Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.9 LAccepted-AOC 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L1 | Accepted-AOC Accepted due to L1 | |
| 2 | L2₹10.1 L+₹1.1 L (12.5%)Rejected-AOC | L2 | Rejected-AOC Higher rate | |
| 3 | L3₹10.5 L+₹1.5 L (16.4%)Rejected-AOC PLOT NO 26 1ST FLOOR PRATAP NAGAR NEAR JAIL ROAD NEW DELHI 110064 | NEW DELHI | NEW DELHI | DELHI | 110064 | L3 | Rejected-AOC Higher rate | |
| 4 | L4₹11.0 L+₹2.0 L (22.8%)Rejected-AOC | L4 | Rejected-AOC Higher rate | |
| 5 | L5₹12.0 L+₹3.0 L (33.5%)Rejected-AOC TP 117 2ND FLOOR MAURYA ENCLAVE PITAMPURA DELHI 110034 | DELHI | DELHI | DELHI | 110034 | L5 | Rejected-AOC Higher rate |
Tender Value
₹13 L
EMD Value
₹26,000
Closing Date
8 Jan 2020, 6:00 pmClosed
GE New Delhi
GE NEW DELHI ARMY HOSPITAL R AND R COMPLEX RAO TULA RAM MARG DELHI CANTT 10
ADDN/ ALTN TO RCC JALLIES, RAILING IN FRONT OF HQ IDS INCL SPL REP FALSE CEILING, FLOORING, WALL PANELING AND CUPBOARDS TO ROOM NO 34 OF SOUTH HUTMENTS OF HQ IDS AND DRAINAGE AREA, CABLE DUCT AND CHEQURRED TILES IN REAR SIDE OF MAIN BLDG OF HQ I
2019_MES_298302_1
GE/ND-60/2019-20
Open Tender
Civil Works
Item Rate
270 days
GE New Delhi
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE NEW DELHI
₹26,000
Yes
3 Mar 2020
11 Dec 2019
10 Jan 2020
11 Dec 2019
8 Jan 2020
25 Dec 2019
Amount
Dismantling wall & ceiling boards incl frame of any description as in panelling ceiling, partition, cub boards etc incl cover fillets in any surfaces complete
S&F prelaminated PVC rigid foam sheet wall panelling of 5 mm thick stuck on inner frame work of 35 mm wide strips of 5 mm thick rigid foam sheet. The strips should have a groove of 6 mm width and 2 mm depth for sinking the head of screw used to fix the strips to the all and should be placed vertically at equal intervals of 300 mm C/C. The PVC strips to be fixed to the all using 65 mm long MS screws through the groove in the strip by using PVC fasters. Note : (a) Work for fixing of wall panelling shall be got executed through manufacturers authorised applicators only under the close supervision of their technical staff. (b) The entire qty of wall panelling and their allied ancillaries shall be procured directly from the manufacturer or their authorised dealer only.
M&L for GI powder coated micro preforated micro look false ceiling with fleece lay- in- type 0.50mm thick, suitable for grid/frame module of 600mmx600mm size complete with GI powder coated grid consisting of silhouette main T runner 15mm suspended at 1200mm centre to centre and cross T runner of 15mm size suspended at 600mm centre to centre suspended by 4mm GI rod from roof slab including steel fastner wall angle and T with interlocking arrangement as required for framing grid suitable for module size 600x600mm ceiling etc complete all as per specification and directed Make : armstrong/hunterduglas
Dismantling floor hearth or wall tiling including cement mortar bedding and removing rubbish of the premises complete in all respect and all as specified.
M&L Vitrified coloured floor tiles of 1st quality light shade, 10mm thick (square/rectangular) polished, conforming to ISO:13006 classified under group B1a of international stranded, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over screed bed or bedding layer in cement mortar 1:6, 15 mm thick for laying floor finishes.
Taking down cement plaster on brick wall surfaces including racking out joints hacking for key scrubbing down with water etc and removing the rubbish out of Mod Land
M&L for 15 mm thick rendering fair/unfair faces of brick work on concrete surfaces finishing even and smooth without using extra cement in CM 1:6 on walls
Taking down chowkhats or frame without taking off shutters exc 1.50 sqm but n.exc 4.00 sqm
Taking down chowkhats or frame without taking off shutters n. exc 1.50 sqm
S&F powder coated aluminium door incl frame using 96.6mm X 44.8 mm X 1.6 mm aluminium chowkhats 84.0 x44.7mmX1.6mm section vertical styles 101.60X44.88X1.6mm rails mounted on floor spring mortice lock vertical type mild steel 100 mm size (Make Godrej/Harrison) including aluminium powder coated builders hardware 02 Nos tower bolt 150 mm , sliding bolt 300 mm long 01 No, door handles and fittings complete all as specified and directed by Engr-in-Charge bottom panel with 12 mm thick laminated Novapan and top panel with 5.5 mm thick plain/colour glass fixed with snap beading /rubber gasket of suitable size and each shutter n.exc 0.95 mtr in width. Make of glass:-MODI/ FLOAT/ ATUL
S&F powder coated aluminium window incl frame using 63 mm X 38 mm X 1.6 mm chowkhats with 48mm X 48 mm X 1.6mm openable section as in shutter including ornamental aluminium grill 8 mm dia, 75 X 95 mm aperture, 5.5 mm thick glass panes of approved make with rubber for fixing glass and including builders hardware such as aluminium handles 100 mm -02 Nos, tower bolts 100 mm 02 Nos, butt hinges SS 100 mm 04 Nos etc complete all a specified and directed by Engr-in-Charge
Dismantling boarding any descriptin , fixed in any position with screws
S&F 18mm thick MDF board pre laminated both side fixed with screws as in storage cabinet/cub board and built in modular tables etc incl 75 mm size brass tower bolts, magnet catcher , brass hasp and staple 75 mm brass piano hinges 30 mm, brass mortice lock 65 mm two lever (Godrej) and hole cap incl lipping etc and sliding rail complete all as directed by Engr-in-Charge
S&F 100 mm wide Venetian blinds vertical type incl guide rail, pulling thread etc incl taking down existing pelmets/venetian blinds complete all a specified and directed by Engr-in-Charge. Make :-Wintree or its equivalent.
Demolition of cement concrete in ground floor and pavings n.exc 15 cm in thickness below or above ground level & removing the rubbish out of MOD land kashmir house premises
Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete.
M&L for brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radious built in cement mortar 1:6 old size bricks
M&L for brick work using except bricks (old retrived bricks from demolition shall be used ) straight or curved on plan exc 6 m mean radious built in cement mortar 1:6 old size bricks
M&L Cement concrete 1:2:4 type B-2 using 40 mm agg as in surface channel of drain complete all as specified & directed incl formwork etc.
M&L providing cement concrete 1:2:4, type B-1 in lintels upto 1.5 mtr clear span , cills,steps, seismic and other siesmic and other similar bands plinth course, string course , coping etc and like including weathering , slightly rounded or chamfered angles and throating, using crushed graded stone aggregate complete all as specified & directed incl formwork etc.
Dismantalling wrought or mild steel work including of any description not otherwise provided for complete all as specified & directed .
M&L MS gusssets plates (plane or chequerred ) channel channel square cut or notched (ordinary or counter sunk ) forming holes, with out attachment grade Fe -410 W( Gde E-250 Quality A) complete all as specified & directed .
M&L 75 mm thick PCC Subbase type C2 1:3:6 (40 mm graded aggregate) as in sub base floors pavings etc all as directed by Engr-in-charge
M&L for PU coated machine pressed precast conctete paver block of approved colour, shape and size conforming to IS 15658-2006 of 80 mm thickness M-40 Grade in any tint, as in floors/pavings laid over and including 40 mm thick sand cushioning layer and proper filling the joints with sand and compacting with plate vibrator complete as per IRC SP 63-2004 complete in all respect and all as specified.
M&L precast cement concrete in landings, drain cover slab,etc with plain faces 1:2:4 type B-1 using 20 mm graded stone agg and set in CM 1:4 complete all as specified & directed .
M<MT bar 10 mm dia and over cut to length bent to shape required including cranking bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire(annealed) not less than 0.9mm dia or securing with clips complete .
M&L 15 mm thick rendering on fair/unfair faces of brick work or concrete surfaces in cm 1:4 in cement finishing even and smooth without using extra cement on walls.
M&L Preparation of undecorated brick /concrete plastered /un-plastered or newly plastered surfaces of walls, Pillars, cornices etc by booming down with steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts oil and greasy spots and applying two coats of weather coat for external walls painting by Apex Ultima from Asian Paints or Shield max from Dulux weather proof over a coat of solvent based primer complete.
Demolition of RCC Jalli & pillar set in cement mortar complete in all respect and all as specified.
S&F MS framed work such as grills ,gratings, manholes covers etc with ends of bars shouldered or reveted , frame work of water tanks and similar work conf to Fe 410 complete in all respect and all as specified.
S&F red stone or dholpur stone louvers or jalli 35 mm thick of size 600mmX600mm size as approved design and /pattern incl all mouldings rounding ornamental work complete all as directed by engr-in-charge.
S&F red stone or dholpur stone Pillars of 900x100x100 mm size as approved design /pattern incl all mouldings , rounding ornamental work set and jointed in CM (1:4) complete all as directed by Engr in charge
Taking down carefully existing copper /aluminum point wiring (Light, fan, socket or power) complete including fittings and fixtures such as switches ceiling roses socket, regulator etc. and making good disturbed surfaces of walls, floors etc to match with the existing surface/ finishes complete all as specified & directed.
M&L for Point wiring with 1.5 sqmm, single core ,PVC insulated, unsheathed FRLS cable, 1100 volts grade, IS -694 marked, with multi stranded copper conductor and earth continuity copper conductor cable of same size as in phase/neutral and connected to common earth dolly drawn through and including rigid PVC conduit of suitable size alongwith fittings and accessories, fixed /laid/concealed in walls/ceilings including cutting chases and making good to walls, floors etc, and also incl suitable modular bottom sunk type pressed steel terminal box and suitable modular top cover with frame and No of modules for the following : -Make of cable:-Havells/Polycab/RR
One light/fan/bell point controlled by one, one way switch.
One three pin socket outlet 5 Amp controlled by one, one way switch on same board
One three pin socket outlet 5 Amp controlled by one, one way switch on independent board
M&L for Point wiring with 2.5 sqmm, single core ,PVC insulated, unsheathed FRLS cable, 1100 volts grade, IS -694 marked, with multi stranded copper conductor and earth continuity copper conductor cable of 1.5 sqmm connected to common earth dolly drawn through and including rigid PVC conduit of suitable size alongwith fittings and accessories, fixed /laid/concealed in walls/ceilings including cutting chases and making good to walls, floors etc, and also incl suitable modular bottom sunk type pressed steel terminal box and suitable modular top cover with frame and No of modules for 15 Amp socket out let on independent board. Make:-Havells/Polycab/RR
Supply and fix switch modular 6 Amps 1 module 230 Volts one way Make:-Indoasian/Legrand/Anchor
Supply and fix modular switch 1 way 16 Amps 1 module 230 Volts Make:-Indoasian/Legrand/Anchor
Supply and fix modular socket , 6 Amp 2/3 pin combined 230 Volts Make:-Indoasian/Legrand/Anchor
Supply and fix modular socket , 16 Amp 2/3 pin combined 230 Volts Make:-Indoasian/Legrand/Anchor
Supply and fix modular type fan regulator electronic step type 250 Volts single phase 2 module,120 watts connecting suitable for ceiling fan 1200 /1400 mm sweep complete. .Make:-Indoasian/Legrand/Anchor
M&L for taking down ceiling/wall mounted/exhaust fan, after dis-connecting cable end, regulator, dismantling of blades inclding deposit the same at E/M Stroye Yard complete all as specified and directed
S&F in repalcement ceiling fan 1200 mm sweep complete with down rod etc complete all as specified and directed. Make:- Havells Bajaj/ Crompton Graves/ Usha.
S & F in replacement LED Ligtht fitting 34 watts 2x2 Ultra modern recess mounting luminaire suitable for armstrong/grid/POP ceiling complete with separate electronic driver & high brightness SMD LEDs, 34W LED 4000K lamp type. Make:- Havells Cat Part No LHEWEJP7PL1W034 or equivalent in Wipro/Phillips/Bajaj
S & F in replacement LED tube Ligtht fitting 20 watts surface an wall mountednLED batten extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver. Make:- Havells Cat Part No. LHEWEBP5IN1W020 or equivalent in Wipro/Phillips/Bajaj
S&F in replacement sub main wiring with two runs PVC insulated unsheathed FRLS stranded copper conductor cable of size 4 Sqmm alongwith one run of PVC insulated unsheathed stranded copper conductor cable of size 2.5 sqmm as earth wire connected to earth dolly fixed on surface of wall/ceiling/in existing concealed conduits complete all as specified and directed. Make of cable:-Havells/Polycab/RR
Sub main wiring with two single core 6 sqmm copper conductor PVC insulated multistranded unsheathed FRLS cable drawn in and including ISI marked 25 mm dia medium grade PVC conduit concealed in wall surface/ceiling including 4 sqmm PVC insulated unsheathed multistranded copper conductor, FRLS cable as earth wire complete as directed. Make of cable:-Havells/Polycab/RR Note :- Two run of 6 sqmm copper conductor cable,one run of 4 sqmm copper cable and one run of PVC conduit shall be measured as one unit length.
Taking down U/S sub main wiring of any type/size complete all as specified and directed
Supply and fix MCB SP 5 to 30 Amps to KA rupturing capacity, IS-8828 marked. Make:-Havells/Indoasian/Legrand
MCB DBs single pole with neutral sheet metal enclosures double door type, 240 Volts, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete with out MCB and with enclosures blank plate for unused way suitable for 8 way. Make:-Havells/Indoasian/Legrand
MCB SPN 240 Volt of capacity 32 to 60 Amp rating, "B" Series complete all as directed. Make:-Havells/Indoasian/Legrand
S&F sheet metal enclosure 2-in-1 3 pin metalic socket and plug top with plug socket and MCB 20 Amp SP. Make:-Havells/Indoasian/Legrand
M&L for shifting of ACs(indoor and outdoor unit) of any capacity to specified locaton , cutting of roof slab, drawn through and fixed /laid concealed in walls/ceilings, making good to disturbed surface of wall/floor etc to match the existing surface/ finishes all as directed, incl rectification minor defects and make the equipment functional complete all as directed.
Supply and Fixing in replacement of synthetic rubber tube insulation of thickness 9 mm & Internal Diameter - 13 mm (1/2")for refrigerant copper piping of split AC units. Make Supreme/Gulf-o-flex/Superlon.
Supply & charging as top-up of gas refrigerant R-22 or as existing No to split/window type AC up to 2 Ton capacity including removing of leakage if any and testing complete all as specified & directed by Engineer-in-charge
S&F copper tubing heavy duty inner dia 6 mm (1/4") for refrigerant for ACs.
S&F copper tubing heavy duty inner dia 13 mm (1/2") for refrigerant for ACs.
POWER ELECTRONICS ENGINEERS
Shivam Firetech Engineers
B Kumar and Co
GLIBS CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .