| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.1 LAccepted-AOC | L1 | Accepted-AOC 1ST LOWEST | |
| 2 | L2₹49.7 L+₹1.0 L (2.15%)Rejected-Finance | L2 | Rejected-Finance 2ND LOWEST | |
| 3 | L3₹49.7 L+₹1.1 L (2.21%)Rejected-Finance | L3 | Rejected-Finance 3RD LOWEST | |
| 4 | L4₹49.8 L+₹1.2 L (2.38%)Rejected-Finance | L4 | Rejected-Finance 4TH LOWEST | |
| 5 | Rejected-Technical | - | Rejected-Technical Rejected |
Tender Value
₹32 L
EMD Value
₹64,000
Closing Date
8 Dec 2021, 6:00 pmClosed
GARRISON ENGINEER I GOS
GARRISON ENGINEER I GOPALPUR MILITARY STATION PO GOLABANDHA DIST GANJAM ODISHA 761052
PROVN OF STORE ROOM AND ADDITION ALTERATION TO BLDG 352 INCLUDING SPECIAL REPAIR FOR REPLACEMENT OF BER LIFT OF MH AT GMS UNDER GE I GOS
2021_MES_483312_1
8000/69/21-22/0968/E8
Open Tender
Civil Works
Item Rate
180 days
GOPALPUR ON SEA
PLEASE REFER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER I GOS
₹64,000
Yes
8 Jan 2022
22 Oct 2021
10 Dec 2021
22 Oct 2021
8 Dec 2021
1 Dec 2021
Amount
Excavation in trenches, n.exc 1.5 m wide and n. exc 1.5 m in depth for foundation, etc, or for shafts, wells, cesspits manholes, pier holes, etc exceeding 10 sqm in plan inct getting out soft/loose soil complete all as specified and directed.
M&L for Cement concrete Type D-2, 1:4:8 (40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
M&L for Reinforced cement concrete (Design mix) M-30 (using 20 mm graded stone aggregates) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M&L for Reinforced cement concrete (Design mix) M-30 (using 20 mm graded stone aggregates) as in Columns, pillars, piers, posts and struts complete all as specified and directed.
M&L for Reinforced cement concrete (Design mix) M-30 (using 20 mm graded stone aggregates) as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
M&L for Reinforced cement concrete (Design mix) M-30 (using 20 mm graded stone aggregates) as in Chajjas complete all as specified and directed.
M&L for Reinforced cement concrete (Design mix) M-30 (using 20 mm graded stone aggregates) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, Flat, with fair finished surfaces complete all as specified and directed.
M&L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions (sqaure, rectangular or polygon) with fair finished surfaces complete all as specified and directed.
M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. Flat, with fair finished surfaces complete all as specified and directed.
M&L for Formwork to chullah hoods, chajjas, troughs and similar items including edges Flat, with fair finished surfaces complete all as specified and directed.
M&L for Formwork tosoffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed.
S&F for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as speified and directed.
S&F for Mild steel TMT bars 6 to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as speified and directed.
S&F for Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as speified and directed.
M&L for Brick work with fly ash old size bricks straight or curved on plan exceeding 6 m mean radius complete built in cement mortar 1:6 complete all as specified and directed.
M&L for Brick work with fly ash bricks straight or curved on plan to any radius in half brick thick walls complete built in cement mortar 1:4 complete all as specified and directed
M&L for Rendering on fair faces of brick work or concrete surfaces of wall 15 mm thick in CM 1:6 and to be finished even and smooth without using extra cement complete all as specified and directed.
M&L for Rendering 15 mm thick in cement mortar 1:4, in two layers (1st layer 10 mm thick rendering coat and 2nd layer 5 mm thick finishing coat) on brick work or concrete surfaces, second layer (finishing coat) mixed with liquid water proofing compound @ 200 ml / 50 Kg bag of cement as per manufacturer's instructions and finish the surfaces even and smooth without using extra cement complete all as specified and directed. Note : Liquid WPC will be measured and paid separately.
Supply only water proofing compound (liquid), ISI marked complete all as specified and directed.
M&L for applying 2mm thick Birla / JK Putty in two layers on newly plastered walls surfaces making absolutely even and smooth, rubbing with sand paper complete all as specified and directed
M&L for applying two coats of oil bound distemper on wall or concrete surfaces over & including a coat of primer on prepared surfaces including, rubbing with sand paper complete all as specified and directed.
M&L for preparation of newly plastered surfaces of walls and applying three coat of white wash complete all as specified and directed.
M & L for two coats of cement based paint over a coat of primer on newly plastered surface of walls including preparation of surface complete all as specified and directed.
M&L for Hardcore of broken stone or boulders of gauge n exc 63mm, deposited, spread and levelled in layers n exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L 100 mm thick PCC 1:4:8 type D2 using 40 mm graded stone aggregate as in sub floors complete all as specified and directed.
M&L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in sub base flooring average 25 mm thick surface finished even and rough (as in levelling course) to receive the topping layer complete all as specified and directed.
M&L for Machine cut kota stone slab flooring 18-20 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L for Machine cut kota stone in riser of steps, skirting, dado and pillar 18-20 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L 75 mm thick PCC 1:3:6 type C-1 using 20mm graded aggregate as in plinth protection finishing even & fair without using extra cement laid in bays with construction, 6mm thick joints should be filled with bitumen mastic filling comprising of one part of heated bitumen 80/100 gde and three part of sand (all by weight) complete all as specified and directed.
M&L 10 mm thick rendering on roof surfaces/ concrete surface in CM 1:4 with liquid water proofing compound @ 200 ml per 50 Kg cement complete all as specified and directed. (Waterproofing compound should be measured and paid separately).
Returning, filling in any type of soil, including spreading, levelling, watering and well ramming in layers not exc 25 cm. Complete all as specified & directed.
Removing surplus excavated material (soil) to a distance not exceeding 50 metre & depositing where directed at a level not exceeding 1.5 metre above the starting point, including spreading. Complete all as specified & directed.
Dismantling of floor, hearth, walls, roof tiles including bedding (but not backing), and rubbish off permises complete all as specified and directed.
M&L for non skid ceramic coloured tiles of design as approved 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed.
M&L for glazed ceramic coloured tiles 350 x 250 x 7 mm / 450 x 350 x 7 mm thick on vertical surface such as dado / skirting / risers to steps etc jointed in neat cement slurry and pointed in white or coloured cement to match surface of tiles complete all as specified and directed. Note- (i) The size of tiles (except thickness) may be varied during execution without any price adjustment.
M&L for screed bed or bedding layer of mortar 15 mm thick for laying floor finishes in CM 1:6 for laying of floor tiles complete all as specified and directed.
M&L for Rendering 10 mm thick in cement mortar 1 : 4 for fixing of wall tiles complete all as specified and directed.
Taking down chowkhat or frames n exc 1.50 Sqm each with shutters (without taking off shutters from the frame) and removing to store complete all as specified and directed
S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet re-inforced with MS square tube in opening as per specification and shown on drawing SSR Part-I 2009 complete all as specified and directed.
S&F, factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails MS frame shall be covered with heat moulded plain cover PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for styles and plain colour PVC sheet for top rails lock rail and bottom rail on either side & as gap insert for top rail and bottom rail paneling of plain colour PVC sheet to be fitted in MS frame welded/sealed to the styles and rails with suitable PVC sheet beading and jointed together with solvent cement , as per specification and shown on drawing in SSR Part-I 2009 complete all as specified and directed.
S&F 150 mm long aluminium anodised, barrel tower bolts of extruded section and fixed etc complete all as specified and directed.
S&F 100 mm Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-21 complete all as specified and directed.
S&F 100 mm dia extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
Taking up or down steel tubing and connections including cleaning if refixing or required for 20 mm bore of pipe complete all as specified and directed.
S & F 20 mm bore 3 layer PP-R pipes SDR 7.4 & SDR 11 UV stablised and anti microbial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded PP-R fittings complete to walls, ceilings or in floors complete all as specified and directed.
Making connection of PPR distrubtion branch with PPR main of outer dia of pipe 16 to 40mm size by providing and fixing tee including cutting and making fusion joint etc complete all as specified and directed.
S&F in repair Wash down water closet vitreous china white pedestal pattern with 'P' or 'S' trap including connecting to outgoing drain pipe & to flushing pipe excluding flushing cistern and flush pipe complete all as specified and directed.
S&F in repair plastic water closet seat cover, closed pattern with recessed bottom and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed.
S&F in repairs, PVC valveless syphonic action type low level flushing cistern, 10 ltrs capacity with inlet, ball valve, float and handle including bracket complete all as specified and directed
S&F in repairs flush pipe 32 mm dia of polyethylene of low or high density or PVC, for low level cistern complete all as specified and directed.
S & F in repair 125 mm dia chromium plated shower rose with or without swivel joint incl fixing to steel pipe complete all as specified and directed.
S&F in repair PVC connection 15 mm bore, 450 mm long complete with both ends unions complete all as specified and directed.
S&F in repairs CP anodised tubular tower rail, 20 mm dia, D type, 60 cm long between flanges etc. complete all as specified and directed.
S & F in repair 75 mm PVC(SWR) floor trap with grating incl jointing with solvent cement complete all as specified and directed
S & F in repair sheet Glass Shelf assembly consisting of 5.5 mm glass sheet shelf 12 cm wide with cromium plated bracket guard and railing 60 cm long complete all as specified and directed..
S&F in repairs for vitreous china wash basin, white,flat back, size 550 x 400 mm including supply & fixing of brass chromium plated coupling 32 mm etc complete all as specified and directed.
S & F in repairs Hand shower (Health faucet) with 1 mtr long Easy flex tube in crome finish & wall of approved quality complete all as specified and directed.
S&F in repair PVC waste pipe for WHB etc complete all as specified and directed.
S&F in repairs Chromium plated bib taps cast copper alloy with crutch or butterfly handle fancy type, screwed down, screwed for iron pipe or for brass ferrule of 15 mm bore of pipe complete all as specified and directed.
S&F in repair pillar tap cast copper alloy with capstan head chromium plated crewed down high pressure with or without lettered hot or cold with long screwed sharks and ply nuts 15 mm dia complete all as specified and directed.
S&F in repair Chromium plated Angle Stop cock fancy type 15 mm, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
Excavation in trenches in soft / loose soil, not exceeding 1.5 metre wide & depth exceeding 1.5 metre & not exceeding 3.0 m deep; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sqm on plan including getting out, complete all as specified & directed.
Supply dry sand for cushioning to underground cables 8cm thick before laying cable and 15cm thick after lying and streching the cable, complete all as specified and directed by Engr-in-Charge. Note :- For payment purpose punned thickness shall be measured.
Supply and laying sub class ‘B brick, old size, as cable protection cover, laid dry, flat, transversally along the length of cable, on sand cushioning, with width equal to the length of the brick, complete all as specified and directed.
S&F Galvanised iron water tubing (ISI marked) 25 mm bore (light grade) with and including all fittings (ISI marked ) such as sockets, bends, elbows, unions, tees, diminishing pieces etc laid in trenches/under road/along pole or fixed to walls, complete all as specified and directed.
Supply, laying and testing LT cable XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade cross section area 10 sqmm 2 core complete laid in trenchers, duct, passing through pipe, fixed to poles complete all as specified and directed.
S&F LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
M&L Point wiring complete with PVC insulated and unsheathed,fire retardant low smoke and low halogen smoke 1100 volt grade electric cable of 1.5 Sqmm (nominal area) with multi stranded copper conductor single core in and including rigid PVC concealed conduit not less than 19mm dia, and wall thickness 2mm, with suitable GI flush metal boxes (not less than 1.00mm thick) of suitable sizes including earth dolly with 3mm thick plastic laminated sheet top cover of approved colours including 1.50 Sqmm PVC insulated & unsheathed copper cable as continuous earth wire with all accessories including lugs required, complete all as specified and directed for the following :- (a) One light/fan point controlled by one way switch 5 Amps
(b) One 5 pin socket outlet, 5 Amps, Independent
M&L Point wiring complete with PVC insulated and unsheathed , fire retardant low smoke and low halogen smoke 1100 volt grade electric cable of 2.5 Sqmm (nominal) area) with multi stranded copper conductor single core in and including rigid PVC concealed/ surface conduit not less than 20 mm dia and wall thickness 2mm, with suitable GI flush metal boxes (not less than 1.00 mm thick) of suitable sizes including earth dolly with 3mm thick plastic laminated sheet top cover of approved colours including 1.50 Sqm PVC insulated & unsheathed copper cable as continous earth wire including lugs required for one multi purpose two in one 5 and 15 Amp switch socket on independant board complete all as specified and directed
S&F LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S&F LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F Switch piano flush button single pole one way 6 Amps, complete all as specified and directed.
S&F for Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal complete all as specified and directed.
S&F for Switch socket combination 2 in 1, 5 A flush type complete all as specified and directed.
S&F Sheet metal enclosure factory made single door for mounting MCBs with 200A rated bus bar capacity SPN 04 way AC 240 volts with IP-43 protection, complete all as specified and directed.
S&F Ceiling rose 3 terminals of PVC/ polycarbonate, as per relevant IS code, ISI marked isolated body complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, burried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less'than 1.5 meters below normal ground level, connected to galvanised iron earth lead wire of 4 mm dia GI pipe mediam grade 15 mm dia upto 7.5 mtr including provn of conrete pit in PCC (1:2:4) type B-1 using 20 mm graded stone aggregates with 40 mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 kg/sqm) and frame of angle iron 25x25x3 mm with lugs 02 Nos and with 6.0 mm dia MS bar handle made to shape, GI light grade 20 mm bore pipe for earth plate, common sald and charcoal filing, test point made out of Bronze/ Gun metal with fixing arrangement, funnel, wire mess and excavation/ earthwork in hard/ dense soil, to a distance not exceeding 50 mtr all as per electrical plate No 3 of SSR 2010 Part I and connecting to earth test point complete all as specified or indicated incl testing on completion.
S&F ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1400 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated complete all as specified and directed.
S&F 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning, complete all as specified and directed.
S&F 415V 10KA 'C' curve miniature circuit breaker (MCB) of capacity 32 Amp SPN and current carrying capacity in the DB complete with connection testing and commissioning, complete all as specified and directed.
Taking down and replacement of existing unserviceable street light fitting bracket with new brackets made out of 32mm bore GI pipe, light grade, tubing bend to shape, 1.2 metre long, fixed to pole/wall, painting with two coats of aluminium paint over a coat of red oxide prime complete all as specified and directed.
Taking down /DISMENTLING OF OLD U/S passenger liftc 1360 kg (20passengers) capacity complete and depositing in AGE E/M store yard all as specified and directed by the Engineer-in-Charge.
Design, Manufacture,Supply, installation,testing,& commissioning of Lift electric operated microprocessor based VVVF Driver controlled complete with power driven autometic stainless steel (SS) sliding doors and having SS car enclosure of size 1000x2400 mm,suitable to carrying 20 passengers(1360kg) at a speed not less than 0.5 M/Sec to serve up to 3 floor (G+2) including autometic rescue device 3 phase ,415 volts 50 Hz,IS-14665,AC simplex Automatic and manual dual controlled operation ,LED Lights fittings, ventilation fan ,overload protection,over speed governers, Emergency Firemens Service,Auto blower cut off, Emergency Alarm button ,manual Rescue operation,Electro magnetic brake System,operating panel with luminous buttons, overload warning indicators ,battery operated alarm bell,emergency lights, infrared sensing door,reverse phase relay on controller, digital car position indicator in car with up/down indicators,complete with all standard accessories, all as specified and directed by Engr-in-Charge. Make - KONE/OTIS/OMEGA/HITACHI/ESCON OR Equivalent of higher cost. AMC of lifts: Annual Maintence contract through authorized OEM for minimum period of 12 months including minor repair/servicing of defective parts,periodical monthly servicing and attending all kind of breakdown complain on regular working hours. Note: (i) Contractor shall arrange adequate resourse to measure the lift space and height at site before ordering the product.(ii) Contractor shall get the drawing of lift design approved from GE(I) GOS before dispacting the product(iii)Minor cutting,dressing and drilling or any minor civil work and making good of the disturbed portion shall be borne by the contractor.
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
Demolition of cement concrete un reinforced in ground floor and paving n exc 15cm thick (below or above ground level) complete all as specified and directed.
M&L for walling of random rubble uncoursed stone masonry, well bonded, bedded and solidly hearted built in cement mortar 1:6 complete all as specified and directed.
All as per item No 91 above but except stone
Hammer dressing to RR masonry wall (granite basalt/trap stone) uncoursed with maximum depresion of 40 mm from straight edge held against the surface complete all as specified and directed. (for area to be pointed)
M&L for keyed pointing to random or polygonal rubble, uncoursed or brought upto courses in cement mortar 1:4 complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in surface channels and drains complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in lintels upto 1.5 m clear span, coping, benching, bed block, lintel band, plinth courses etc and similar work including weathering,slightly rounded or chamfered angles and throating including necessary form work complete all as specified and directed.
M&L Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc complete all as specified and directed.
Cutting of bituminous road to the width and depth required for laying SWG pipe or sewage line including hacking , benching and including making good to top surface of road with bitumen & aggregate as per road specification complete all as specified and directed.
S&F in repair NP2 pipe laid and joineted ,with cooller 450 mm dia complete all as specified and directed (In drain work).
M&L for PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for and removal of rubbish from site complete all as specified and directed.
M&L for Precast cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in landings, cover slab (for manholes etc) and similar work including necessary form work and set in CM 1:4 complete all as specified and directed.
M/s Ats Electricals
HARAGOURI SUPPLIERS
M/s MAA BHAIRABI ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .