Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.4 CrAccepted-AOC 202 400 602 | THANE | MAHARASHTRA | 400601 | ₹4.4 Cr Quoted ₹4.5 Cr | L1 | Accepted-AOC Accepted |
| 2 | L2₹5.7 Cr+₹1.2 Cr (26.0%)Rejected-Finance 112 BHAVESHWAR ARCADE LBS MARG GHATKOPAR WEST MUMBAI 400086 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400086 | ₹5.7 Cr+₹1.2 Cr (26.0%) | L2 | Rejected-Finance Rejected |
Tender Value
Refer Docs
EMD Value
₹1.5 L
Closing Date
18 Apr 2023, 3:00 pmClosed
City Engineer KDMC
Kalyan Dombivli Municipal Corporation, Shankarrao chowk, Kalyan(W)
OPERATION, MAINTENANCE and REPAIRS OF 150 MLD CAPACITY WATER TREATMENT PLANT AT NETIVALI FOR 2 YEARS.
2023_KDMC_888114_1
KDMC/WATER/2022-23/22-2
Open Tender
Civil Works - Water Works
Item Rate
730 days
Kalyan Dombivli Municipal Corporation area
Please refer Tender documents.
14 documents required · 14 mandatory
₹2,360
₹1.5 L
In the Chamber of Hydraullic Engineer Water,KDMC,
13 Oct 2023
28 Mar 2023
19 Apr 2023
28 Mar 2023
18 Apr 2023
28 Mar 2023
5 Apr 2023
Amount
Item No.:-1 Operation, maintenance, repairs & replacement of electrical & mechanical equipment, to smoothly operate 150 MLD capacity Netivali Water Treatment Plant with all materials and manpower specified in detailed specification for carrying out day to day works at Netivli W.T.P. including all required spare parts, labours for operating 24 x 7, repairs / replacement within stipulated time period, day to day maintenance of machinery, cost of all labours, materials etc. as directed by the engineer in charge.
Item No.2 Revamping of Existing PLC based Automation System with license software GE ifix compatible on windows license , windows 10 &11, development of PLC and SCADA software, loop checking of all the existing cabling , checking healthiness of existing instruments and commissioning of the system as per mentioned in detailed specification.
Item No. 03 Removing loose rust from the reinforcement bars by wire brushing, light hammering etc. and applying sulphate and chloride free inorganic single component rust remover Rusticide as approved by Engineer in charge conforming to IS 9077. The rusted surface shall become blackish non rusted colour. After 24 hours of application of rust remover, loose particles shall be removed by brush. Apply one more coat of Rusticide. Apply bonding coat slurry of high performance acrylic polymer - Methyl 2-methylpropenoate copolymer with another enoate as approved by Engineer in charge on entire surface. Mix 1 Kg of acrylic polymer with 0.5 Kg of cement. Finish it with ready to use repair polymer modified mortar based on special cements, aldehyde based polymers with thixotropy modifying agents as approved by Engineer in charge (The Polymer Modified Mortar (PMM) should attain min. compressive strength of 20 N/mm2 in 1 day and 30 N/mm2 in 7 days) by adding 13 - 16% water by weight of polymer modified mortar for treatment to the damaged RCC members. Add 1 Kg of Migrating Corrosion Inhibiting Admixture as approved by Engineer in charge per 25 Kg bag of polymer modified mortar. After mixing polymer modified mortar, it can be trowel applied or sprayed. When applying by hand, polymer modified mortar must be forced tightly into the substrate to ensure complete contact with the substrate.
Item No. 04 Providing and fixing zinc alloy based galvanic disk type sacrificial anodes (50 mm dia, 18 mm thick) as approved by Engineer in charge to the reinforcement, that should have a 3 years track record of use in PWD projects, 4 year track record in corrosive region of abroad and pass 500 hours salt spray test as per ASTM B 117. The anode shall be connected to the reinforcement steel by connectors provided with the anode. Sacrificial Galvanic Anode should have following minimum properties: 1. Base: Zinc Alloy 2. Conformance: ASTM B 418 Type II 3. Zinc Mass: Min 40 g per anode 4. Geometry: Disc Type 5. Diameter: 50 mm 5. Height: 18 mm 6. Surface Area: 6751 sq mm It shall be applied as per manufacturers specification.
Item No. 05 Providing and mixing shrinkage compensating admixture cum plasticizer – Sunplex 330 gms pouch of approved make & approved by Engineer in charge, adding per 50Kilogrambag of cement in sand faced cement plaster to internal/external surfaces in finished in proper line and level. Add Sunplex in dry machine mix before addition of gauging water.
Item No. 06 Providing and applying one pack bonding coat between concrete members like RCC slabs, columns, beams, chajjas, pardis etc and cement mortar plaster using Hack Aid Plast of approved make & approved by Engineer in charge. Clean the concrete surface thoroughly to remove dust, dirt, grime, deshuttering oils and rub down to a clean surface. Apply Hack Aid Plast of approved make & approved by Engineer in charge by spray on the entire concrete surface. Provide a lean cement - sand dash coat over the same. Allow the dash coat to set for around 24 hours. Further plastering as per specifications can continue.
Item No. 07 Clean the surface to remove dirt, loose particles. Examine the surface closely for any cracks. Clean the cracks. Provide and fill a pure acrylic, polymer modified ready to use paste Polyfill AR of approved make & approved by Engineer in charge having a cream coloured viscous emulsion ready to use acrylic polymeric non-shrink crackfiller putty with auto suction properties and requiring no bonding agent, no curing and no requirement for opening the existing cracks finishing with subsequent filling as required. Provide and apply three coats of 100% acrylic waterproof heat insulating breathable decorative external coating Sunext 8 of approved make & approved by Engineer in charge, in the desired shade. Stir well and apply by brush for three coats. Applying three coats at an interval of 4-6 hours between each coat. High Performance 100% Acrylic, Waterproof, Anti-fungal, Anti-carbonation, Heat Insulating External Paint should have following minimum properties: 1. Specific Gravity: 1.3 ± 0.1 at 25°C 2. pH: 7.0 to 10.00 3. Viscosity: 18 to 30 sec. at 25°C by Ford Cup One Number B-4 (Dilute 2 parts of product with 1 part of water) 4. CO2 diffusion resistance co- efficient (DIN EN 1062-6 (2002-10): 7.59 x105 5. CO2 diffusion equivalent air layer thickness (DIN EN 1062-6 (2002-10): 127m @ 190 microns DFT 6. Adhesion (ASTM D 4541): 2.3 N/mm2 (Concrete / Substrate Failure) 7. Solar Reflectance Index (ASTM E 1980 11,EN 673:2011, EN 410:2011): 107 It shall be applied as per manufacturers specification.
Item No. 08 Clean the RCC roof slab surface of all loose particles, dust, cement laitance etc. preferably done using machine like device. Inspect for cracks /construction joints. Fill the cracks by Elastoroof PU of approved make & approved by Engineer in charge. Provide and apply a primer coat of Sunprime PU primer of sunanda or equivalent or approved by Engineer in charge on the cleaned RCC slab surface using a soft paint brush. Shake the container well and directly apply the primer by brush. Allow to set for 30 - 45 mins depending on the ambient temperature. After the primer has totally cured and dried, apply Elastoroof PU of approved make & approved by Engineer in charge by brush, roller or airless spray equipment. Apply at a rate of 1 Kilogram/ One Square Metre for the first coat evenly over the primer surface and allow to set for 12 hours. After ensuring that the first coat is set and cured, apply the second coat in similar manner at a rate of 0.5 Kilogram/ One Square Metre and allow to set. While the second coat is has reasonably hardened but still wet and tacky on surface, sprinkle sand over the surface to make it rough so as to provide mechanical key for the protective screed/I.P.S. of 25 MM thick waterproof bedding. Ensure that the sand does not gets embedded in the second coat and remains on the surface. Allow the two coats of Elastoroof PU of approved make & approved by Engineer in charge to air cure for 4-5 days before proceeding with the protective screed. Single Component, Liquid Applied, Polyurethane Membrane should have following minimum properties: 1. Specific gravity: 1.30 ± 0.1 2. Elongation %: >600 3. Tack free time: 24-48 hrs 4. Tensile strength N/mm2: 2.1 5. Shore hardness: 40 ± 5 It shall be applied as per manufacturers specification.
Item No. 09 Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in- charge. Note:- (1) The elevational area of the scaffolding shall be measured for payment purpose. (2) The payment will be made once only for execution of all items for such works.
ARW INFRA PROJECTS PRIVATE LIMITED
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .