| Sl No | Description | Qty | Unit | Firemax Safety & Security Pvt.Ltd. L1 | R. S. ENTERPRISE L3 | Swathik Mahajan L2 |
|---|---|---|---|---|---|---|
| 1.00 | Supply, Installation, Testing & Commisioning of Micropresssor controlled Addressable Multisensor detector ( VDS / UL / LPCB / FM approved ) with inbuilt optical smoke sensors and heat detector sensor with inbuilt short circuit fault isolator as per NFPA style 72 wiring complete with base (Note : Detectors without built-in fault isolator is also acceptable provided one independent short circuit fault isolator per detector is to be provided extra without extra cost) the detectors should have built in response indicator with LED indicator. The detector should have 360 degree optical view with single / multiple LED that blinks on actuation of detector. Reverse polarity or faulty zone wiring shall not damage the detectors.
(Approved Make : Siemens/Esser/Bosch/Jhonson controls/Notofire/Edward/Secutron/Apollo/Securiton /Morley/system Sensor) | 82 | Nos | 3,500 ₹2,87,000 Lowest | 3,860 ₹3,16,520 | 3,512.8 ₹2,88,049.6 |
| 2.00 | Supply, Installation,Testing & Commisioning of Addressable Manual Call Point ( VDS / UL / LPCB / FM approved ) with in built short circuit fault isolator as per NFPA style 72 wiring complete as required. (Approved Make : Siemens/Esser/Bosch/Jhonson controls/Notofire/Edward/Secutron/Apollo/Securiton /Morley/system Sensor) | 3 | Nos | 4,500 ₹13,500 | 4,500 ₹13,500 | 4,300 ₹12,900 Lowest |
| 3.00 | Supply, Installation, Testing & Commissioning of Addressable Loop Powered Hooter ( sound output of minimum 90 db ) cum strobe (strength of light 10 cd) complete with inbuilt short circuit fault isolator. Degree of protection IP65 ( VDS / UL / LPCB / FM approved) approved. (Approved Make : Siemens/Esser/Bosch/Jhonson controls/Notofire/Edward/Secutron/Apollo/Securiton /Morley/system Sensor) | 3 | Nos | 5,500 ₹16,500 Lowest | 14,500 ₹43,500 | 5,547.34 ₹16,642.02 |
| 4.00 | Supplying, installation, testing and commissioning of LED type Response Indicator ( VDS / UL / LPCB / FM approved) having 2 Nos. red coloured LED lamps including connections etc.(Approved Make : Siemens/Esser/Bosch/Jhonson controls/Notofire/Edward/Secutron/Apollo/Securiton /Morley/system Sensor) | 20 | Nos | 65 ₹1,300 Lowest | 120 ₹2,400 | 89 ₹1,780 |
| 5.00 | Supply & Laying of 2 Core 1.5 sq.mm FRLS shielded copper Cable (For Loop) (Make. Finolex/Gloster/ RR Kable/Polycab ) through 19 mm dia PVC 'FR' type Rigid Conduit pipe with necessary arrangement as per G.S. (Make : Precision/ AKG/ Universal/ Polycab) on the surface of the wall. | 700 | Mtr | 78 ₹54,600 Lowest | 115 ₹80,500 | 115 ₹80,500 |
| 6.00Rate should be quoted incl. of all taxes and cess. | ||||||
| 7.00Defect Liability period : 1 year | ||||||
Tender Value
Refer Docs
EMD Value
₹7,459
Closing Date
30 Jun 2026, 2:00 pmClosed
EXECUTIVE ENGINEER-l
OFFICE OF THE EXECUTIVE ENGINEER, P.W.Dte. Central Kolkata Health Electrical Division P-12, C.I.T Road(1st floor) KOLKATA
SITC OF Fire Detection System at newly constructed 6th floor in new campus of Dr R Ahmed Dental College Hospital Kolkata.
2026_WBPWD_5015656_1
WBPWD/EE-l/CKHED/eNIT-19/26-27
Open Tender
ELECTRICAL WORKS ORG
Item Rate
20 days
Dr R Ahmed Dental College and Hospital
Please refer Tender documents.
4 documents required · 4 mandatory
₹7,459
Central Kolkata Health Electrical Division
4 Aug 2026
17 Jun 2026
2 Jul 2026
17 Jun 2026
30 Jun 2026
23 Jun 2026
22 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, Installation, Testing & Commisioning of Micropresssor controlled Addressable Multisensor detector ( VDS / UL / LPCB / FM approved ) with inbuilt optical smoke sensors and heat detector sensor with inbuilt short circuit fault isolator as per NFPA style 72 wiring complete with base (Note : Detectors without built-in fault isolator is also acceptable provided one independent short circuit fault isolator per detector is to be provided extra without extra cost) the detectors should have built in response indicator with LED indicator. The detector should have 360 degree optical view with single / multiple LED that blinks on actuation of detector. Reverse polarity or faulty zone wiring shall not damage the detectors.
(Approved Make : Siemens/Esser/Bosch/Jhonson controls/Notofire/Edward/Secutron/Apollo/Securiton /Morley/system Sensor) | 82 | Nos | - | - |
| 2 | Supply, Installation,Testing & Commisioning of Addressable Manual Call Point ( VDS / UL / LPCB / FM approved ) with in built short circuit fault isolator as per NFPA style 72 wiring complete as required. (Approved Make : Siemens/Esser/Bosch/Jhonson controls/Notofire/Edward/Secutron/Apollo/Securiton /Morley/system Sensor) | 3 | Nos | - | - |
| 3 | Supply, Installation, Testing & Commissioning of Addressable Loop Powered Hooter ( sound output of minimum 90 db ) cum strobe (strength of light 10 cd) complete with inbuilt short circuit fault isolator. Degree of protection IP65 ( VDS / UL / LPCB / FM approved) approved. (Approved Make : Siemens/Esser/Bosch/Jhonson controls/Notofire/Edward/Secutron/Apollo/Securiton /Morley/system Sensor) | 3 | Nos | - | - |
| 4 | Supplying, installation, testing and commissioning of LED type Response Indicator ( VDS / UL / LPCB / FM approved) having 2 Nos. red coloured LED lamps including connections etc.(Approved Make : Siemens/Esser/Bosch/Jhonson controls/Notofire/Edward/Secutron/Apollo/Securiton /Morley/system Sensor) | 20 | Nos | - | - |
| 5 | Supply & Laying of 2 Core 1.5 sq.mm FRLS shielded copper Cable (For Loop) (Make. Finolex/Gloster/ RR Kable/Polycab ) through 19 mm dia PVC 'FR' type Rigid Conduit pipe with necessary arrangement as per G.S. (Make : Precision/ AKG/ Universal/ Polycab) on the surface of the wall. | 700 | Mtr | - | - |
| 6 | Rate should be quoted incl. of all taxes and cess. | - | - | - | - |
| 7 | Defect Liability period : 1 year | - | - | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.22 MB
Tendernotice_2.pdf
PDF • 0.65 MB
BOQ_5084568.xls
BOQ • 0.23 MB
2911.pdf
Tender Documents • 0.50 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .