| 1.00 | Civil Items. Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and
disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil . including cost of carriage compltete job. | 1,564.12 | Cum | 300 ₹4,69,236 | 252 ₹3,94,158.24 Lowest |
| 2.00 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. | 1,500 | Cum | 120 ₹1,80,000 Lowest | 198 ₹2,97,000 |
| 3.00 | Extra rates for quantities of works executed :
2.22.1 In or under water and/ or liquid mud, including pumping out water as required. | 938.47 | Cum | 250 ₹2,34,617.5 Lowest | 302 ₹2,83,417.94 |
| 4.00 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)including carriage complete job.including cost of carriage compltete job. | 421.93 | Cum | 7,000 ₹29,53,510 | 5,000 ₹21,09,650 Lowest |
| 5.00 | Providing and fixing up to floor five level precast cement concrete solid blocks including hoisting and seating in position with cement mortar 1:3 (1: cement 3: coarse sand), cost of centering, Shuttering and complete. Crushed 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mmm nominal size) | 95.82 | Cum | 6,500 ₹6,22,830 Lowest | 10,000 ₹9,58,200 |
| 6.00 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size) complete job including carriages. | 106.21 | Cum | 12,600 ₹13,38,246 | 450 ₹47,794.5 Lowest |
| 7.00 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone | 12.13 | Cum | 14,500 ₹1,75,885 | 13,000 ₹1,57,690 Lowest |
| 8.00 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. | 1,99,568 | kg | 115 ₹2,29,50,320 Lowest | 120 ₹2,39,48,160 |
| 9.00 | Centering and shuttering including strutting, propping etc. and removal of form for:
A, Foundations, footings, bases of columns etc. for mass concrete. | 564 | Sqm | 300 ₹1,69,200 Lowest | 350 ₹1,97,400 |
| 10.00 | B, Lintel, beams, plinth beams, girders, bressumers and cantilevers. | 240.56 | Sqm | 650 ₹1,56,364 | 600 ₹1,44,336 Lowest |
Tender Value
₹9.5 Cr
EMD Value
₹19.0 L
Closing Date
6 Sept 2022, 2:00 pmClosed
executive engineer PWD RnB nobra
executive engineer PWD RnB nobra
Construction of Indoor Stadium cum Multipurpose Hal at Government Degree Collage Diskit Nobra
2022_PWD_7348_1
PWD RnB/N/105 2022-23
Open Tender
Civil Works - Buildings
Item Rate
180 days
Nubra
please read NIT condition
7 documents required · 7 mandatory
₹5,000
Payable To executive engineer PWD RnB nobra
₹19.0 L
Yes
Executive Engineer Pwd RnB Nubra
14 Mar 2023
19 Aug 2022
7 Sept 2022
19 Aug 2022
6 Sept 2022
19 Aug 2022
5 Sept 2022
Amount
Civil Items. Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil . including cost of carriage compltete job.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m.
Extra rates for quantities of works executed : 2.22.1 In or under water and/ or liquid mud, including pumping out water as required.
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)including carriage complete job.including cost of carriage compltete job.
Providing and fixing up to floor five level precast cement concrete solid blocks including hoisting and seating in position with cement mortar 1:3 (1: cement 3: coarse sand), cost of centering, Shuttering and complete. Crushed 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mmm nominal size)
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size) complete job including carriages.
Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more.
Centering and shuttering including strutting, propping etc. and removal of form for: A, Foundations, footings, bases of columns etc. for mass concrete.
B, Lintel, beams, plinth beams, girders, bressumers and cantilevers.
c, Suspended floors, roofs, landings, balconies and access platforms.
Columns, Pillars, Piers, Abutments, Posts and Struts Pillar bars main building
e, Edges of slabs and breaks in floors and walls Under 20 cm wide
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. a) works upto plinth level
b) All works above plinth level upto floor V level
COMPRESSED STABILISED EARTH BLOCKS (CSEB) in superstructure above plinth level upto floor five level and curing complete in:Cement mortar 1:6 (1cement : 6 coarse sand)Critical parameters related to finished CSEB:- Dry density 1750 kg/m3 Water absorption Less than 15% Dry Compressive strength More than 2.8N/mm2 Wet Compressive strength More than 1.2 N/mm2 Flexural strength (bending strength) More than 0.5 N/mm2 Pitting depth (Erosion resistance) Less than 10 mm Linear expansion of block upon saturation with water Less than 0.10% Critical parametersof soil for CSEB block production:-Sand and gravel More than 65%Silt 5% to 20% Clay 10% to 15% Plasticity Index Less than or equal to12 Phvalue Between 6 and 8 Stabilizer:- Cement Not less than 5%
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand)
Stone tile work for wall lining upto 10m height with special adhesive likearaldite or equivalent over 12mm thick bed of cement mortar 1: 3 (1 cement: 3 coarse sand) including pointing in white cement with an admixture of pigment to match the stone shade.Granite stone of any colour and shade
Providing and fixing Ist quality ceramic glazed wall tiles conforming toIS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black ofany size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): First class kail wood
Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.With ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws
Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete.250x10mm
Providing and fixing bright finished brass door latch with necessary screws etc. complete 300x16x5 mm
Providing and fixing brass tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 150x10mm
Providing and fixing brass handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete 100mm
Providing and fixing factory made PVC door frames of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet mitred at corners and jointed with two numbers of 150mm long brackets of 15x15mm MS square tube, the vertical door profiles to be reinforced with 19x19mm MS square tube of 19 gauge, EPDM rubber gasket weather seal to be provided throughout the frame. The door frame to be fixed to the wall using MS screws of 65/100mm size complete as per manufacturers’ specifications and directions of engineer-in-charge
Providing and fixing 30 mm thick factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC ‘C’ channel of size 30 mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the ‘C’ Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacturer’s specification & drawin
Providing and fixing factory made uPVC Fenista colour as approved by engineer casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with Casement window double panels with S.S. friction hinges (350 x 19 x 1.9 mm) made of (big series)frame 67 x 60 mm & sash / mullion 67 x 80 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/ double glazing bead of appropriate dimension. (Area of window above 1.50 sqm).9.149A.5 Casement window double panels with S.S. friction hinges (350 x 19 x 1.9 mm) made of (big series)frame 67 x 60 mm & sash / mullion 67 x 80 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/ double glazing bead of appropriate dimension. (Area of window above 1.50 sqm).
Providing and fixing stainless steel (SS-304 grade) friction hinges to the side/top hung UPVC windows, of approved quality, with necessary stainless steelscrews etc. as per direction of Engineer-in-charge 200x19x1.9mm
Providing and fixing casement handle made of zinc alloyed (white powder coated) for UPVC casement window with necessary screws etc. complete.
Providing and fixing of traditional Ladakhi Shingstag of height 2 feet in 2nd class kail wood as per drawing complete in all respects (including polishing, cement concrete coping , fasteners which to be paid separately) including cost of transportation, labour, wood, wastage, taxes, profits etc as per directions of Engineer- in-charge
Structural steel work in built up sections, trusses and framed work,including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Structural Steel shuold be of make : TATA / SAIL / JSW / ESSAR / JSPL.
Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. 40mm thick with 20 mm nominal size stone aggregate.
Chequerred precast cement concrete tiles 22mm thick in footpath and courtyard, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing, cleaning and curing complete, on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand) Light shade using white cement
Providing and laying Ceramic glazed floor tiles of size 600x600 mm(thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc.,complete.
Providing and laying Polished Granite stone flooring in required designand patterns, in linear as well as curvilinear portions of the building allcomplete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge
Providing, fixing and applying Plaster of Paris (POP) false ceiling consisting of frame work made with 50mm sq M.S. tubes of 18 G thickness as main runner at 600 mm c/c both ways, suspended/ supported with M.S. flats 25x4 mm from existing R.C.C. slab, finished smooth to line and level including necessary supports, scaffolding etc. as required and also including applying a coat of red oxide zinc chromate primer over the M.S. frame work and suspenders complete. Including providing and fixing expanded metal of size 5.25 mm x 1.25 mm thickness welded to main runners and applying POP (calcium sulphate semi hydrate variety) to the expanded metal of thickness not less than 10 mm
Thermal Insulation of roofing with Expanded polystyrene fixed with suitable adhesive to the false ceiling as per the directions of the Engineerin- charge.
Providing and laying indoor basketball court vinyl flooring 6.5mm thick of reputed compony (as approved by the engineer/ consultant)
Insulation of wall Providing and fixing (PU) Polyurethane 50mm thick of density 28kg -38 kg/ CU .M in between cavity wall.
Providing and Fixing 15 mm thick densified tegular edged eco-friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanizing @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” ofsize 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main ’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting onperiphery walls /partitions on Perimetre wall angle pre-coated steel size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws@ 230 mm interval and laying 15 mm thick densified edges calcium silicate ceiling tiles of approved texture (Spin tone / Cosmos/hexa) in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanized steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’ , bottom exposed with 24 mm of all T-sections shall be prepainted with polyester baked paint, for all heights, as per specifications,drawings and as directed by engineer-in-charge. Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs)having area less than 0.30 sqm. The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection > 85%, non - combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity <0.043 w/m 0 KC.
15mm Cement plaster on the rough side of single or half brick wall of mix 1 : 6 ( 1 cement : 6 fine sand)
6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand) 1 : 3 ( 1 cement : 3 fine sand) Cement must be PPC with minimum 25% flyash content
Pebble dash plaster up to 10m height above ground floor with a mixture of washed pebble or crushed stone 6mm to 12.5mm nominal size dashed over and including fresh plaster in two layers, under layer 12mm cement plaster 1:4 (1 cement : 4 coarse sand) and top layer 10mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) mix with 10% finally grounded hydrated lime by volume of cement.
Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Finishing with Deluxe multi surface paint system for interiors and exteriors using primer as per manufacturers’ specifications Two or more coats applied @ 1.25 liter/10sqm over and including one coat of special primer applied @ 0.75liter /10sqm
Polishing on wood work with ready mixed wax polish of approved brand and manufacture:
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Dry stone pitching (any thickness) including cost of stones and carriage On Horizontal
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement in position to the required line, level and curvature jointed with cement mortar 1:3 (1 cement: 3 coarse sand) including making joints with or without grooves (thickness of the joints except at sharp curve shall not to be more than 5mm) including making drainage opening wherever required complete etc. as per direction of Engineer-in charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge)
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with with water proofing cement compound @ 0.253kg/ sqm. This layer will beallowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm . This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately.
Providing and mixing integral crystalline admixture for water proofing treatment to RCC structures like basement raft, retaining walls, reservoir, sewage & water treatment plant, tunnels / subway and bridge deck etc. at the time of transporting of concrete into the drum of the ready-mix truck, using integral crystalline admixture @ 0.80% (minimum) to the weight of cement content per cubic meter of concrete) or higher as recommended by the manufacturer’s specification in reinforced cement concrete at site of work. The material shall meet the requirements as specified in ACI-212-3R- 2010 i.e. by reducing permeability of concrete by more than 90%, compared with control concrete as per DIN 1048 and resistant to 16bar hydrostatic pressure. The crystalline admixture shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.
Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approvedshop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).The weight of aluminium extruded section shall be taken for purpose of payment.
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: (a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles,nuts, bolts, clamps etc., structural and weather silicone sealants,flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation equalisation &drainage and protection against fire hazard including:b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and inrequired numbers.(c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.(d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. (e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizesand of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge. Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this subhead. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves) on the external face shall be measured in sqm. up to two decimal places.Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NABL accredited lab or by any other accreditation body which operates in accordance with ISO / IEC 17011 and accredits labs as per ISO/ IEC 17025. 1. Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr 2. Static Water Penetration Test. (50pa to 1500p) as per ASTME- 331-09 testing method for a range up to 2000 ml. 3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml 4. Structural Performance Deflection and deformation by static air pressure test (1.5 times design wind pressure without any failure) as per ASTME-330-10 testing method for arange upto 50 mm 5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4- 09 testing method for Qualitative test, Tests to be conducted on site. 6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml
Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.25.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm.(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. Vision area
Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineerin-Charge.
Providing and fixing mineral fibre false ceiling tiles at all heights ofsize 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance > 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking TGrid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all Tsections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-incharge. With 16 mm thick bevelled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.6 AREA OF FALSE CEILING =758 SQMETRE
Providing and fixing double glazed units(DGU) comprising 6 mm thick glass on either side with 12 mm thick inert gas gapin The DGUs shall be processed from reputed glass processors.
Providing and fixing precoated galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) The roof sheeting will be Double Skin Standing Seam Roofing with PPGL (Bare) type sheeting.The roof panel shall be Steel grade (G345), thickness 0.5mm BMT and finish of Zincalume (AZ 150) steel. Under no circumstances, may the roof be attached to the purlins in the structure with screws. Two lockable roof-access system to be designed on either corner of the building for external access of roof. Vertical fall arrestor will be installed in the Roof Access Ladders.The roof shall also have a two safety harness lines running on the either side of the ridge ventilator or the column line. The Roof Life Line will cover the complete Roof. Base of roof life line will be clamped with metal roof seam.
Provinding and fixing of roof insulation .All Roof will be insulated. All Roof will have insulation of approved make. Insulation to be Bonded Fiber Glass Wool Insulation having density of 48 kg/m3, 75mm thickness suitably factory laminated with high-strength polypropylene (WMP 50) based facing. The polypropylene facing will have extensions or tabs of 50 mm on one or both of the long edges of the insulation blanket. For purlin spacing, nylon mesh will be used over the purlin to withhold the insulation blanket.No part of Metal wall or Roof will remain uninsulated, without prior approval. complete job.
Sanitery Works, Providing, laying and jointing uPVC Pipes (I.S:4985-2000) 6kgf/cm2 including jointing with solvent cement, testing, excavation, refilling and disposal of surplus earth wherever required complete in all respect. a) 110 mm dia
b) 160 mm dia
c) 200 mm dia
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design a)100mm diameter
b)150 mm diameter
c)200 mm diameter
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 150 x 100mm size P-type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design a) Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) ith common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra for depth for manholes :Size 90 x 80 cm With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture’s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m all kinds of soil. Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing and fixing uPVC pipes (Type-B) confirming to IS 13592 : 1992 including all fittings e.g. plain or door bends, junctions, cowls, offsets, access pieces etc. jointing with solvent cement including cutting holes in walls, floors excavation, refilling and disposal of surplus earth wherever required and making good. (The cost of cutting holes of all sizes in RCC walls, slabs & beams wherever required including making good the same with sealents as required by the engineer-in-charge shall be included in the rate).75 mm diameter
b) 110 mm diameter
Providing and laying uPVC Pipes confirming to IS 4985 : 2000) pressure 8kg/cm2 including jointing with solvent cement, testing excavation, refilling and disposal of surplus earth wherever required complete in all respect. Including making connection with floor trap with necessary fittings. a)40 mm nominal bore.
b) 50 mm dia
Providing and fixing sand PVC trap (P trap) of self cleaning design as complete including cost of cutting and making good the cutouts in walls and floors etc. complete 110 mm inlet and 110 mm outlet
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work up to plinth level.1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. (For rain water pipe)
Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-incharge. a) PN-20 to 25 pipe , 25mm OD as directed by the site engineer. inernal
b) PN-20 to 25 pipe , 32mm OD as directed by the site engineer.
c) PN-20 to 25 pipe , 40mm OD as directed by the site engineer.
d)PN - 10 Pipe, 50mm OD (SDR-11)
Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge.Concealed work,including cutting chases and making good the wall etc. a)PN - 16 Pipe, 25mm OD (SDR-7.4)
b)PN - 16 Pipe, 32mm OD (SDR-7.4)
Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801 UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, including trenching, refilling & testing of joints complete as per direction of Engineer-in-Charge. External Work .PN - 16 Pipe, 25 mm OD (SDR-7.4) PN - 16 Pipe, 32 mm OD (SDR-7.4)
PN - 16 Pipe, 32 mm OD (SDR-7.4) PN - 16 Pipe, 32 mm OD (SDR-7.4)
providing and fixing PPR Unions 25mm dia
PPR Union 32mm
PPR Union 40mm
PPR Union 50mm
Providing, fixing, testing and commissioning of high pressure Float Valves of PN-6 rating for Overhead water tanks a. 25 mm nominal bore
b. 25 mm nominal bore
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Providing, fixing, testing and commissioning of insulation on HDPE water tank with layer of class O closed cell Elastomeric Nitrile insulation sheets 15mm thick followed by insulation of 50 mm thick fiberglass insulation (density 48 Kg/cum) all around the tank. the fiber glass insulation shall be protected by 24 gauge aluminium sheet cladding giving proper overlaps & sealing the joints with suitable adhesive compound.
Providing, fixing, testing & commissioning of lever operated gun metal ball valve with SS ball.25mm nominal bore
32mm nominal bore
40mm nominal bore
50mm nominal bore
Providing, fixing, testing and commissioning of Air Release Valves screwed ends with ball valve of approved brand of manufacture, with accessories etc., complete.
Providing, fixing, testing & commissioning of class-O nitral sheet insulation 13mm /19mm thick to hot water pipe and fittings and valves as per manufacturer's recommendations complete to satisfaction of Engineer in charge. a) 25mm dia 13 mm thick
b) 32mm dia 13mm thick
Providing and fixing insulation to Pipes with 50mm thick resin bonded preformed mineral wool pipe sections of density not less than 144 kg/cum. as per IS:9842 and applying 26g Aluminium sheet as cladding, properly rolled and grooved with joints sealed with a strap of roofing felt (type-III Grade-I conforming to IS:1322) complete with self tapping screws centre to centre distance of 150mm to close cladding joints. The pipes shall be painted with zinc chromate primer before applying insulation a) .25mm nominal bore
b) 32mm nominal bore
c) 40mm nominal bore
d)50mm nominal bore
Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design :With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
Providing, fixing, testing & commissioning of Solar Water Heating system complete with solar panels, insulated SS 304 storage vessel with cemamic lining inside & interconnecting pipes and valves complete in all respect as per manufacturer specifications. Tank shall be supplied without electrical boosters. (Solar heaters shall be equivalent to sholarhart model LCSC Thermosiphon solar heating system and suitable for frost & harsh condition.) The Vendor shall include in this rate cost of all interconnecting pipes and valves & insulations connecting the panels). Capacity 180 LPD (comprising 1 no. collector panel and 180 ltres SS 304 storage vessel)
Providing & fixing M.S. Puddle Flange fabricated of 600 mm long 'C' class pipe pieces with screwed ends with center of pipe welded with 6mm thick M.S. plate of size (100mm+D) X (100mm+D) for R.C.C. water tank walls / slabs. The entire fitting shall be hot dipped galvanised. (D indicated above nominal dia metre of pipe in mm). (for Fire overhead tanks) a)25mm dia.
50mm dia
65mm dia
80mm dia
100mm dia
150mm dia
Providing, fixing, testing and commissioning of 50mm dia G.I. Vent Pipe on Under ground and over head tank inlcuding cost of 2 Nos. 900 bend and painting with enamel paint complete with in all respect 50mm Dia) (for Fire overhead tanks).
Providing, fixing, testing & commissioning of 450x600mm rectangular C.I. Cover (IS : 1726-91) with frame light duty total weight 38 kg. (23 kg. cover and 15 kg. Frame (for Fire overhead tanks).
Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.
Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge.
Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:-(a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.(For wash basin)
Providing and fixing CP Brass long body bib cock of approved quality confirming to IS standards and weighing not less than 690 gms. 15 mm nominal bore
Providing and fixing C.P brass angle valve for basin mixer and geyser points of approved quality confirming to IS:8931 15 mm nominal bore
Providing and fixing toilet paper holder.C.P. brass
Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing vitreous China Sanitary fixturs and CP fitting and other accessaries for Handicapped toilet (Matrix Set-1). Each Matrix Set shall comprised (Wash Basin 65 x 35 with one pair mounting brackets, EWC & Cistern complete with fittings & seat cover, one no hinged rail 76 cm and five nos of grab rails 60 cm). complete all respect.
Providing, fixing, testing & commissioning of C.P. brass twin robe hooks equivalent to JAQUAR Cat. No. 1161.
Providing, fixing, testing & commissioning of S.S. hinged grating, 1.5mm thick with frame equivalent to JAYNA NEW HEAVY GRATINGS Cat. No. NHG 140 including setting in floor with cement mortar 1:3.
Providing, fixing, testing & commissioning of automatic high pressure electric water heaters equivalent to VENUS with glass lining thermostats with each element and high temperature cut off, necessary insulation, safety valve, etc. all complete. A)15 litres
b)25 litres
Providing, fixing, testing & commissioning of Health Faucet equivalent to JAQUAR Cat. No. ALD-573 make with flexible pipe and wall hook with each European W.C. Pan.
Providing, fixing, testing & commissioning Soap Dispenser equivalent to (JAQUAR Cat No. ACN-1137N).
Providing, fixing, testing & commissioning of 15mm C.P. brass Connection Pipe Jaquar Cat No. ALD-805B (450mm Long Braided Hose with Two 15mm Nuts & Rubber Washers Without Nipple (Suitable for WC, Geysers & Basin Mixers)) or equivalent make union nuts complete with C.P. brass flange including cutting and making good the walls wherever required. (For Angle Valve)
Electrical Works, Supply installation and commissioning of led fixture 9 W +/- 1 W LED Recess Mounted Downlighter with Deep inset diffuser for glare free lighting. Round Shape Fixture having Die Cast Heat housing and minimum system lumen efficacy of 100 lm/W with P.F.>0.95 and THD<10% ,CRI 80.The LED with Useful life of 50000 Hrs at L70 ,CCT of 5700 K with CRI of minimum 80.The Input voltage range shall be 150V to 270V .Fixture have Surge Protection 2kV .Wipro / Philips/Trilux.
Supply installation and commissioning of led fixture 15 W +/- 1 W LED Recess Mounted Downlighter with Deep inset diffuser for glare free lighting. Round Shape Fixture having Die Cast Heat housing and minimum system lumen efficacy of 100 lm/W with P.F.>0.95 and THD<10% ,CRI 80.The LED with Useful life of 50000 Hrs at L70 ,CCT of 5700 K with CRI of minimum 80.The Input voltage range shall be 150V to 270V .Fixture have Surge Protection 2kV .Wipro / Philips/Trilux.
Supply installation and commissioning of IP20 9W +/-1W COB LED Reccess Mounted Downlighter with titable head minimum system lumen efficacy of 100 lm/W with Pressure Die cast aluminium hosuing and clear glass cover having P.F.>0.95 with THD<10% ,CCT 3000K/4000K ,CRI 80.The LED life of 50000 Hrs at L70.The Input voltage range shall be 150V to 270V. Make: Wipro / Philips/Trilux.
Supply installation and commissioning of IP20 Led fixture 20 W+/- 1W with Surface Mounted 4 Feet with Polycarbonate diffuser with Extruded aluminium housing minimum system lumen output 2000 lumens and system efficacy of 100 Lm/W with P.F.>0.95 with THD<20% ,CRI 80 .The LED with Useful life of 50000 Hrs at L70. The LEDs used in the luminaire shall have CCT of ANSI Bin 6500 K with CRI of minimum 80.The Input voltage range shall be 150V to 270V .The fixture should be BIS Approved.Wipro Cat. No: LL20-281-XXX-65-AL1 or Equivalent in Philips/Trilux.
Supply installation and commissioning of Led fixture 600mmX600mm 33 W+/- 1W Recess Mounted Fixture suitable for creating pattern having system efficacy of minimum 95lm/W Light Light engine and diffuser only on the edeges and hollow in between with Drop Down HET PMMA diffuser. Fixture having minimum system lumen efficacy of 95lm/W with extruded aluminium housing with P.F.>0.95 with THD<10% ,CRI 80,CCT 5000K- 5700 K .The LED with Useful life of 50000 Hrs at L70.Make:Make:LM29-451-XXX-57-XX or Equivalent in Philips/Trilux.
Supply installation and commissioning of 80 W+/-1 W Linear Low Glare LED High bay luminaire, surface/ suspension mounted, Aluminum extruded housing with powder coating, PC lens diffuser, system lumen efficacy 145 lm/W with minimum system lumens of 11600 and beam angle of 120 degree. The luminaire shall have IP66 protection. The LED shall be compliant with Useful L70B50 life of >75000 Hrs. Driver efficiency should be 85% in input voltage range of 140V to 280V (nominal rated voltage – 240V) with 6 KV internal surge protection.Wipro / Philips/Trilux.
Supply installation and commissioning of IP20 led fixture 12 W +/- 1 W LED Surface Mounted Downlighter Round Shape with minimum system lumen efficacy of 100 lm/W with Polycarbonate housing,pressure die cast heat sink and P.F.>0.95 with THD<10% ,CRI 80.The LED with Useful life of 50000 Hrs at L70. The LEDs used in the luminaire shall have CCT of ANSI Bin 5700 K with CRI of minimum 80.The Input voltage range shall be 100V to 265V. Wipro / Philips/Trilux.
Supply installation and commissioning of 10W bulk head Fixture made of Oval shaped pressure die-cast aluminium housing & ring for sturdiness & corrosion resistant and Epoxy powder coated white finish after phosphochromate treatment.High quality polycarbonate diffuser in opal finish for glare free light distribution.High efficiency long life LED module with SMD LED package mounted on MCPCB with lumen efficacy of >130 lm/W with system lumen 800LM. Powered by built-in, isolated electronic LED driver with APFC (SMPS based constant current supply) with lower THD, Output Short / Open Circuit protection, Over Voltage protection, Surge Voltage protection. CCT 6500, CRI>80, THD<10%, PF>.95, IP66,IK 10, Life class of 50,000 hrs @ L70, Operating Temperature:-10 TO +45 DEG.C; Input Rated voltage :240VAC/50HZ.
Exhaust Fan 300mm Sweep,900RPM Crompton, Havells Alstrom
Providing and fixing sloar water heater 500 liter capacity with all fittings and fixture insulated properly with top layer with alumunium sheet as per the direction of Engineer- in - Charge.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group- A
Group- B
Group- C
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface /recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.a) b)2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
c) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
d) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
e)2 X 6 sq. mm + 1 X 6 sq. mm earth wire
g)4 X 10 sq. mm + 2 X 6 sq. mm earth wire
h)4 X 16 sq. mm + 2 X 6 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 1.5 sq. mm
3 x 2.5 sq. mm
3 x 4 sq. mm
3 x 6 sq. mm
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 pair
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.a, 20 mm
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required 5/6 A switch
15/16 A switch
3 pin 5/6 A socket outlet
6 pin 15/16 A socket outlet
Telephone socket outlet
TV antenna socket outlet
Bell push
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. A. 3 Module (100mmX75mm)
b. 6 Module (200mmX75mm)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep
Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cabble
Wiring for group controlled (looped) light point/fanpoint/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A
Group B
Group C
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way , Double door
12 way , Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way (4 + 24), Double door
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Double pole
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. asrequired. .63 A
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required.
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 100 mm width X 50 mm depth X 1.6 mm thickness
150 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 100 mm width X 50 mm depth X 1.6 mm thickness
150 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 100 mm width X 50 mm depth X 1.6 mm thickness
150 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Reducer" (galvanisation not less than 50 microns) with perforation not more than17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required. 100 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Reducer" (galvanisation not less than 50 microns) with perforation not more than17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required. a. 100 mm width X 50 mm depth X 1.6 mm thickness
150 mm width X 50 mm depth X 1.6 mm thickness
225 mm width X 50 mm depth X 1.6 mm thickness
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Supplying, installation, testing & commissioning of heat detector operating at 54ºC/57ºC with rate of rise cum fixed temperature (dual thermistor) type with mounting base complete with all connection etc. as required.
Supplying, installation, testing & commissioning of smokedetector with builtin LED and mounting base complete with all connections etc. as required.
Supplying, installation, testing & commissioning of manual call box of ABS type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required.
Supplying, installation, testing & commissioning response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required.
Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in A.B.S. box with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required.
Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required. 10 zone
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required.
Electrical Panel Design, manufacture, S.I.T.C of following Panels made of 16 S.W.G.C.R.C.A. sheet, steel dust and vermin proof compartmentalized construction with bus bar chambers, cable alley, cable glands plate etc. as required duly painted from inside as well as out side, as below:- Note:- Derating shall be considered as per environmental conditions of Nubra Valley at Ladakh MAIN L+P PANEL-1 SCIENCE LAB INCOMER 1 Set of 250 Amps. 415 Volts. 4P MCCB of 25 KA with overload, S/C and earth fault protection. MAIN BUS BARS 315-Amps 3 phase 4 wire 415 volts 50 HZ aluminium bus bars with colour coded PVC heat shrinkable sleeves (Neutral to be equal to phase size). METERING 1 Set of 0-500-V (96 sq.mm) Voltmeter with VSS & protection MCB 1 Set of 0-100-A / 5-A (96 sq.mm) Ammeter with ASS & CT"s. 3 Nos. phase indication lights LED type with protection MCB. 1 Set of LED indicators for Incoming Breaker 'ON', 'OFF', 'TRIP' LED lamps. OUTGOING 3 Nos. 100 Amp TPN M.C.C.B. of 25 KA with inbuilt protection 7 Nos. 63 Amp TPN M.C.B. of 10 KA MAIN L+P. PANEL-1 AS DESCRIBED ABOVE
UPS PANEL INCOMER 1 Set of 63 Amps. 415 Volts. 4P MCB of 10 KA MAIN BUS BARS 100-Amps 3 phase 4 wire 415 volts 50 HZ copper bus bars with colour coded PVC heat shrinkable sleeves (Neutral to be equal to phase size). METERING 1 Set of 0-500-V (96 sq.mm) Voltmeter with VSS & protection MCB 1 Set of 0-100-A / 5-A (96 sq.mm) Ammeter with ASS & CT"s 3 Nos. phase indication lights LED type with protection MCB. OUTGOING 2 Nos. 63 Amp TPN M.C.B. of 10 KA 6 Nos. 40 Amp DP M.C.B. of 10 KA UPS PANEL AS DESCRIBED ABOVE
Fire Fighting Work . Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) a. Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 b. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325. c. M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. d. Suitable cement concrete foundation duly plastered and with anti vibration pads. e. 900 lpm at 35 m Head
Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.
Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required
Providing, laying, jointing, testing, & commissioning the PVC insulated & sheathed FRLS Armoured cables of 1.1 K.V. Aluminium Conductor including supplying and making end termination with brass compression glands:3 core x 10 sq.mm
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required.100 mm dia pipe
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :a. 25 mm dia pipe
b. 80 mm dia pipe
c. 100 mm dia pipe
d. 150 mm dia pipe
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Gunmetal
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Gun Metal
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle.Drum and brackets for fixing the equipmets on wall.Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.30 m
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :Gun metal
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : a.80 mm dia
b 100 mm dia
c. 150 mm dia
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : a. 100 mm dia
b. 150 mm dia
Providing, fixing, testing & commissioning of Drainage Provision for the risers with necessary 40 mm dia pipe, ball valve etc as required. Maximum length of pipe shall be 10 M.
Providing, fixing, testing & commissioning of 25 mm dia screwed inlet forged brass single acting air valves connected with ball valve on inlet side at top of the Risers.
Providing and fixing in position the industrial type Pressure Gauges with gun metal / brass valves complete as required
Providing, fixing, testing & commissioning of door with frame for all internal fire hydrants fabricated from 18 gauge CRCA M.S. sheet double door including 2 nos allen key lock for locking along with padlock arrangement & fully glazed with 5 mm thick float glass approved by local Fire Authority, stove enameled fire red finish with " fire hose' written on front with radium strip suitable to house 15 mm long four length of canvas hose with couplings, one no of branch pipe, one fire mans axe and two numbers of portable extinguishers, first aid fire hose and supports for hoses, branch pipes, Axe and hose reel. as per approved design including necessary fixing arrangement for hoses & axe and branch pipe.).
Providing, fixing, testing & commissioning of standard Fireman's Axe with heavy insulated rubber handle.
Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :2 way-100 mm dia M.S. Pipe
Providing, installation, testing and commissioning of ABC type fire extinguishers consisting of welded MS cylindrical body, squeeze lever discharge valve fitted with pressure indicating gauge internal discharge tube, 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to ISI finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.Capacity 6 kg. I.S.I. Marked.
Providing, installation, testing and commissioning of Carbon-di-oxide fire extinguishers consisting of welded M.S cylinderical body,squeeze lever discharge valve fitted with internal dischargetube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, confirming to IS : 934 finished externally with red enamel paint and fixed to wall with brackets with rawl plug/dash fasteners complete with internal charge.Capacity 4.5 kg. I.S.I. Marked.
M/S TONYOT TASHI
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.31 MB
BOQ_17632.xls
BOQ • 0.48 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .