Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
18 Jul 2026, 9:30 pm
Karnataka State Seeds Corporation Ltd
Providing 250 KVA HT Transformer, HT Metering Cubicle, LTUG Cable, Poles, wiring
KSSCL/2026-27/EL/WORK_INDENT21/CALL-2
KSSCL/2026-27/EL/WORK_INDENT21/CALL-2
Open
Electrical
KSSCL Head Office Bengaluru
4 documents required · 0 mandatory · 4 optional
Department Registration Details
Total value of civl engineering works executed and payments received in the last five years (year-wise)
List of existing commitments and ongoing work
List of works for which tenders already submitted
Banker Details
The bidder should put work done certificate for each electrical work separately
class 1 electrical liscense
valid esi certificate
valid pf certificate certificate
last three month paid challans
last three month paid challans
labour certificate
Transformer 250 KVA 1 no, 11 KV HT Metering Cubicle Station 1no, LTUG Cable 100 mtrs, wiring 500 mtrs, fencing 30 sqmtr pole 5 nos
last 5 years turnover
annual turnover certificate
original work done certificate
The Bidder participating in the above tender must upload the specified brands to be installed failing with the tender is liable to be rejected
other document as per mentioned in tender notification & Tender Document
₹500
₹50,000
4 Jul 2026
4 Jul 2026
20 Jul 2026
10 Jul 2026
supplying RCC pole 9Mtr long 150 KG WL (dwgNo bescom/ gm/QS&S /02-dtd 24/11/2018as per TS 785 ( Pno 3 Item No 2/1.02) material code 200106
Digging of Pit 1.8 Mtr depth for errection of 9 to 10 Mtr Long Steel/RCC/PSCC supports as per approved Drawing ( P no 43 Item no 2.1.1.2) IN hard soil
Erection of RCC/PSCC Pole of 9 to 10 Mtr long in a pit of 1.8 Mtr depth( Pno44 Item No 30.2.02)
supplying pre strussed tubler spun pole 11Mtr long 500KG WL (dwgNo bescom/gm/QS&S /45-dtd 24/11/2018as per 13158:1991) ( Pno 3 Item No 7/1.07)material code 200120
Digging of Pit 2.2 Mtr depth for erection of 11 Mtr Long RCC/PSCC supports as per approved Drawing
Erection of PSCC Pole 11 Mtr Long 365 Kg WL in a pit of 2.2 Mtr depth
11 kV, Horizontal Cross Arm - Mild Steel (MS) (Dwg No. BESCOM/GM/QS&S/04 Dtd 24.11.2018 Material code 279020
11 kV, Horizon tal Cross Arm - Galvanised Iron (GI) Material code 220020
11 kV, Special 3 Pin Cross Arm - MS(Dwg No. BESCOM/GM/ QS&S/03 Dtd 24.11.2018) Material code 279013
11 kV, Special 3 Pin Cross Arm - GI (Pno 3/14.2.04)Material code 280013
LT 4 Pin Cross Arm - GI ( Pno 4 Item no 16.2.06)Material code 280014
Fixing of V-Shape/Horizontal cross arm including Single Top Support Brace and Insulator fixing
LT ST Support 50x6 mm Flat - GIMaterial code 280091
HT ST Support 50x8 mm Flat - MS (Dwg No. BESCOM /GM/ QS &S /04 Dtd 24.11.2018) Material code 279092
Fixing of HT/LT Single Top Support( P no 45 Item No 54.5.06)
Spiral Earth Electrode ( Pno 4 Item no 26.2.16) Item code 281683
Fixing of Earth Guard Stirrup( Pno 45 Item No 55.5.07)
11 kV, Cross Arm with HT Top Support (glass reinforced ( Pno 4 Iten No 27.2.01) Material code 279090
Fixing of HT/LT Single Top Support( P no 45 Item No 54.5.06)
RCC Pole Clamp - MS(Dwg No. BESCOM/GM/QS&S/30 Dtd 24.11.2018) ( Pno 4 Item No 31.5.01) Material code 279523
Fixing of 4 Pin double cross arm including Brace and Insulator
GUY set complete natrerial ( Pno 5 Item No 39 to 46 total 8 Items Mterial code 279650
Fixing of GUY Set with break insulator making use of 7/3.15 mm (7/10 SWG) galvanised steel wire with turn buckle and anchoring arrangement as per approved drawing. (Excluding excavation of PIT)
11 kV Ceramic Pin Insulator (Shell only)11 kV GI Pin for 11 kV Ceramic Shell InsulatorMaterial code 283005
11 kV GI Pin for 11 kV Ceramic Shell InsulatorMaterial code 283040
Rabbit ACSR (6/3.35 mm Al + 1/3.35 mm St), Std Wt: 214 Kg/KM Material code 284108
Stringing of Conductor (including pin binding, providing jumps, dead ending, etc.,( Pno 46 Item No 67.7.04)
8 SWG GI Wire(4.064 mm Dia), Std Wt: 131 Kg/KM Material code 281008
Distribution Transformer 250 KVA- 3 Phase, 11kV/433V - Stacked (CRGO) losses confirming to 5 Star rating as per IS-11171 Core with Oil as per IS-1180 (Part-1): 2014 CABLE ENTRY TYPE( Pno7 Item No113.13.09)
Erection of Transformer & StructuresErection of 200 - 250 kVA Transformer
LT Protection Kit (Dwg No. BESCOM/GM/QS&S/10 Dtd 24.11.2018)( Pno 9 Item No 133.17.01) Material code 301107
LT Distribution Box for 250 kVA DTC with MCCB's (Sheet Metal) Dwg No. BESCOM/GM/QS&S/08 Dtd 24.11.2018) Material code 301056
Fixing LT Distribution box for 100/250/500 kVA DTC (Excluding wiring) ( Pno 47 Item No 84.9.07)
LT Distribution Box for 100/250 kVA DTC with MCCB's (SMC) Material code 301060
10 kV, 5 kA Lightning Arrester Polymeric type with ground disconnector ( Pno 9 Item No 138.19.02) Material code 302002
11 kV, HG Fuse Unit with Solid Core Insulator (Dwg No. BESCOM/GM/QS&S/21 Dtd 24.11.2018)
11 kV, 400 Amps DoubleBreakGOS(DwgNoBESCOM/GM/QS&S/22 Dtd 24.11.2018) Material code 280100
DP Set (2 Pole Strucrure Kit) as per IS-1977For RCC Pole - 9 Mtr Long, 145KG WL/PSCC Pole - 9Mtr long 300KG WL -GI Material code 2800100
Erection of Double Pole Transformer Structure using 9 Mtr Long RCC (145 Kg WL)/PSCC (300 Kg WL) Pole including fixing Structure Materials, Erection of Poles etc., complete for mounting of Transformer as per approved drawing( P no 44 Item No 39.3.02)
1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-709Part-1, Armouring strip thickness and resistivity as per I3975(185Sqmm, 3.5 Core, (25 GI Strips - 4 x 0.8 mm) Material code 287214
1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-709Part-1, Armouring strip thickness and resistivity as per I3975(95Sqmm, 4 Core, (17 GI Strips - 4 x 0.8 mm) Material code 287212
Transporting Cable from Store to work spot including loading and unloading (including Crane and other equipment charges if any)( P no ( P no 51 / 163.01)
Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed.
11 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as perIS7098(Part2)Armouring wires dia and Resistivity as per IS-3975 Material code 287400( 95 Sqmm, (54 GI Wires - 2.5 mm Dia)
Transporting Cable from Store to work spot including loading and unloading (including Crane and other equipment charges if any)( P no ( P no 51 / 163.01)
Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff ( Pno 52 Item No 170/21.01)
Heat Shrinkable Indoor Type Cable Termination Kit for PILC Cable3x95 Sqmm Material code 288332
Heat Shrinkable Outdoor Type Cable Termination Kit for XLPE Cable3x95 Sqmm Material code 288332
Making and Fixing pot head for HT Cable onlyHeat shrinkable Type Terminations3x95 to 3x150 Sqmm
11 kV HT Metering cubicle of different CT Ratio, Both side cable entry type with 3 CT & 3 PT, With Transparent Cover TTB, with 30x8 mm Copper Busbar, Modem & 2 No of Meters for 3 Phase 4 Wire Metering without Load Break Switch (HT Metering Box Fabricated out of 3 mm MS Sheet duly epoxy powder coated) as per revised Specification(Dwg No. BESCOM/GM/QS&S/-- Dtd 24.11.2018)Material code 358351
11 KVA load breake switch with HT cable incoming and outgoing arrangements ( PNo 17 Item no 40.01) Material code 506492
Erection of HT metering Cubicle on Platform.( PNo 47 Item No 78/9.01)
GI Pipe B - Class as per IS-GI Pipe - 50 mm Dia( P no 45 Item No 48.04) Material code 768044
HDPE/PLB Pipe 50/42 mm (Pno 30 Item No 536/66.04)Material code 286003
Jelly Spreading (20-25 mm) : Supplying and providing jelly in thestation yard of uniform thickness of 100 mm including the cost of materials, labour charges, required tools and plants etc., complete. Work shall be carried out as per the instructions of Engineerin-charge of works as per the standard procedure.(P no 158 Item No 1)
Spreading of Stone Dust : Supplying and providing stone dust in the station yard or wherever required including watering, ramming, consolidating and dressing. The rate includes the cost of material, labour charges, required tools and plants etc., complete. Work shall be carried out as per the instructions of Engineer-in-charge of works as per the standard procedure.(P no 158 Item No 2) .
transformer , metering , LBS box provided foundation taken KPWD civil SR
transformer sub station fencing taken using 6 SWG GI chain link fencing with 2100mm x 40 mm x 4 mm thick squire tube including cwelding digging of holes in soil with GI bolt & nuts etc
fabricating supplying and mounting MS box made out 14 SWG suitable for flour/ wall mounting fully weather proof with provision for better heat dissipation , provided with hinged front cover equipment with tamper proof locking arrangements with suitable size c1a with neccessory cable entry pipe with gland and box should be finished with 7 tanks treatment with powder coated paint and finaly finshed with approved color etc , complete
supplying and fixing angle iron angle iron frame work fabricated out of M.S angle iron and M.S flat … with bolts nuts washers etc and painted with 2 coats of approved paints SIZE 50X50X6MM
SUPPLYING 250 A 4x30x10 mm aliminium strips A rated 3 phase with nuetral busbar using required capacity electrolytic aliminium strips coverd with heat shrinkable coloured PVC sleave mounted on phenolic /FRP/DMC insulator in existing panel board the bus bar shall have suitable holes for termination of the incoming and out going cables as per IS specification with neccessory bolts , nuts and washers etc ( P no 20 ,Item No, 5.40.2) size 250A
supplying and fixing moulded case circuit breaker (MCCB)over the existing wood /panel board using neccessory screws bolt,nuts neccessory phase temprature hnadle and wiring complete .protection of over load and short circuit in thermal magnetic release micro proccessor release shall have earth fault as per IS-13947 ( 1cu=100% 1cs in 4 pole MCCB . mccb shall be provided with double insulation between front contacts to avoid any accident contact with live current carrying with path with the front cover open multi pole breakers shall be designed to break all the poles and they shall have single mechanism (P no 16&17 Item No 5.14.9) capacity FOUR POLE 160 A 25 KA
APFCR PANEL Supplying fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase 400/440 volts gradefor power factor improvement of rotating machineries like induction motor Make:Trinity/Schneider( Page no-19 Item no-5.37)
Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C type curve indicator ON/OFF energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60899 6-32Amps TPN Make:Schneider/Siemen/ABB/Equillvalant (Page no-17 Item no-5.18.7)
Supplying and fixing Power contactor with NO/OFF contactor on existing wood/Panel boards using necessary bolts nuts washers and wiring etc complete with AC-3 Rating and as IS-13947 22- 25 Amps Make:Schneider/Siemen/ABB/Equillvalant
supplying fixing and wiring automatic power factror controler circuit fully static unit control by by 14 stage microprosser operatorrelyas LED display self programing functionfor power stagesand operating logic checking facility for healthy efficiant of each indivitialcapacitor bank measurenebt of network hormonics with indication whih limit values are exceeded comprehensive display with large three phase LED display long term memory for setting protection for over voltage . power factor cerrection fault and no voltage to connect /disconnect banks with automatic recognition and with standerd program
supplying and fixing LED type panel board indicating lamp with required colour suitable for 230440VAC 50Hz 12/24V DC
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V Grade multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring as per IS-694:1990 and confirming to GTP of GROUP-A. 1.0 sqmm Make:polycab/RR Cable/KEI/Finolex wincap/Equilvalent(Page no-5 Item no-2.3.3/2.3.6 /) 2.5 sq mm / for control wiring
6 sq mm / for control wiring
b. 25 x 3 mm Copper strip.
supplying and crimping copper end terminal (LUG) ( P no 20 item no - 63.01/63.4) 25 sq mm
brass cable gland ( Pno 25 ,I, 689-70.02) size 32 mm
open system supplying heavy guage PVC conduit pipe confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws 19/20 mm dia 2 mm thick ( Pno 2 item no 1.1.2/1.1.3)
25 mm dia 2 mm thick
Supplying and fixing PVC/metal conduit Deep junction box 19/20 mm deep Junction box
25 mm deep Junction box
supplying and wiring adopting loop system in existing PVC conduit /casing caping using 2x1.5 sq mm ( phase & nuetral ) 1x1.0 sq mm ( Earth wire ) FRLS multi strand PVC isulated copper wire ( confirming to IS 694and latest amendments ) without control switch shall be fixed on the existing plastick sheet /gang box the other end of the wires shall be terminated with sufficiant loose length in awood/PVC round block complete for the each conduit Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box
Two outlet in arow above 3 mtr upto 6 mtr from the tapping point to outlet via switch
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694-2010 1.5 sq mm
Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs,Machine/NF screws etc., complete. 10 -12 way
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the10-12 module
18 module
Supplying and fixing of modular switch & connected accessories onexisting modular switch plate as per IS 3854 and IS 1293.6A one way switch
18 module
Supplying and fixing of modular switch & connected accessories onexisting modular switch plate as per IS 3854 and IS 1293.6A one way switch
6 A two way switch
Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. )6 A backlite cieling rose
pendent holder
batten holder
Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS encloser 12 way SP& N double door
Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required6 6 to 32 A SP MCB (P no ,17 item no 5.18.1/5.18.4/5.18.7)
6 to 32 A DP MCB
6 to 32 A TP& N
supplying ... feet PVC batten with integrated LED tube ... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI > 80. Power Input: 220- 240V@ 50/60Hz & Power factor >0.9 along with CE approved . 2 years Warranty against defect working under standard electrical condition18-20 W (P no 43 item no 11.2.2 )
Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior LED Floodlight 100W(P no 46 item no 11.9.2 )
Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT > 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire > IK08. Power Factor >0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole LED Streetlight 40W ( P no 45 Item No 11.6.4)
Supplying and Fixing of mm dia class A GI pipe bracket upto 2 ms long bent at suitable angle and fixing to this bracket street light fitting of all capacities to GI or GI or rail or RCC pole / wall using suitable clamps, bolts, and nuts and wiring using suitable capacity wires.( P no 56 Item No 13.1.12
Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiringusing suitable capacity wir (P no 56 item no 13.5 )
supplying and fixing wiring Earth electrode for grounding of lifts , transformers ,, DG sets etc using 40 mm dia 2.9mm thick 2.5M long GI pipe with GI funel with mesh and suitable size reducer fixed on the top of earth electrode the funnel should be enclosed in a CC chamber of 400x400x400 with cast iron cover the eaerth electrode shall have stagered hile of 12 mm dia and the electrode should be coverd 150 mm all-round with alternate layers of salt and charcoal from the bottom of CC chamber the connection from the electrode is to be established though GI strips using GI bolts and nuts .(P no 54 item no 12.57 )
Supply and laying of following size Copper / GI strip including all fixing accessories for inside the building with all necessary interconnections with earth station and equipments. The cost shall also include the supply & installation of Heat Shrinkable PVC colored sleeves. end terminated with suitable copper lugs ,copper fixing hardware's,etc..25 x 3 mm GI tape (P no 54 item no 12.57 )
Sanctioning 100 KVA power supply with LT to HT convertion with allied work at RONA under- Self Execution
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
tender notification.docx
Instructions to Tenderers • 0.04 MB
Rona-elec-dts.doc
Tender Document • 0.93 MB
estimate.xls
Commercial Information / Worksheet • 0.08 MB
Download all tender documents and submit your bid