Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.1 LAccepted-AOC 225 NAROT COLONY MODEL TOWN PATHANKOT PB 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹34.7 L+₹5.3 L (17.9%)Rejected-Finance B XXIII 56 A PREM NAGAR SAINGARGH PATHANKOT 145001 PUNJAB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹45.6 L+₹16.1 L (54.7%)Rejected-Finance 1ST FLOOR GURJEET MARKET DHANGU ROAD | L3 | Rejected-Finance Not Lowest |
Tender Value
Refer Docs
EMD Value
₹96,000
Closing Date
22 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (SOUTH) PATHANKOT
GE (SOUTH) PATHANKOT
REPAIR MAINT OF LT DISTRIBUTION NETWORK AND MISCELLANEOUS ALLIED WORKS AT DEPOT AND DOMESTIC AREA AT UNCHI BASSI UNDER GE S PATHANKOT
2021_MES_413041_2
GES/PKT/T-55/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (SOUTH) PATHANKOT
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (SOUTH) PATHANKOT
₹96,000
Yes
30 Mar 2021
5 Feb 2021
24 Feb 2021
5 Feb 2021
22 Feb 2021
6 Feb 2021
60 days
Amount
Excavation in trenches in any type of hard/dense soil n exc 1.5 mtr in width and n. exc 1.5 mtr in depth and getting out all as required for laying of cables,Foundation filling of poles or stays and for re-routing of cables.
All as per item No.1here in before but exc 1.5 mtr or part there of in depth beyond 1.5 mtr depth.
Returning filling, in including spreading ,leveling, watering and well ramming in layers not exc 25 cm each all as required.
Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exc 1.5 mtr above the starting point.
M & L for good quality dry sand cushioning to under ground electric cable on layer of 8 cm thick before laying the cable and second layer of 15 cm thick after laying the cable all as specified in clause 19.75 of MES Schedule part-I (2009) Note : Sand shall be fined sand as specifed and punned thickness shall be measured and paid.
Supply and laying sub class 'B' bricks of old size (230x115x75 mm) or of size locally available , laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge
Relaying of old (good quality/unbroken) bricks obtained from ser No 6 above, being laid flat, dry in trenches for cable protection complete all as specified and directed.
Cutting the tarmac / hard standings and excavating in trenches across the road for laying cable including making good the excavated portion by means of PCC 1:3:6, type C1 matching with the surroundings all as directed.
Taking out carefully unserviceable/defective cable up to 95 Sqmm from trenches and relaying same after defect rectification/repairs in same trench or any other indicated location after testing complete all as directed by Engr-in-Charge.( Note: Earth work, sand, bricks will be measured and paid separately)
Supply and laying to wall or poles or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium multistranded conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or strip and overall PVC sheathed 16 sq. mm nominal cross section 2 core in service connections all as required and directed including dismantling old unserviceable cable. (Note : Incl making good all distributed wall surfaces/ flooring/tilling to match with existing specification)
All as per srl item No 10 but cable of size 25 Sqmm 2 core.
All as per srl item No 10 but cable of size 06 Sqmm 2 core.
Supply, laying and testing of LT UG cable, XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of following sizes complete all as specified and directed including dismantling old defective one. Note: Earth work ( Excavation, Returning & refilling and removal), sand cushining , cable protection cover, GI protection pipe shall be measured and paid for seperately under respective item of Sch 'A'
All as per srl item No 13 but cable of size 10 Sqmm 2 core.
All as per srl item No 13 but cable of size 16 Sq mm 4 Core
All as per srl item No 13 but cable of size 25 Sqmm 3.5 core.
All as per srl item No 13 but cable of size 70 Sqmm 3.5 core.
All as per srl item No 13 but cable of size 50 Sq mm 3.5 Core
All as per srl item No 13 but cable of size 35 Sq mm 3.5 Core
All as per srl item No 13 but cable of size 240 Sq mm 3.5 Core
All as per srl item No 13 but cable of size 400 Sq mm 3.5 Core
All as per srl item No 13 but cable of size 185 Sqmm 3.5 core.
S & F in replacement of Cable jointing kit for 1100 volt grade cable for outdoor/indoor termination end joint heat shrinkable type complete with jointing material and accessories suitable for XLPE/PVC armoured aluminium conductor cable of size 16 to 35 Sqmm 3.5/4 core.
All as per item No 23 but for 50 to 95 Sqmm size.
All as per item No 23 but for 120 to 185 Sqmm size.
All as per item No 23 but for 225 to 300 Sqmm size.
All as per item No 23 but for 400 to 500 Sqmm size.
S & F in repacement of Cable jointing kit for 1100 volt grade cable for straight through termination heat shrinkable type complete with jointing material and accessories suitable for XLPE/PVC armoured aluminium conductor cable of size 10 to 16 Sqmm 3.5/4 core.
All as per item No 28 but for 25 to 50 Sqmm size.
All as per item No 28 but for 70 to 150 Sqmm size.
All as per item No 28 but for 185 to 240 Sqmm size.
All as per item No 28 but for 300 to 400 Sqmm size.
Dismantling RCC poles/ struts, any size including transportation and stacking complete all as directed.
Supply and erection in vertical position Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws, type 410 SP-31 (9.00 metres long) all as specified duly factory painted with two coats of black bituminous paint internally through out and externaly for embeded portion and painting with one coat of red oxide primer, applying two coats of synthetic enamel aluminium paint on remaining exposed surfaces after errection complete, painting with synthetic enamel paint of colours black and yellow alternate strips of 30cm width upto 1.5 mtr from the top of coping complete including making suitable holes where required all as specified and directed.Note : PCC in foundation, coping, Earth work ( Excavation, Returning & refilling and removal) will be measured and paid separately under relative items of Sch 'A'.
M&L for Plain cement concrete (1:4:8) type D-2 (Using 40 mm graded crushed stone aggregate) as in foundation for poles mass concretes or in any indicated positions etc complete all as specified
M&L for Plain cement concrete (1:2:4) type B-2 (Using 20 mm graded stone aggregate) for coping of poles including form work all as directed.
Unbinding from insulators ACSR conductor any size of LT/HT over head line for repairs. Re-stretching of ACSR conductor to achieve proper sag and rebinding to the insulators using alumn/GI binding wire and making all existing cable connections all as required at site.
M&L for cross arms, bracings, supports, clamps and back plates fabricated from steel section including nuts, bolts, washers, welding bending cold or hot drilling holes for bolts in any shape ors size as indicated or directed and inclusive of oneprimer coat, one under coat and one finishing coat of alumn paint.
Supply and fix LT line rigid PVC spacers spiral type or of type polyproplene composite(moulded or bolted type) conforming to tests as per IS 1445 and capable of withstanding voltage test upto 23 KV RMS ( Dry power frequency) and upto 10 KV RMS (Wet power frequency) of following sizes on LT OH lines with all necessary T&P and safety norms complete all as specified and directed for carrying out repairs under relevant schedule items.
a) 2 lines
b) 3 lines
c) 4 lines
d) 5 lines
Dismantling old defective feeder pillar box, Supply and installation, connecting eclectically & commissioning in replacement of LT feeder pillar box outdoor type, slopy canopy, double door suitable for openable with locking arrangement mounted on 04 Nos of angle iron legs made duly embedded in PCC blocks, painted with two coats of synthetic enamel paint over a coat of red oxide complete with 320 amps rated Aluminium bus bar suitable for 3 phase 4 wire supply system duly drilled holes and making all cable connection with proper thimbles mounted on epoxy based post insulators and including provn of one MCCB 200 Amps 4 pole 415 Volt, 35 KA, (Thermal magnetic release) Ics=100%Icu and adjustable overload setting 80% to100%
Material and labour for GI tubing light grade 80 mm bore with fittings laid for protection of cable under road crossing fixed to walls or pole complete all as specified and as directed.(clamps for fixing pipe, nuts, bolts washers shall be measured separately )
All as per item No.41 herein before but of size 40 mm nominal bore size
All as per item No.41 herein before but of size 50 mm nominal bore size.
S&F in repair powder coated Mild steel junction box wtih MCB SP 03-10 Amps-01 No outdoor type , CRCA sheet with front openable hinged door , locking arrangements with 4 Nos Aluminum bus bars , 200 Amps, mounted on porcelain insulator, glands and lugs etc. and fixed to pole/ PTL post etc with suitable size flat iron clamps, nuts , bolts complete including taking down all as specified and directed.
S&F in replacement of bus bar chamber including taking down with MCB SP 10-16 Amps-01 No outdoor type made out of MS sheet 3mm thick with copper bus bar three phase & neutral fixed with insulators and fixing on pole with proper clamps, nuts , bolts & washers of required size and making connection of LT cables with thimbles and making good the disturbed wall surfaces incl water proof PVC sticker like danger mark all as required at site.
Material and labour earthing with steel earth plate electrode of size 60x60cmx6mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanized iron strip of size 32x6mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full length of earth plate, GI medium grade pipe 40 mm bore protection pipe upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, excavation , earth work in any type of soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified or indicated including testing on completion.NOTE :-Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, RCC cover, funnel with watering pipe, GI earth strip upto 7.5 m long for connecting to test point etc. all as required at site for complete earthing).
S &F in repair Aerial bunch cable 1100 Volt grade stranded & compact aluminium phase conductor aerial bunch cable of size 3 x 95 Sqmm and 1 x 70 Sqmm (half core) with stranded massanger conductor of 70 Sqmm (bare massanger ACSR/AAAC) with 1 x 16 Sqmm for street light phase with aluminium alloy. The phase conductor should be insulated with XLPE (sioplas) compound with all fitting such as (anchor clamp, suspension clamp, inline connector, service clamp, insulation piercing connector , for taps from bare lines etc complete). Any other fitting besides this is also deemed to be included in the quoted rates.
All as per item above but of size 3 x 70 Sqmm and 1 x 50 Sqmm (half core) with stranded massanger conductor of 50 Sqmm (bare massanger ACSR/AAAC) with 1 x 16 Sqmm.
Taking down old burnt out MCCB (of any size, make ,shape ) and supply and fixing new MCCB with the existing cable after making it good by cutting out the burnt parts of the cable/lugs, crimping new lugs as per the suitable size, connecting with the new MCCB along with spraders, testing complete all as directed and specified
(i) MCCB 04 pole of 250 current rating with rapturing capcity of 35 KA, 415V, 50Hz, (Thermal magnetic release) Ics=100%Icu and adjustable overload setting 80% to100% complete all as specified
(ii) MCCB 04 pole of 160 A current rating with rapturing capcity of 25 KA, 415V, 50Hz, (Thermal magnetic release) Ics=100%Icu and adjustable overload setting 80% to100%, complete all as specified
(iii) MCCB 04 pole of 125 A current rating with rapturing capcity of 25KA, 415V, 50Hz, (Thermal magnetic release) Ics=100%Icu and adjustable overload setting 80% to100% complete all as specified
(iv) MCCB 04 pole of 100 A current rating with rapturing capcity of 25KA, 415V, 50Hz, (Thermal magnetic release) Ics=100%Icu and adjustable overload setting 80% to100% complete all as specified
(v) MCCB 04 pole of 200 A current rating with rapturing capcity of 25 KA, 415V, 50Hz,(Thermal magnetic release) Ics=100%Icu and adjustable overload setting 80% to100%, complete all as specified
(v) MCCB 04 pole of 63 A current rating with rapturing capcity of 16 KA, 415V, 50Hz ,(Thermal magnetic release) Ics=100%Icu and adjustable overload setting 80% to100%, complete all as specified
Dismantling old rusted defective LT panel and Supply, installing, testing and commissioning of LT feeder pillar box factory made oudoor type, double door, slopy canopy, fabricated out of 3.15mm thick CRCA sheet with angle iron base frame made of 40 x 40 x 6mm ,45 cm height, dust and vermine proof, suitable for voltage 415 V 3 Phase 4 wire weather proof, with IP-54 protection, with separate hinge door for each compartment for incoming and outgoing switchears/MCCB etc with locking arrangement, with back door openable (Screwed), legs grouted in PCC including painting with two coats of epoxy powder paint over a coat of primer after under going a rigorous metal treatment process involving alkaline degreasing, descaling in dilute sulphuric acid or any other acid and phosphate and with aluminium busbar (TPN), suitable double compression copper cable glands complete in all respect for main Panel for Transformer and including provn of the following:- Note: The panel shall be as per CPRI certificate. Note : PCC will be measured and paid separately. (i) 4 Pole MCCB 200 Amp ,50Hz ,415 V with rupturing capacity 25 KA, (Thermal magnetic release) Ics=100%Icu and adjustable overload setting 80% to100% (ii) 4 Pole MCCB 100 Amp ,50Hz, 415 V with rupturing capacity 25 KA,(Thermal magnetic release) Ics=100%Icu and adjustable overload setting 80% to100% (iii) 4 Pole MCCB 63 Amp ,50Hz, 415 V with rupturing capacity 16 KA, (Thermal magnetic release) Ics=100%Icu and adjustable overload setting 80% to100% (iv) 04 Pole MCCB 32 Amp, 50 HZ 415 V with rapturing capacity 16 Ka,(Thermal magnetic release) Ics=100%Icu and adjustable overload setting 80% to100% -02 Nos (v) Digital type Volt meter, range 0 to 500 Volt with slector switch (vi) Digital type Ameter , range 0 to 600 Amp with slector switch and CT (vii) Indicator lamp RYB.
Taking down defective street light fitting of any size/ type/ capacity from height of pole/walls/high mast of any location exceeding 7.0 m height for repair work and re-fixing back after repair work including checking, inspecting, testing and commmissioning complete all as specified and directed. Note:a) The M/L for Items like ballast, lamp, igniters, capacitors, electronic drivers,surge protection devices etc shall be measured and paid separately under relevant items here in under this Schedule. b) Necessary tools like ladders & other T&P required etc shall be arranged by the Contractor. c) The rate quoted deemed to be inclusive for minor parts nut bolts, circle clips, clamps etc if any required at site.d) The M/L for repairs to LED panel is not included in the scope and shall be measured and paid separately. (e) The Contractor shall depute manpower for attending/rectifying the defects/complaints on daily basis for each area/complex separately. Recovery for non rectification of complaints within 2 days time period after receiving complaints shall be at the rate of Rs 500/- per each complaint.
S&F in replacement of PVC insulated 3 core 1.5 Sq mm stranded copper conductor cable for connecting junction box to street light fitting, testing and commissioning all as directed.
M&L in replacement for bracket for street light fitting made out of 40 mm bore pipe light grade GI tube 1.2 Meter length bent to shape required, fixed with and including MS flat iron clamps, bolts, nuts, washers duly painting the bracket with two coats of aluminium paint over a coat of zinc chrome primer complete.
Supply and fixing in replacement of timelite distribution boards (street light DBs) 40 A 3 pole with 230 V Astronomical time switch complete all as directed including dismantling old one
Supply and fixing in replacement of Surge protection device of capacity 10 KV suitable for LED light fitting
Supply and fixing Electronic driver potted type IP-65, suitable for 200 to 300 W LED light fitting complete all as specified.
Supply and fixing Electronic driver potted type IP-65, suitable for 125 to 180 W LED light fitting complete all as specified.
Supply and fixing Electronic driver potted type IP-65, suitable for 90 to 120 W LED light fitting complete all as specified.
Supply and fixing Electronic driver potted type IP-65, suitable for 70 to 80 W LED light fitting complete all as specified.
Supply and fixing Electronic driver potted type IP-65, suitable for 30 to 60 W LED light fitting complete all as specified.
Supply and fixing galvanised steel tube light grade of 15 mm dia, over the electrict pole with the help of suitable size MS clamp, passing the service cable from the busbar to the light fitting throught it, and making connection, of the cable to both the ends from bus bar to the light complete all as directed and specified.
Taking out un-serviceable/faulty cable/service connection cable of any grade / type / class of size of 95 Sq mm to 185 Sq mm 3.5/4.0 core for repair / replacement from pole / wall / cable duct under ground trench etc for re-use or removal from site of work all as specified and as directed by the Engineer-in-charge(Note- Excavation and earth work shall be measured and paid separately)
Repair only street light fitting any type on poles/walls and making good all loose elctric connections of street light and making serviceable complete all as spfd and directed.
S&F for repair LED Flood light fittings on rail/ steel tubular poles of height not exceeding 7.5 mtrs, comprising of epoxy powder coated housing, enclosed with glass cover in frame, of minimum wattage 100 Watts (with total lumen output not less than 10000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) with ingress protection IP 65/66 and SPD of capacity 10 KV etc including necessary clamps etc complete and testing on completion all as specified and as directed. Note : (i) MS Clamp fittings with nut bolts and GI bracket will be measured and paid separately.(ii) Minimum 2 years guarantee period of LED fittings (iii) Driver shall be IP 66 degree of protection potted seal type with inbuilt SPD and external SPD of capacity 10 KV to be provided in addition to inbuilt. (iv) Power factor more than 0.9 (v) Contractor shall submit LM 79 and LM 80 test reports from manufacturer from approved laboratory.
Supply and fixing in repair LED inverter street light 45W with RTC having luminium housing with clear toughened glass front coveer, IP 66 protection, operating voltage of 140V to 270V, having an efficiency of upto 02 hrs backup, reserve polarity protection , hight voltage cut off at 300V+- 10V and 5 KV internal surge protection with a power factor greater than 0.95 complete making connection with street light box or OH line using PVC insulated and sheathed single core multi stranded alumn conductor cable of size 2.5 Sqmm all as directed by Engr-in-Charge.
Supply & fixing in repair LED Flood light fittings on rail/ steel tubular poles of height not exceeding 7.5 mtrs, comprising of epoxy powder coated housing, enclosed with glass cover in frame, of minimum wattage 200 Watts (with total lumen output not less than 20000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) with ingress protection IP 65/66 and SPD of capacity 10 KV etc including necessary clamps etc complete and testing on completion all as specified and as directed. Note : (i) MS Clamp fittings with nut bolts and GI bracket will be measured and paid separately.(ii) Minimum 2 years guarantee period of LED fittings (iii) Driver shall be IP 66 degree of protection potted seal type with inbuilt SPD and external SPD of capacity 10 KV to be provided in addition to inbuilt. (iv) Power factor more than 0.9 (v) Contractor shall submit LM 79 and LM 80 test reports from manufacturer from approved laboratory.
Supply & fixing in repair LED street light fittings on rail/ steel tubular poles of height not exceeding 7.5 mtrs, comprising of epoxy powder coated housing, enclosed with glass cover in frame, of minimum wattage 90 Watts (with total lumen output not less than 9000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) with ingress protection IP 65/66 and SPD of capacity 10 KV etc including necessary clamps etc complete and testing on completion all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items. (ii) Minimum 2 years guarantee period of LED fittings (iii) Driver shall be IP 66 degree of protection potted seal type with inbuilt SPD and external SPD of capacity 10 KV to be provided in addition to inbuilt. (iv) Power factor more than 0.9 (v) Contractor shall submit LM 79 and LM 80 test reports from manufacturer from approved laboratory.
Supply & fixing in repair LED street light fittings on rail/ steel tubular poles of height not exceeding 7.5 mtrs, comprising of epoxy powder coated housing, enclosed with glass cover in frame, of minimum wattage 50 Watts (with total lumen output not less than 5000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) with ingress protection IP 65/66 and SPD of capacity 10 KV etc including necessary clamps etc complete and testing on completion all as specified and as directed. Note : (i) MS Clamp fittings with nut bolts and GI bracket will be measured and paid separately.(ii) Minimum 2 years guarantee period of LED fittings (iii) Driver shall be IP 66 degree of protection potted seal type with inbuilt SPD and external SPD of capacity 10 KV to be provided in addition to inbuilt. (iv) Power factor more than 0.9 (v) Contractor shall submit LM 79 and LM 80 test reports from manufacturer from approved laboratory.
Supply & fixing in repair LED street light fittings on rail/ steel tubular poles of height not exceeding 7.5 mtrs, comprising of epoxy powder coated housing, enclosed with glass cover in frame, of minimum wattage 60Watts (with total lumen output not less than 6000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) with ingress protection IP 65/66 and SPD of capacity 10 KV etc including necessary clamps etc complete and testing on completion all as specified and as directed. Note : (i) MS Clamp fittings with nut bolts and GI bracket will be measured and paid separately.(ii) Minimum 2 years guarantee period of LED fittings (iii) Driver shall be IP 66 degree of protection potted seal type with inbuilt SPD and external SPD of capacity 10 KV to be provided in addition to inbuilt. (iv) Power factor more than 0.9 (v) Contractor shall submit LM 79 and LM 80 test reports from manufacturer from approved laboratory.
Supply & fixing in repair LED street light fittings on rail/ steel tubular poles of height not exceeding 7.5 mtrs, comprising of epoxy powder coated housing, enclosed with glass cover in frame, of minimum wattage 72 Watts (with total lumen output not less than 7200 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) with ingress protection IP 65/66 and SPD of capacity 10 KV etc including necessary clamps etc complete and testing on completion all as specified and as directed. Note : (i) MS Clamp fittings with nut bolts and GI bracket will be measured and paid separately.(ii) Minimum 2 years guarantee period of LED fittings (iii) Driver shall be IP 66 degree of protection potted seal type with inbuilt SPD and external SPD of capacity 10 KV to be provided in addition to inbuilt. (iv) Power factor more than 0.9 (v) Contractor shall submit LM 79 and LM 80 test reports from manufacturer from approved laboratory.
Supply & fixing in repair LED street light fittings on rail/ steel tubular poles of height not exceeding 7.5 mtrs, comprising of epoxy powder coated housing, enclosed with glass cover in frame, of minimum wattage 120 Watss (with total lumen output not less than 12000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) with ingress protection IP 65/66 and SPD of capacity 10 KV etc including necessary clamps etc complete and testing on completion all as specified and as directed. Note : (i) MS Clamp fittings with nut bolts and GI bracket will be measured and paid separately.(ii) Minimum 2 years guarantee period of LED fittings (iii) Driver shall be IP 66 degree of protection potted seal type with inbuilt SPD and external SPD of capacity 10 KV to be provided in addition to inbuilt. (iv) Power factor more than 0.9 (v) Contractor shall submit LM 79 and LM 80 test reports from manufacturer from approved laboratory.
Supply & fix replacement decorative path way light lighting LED decorative post top lantern for 360 degree 40 watts 230 volts, 50 HZ, maple shaped in sothing opal/ prismatic finish made up of polycarbonate,including all accessories prewired complete.Note :- (i) Minimum 2 years gaurntee period of LED fittings (ii) Driver shall be IP 66 degree of protection potted seal type. (iii) Power factor more than 0.9
Supply & fixing in replacement of unsv 4 Pole on load changeover switch of following current carrying capacity 630 Amps including necessary additional/alteration to busbars of panel and dismantling the old burnt out change over, fixing complete with suitable lugs, testing complete as directed and specified
Taking down old unserviceable security light fittings from any height and Supply & fixing in repair Solar smart intergreted Solar LED Street light fitting (All in one type) with built in Mono Crystalline Panel, lithium ion battery (LiFePO4), MPPT charger controller, PIR sensor with colour temp 600-6500 K with minimum 40 W capacity LED light fittings with hybrid switch, Mono crystalline solar panel of capacity 48W+ 4W (mono), PIR sensor, IP65, 12.8V, 27 Ah lithium ion (LiFePo4) battery inbuilt in fitting, MPPT charge controller with efficiency > 90%, CRI > 70, autonomy for minimum 2 days, charging time 1 day, suitable for working temperatures -10 Degree C to +55 Degree C, fixed on 9.0 meter steel tubular pole/RCC pole complete all as directed & specified. Note : The rate is inclusive of fitting, battery, controller etc complete. The GI pipe bracket along with clamps will be measured and paid separately.
Taking down carefully aluminum/copper Flame proof point wiring for light complete with fitting such as switches, tube lights, ceiling rose, MCB DB, MCB'S,Main switch from control board and making good disturbed surfaces of walls, floor to match with existing specification complete and all as specified.
Taking down main switches, distribution boards and cut outs etc. of any type and capacity along with the existing boards and removing the same from site and making good the disturbed surface/portion of walls all as directed by Engr-in-Charge.
Taking down carefully sub main wiring of any nos of wire and size with earth wire from wooden batten/surface conduit/casing caping complete with its all accessories
M & L in replacement of Flame proof point wiring with 1.5 Sqmm 1100 volts grade PVC insulated FRLS copper conductor single core multi strand flexible cable with proper colour coding in and incl ERW rigid steel conduit & fittings (ISI marked) and accessories incl flame proof bends, copules junctions boxes etc fixed on wall/ceiling with proper fixing arrangements incl proper conductor 1.5 Sqmm PVC insulated unseathed multi stranded FRLS copper conductor single core cable (green color) as earth lead continuity conductor fixed to earth terminal and metalic body of light fittings complete all as suitable for one/two independent light point controlled by one way one switch all as specified and directed.
M&L in replacement of Flame proof submain wiring with two single core PVC insulated flexible copper conductor multistranded cable (FRLS) of size 4 sqmm with proper color coding and one single core PVC insulated flexible copper conductor multistranded cable green colour of size 2.5 Sqmm as earth lead in & incl ERW rigid steel conduit & fittings (ISI marked) and accessories incl flame proof bends, copules junctions boxes etc fixed on walls for laying conduit and making good the disturbed wall surfaces to match with existing specification all as required at site or directed by Engr-in- charge.
M & L for Replacement of flame proof LED tube light fitting 1x8 Watt,IP-65 complete inclunding all accessories prewired with heat resistant glass cover, polyester resin enclosure and centrally locking system suitable for class I,Zone II E Ex II C including proper fixing arrangement on elevation on angle iron frame with clamps, nut, bolts & washers of suitable size as recommended by manufacturer and directed by Engr-in-Charge including electric connection.
All as per item above but of 2 x8 Watt complete all as specified and directed.
All as per item above but of 1x16/20 Watt complete all as specified and directed.
All as per item above but of 2x16/20 Watt complete all as specified and directed.
Supply and fixing explosion proof rotary switch, single pole ON/OFF with cable termination box in LM6, 16 Amps rating 240 volts class E Ex I C suitable for class 1, Zone-II all as specified and directed.
Distribution board enclosure 8 way made out of galvanised steel sheet class EX II housed with MCBs of following capacities :- (a) MCB SPN 10 KA breakng capacity 32 Amps - 01 No (b) MCB SP 10 KA breaking capacity 6 Amps-06 Nos
Distribution board enclosure 4 way made out of galvanised steel sheet class EX II housed with MCBs of following capacities :- (a) MCB SPN 10 KA breakng capacity 20 Amps - 01 No (b) MCB SP 10 KA breaking capacity 6 Amps-04 Nos Note :- The enclosure and MCBs should be flameproof with explosion protection suitable for Zone - II. The rate quoted by the tender shall be deemed inc of all accessories required for the connections.
S & F for replacement flameproof LED tube rod 18/20 watt energy efficient tube light complete all as specified and directed. Note power factor should not be less than 0.90.
M&L for repair of Diesel Engine of 200 KVA by dismantling the Sub-assemblies such as fuel pump, fuel injection, Governor, turbo-charger, radiator, oil cooler, engine heads, rocker arms, self starter, dynamo-engine wiring, terminal contacts and safety controls etc. including replacement of spare parts as required and re-assembling the sub-assemblies after carrying out necessary repairs including testing and commissioning complete all as directed by Engineer-in-charge for the following capacity. Notes: (a) Supply only Spare Parts required shall be measured and paid separately under relevant items of Schedule 'A' (b) Repairs and calibration of Sub-assemblies shall be measured and paid separately under relevant items of Schedule 'A'
M&L for Repair & Calibration of turbo super charger as per calibration procedure and norms as per manufacturer's guide lines including replacement of Turbo supply & discharge hoses and clamps and de-scaling of Turbo charger complete all as specified and directed for the following capacity of DG Sets:Note : Spares will be measured separately under relevant schedule (a) 200 KVA DG set
M&L for Repair & Calibration of PT Fuel Pump & Injectors as per calibration procedure and norms as per manufacturer's guide lines including replacement of unserviceable 'O' rings, Plungers and cups etc. for the following capacities. Note : Spares will be measured separately under relevant schedule (a) 200 KVA DG set
M&L for De-scaling of radiator of 200 KVA DG Set by dismantling the upper & lower tank and cleaning the core pipes with cleaning chemicals (radi wash), components and arrest the leaking core by brazing/ dummy with lead including cleaning of upper and lower tanks and replacing the upper and lower gaskets and required nuts, bolts, refixing the same including testing and painting complete all as specified and directed.
Supply only the following Spare Parts as required during repair of 200 KVA DG set
(a) Head gasket kit
(b) Valve intake
© Valve exhaust
(d) Valve seat intake
(e) Valve air deflector intake
(f) Valve seat exhaust
(g) Valve springs
(h) Valve guides
(j) Shut down valve
(k) Fuel pump gasket kit
(l) Injector cup
(m) Injector O rings set
(n) Fan belts
(o) Magnetic pick up
(p) B check kit
(q)) Air filter set
(r) Turbo charger mounting gasket
(s) Coolant
(t) Turbo charger nuts
(ac) Alternator coupling bushes set
(ad) Hose plain
(ae) Seal O ring set
(af) Gasket governor housing
(ae) Gasket cam foller housing
(af) Cap filler
(ag) Screw sloted set
(ah) Nut regular
(aj) Push rod
(ak) Push rod valve
(al) Gasket breather
(an) Hose hump
(ap) Clamps set
(aq) Hose plain
(ar) Hose elbow
(as) Turbo supply hose
(at) Dipstick
Supply only engine oil 15W40 or as per manufacturers recommendations.
M&L for carrying out 'B' check of 320 KVA capacity, as per manufacturer's recommendation including replacement of filter, 'O' rings, engine oil, gasket, coolant etc complete. Note: The quoted rate inclusive of filter, "O" rings, engine oil, gasket, coolant etc
Complete all as per Item No. 101 above but for 100 KVA to 200 KVA.
Complete all as per Item No. 101 above but for 20 KVA to 62.5 KVA.
Disconnecting and removing existing unserviceable battery and S&F maintenance free battery 12V 180 AH including terminal clamps, copper lead 3m long each including testing and commissioning, Complete all as specified and directed.
Disconnecting and removing existing unserviceable battery and S&F maintenance free battery 12V 100 AH including terminal clamps, copper lead 3m long each including testing and commissioning, Complete all as specified and directed.
SCH. OF CREDIT = Rs.134785.00
Note: In case the tenderer quotes different rates for similar item then lowest rate shall only be applicable for payment and contractor shall not have any claim on this account.
SATISH AND CO
Vijay Kumar Contractor and Engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .