providing cooling between +/- 5deg. C. to 48 deg. C & heating within O deg. C to 15 deg. C, COP not less than 3.3. complete as per specification. Outdoor/indoor units should be of same make (brand}. (Single phase/three phase}
VRF/VRV indoor AC unit (high static ductable) :-Supply, installation, testing and commissioning of high static ductable type comprising of copper evaporator, electronic expansion valve, blower, motor, filter pad, with inbuilt drain pump including internal wiring, controls with cordless remote.(Single phase/three phase)
Y joints:- Supply, installation, testing & commissioning of ref nut/Y-joints brass for indoor and outdoor units of suitable size as per requirement,
Outdoor stand fabrication :- Supply, fabrication and erection of angle/channel/flat iron stand, hanging arrangement for air conditioning machines & ducts etc, back /support clamps or other similar work etc. including nut bolts of required size, making holes, fabrication, welding, cutting, etc. and painting with one coat of red oxide paint & two coat of enamel paint as required as per specification.
Drain piping :-· Providing and fixing of CPVC, 6Kg/cm2 drain water piping with fittings, support and insulated with 6 mm thick closed cell elastomeric nitrile rubber insulation complete as per specification.
Meter
Meter
Meter
Copper piping: - Supply, installation, testing and commissioning of interconnecting copper refrigerant pipe work (19mm/13mm thick) duly insulated with elastomeric nitrile rubber type tubular insulation between indoor & outdoor units as per specifications. And exposed piping should be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection.Joints shall be be covered with nitrile rubber tape of 3 mm thick complete as per specification.
Meter
Meter
Meter
Meter
Meter
Control cable: - Supply and laying, testing & commissioning of following sizes of shielded copper conductor Communication cables on existing tray including fixing clamps & proper connections to equipment etc. complete as required.
Refrigerant:Supply and additional refrigerant charge of refrigerant R410/410A & equivalent Eco friendly green gas to compensate the additional piping done at site for all systems including testing commissioning as required.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.
Metre
Metre
Wiring for light/ power plug with 2 X 4 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit along with 1 Nos 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
Supplying and fixing following modula'r switch/ socket on the existing modular plate & switch box including connections but excluding modular plate.etc. as required.
Supply and fixing of following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required.
Supplying and fixing following way, vertical type three pole & neutral, sheet steel, MCB distribution board, 415V, on surface/ recces , complete with tinned copper bus bar, neutral bus bar, earth bar, din bar interconnections, powder painted including earthing etc. as required (But without mccb and incomer) as required' (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
Supplying & fixing following rating 240/415 volts 10 kA, C curve Miniature Circuit Breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying & fixing following rating 240/415 volts 36 kA, C curve MCCB suitable for inductive loads of following poles in the existing MCCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing recess mounted 36 watt LED flat panel (2' X 2') with minimum efficacy 100 lm/w which privides soft light and glare free symmetrical illumination suitable for armstrong/grid ceiling and integrated electronic driver etc directly on false ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required.
Supplyiing, installation, testing and Commissioning of IP at its core with IP switching technology and 100% non blocking communication system with 04 Port Voicemail, 04 Port FXS, 04 Port FXO, 1 PRI Trunk lines (30 Channels) Circuit with CLIP Facility, min 100 IP users License with provision for further additions, 100 analog users, 01 Number IP based Operator Console, 45 Party Conference, Speed Dial, Music on Hold, Internal/ External ring difference, Call Barring, Call Pickup. The system should be redundant which offer 100% duplication of power supply and CPU card and to match the hybrid IP-PBX as per technical specification including supporting accessories etc complete as required. The system should have valid(1pair of 60 set)
Supplying and drawing 20 Pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC Conduit etc. complete as required.
Software for Web based Access Control System Supplying, Installation, Testing and Commissioning of Web based Access Control Enrolment and Device Configuration Software, Should be independent of OS (Windows), Unified Management of Biometric, Card, and Controllers, Import Functionality for bulk user details, Biometric Template Retrieval for Data Recovery, User Management, Logs and Terminal Management, Support for IP-based and USB Biometric Devices, User-specific Access Policies, Different User Policies on the Same Terminal, Assignment of Specific Access Schedules, Pushing Users to Terminals or Groups, Admin Authority Management to define rights of each user to perform, Blacklist User Management, Access Schedule Creation, Real-Time Log Retrieval, Real- Time User Identification, Secure Storage of Biometric/Users Data,Capable to integrate with 3rd party applications overWeb API's, MQTT protocol support
SITC of 24 Port Manageable Distribution Switch with 12 × 10G SFP+ ports; 12× 10G-T RJ-45 Ports / 12× 10G-T RJ-45 line, with 2 Ports Uplink 2 × 10G-T 40G QSFP+ and dual hotswap PSU bays, Premium L3 License for 3 Years, Warranty: 3 year from Day 1. Make: CISCO, Product – C9300X-24Y-A
SITC of 24 Port POE Access Switch 10/100/1000T stackable L2 switch with 4× SFP+ ports and single fixed power supplies, 1 meter SFP+ direct attach Stack cable; 3 year OEM Warranty from Day 1. Make: CISCO, Product – C9200L-24P-4X-E
SITC of Multi Mode 10G-Base-SR SFP+ module; Make: CISCO, Product – SFP-10G-SR=
Providing, fixing, terminating and testing of Modular of 24 port unshielded I/O SC type with required blanking plates. Make: Legrand
Providing, fixing, fitting, connecting and testing of SCLU duplex cords MM OS1/OS2 OM3 50/125um 2 Mtrs Length PC. Make: Legrand
Providing, fixing, fitting, connecting and testing of SCLU duplex cords MM OS1/OS2 OM3 50/125um 2 Mtrs Length PC. Make: Legrand
SITC of CCTV Network Video Management cum Recording Server in N+1 configuration as per Offered Solution with The main servers will be Intel Xeon processor or better, minimum speed of 2.3 GHz with Quad Core, Dual Gigabit Ethernet Port, USB port, Video port.With Server: Recording-Intel Xeon Silver 4210R, 2.4GHz, 32GB, 16TB-05 Nos.The server memory is be 16 GB DDR4 RAM with operation and Video Consumption management Licenses to manage at least 1200 Cameras. With Recording Lisc.+ N+1 Lifetime for 233 Camera. Make- Honeywell & Lenovo , Product- Maxpro NVR & SR650V2
42 U floor mount Rack: Supply of Fully Loaded 42 U 19" floor mount networking cabinet 800*1000 Rack with all required accessories - 4 Nos. of Fan, 16A 10 Plug PDU-2 Nos., Cable Manager-8 Nos., Mounting Screws-200 Pcs. - 42UX800Wx1000D, MCAB BT 42U810 A - Moducab Networking - 42U - 800W - 1000, MCAB GDR BT 42U8 CAM Moducab Front Glass Door - 42U - 800W - Cam Lock - Ventilation - Black Fine Tex. Assembly, 3 INCH CASTOR SET FOR MCAB D3 Inch Castor Set Modu Cab, FOUR Fan For MCAB/Prof -Four Fan For Mcab/ProTek FS, MONITOR TRAY BT 6X700 A- Monitor Tray - Ventilation - 495W - 700D - Black Fine Tex. Assembly, CABLE MNG PLOOP BT 1U A - Metal Cable Manager - 01 U - Plastic Cable Loop's Mountable - Black Fine Tex. Assembly, PDU 16A 10SKT MCB PLG A - Power Distribution Unit - 06/16 Amp Indian-Standard/ Current 16 Amp 3 Pin Plug with Power Cable 2.5 sq.mm 3 meter Length - Mounting Hole / Screw Mountable / 16 Amp MCB / Alternating Hardware Cable 5 Sq. mm Ti meter length PDU 1.6 Mtr Pin Plug with Power Cable 2.5 sq.mm 3 meter Length - Assembly, HARDWARE PKT 20SET - Mounting Hardware Packet ( Containing 10 Nos Each Of 3 ) - 20 Set , Cost of Floor Mount 42U Rack. Make - Legrand
SITC for UTP Cat. 6A patch panels equipped with 24 RJ 45 connectors 19" panel – 1 U Equipped with 4 cassettes of 6 pre-fitted Cat. 6A LCS³ RJ 45 connectors, Automatic cassette removal by simple pressure, Each connector terminates, recommended individually, T568A and B marking with colour codes, Equipped with rear cable guide to hold cables during maintenance, Supplied with coloured labels, Compliant with ISO/IEC 11 801, EN 50173 and ANSI/TIA 568 standards, Flat panels, 24 RJ 45 connectors – 1U. Suitable for UTP. Equipped with new-generation Quick-Fix for automatic (screwless) mounting on enclosure and cabinet uprights, Universal mounting on all cabinets or enclosures, Panels ensure automatic earthing of each connector, equipped with 4 bundles guides fixed at the rear.Make – Legrand
Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range: -5° to +60°C, Bending Radius: < 4 X Cable Diameter at -5°C ± 1°C and Pulling Force : 11.5Kg etc. complete as required
Meter
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
LETTER FOR CHARACTER CERTIFICATE (1).pdf
NIT • 0.30 MB
LETTER NO. 3284 DT. 05.05.2009.pdf
NIT • 0.29 MB
letterno7291.pdf
NIT • 0.55 MB
Letterno7292.pdf
NIT • 0.64 MB
Tender Check List.pdf
NIT • 1.76 MB
BOQ.xlsx
NIT • 0.03 MB
SBD Extra Work BPP Retender.doc
NIT • 0.62 MB
ETender NIT 01.pdf
NIT • 1.34 MB
PAPER CUTTING.pdf
NIT • 0.42 MB
BOQ.xlsx
NIT • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .