Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.9 LAccepted-AOC DOCTORS COLONY ROAD NAYAGAON SHADIPUR POST PORT BLAIR 744 106 A N ISLANDS | PORT BLAIR | SOUTH ANDAMANS | A N ISLANDS | 744106 | L1 | Accepted-AOC Being the lowest | |
| 2 | L2₹49.7 L+₹3.3 L (7.05%)Rejected-Finance MB NO 180 MG ROAD JUNGLIGHAT PORT BLAIR 744 103 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L2 | Rejected-Finance Being not the lowest | |
| 3 | L3₹50.3 L+₹3.9 L (8.39%)Rejected-Finance SCHOOL LINE NEAR MINNIEBAY JUNCTION SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L3 | Rejected-Finance Being not the lowest | |
| 4 | L4₹51.8 L+₹5.3 L (11.4%)Rejected-Finance NEAR SATSANG GARACHARMA BASTI GARACHARMA PORT BLAIR 744 105 | PORT BLAIR | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744105 | L4 | Rejected-Finance Being not the lowest | |
| 5 | Rejected-Technical | - | Rejected-Technical not enlisted in reqd category |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
1 Mar 2022, 6:00 pmClosed
GE, Minniebay, Junglighat (PO), Port Blair -744103
GE, Minniebay, Junglighat (PO), Port Blair -744103
REPAIR / MAINTENANCE TO DG SETS, BOOM BARRIERS, HANGER MOTORS, AMF PANEL AND CONNECTED ITEMS AT INS UTKROSH AND VAYU VIHAR BROOKSHABAD UNDER AGE E/M-II AT GE MINNIE BAY, PORT BLAIR
2021_MES_471904_3
8979/E8
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
GE, Minniebay, Junglighat (PO), Port Blair -744103
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE Minniebay
₹98,000
Yes
31 Mar 2022
8 Feb 2022
3 Mar 2022
8 Feb 2022
1 Mar 2022
16 Feb 2022
Amount
S&F in replacement Low oil pressure transducer of 62.5 to 320 KVA DG set as per existing make and model and connecting with DG set system complete all as specified and directed.
S&F in replacement Low lubricant oil pressure safety suitable for 62.5 to 320 KVA DG set as per existing make and model and connecting with DG set system all as specified and directed.
S&F in replacement High water temperature trip safety suitable for 62.5 to 320 KVA DG set as per existing make and model and connecting with DG set system complete all as specified and directed.
S&F in replacement harness wiring suitable for 62.5 to 320 KVA DG set as per existing make and model and connecting with DG set operating system complete all as specified and directed.
S&F in replacement shutdown valve suitable for 62.5 to 320 KVA DG set as per existing make and model complete all as specified and directed.
S&F in replacement of magnetic pick up of 62.5 to 320 KVA DG set as per existing make and model complete all as specified and directed.
S&F in replacement of AVR unit as per existing make and model and suitable for DG set 63 / 82.5 /100/ 125 KVA including connecting with alternator and control panel circuits, starting and testing complete all as specified and directed.
S&F in replacement of AVR unit as per existing make and model and suitable for DG set 160 / 200/250/320 KVA incl connecting with alternator and control panel circuits, starting and testing complete all as specified and directed.
S&F in replacement rotating rectifier assembly as per existing make and model and suitable for DG set 125/160 / 200 /250/320KVA complete all as specified and directed.
S&F in replacement rotating rectifier assembly as per existing make and model suitable for Cummins DG set 25/62.5/82.5/100 KVA complete all as directed at site.
M & L for B check maintenance of DG set of capacity 25 KVA for Kirloskar / Cummins / Cotton greaves / as per OEM including changing of lub oil , oil & fuel filters all as specified by the manufacturer and as directed Note : Engine oil shall be measured and paid separately as "Supply only"
All as per item No 11.00 above but for DG set of capacity 62.5 KVA
All as per item No 11.00 above but for DG set of capacity 82.5KVA
All as per item No 11.00 above but for DG set of capacity 100KVA
All as per item No 11.00 above but for DG set of capacity 125 KVA
All as per item No 11.00 above but for DG set of capacity 160 KVA
All as per item No 11.00 above but for DG set of capacity 200 KVA
All as per item No 11.00 above but for DG set of capacity 250 KVA
All as per item No 11.00 above but for DG set of capacity 320 KVA
M & L for B check maintenance of 156 HP drainage pump for Kirloskar / as per OEM including changing of lub oil , oil & fuel filters all as specified by the manufacturer and as directed by the Engr-in-Charge Note : Engine oil shall be measured and paid separately as "Supply only"
M & L for repair and reconditioning of battery charge alternator 24 V DC for Cummins / as per OEM including taking out the defective alternator from 100/125 / 160 KVA / 200 KVA/250/320 capacity DG set , complete dismantling and repair and replacing the carbon brushes, rectifier diode set, bearing and bush, regulator control, refixing the same in the DG set and connecting with the circuit including all required items, starting and testing all as specified and directed
M & L for repair and reconditioning of battery charge alternator 12 V DC cummins make including taking out the defective alternator from 25 / 62.5 KVA / 82.5 KVA capacity DG set , complete dismantling and repair and replacing the carbon brushes, rectifier diode set, bearing and bush, regulator control, refixing the same in the DG set and connecting with the circuit including all required items, starting and testing all as specified and directed
Supply only coolant for radiator suitable for DG set of capcity 25/62.5 / 100/ 125 / 160/200/250/ 320 KVA of Make- Cummins/ Cotton greave/ Kirloskar under cat part no 3167215 all as per manufacturers recommendations and directed
Supply only engine oil suitable grade SAE-20W40 complete all as specified and directed.
M & L for fixing in replacement of asbestos rope 12 mm dia for wrapping the exhaust pipe of DG set all as directed
M & L for fixing in replacement of Air filter of 25/62.5/100/125 KVA DG set of make Cummins/ Cotton greave/ Kirloskar cat part no. 4055283 all as specified and directed by Engineer-in-charge.
M & L for fixing in replacement of Air filter of 160 / 200/250 / 320 KVA DG set of make Cummins / Cotton greave/ Kirloskar all as specified and directed
M & L for fixing in replacement water pump of 100/125/160 / 200/320/250 DG set of make Cummins/ Cotton greave/ Kirloskar parts no. AR45347 all as specified and directed
M & L for fixing in replacement replacement of water pump of 25/ 62.5/82.5 KVA DG set of make Cummins/ Cotton greave/ Kirloskar all as specified and directed
M & L fixing in replacement of fan belt ( each set ) in 25/62.5/82.5/100 / 125 KVA DG set of make Cummins/ Cotton greave/ Kirloskar cat part no. 178623 all as specified and directed
M & L for fixing in replacement of fan belt ( each set ) in 160/ 200/ 250 /320 KVA / DG set of Make Cummins/ Cotton greave/ Kirloskar part no. 178611 all as specified and directed
M & L for fixing in replacement of belt water pump ( each set ) in 25/62.5/82.5/100/125 KVA DG set of Make- Cummins/ Cotton greave/ Kirloskar part no.200328 all as specified and directed
M & L for fixing in replacement of belt water pump ( each set ) in 160/200/250/320 KVA DG set of Make- Cummins/ Cotton greave/ Kirloskar all as specified and directed
M & L for repair and reconditioning the starter motor of Kirloskar / Cummins / Greaves as per make / model at site including taking out the defective starter from 160 KVA / 200 KVA /250/320KVA capacity DG set , complete dismantling and repair and replacing the carbon brushes with holder, solenoid switch assembly, bush, commutator unit, stator running coil unit , stator starting coil etc and connecting with the circuit including all required items, starting and testing and commissioning all as specified and directed Note : Supply only of spare parts shall be measured and paid separately under relevent item of this Schedule
Supply only Carbon brush set with holder as per existing make and model suitable for 160 KVA / 200 KVA /250/320KVA capacity DG set complete all as specified and directed .
Supply only Solenoid switch assembly with bush as per existing make and model suitable for160 KVA / 200 KVA /250/320KVA capacity DG set complete all as specified and directed .
Supply only commutator unit as per existing make and model suitable for 160 KVA / 200 KVA /250/320KVA capacity DG set complete all as specified and directed .
Supply only stator starting coil unit as per existing make and model suitable for 160 KVA / 200 KVA /250/320KVA capacity DG set complete all as specified and directed .
Supply only stator running coil unit as per existing make and model suitable for 160 KVA / 200 KVA /250/320KVA capacity DG set complete all as specified and directed .
M & L for repair and reconditioning the starter motor 12 V DC of kirloskar / Cummins / Greaves make including taking out the defective starter from 25/62.5/82.5/100/125 KVA capacity DG set , complete dismantling and repair and replacing the carbon brushes with holder, solenoid switch assly, bush, commutator unit, starting starting coil, stator running coil etc and connecting with the circuit including all required items, starting and testing all as specified and directed by Engineer-in-charge. Note : Supply only of spare parts shall be measured ana paid separately under relevent item of this Schedule
Supply only carbon brush set with holder as per existing make and model suitable for 25/62.5/82.5/100/125 KVA capacity DG set complete all as specified and directed .
Supply only Solenoid switch assembly with bush as per existing make and model suitable for 25/62.5/82.5/100/125 KVA capacity DG set complete all as specified and directed .
Supply only commutator unit as per existing make and model suitable for 25/62.5/82.5/100/125 KVA capacity DG set complete all as specified and directed .
Supply only stator starting coil unit complete as per existing make and model suitable for 25/62.5/82.5/100/125 KVA capacity DG set complete all as specified and directed .
Supply only stator running coil unit as per existing make and model suitable for 25/62.5/82.5/100/125 KVA capacity DG set complete all as specified and directed .
M&L for repairs of copper / aluminium type radiator of capacity 25/62.5/82.5/100/125 KVA KVA DG Sets ,taking out by disconnecting from DG set and locating the leaking places and soldering / brazing complete with cleaning by acid and refixing in position including replacement of old oil hose pipe with new one including testing and commissioning of radiator for any leakage post repair complete all as specified and directed at site. Note : Supply only of oil hose shall be measured and paid separately under relevent item of this schedule
M&L for repairs of copper / aluminium type radiator of capacity 160 KVA / 200 KVA /250/320KVA KVA KVA DG Sets ,taking out by disconnecting from DG set and locating the leaking places and soldering / brazing complete with cleaning by acid and refixing in position including replacement of old oil hose pipe with new one including testing and commissioning of radiator for any leakage post repair complete all as specified and directed at site. Note : Supply only of oil hose shall be measured and paid separately under relevent item of this schedule
Supply only oil hose set complete for DG set of capacity 125/160/200 KVA complete all as directed
Supply only oil hose set complete for DG set of capacity 25/62.5/82.5 KVA complete all as directed.
S&F in replacement of 3 pole ML- 4 Contactor, heavy duty with aux contacts 415 Volt all as per existing make and model complete all as specified and directed.
S&F in replacement 3 pole MNX 325 Contactor , heavy duty with aux contacts 415 V all as perexisting make and model complete all as specified and directed.
S&F in replacement 4 pole MCX 32 contactor heavy duty with aux contacts 415 V, all as per IS, in existing AMF control panel of DG set 62.5 KVA, thorough checking, connecting with the system, testing both Auto and manual mode operation all as specified as directed
S&F in replacement 4 pole MCX 41 contactor heavy duty with aux contacts 415 V, all as per IS, in existing AMF control panel of DG set 125 KVA, thorough checking, connecting with the system, testing both Auto and manual mode operation all as specified as directed by Engr-in-Charge
S&F in replacement 4 pole MCX 33 contactor heavy duty with aux contacts 415 V, all as per IS, in existing AMF control panel of DG set 200 KVA, thorough checking, connecting with the system, testing both Auto and manual mode operation all as specified as directed by Engr-in-Charge
S&F in replacement 4 pole MNX 45 contactor heavy duty with aux contacts 415 V, all as per IS, in existing AMF control panel of DG set 200 KVA, thorough checking, connecting with the system, testing both Auto and manual mode operation all as specified as directed by Engr-in-Charge
S&F in replacement of 220 / 415 Volt Coil suitable for ML- 4 Contactor as per existing make and model complete all as specified and directed.
S&F in replacement of 215 / 415 Volt Coil suitable for MNX 325 / MCX 32 Contactor as per existing make and model complete all as specified and directed.
S&F in replacement of 220/415 Volt Coil suitable for MCX-41 Contactor as per existing make and model complete all as specified and directed.
S&F in replacement of 220/415 Volt Coil suitable for MCX-33 Contactor as per existing make and model complete all as specified and directed.
S&F in replacement of 220/415 Volt Coil suitable for MNX 45 Contactor as per existing make and model complete all as specified and directed.
M&L for taking down stator assembly of alternator 25/62.5/82.5/100/125 KVA DG Sets by disconnecting electrically and mechanically complete cleaning with CTC and decarbonising the stator , rotor and excitor coils, heating the coils for achieving insulation upto the mark, checking thoroughly the complete system and connections and replacing the defective insulation paper by applying Dr Beck varnish baking / heating and bringing back to installation and refixing and assembling the same Connecting electrically , mechanically and testing on completion of work complete all as directed by Engr-in-Charge
M&L for taking down stator assembly of alternator 160/200/250/320 KVA DG Sets by disconnecting electrically and mechanically complete cleaning with CTC and decarbonising the stator , rotor and excitor coils, heating the coils for achieving insulation upto the mark, checking thoroughly the complete system and connections and replacing the defective insulation paper by applying Dr Beck varnish baking / heating and bringing back to installation and refixing and assembling the same Connecting electrically , mechanically and testing on completion of work complete all as directed by Engr-in-Charge
S&F of UVT trip coil 240 / 415 Volt operate system as per existing make and model suitable for MCCB model DH complete all as directed at site.
Attending breakdown / inspection and rectifying defects of 25 KVA to 320 KVA DG Sets as and wherever required for smooth operation including AMF and Electrical Panel to check and locate / detect fault related to breakdown complete all as directed by Engineer-in-charge. Note:- (a) Spare parts shall be measured and paid separately under relavant items. (b) The break down complaint should be attended by concerned technician within 2 hours form the time of intimation of Engr-in-charge or concern JE E/M by telephonically / verbally. (c) If Not attending the complaints within two hours will lead to penal recovery from subsequent payment in the following manner :- (i) Not attending within 2 to 4 Hours - Rs. 2000.00 / Complaint (ii) Not attending within 4 to 6 Hours- Rs. 4000.00 / Complaint (iii) Not attending within 6 to 8 Hours- Rs. 8000.00 / Complaint (iv) Not attending after 8 Hours - Rs. 10,000.00 / Complaint (v) The maximum recovery will be Rs. 50,000.00 plus the expenditure incurred for rectification of the same by any other means.
S&F in replacement of maintenance free lead acid battery 12 Volt,180AH capacity complete with brass terminals including testing on load complete all as specified and directed
S&F in replacement maintenance free lead acid battery 12 volt 150 AH capacity all complete with brass terminals including testing on load complete all as specified and directed
S&F in replacement maintenance free lead acid battery 12 volt 130 AH capacity complete with brass terminals including testing on load complete all as specified and directed
Supply and fill distilled water for batteries 12 volt 180 / 150 AH / 130 AH all as specified and directed
S&F in replacement of Automatic battery charging unit with indication of automatic charge, float with charge indication and cut off 220 V input AC and output 12/24 V DC, 10 Amps and testing with DG sets complete all as specified and direceted.
S&F in replacment of alternator terminal connector in 62.5 to 320 KVA by taking out the burnt connector from alternator, checking cable lugs including testing complete all as specified and directed at site.
S&f in replacement exhaust manifold set of three pieces complete with gaskets , stud mountings, nuts etc complete ( centre , rear and front) as per existing make and model of 320/250/ 200 / 160 KVA DG set all as specified and as directed
S&F in replacement exhaust manifold set of three pieces complete with gaskets , stud mountings, nuts etc complete ( centre , rear and front) as per existing make and model of 25/62.5/82.5/100/125 KVA DG set all as specified and as directed
S&F in replacement of PT fuel pump by dismantling, transporting, repairing and calibration, testing and commissioning of PT fuel pump for 160 / 200 KVA/250/320KVA DG set including the replacement of all service kits, pulsvation damper, tacho drive shaft and seal, gear drive shaft , bearing, weight carriers, etc all as specified and directed
S&F in replacement of PT fuel pump by dismantling, transporting, repairing and calibration, testing and commissioning of PT fuel pump for 25/62.5/82.5/100/125 KVA DG set including the replacement of all service kits, pulsvation damper, tacho drive shaft and seal, gear drive shaft , bearing, weight carriers, etc all as specified and directed
M&L for for taking down stator assembly of alternator of DG set of capacity 25/62.5/82.5/100/ 125 KVA by disconnecting electrically and mechanically taking to work shop for rewinding incl removing burnt coils, insulating material complete cleaning with CTC and rewinding with same gauge ISI marked winding wire complete with ISI marked insulating paper and Dr Beck varnish baking / heating and bringing back to installation refixing , connecting electrically and mechanically and testing on completion of work complete all as specified and directed.
All as per item No 75 above but alternator for DG set of capacity 160/ 200 KVA/250/320KVA
S&F in replacement and commissioning 24 V DC heavy duty starter motor as per existing make and model suitable for 160 / 200/250 KVA Cummins / Kirloskar DG set all as directed
S&F in replacement and commissioning 12 V DC heavy duty self starter motor as per existing make and model suitable for 125/82.5/ 62.5 KVA Cummins / Kirloskar DG set all as directed
M&L for fixing in replacement of DG Set door Hinges & accessaries for 25/ 62.5/ 82.5/100/125 KVA DG Sets complete all as directed
M&L for fixing in replacement of DG Set door Hinges & accessaries for 160/ 200 / 250/320 KVA DG Sets complete all as directed
M&L for fixing in replacement of solid state potentiometer of 25 to 320 KVA DG set and testing as specified and directed
S&F in replacement fan pulley assembly of 25 to 320 KVA DG Set as per existing make and model complete all as directed at site.
S&F in replacement DG set control panel into Digital electronic control panel with mounting bracket with vibration isolating pads -3 nos of 160/200/250/320 KVA DG Sets as per existing make and model complete all as directed.
S&F in replacement DG set control panel into Digital electronic control panel with mounting bracket with vibration isolating pads -3 nos of 25/62.5/82.5/100/125KVA DG Sets as per existing make and model complete all as directed at Site.
S&F in replacement of Push button ( 2 nos ) as per existing make and model for ON / Off 25 to 320 KVA AMF panel connecting with control circuit including connection and testing complete all as specified and directed
S&F in replacement of coolant hose set Cummins part no. 67185 - 4 nos, 63495 - 2 nos, AK 5045 SS - 1 no, AK 16030 SS - 1 no, AK 16018 MS - 1 no including set of clamps complete all as specified and directed
S&F in replacement of Housing actuator under Cummins Part no.3166630 in 25 to 320 KVA DG set by taking out old from fuel pump complete all as specified and directed
S&F in replacement of drive accessory under Cummins cat pat No 3005123 in 25 to 320 KVA DG set all as directed
S&F in replacement seal accessory under Cummins cat part no 212227 in 25 to 320 KVA DG set all as directed
S & F in replacement Electronic Governor controller under Cummins part no.3413905 in 25/62.5/82.5/125/160/200/250/320 KVA DG set and testing all as specified and dicrected by Engineer-in-charge
Supply, installation, testing and commissioning of radiator for 200/250/320 KVA Cummins DG set under Cummins cat part no. 4020300 including dismantling of old / defective radiator, taking out from DG set base frame, fixing the new radiator assembly, fan and shroud of radiator, connecting cooling pipes inlet and outlet all as directed
M & L for supply, installation and commissioning of radiator for 160 KVA/100/125 KVA Cummins DG set under Cummins cat part no. 4020300 including dismantling of old / defective radiator, taking out from DG set base frame, fixing the new radiator assembly, fan and shroud of radiator, connecting cooling pipes inlet and outlet all as directed
M & L for supply, installation and commissioning of radiator for 25/62.5/82.5 KVA Cummins DG set under Cummins Part no. 4020300 including dismantling of old / defective radiator, taking out from DG set base frame, fixing the new radiator assembly, fan and shroud of radiator, connecting cooling pipes inlet and outlet all as directed
S&F in replacement of AMF Logic controller (Microprocessor based type) by taking out the defective unit from 25 / 62.5/ 82.5/100/125 KVA capacity DG set as per existing make and model complete checking the panel and its connection circuit in the panel board, providing proper interlink connection with DG set including all required items, starting and testing all as specified and directed
All as per item No 96 above but 160/ 200/250/320 KVA DG sets.
S&F in replacement start and stop relay 12 V/24 V DC suitable for AMF Panel capacity of 25 to 320 KVA all as specified and directed.
S & F in replacement of high bay light 150 W luminaries with high power (integral) with system lumen out put 220 volts,50 Hz, with suitable capacity drives in side housing complete all as specified and directed
S & F in replacement of heavy duty 5 star rating exhaust fan 600mm Sweep 240 volt , Opal White / brown including bracket nut bolts , and making hole for fitting fan on wall including all accessories complete all as specified and as directed
S&F in replacement of 5 star rating wall mounted fan (Air circulator) Turbo Force 600mm sweep compplete all as specified and as directed
Dismantling iron sections as in chequered plate and frame work to plates in any size and position all as specified and directed.
S&F plates (plain or chequered) plate channels square cut or notched forming holes , without any attachement including necessary welding as specified and directed.
S&F Rolled sections as in main and cross beam, frame work to ducts for laying chequered plates and similar work including necessary welding, grouting using PCC 1:3:6 nominal mix and making good to surface as required complete all as specified and as directed
M&L for applying two coats of synthetic enamel paint over a coat of red oxide, Zinc chrome primer on steel surfaces of any descrption , over 10cm width or girth, including preparing on new steel surfaces complete all as specified and directed.
S&F in replacement of digital panel board includes of Ammeter, Voltemeter , start and stop buttuns, oil temeprature , water pressure gauge , battery status indicator , suitable for 156 HP dainage pump all as specified and directed
M&L for writing MES NO of DG set in white / black colour complete all as specified and directed by Engineer -in - Charge Note : Minimum of 15 letters shall be considered as one job
M&L for cleaning of fuel tank made of MS sheet up to 320KVA DG Sets by draining out fuel in a separate container, taking out all silt / dirt deposition inside the tank, cleaning it completely by manual and necessary T&P and refitting and connecting with fuel pipes complete all as specified and as directed
S&F in replacement of battery lead with stranded copper conductor of size 70 sqmm single core PVC insulated flexible 0.6 M long along with battery terminal for positive and stator terminal duly soldered all as directed.
S&F in replacement of battery lead with stranded copper conductor of size 70 sqmm single core PVC insulated flexible 0.6M long along with battery terminal for negative and stator terminal duly soldered all as directed.
M&L for disconnecting LT supply and taking out defective LT draw out EDO type ACB 440 V 800Amp / 630Amp and servicing by OEM .i.e Authorised dealer cleaning the fixed and moving all parts, removing dust particles by using high speed blower applying grease/jelly to moving mechanism and moving parts, tightening nut bolts of all the components of ACB and complete testing and putting on full load all as specified and as directed by Engr-in-Charge
S&F in replacement of isolating JAW contacts suitable for 800Amp / 630Amp LT draw out EDO type ACB complete all as specified and as directed .
S&F in replacement of polyester resin cast CT 800 / 5A suitable for 800Amp /630Amp LT draw out EDO type ACB as per existing make and model complete all as directed at site
S&F in replacement of ARC Chutes for Air circuit breakers EDO type suitable for 800Amp/630Amp as per existing make and model complete all as directed at site
S&F in replacement of Pole Unit for Air circuit breakers EDO type suitable for 800Amp/630Amp as per existing make and model complete all as directed at site
S&F in replacement of Draw out terminals for Air circuit breakers EDO type suitable for 800/630 Amp as per existing make and model complete all as directed at site
S&F in replacement of Lower terminals for Air circuit brekers EDO type suitable for 800Amp/630Amp as per existing make and model complete all as directed at site
S&F in replacement of Upper terminals for Air circuit brekers EDO type suitable for 800Amp/630Amp as per existing make and model complete all as directed at site
S&F in replacement of Charging motor for Air circuit brekers EDO type suitable for 800Amp/630Amp as per existing make and model complete all as directed at site.
S&F in replacement of shunt trip and closing coil for Air circuit brekers EDO type suitable for 800Amp/630Amp complete all as specified and as directed
S&F in replacement of manual Charging handle for Air circuit breakers EDO type suitable for 800Amp/630Amp as per existing make and model complete all as directed at site
S&F in replacement of under voltage trip device compact with UVT coil for Air circuit breakers EDO type suitable for 800Amp/ 630Amp as per existing make and model complete all as directed at site
S&F in replacement of Safety shutter assembly for Air circuit breakers EDO type suitable for 800Amp/630Amp as per existing make and model complete all as directed at site.
S&F in replacement of Earth fault relay with NCT for Air circuit brekers EDO type suitable for 800/630 Amp as per existing make and model complete all as directed at site
S&F in replacement of sheet metal enclosure with socket plug top , five pin and neutral enclosure with three pin earth plug and socket complete with one MCB TPN of capacity 32 Amps complete all as specified and directed
S&F for Submersible water proof cable 3 core 35 Sqmm copper cable flat type complete all as specified and as directed.
S&F in replacement cable PVC FRLS insulated sheathed, unarmoured, round water proof with stranded copper conductor 1100 V grade of size 4 core 10 Sq mm for hanger motor up to 25 Mtr height and necessary clamp to move the round cable all as directed at site.
S&F in replacement cable PVC FRLS insulated sheathed, unarmoured, round water proof with stranded copper conductor 1100 V grade of size 4 core 16 Sq mm for hanger motor up to 25 Mtr height and necessary clamp to move the round cable all as directed at site.
S&F in replacement of MCCB, 415 volts, 4 pole adjustable thermal setting type 25 KA, 100 Amps.as per existing make and model complete all as directed.
S&F in replacement of MCCB, 415 volts, 4 pole adjustable thermal setting type 25 KA, 125 Amps. as per existing make and model complete all as directed.
S&F in replacement of MCCB, 415 volts, 4 pole adjustable thermal setting type 25 KA, 160 Amps as per existing make and model complete all as directed.
S&F in replacement of MCCB ,4 pole, 415V, 36KA, 200 Amps with adjustable thermal setting.as per existing make and model complete all as directed.
S&F in replacement of MCCB ,4 pole, 415V, 36KA, 250 Amps with adjustable thermal setting as per existing make and model complete all as directed.
S&F in replacement of MCCB ,4 pole, 415V, 36KA, 320 Amps with adjustable thermal setting as per existing make and model complete all as directed.
S&F in replacement of MCCB ,4 pole,415V, 36KA, 400 Amps with adjustable thermal setting as per existing make and model complete all as directed.
M&L for disconnecting electrically and mechanically induction electric motor from hanger door of capacity of 5 HP electrically operated three phase 415 volt, opening gear box assembly for inspection and servicing of gearbox assembly with steel truck channel , cleaning the slots and greasing , oiling the gear box assembly complete all as directed.
M&L for disconnecting electrically and mechanically defective induction electric motor from hanger door of capacity of 5 HP electrically operated three phase 415 volt, shifting to civil workshop for repair, strip opening for inspection, cutting of unserviceable burnt winding, taking out, cleaning of slots, rewinding with new super enameled ,copper conductor winding wire and replacement of u/s burnt insulating materials, sleeves etc,varnishing and other connected works,re-assembling,re-fixing at site, electrical connection fixing with pump set with nuts,bolts,washers as per original position and testing complete all as directed
M&L for disconnecting electrically and mechanically defective gear box assembly from hanger motor of capacity of 5 HP electrically operated three phase 415 volt,shifting to civil workshop for repair,strip opening for inspection, taking out unserviceable bearing, cleaning of slots, and replacement u/s gear pinion, back axile and filling with gear oil ,re-assembling,re-fixing at site as per original position and testing complete all as directed
S & F in replacement of digital soft starter suitable for 15 HP submersible pump including all connection and additional wiring etc all as specified and directed
Design, Supply, installing testing and commissioning factory fabricated in door type totally enclosed LT cubical AMF panel board suitable size with busbar, conforming to relevant IS and protection class IP-65 ,dust, vermin and weather proof fabricated out of 3.15mm thick CRCA sheet duly powder coated ,mounted on 40x40x5mm MS angle iron frame, duly welded in shape and coated with two coats of synthetic enamel paint of approved colour over a coat of red oxide primer including necessary grouting of legs 300mm deep in ground in PCC 1:4:8 type D2 using 40mm graded stone aggregate ,panel base to be 500mm above ground level with suitable compartments for controls and Monitors including cable glands for incoming and outgoing cables, locking arrangement, including accommodating, supply and fixing the following accessories/items including necessary internal panel wiring with suitable size of Copper wire PVC insulated & sheathed multi stranded complete all as specified and as directed by Engr-in-charge. including Supply and fixing the following :-
Design, Supply, installing testing and commissioning factory fabricated in door type totally enclosed LT cubical AMF panel board suitable size with busbar, conforming to relevant IS and protection class IP-65 ,dust, vermin and weather proof fabricated out of 3.15mm thick CRCA sheet duly powder coated ,mounted on 40x40x5mm MS angle iron frame, duly welded in shape and coated with two coats of synthetic enamel paint of approved colour over a coat of red oxide primer including necessary grouting of legs 300mm deep in ground in PCC 1:4:8 type D2 using 40mm graded stone aggregate ,panel base to be 500mm above ground level with suitable compartments for controls and Monitors including cable glands for incoming and outgoing cables, locking arrangement, including accommodating, supply and fixing the following accessories/items including necessary internal panel wiring with suitable size of Copper wire PVC insulated & sheathed multi stranded complete all as specified and as directed by Engr-in-charge. including Supply and fixing the following :-
S&F in replacement on load change over switch 415 V, 4 pole, 200 A open execution as per existing make and model suitable equivalent make as per list of make at PS complete all as specified and directed.
S&F in replacement on load change over switch 415 V, 4 pole, 250 A open execution as per existing make and model suitable equivalent make as per list of make at PScomplete all as specified and directed.
S&F in replacement on load changeover switch 415 V, 4 pole, 320A open execution as per existing make and model suitable equivalent make as per list of make at PScomplete all as specified and directed.
S&F in replacement on load changeover switch 415 V, 4 pole, 400A open execution as per existing make and model or suitable equivalent make as per list of make at PS complete all as specified and directed.
Kathir Marketing Services
A. R. ELECTRICALS
M/s Sriya Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .